Effect of the azimuthal orientation on the performance of grating-coupled surface-plasmon resonance biosensors.

The effect of azimuthal orientation on the electromagnetic coupling of surface plasmons with the incident and diffracted light of a grating-coupled surface-plasmon resonance (GC-SPR) biosensor is investigated, and its practical implications are explored. For this purpose a GC-SPR biosensor model is considered, and well-established rigorous coupled-wave analysis is used. Numerical results indicate significant variations in surface-plasmon resonance characteristics in connection with the interaction between surface-plasmon polaritons associated with multiple-order diffraction. The results are discussed as they relate to applications that require minimal rotation sensitivity.

Algorithms↗

Profile effect on the feasibility of extinction-based localized surface plasmon resonance biosensors with metallic nanowires.

We investigate the effect of the cross-sectional profile of an array of metallic nanowires on the feasibility of a localized surface plasmon resonance (LSPR) biosensor. Calculations were performed using rigorous coupled-wave analysis with an emphasis on the extinction properties of the LSPR structure. The results indicate that the nanowire structure, particularly that of a T-profile, delivers an extremely linear sensing performance over a wide range of the target refractive index with much enhanced sensitivity. The extinction-based LSPR structure also involves a relatively large dimension and thus is expected to provide a feasible biosensor using current semiconductor technology.

Biosensing Techniques↗

Sensitivity analysis of a nanowire-based surface plasmon resonance biosensor in the presence of surface roughness.

We have investigated the effect of surface roughness on the sensitivity of conventional and nanowire-based surface plasmon resonance (SPR) biosensors. The theoretical research was conducted using rigorous coupled-wave analysis with Gaussian surface profiles of gold films determined by atomic force microscopy. The results suggest that, when surface roughness ranges near 1 nm, the sensitivity of a conventional SPR system is not significantly affected regardless of the correlation length. For a nanowire-based SPR biosensor, however, we have found that the sensitivity degrades substantially with decreasing correlation length. In particular, at a correlation length smaller than 100 nm, a random rough surface may induce destructive coupling between excited localized surface plasmons, which can lead to prominent reduction of sensitivity enhancement.

Journal Article↗

Highly sensitive differential phase-sensitive surface plasmon resonance biosensor based on the Mach-Zehnder configuration.

A high-sensitivity surface plasmon resonance (SPR) biosensor based on the Mach-Zehnder interferometer design is presented. The novel feature of the new design is the use of a Wollaston prism through which the phase quantities of the p and s polarizations are interrogated simultaneously. Since SPR affects only the p polarization, the signal due to the s polarization can be used as the reference. Consequently, the differential phase between the two polarizations allows us to eliminate all common-path phase noise while keeping the phase change caused by the SPR effect. Experimental results obtained from glycerin-water mixtures indicate that the sensitivity limit of our scheme is 5.5 x 10(-8) refractive-index units per 0.01 degrees phase change. To our knowledge, this is a significant improvement over previously obtained results when gold was used as the sensor surface. Such an improvement in the sensitivity limit should allow SPR biosensors to become a possible replacement for conventional biosensing techniques based on fluorescence. Monitoring of the bovine serum albumin (BSA) binding reaction with BSA antibodies is also demonstrated.

Antigen-Antibody Complex↗

D-type fiber biosensor based on surface-plasmon resonance technology and heterodyne interferometry.

A D-type fiber biosensor based on surface-plasmon resonance (SPR) technology and heterodyne interferometry is presented. The sensing device is a single-mode optical fiber in which half the core is polished away and a thin-film layer of gold is deposited. We measure the phase-difference variations instead of the light intensity as in traditional SPR techniques. Therefore the accuracy and resolution of our method are very high. Its sensitivity can reach 2 x 10(-6) refractive-index units. The sensor has some merits, e.g., tunable high sensitivity, small size, lower cost, smaller sample volume, and suitability for in vivo testing. This novel method of a D-type fiber biosensor based on SPR technology and heterodyne interferometry is valuable for chemical, biological, and biochemical sensing, and the novel method of D-type fiber biosensing is a feasible means of study.

Alcohols↗

Determination of kinetic data using surface plasmon resonance biosensors.

The use of biosensors employing surface plasmon resonance (SPR) provides excellent instrumentation for a label-free, real-time investigation of biomolecular interactions. A broad range of biological applications including antibody-antigen interactions can be analyzed. One major advantage of kinetic analysis using SPR-based biosensors is the option of determining separately distinct association and dissociation rate constants exceeding the classical steady-state analysis of biomolecules. Based on these data new possibilities for drug design, characterizing human pathogens, and the development of therapeutic antibodies can be achieved. The hardware of commercially available systems is described, practical step by step procedures are given, and possibilities and limitations of the technology are discussed.

Antibodies↗

Fiberoptic biosensors based on chemiluminescent reactions.

The chemiluminescence of luminol in the presence of H2O2 has been exploited to develop fiberoptic biosensors associated with flow injection analysis systems. A chlorophenol sensor was developed based on the ability of certain halophenols to enhance the peroxidase-catalyzed luminol chemiluminescence. Horseradish peroxidase immobilized on a collagen membrane was used. Ten chlorophenols have been tested with this chemiluminescent-based sensor. The lower detection limit was obtained with 4-chloro-3-methylphenol and was equal to 0.01 microM. Electrochemiluminescent-based fiberoptic biosensors for glucose and lactate were also developed using glucose oxidase or lactate oxidase immobilized on polyamide membranes. In the presence of oxidase-generated H2O2, the light emission was triggered electrochemically by means of a glassy carbon electrode polarized at +425 mV vs a platinum pseudo-reference electrode. The detection limits for glucose and lactate were 150 and 60 pmol, respectively, and the dynamic ranges were linear from 150 pmol to 600 nmol and from 60 pmol to 60 nmol, respectively.

Biosensing Techniques↗

Electrochemical biosensors for environmental monitoring.

Highly sensitive electrochemical biosensors offer precision, sensitivity, rapidity, and ease of operation for on-site environmental analysis. An electrochemical biosensor is an analytical device in which a specific biological recognition element (bioreceptor) is integrated within or intimately associated with an electrode (transducer) that converts the recognition event to a measurable electrical signal for the purpose of detecting a target compound (analyte) in solution. The signal generated allows both qualitative and quantitative measurements of an analyte in real time. In most cases, a miniaturized electrochemical cell contains a low volume of analyte, which is vital when dealing with hazardous materials and makes such devices ideal for environmental monitoring. This approach not only provides the means for on-site analysis but also removes the time delay and sample alteration that can occur during transport to a centralized laboratory. We first address the basic principles of electroanalytical measurement and the merger of electrochemistry and biology into a biosensing system, and then we discuss various environmental monitoring strategies involving this technology.

Biosensing Techniques↗

Change in rigidity in the activated form of the glucose/galactose receptor from Escherichia coli: a phenomenon that will be key to the development of biosensors.

Recently a periplasmic glucose/galactose binding protein, GGRQ26C, immobilized on a gold surface has been used as an active part of a glucose biosensor based on quartz microbalance technique. However the nature of the glucose detection was not clear. Here we have found that the receptor protein film immobilized on the gold surface increases its rigidity when glucose is added, which explains the unexpected detection signal. To study the rigidity change, we developed a new fast and simple method based on using atomic force microscopy (AFM) in tapping mode. The method was verified by explicit measurements of the Young's modulus of the protein film by conventional AFM methods. Since there are a host of receptors that undergo structural change when activated by ligand, AFM can play a key role in the development and/or optimization of biosensors based on rigidity changes in biomolecules.

Biophysics↗

2,4-Toluene diamines--their carcinogenicity, biodegradation, analytical techniques and an approach towards development of biosensors.

2,4-Toluene diamine (TDA), a class A carcinogen, is a major raw material for the production of toluene diisocyanate (TDI), which is one of the precursors for the production of polyurethane foams (PU). This review deals with 2,4-toluene diamine's (TDA) carcinogenicity, analytical techniques, biodegradation and use as a biosensor for biogenic and synthetic amines, emphasizing various carcinogenicity studies by 2,4-TDA on animals and humans. This review reports some publications of the analysis of body fluid samples of workers from a PU producing factory for presence of TDA and TDI, since TDI gets absorbed into the worker's body, getting metabolized into TDA. Biodegradations of 2,4-TDA by various researchers are reported and also our own research experience with biodegradation of 2,4-TDA using Aspergillus nidulans isolated from soil site at a polyurethane foam dumping site have been discussed in this review. Biosensors for various biogenic and synthetic amines are discussed.

Animals↗

Novel biosensor for the rapid measurement of estrogen based on a ligand-receptor interaction.

A bioaffinity sensor was developed aiming at the detection of estrogen. This biosensor system is based on the specific binding of estrogen to its receptor immobilized on a gold disk electrode. The recombinant DNA encoding human estrogen receptor ligand-binding domain was expressed in bacteria using the histidine-tag fusion system. The expression of the fusion protein was under control of a bacteriophage T7 promoter, and the protein was purified under native conditions by affinity chromatography, which is based on a specific interaction between a histidine-tag, located in the N-terminus of the protein, and the Ni(II) chelate adsorbent. The protein was immobilized on an Au-electrode with Ni(II)-mediated chemisorption using a histidine tag and thiol-modified iminodiacetic acid. Cyclic voltammetric measurements showed that the reversible electrochemical reaction of a ferrocyanide/ferricyanide redox couple was suppressed by the presence of estrogen in a concentration-dependent manner. It seems reasonable to suppose that the electrostatic property of the protein layer on the electrode surface was altered by complexation with estrogen. These data suggest that this biosensor is applicable to the evaluation binding activities of the chemicals toward the human estrogen receptor.

Biosensing Techniques↗

Nitric oxide biosensors based on Hb/phosphatidylcholine films.

Hemoglobin (Hb) was entrapped in a phosphatidylcholine (PC) film and immobilized at a pyrolytic graphite (PG) electrode surface. Its electron-transfer reactivity and enzyme activity were characterized by employing electrochemical methods. It was observed that Hb exhibited direct electrochemistry as well as enzyme-like activity towards the electrocatalytic reduction of NO in PC film. An unmediated, reagentless nitrogen oxide (NO) biosensor was accordingly prepared. Experimental results revealed that the peak current related to NO was linearly proportional to its concentration in the range of 1.0 x 10(-7)-3.0 x 10(-4) mol/L. The detection limit was estimated to be 1.0 x 10(-7) mol/L. Considering its good stability, nice selectivity and easy construction, this biosensor shows great promise for the rapid determination of traces of NO.

Algorithms↗

Electroanalytical properties of aldehyde biosensors with a hybrid-membrane composed of an enzyme film and a redox Os-polymer film.

Aldehyde biosensors were constructed by cross-linking formaldehyde dehydrogenase (FDH) or aldehyde dehydrogenase (ADH) and bovine serum albumin on the surface of a redox Os-polymer-coated electrode. The prepared aldehyde biosensors responded rapidly (within 30 s) to aldehydes without the addition of a soluble mediator, because the inner redox Os-polymer film effectively mediated the electron transfer from NADH generated enzymatically into the outer enzyme film to a glassy carbon electrode. An FDH/Os-polymer electrode responded linearly over the concentration range of 2 x 10(-6)-5 x 10(-4) M for formaldehyde, while an ADH/Os-polymer electrode, though responding similarly to long chain aldehydes, such as propionaldehyde and butylaldehyde, responded linearly over the concentration range of 4 x 10(-6)-2 x 10(-4) M for acetaldehyde.

Aldehydes↗

A flow injection biosensor system for highly sensitive detection of 2,4,6-trichlorophenol based on preoxidation by ceric sulfate.

A flow injection biosensor system was proposed for the highly sensitive detection of 2,4,6-trichlorophenol (2,4,6-TCP). The system is based on the preoxidation by ceric sulfate to the corresponding benzoquinone (2,6-dichloro-1,4-benzoquinone: 2,6-DC-1,4-BQ), which was characterized using cyclic voltammetry, hydrodynamic voltammetry, and UV-vis spectrophotometry. The laccase-based biosensor used in this analytical system responded sensitively to 2,4,6-TCP after the preoxidation by ceric sulfate. The response could be based on the bioelectrocatalytic recycling of oxidation product (2,6-DC-1,4-BQ) between laccase membrane and the electrode, because the oxidation product (2,6-DC-1,4-BQ) of 2,4,6-TCP was an electrochemically reversible redox species. The signal current was linearly related to the 2,4,6-TCP concentrations in a dynamic range of 2 nM - 2 microM; the slope and the y-intercept of the straight line were 1150 nA microM(-1) and 0.88 nA, respectively. The detection limit was 1.2 nM (S/N = 3) for a 20 microl injection. Among a variety of chlorophenols and some phenolic compounds, the only interferent was 2,4-dichlorophenol.

Biosensing Techniques↗

An electrochemical biosensor for nitric oxide based on silver nanoparticles and hemoglobin.

A nitric oxide (NO) biosensor based on silver nanoparticles was fabricated with high sensitivity and selectivity as well as stability. Silver nanoparticles could preserve the microstructures of hemoglobin, but the electrochemical reactivity of the protein and its detection sensitivity toward NO could be greatly enhanced. Accordingly, a NO biosensor was developed. The linear concentration range was from 1.0 x 10(-6) to 5.0 x 10(-5) M. Its detection limit was 3.0 x 10(-7) M with a sensitivity of 0.0424 microA microM(-1) NO. The possible co-existing compounds would not interfere with the detection.

Biosensing Techniques↗

Determination of poly(3-hydroxybutyrate) using a combination of enzyme-based biosensor and alkaline hydrolysis.

The combination of an enzyme-based biosensor and alkaline hydrolysis was developed for the measurement of poly(3-hydroxybutyrate) (PHB). The principle of the determination is based on that the alkaline condition converts PHB to produce its monomer, 3-hydroxybutyrate (3-HB), which generates a detectable current signal by an amperometric biosensor through coupled two-enzyme reactions on an electrode. This method takes less than 40 min, and results in a linear detection range of 0.5-110 mg L-1 PHB with a detection limit of 0.3 mg L-1 by the saturated production of 3-HB; it can also take less than 15 min and result in a linear detection range of 1.0-160 mg L-1 PHB with a detection limit of 0.5 mg L-1 by a part production of 3-HB. The method also shows simple operation and high reproducibility.

Biosensing Techniques↗

The array biosensor: portable, automated systems.

With recent advances in surface chemistry, microfluidics, and data analysis, there are ever increasing reports of array-based methods for detecting and quantifying multiple targets. However, only a few systems have been described that require minimal preparation of complex samples and possess a means of quantitatively assessing matrix effects. The NRL Array Biosensor has been developed with the goal of rapid and sensitive detection of multiple targets from multiple samples analyzed simultaneously. A key characteristic of this system is its two-dimensional configuration, which allows controls and standards to be analyzed in parallel with unknowns. Although the majority of our work has focused on instrument automation and immunoassay development, we have recently initiated efforts to utilize alternative recognition molecules, such as peptides and sugars, for detection of a wider variety of targets. The array biosensor has demonstrated utility for a variety of applications, including food safety, disease diagnosis, monitoring immune response, and homeland security, and is presently being transitioned to the commercial sector for manufacturing.

Automation↗

Determination of binding constant of DNA-binding drug to target DNA by surface plasmon resonance biosensor technology.

The experimental determination of the binding constant of a drug for its target molecule is of considerable importance. It is a basic experimental parameter in a variety of studies, such as the prediction of drug efficiency, or in the pharmacokinetic drug interaction. DNA-binding drugs have been reported to be able to interfere in a sequence dependent manner with biological functions such as topoisomerase activity, restriction of enzyme cleavage of DNA, protein-DNA interactions and the activity of transcription factors, leading to alteration of gene expression. This effect could have important practical application in the experimental therapy of human pathologies, including neoplastic diseases and viral, or microbial infections. The assessment of the biological activity of DNA-binding drugs by polymerase chain reaction, footprinting, gel retardation and in vitro transcription studies was recently reported. However, most of these techniques are steady-state methodologies and therefore are not suitable for an easy determination of the binding activity of DNA-binding drugs to target DNA and the stability of drugs-DNA complexes. Direct real-time observation and measurement of the interaction between DNA-binding drug and target DNA sequence is a subject of interest for drug discovery and development. The recent development of biosensors, based on surface plasmon resonance (SPR) technology, enables monitoring of a variety of biospecific interactions of DNA-binding drugs with target DNA elements in real-time. The present review is designed to indicate the theoretical background of SPR-based biosensor technology as well as to present the great variety of measurements and modes of interaction kinetics that can be performed with these techniques. In addition, some of the most recent studies in determining the binding constant and stoichiometry of DNA-binding drugs to target DNA with SPR technology are reviewed and the available theoretical aspects necessary for the comprehension of the experiments are provided.

Animals↗