PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “parameter optimization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75Linked to original sources

Optimization of the SPME parameters and its online coupling with HPLC for the analysis of tricyclic antidepressants in plasma samples.

Solid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 2(3) factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-mum film thickness) fiber is selected after the assessment of different types of coating. The chromatographic separation is realized using a C(18) column (150 x 4.6 mm, 5-microm particles), ammonium acetate buffer (0.05 mol/L, pH 5.50)-acetonitrile (55:45 v/v) with 0.1% of triethylamine as mobile phase and UV-vis detection at 214 nm. Among the factorial design conditions evaluated, the best results are obtained at a pH 11.0, temperature of 30 degrees C, and extraction time of 45 min. The proposed method, using a lab-made SPME-LC interface, allowed the determination of tricyclic antidepressants in in plasma at therapeutic concentration levels.

Antidepressive Agents, Tricyclic↗

Development of a fluorescence detection system using optical parametric oscillator (OPO) laser excitation for in vivo diagnosis.

In this work, the development and applications of a fluorescence detection system using optical parametric oscillator (OPO) laser excitation for in vivo disease diagnosis including oral carcinoma are described. The optical diagnosis system was based on an OPO laser for multi-wavelength excitation and time-resolved detection. The pulsed Nd-YAG-pumped OPO laser system (6 ns, 20 Hz) is compact and has a rapid, broad, and uniform tuning range. Time-gated detection of intensified charge-coupled device (ICCD) making use of external triggering was used to effectively eliminate the laser scattering and contribute to the highly sensitive in vivo measurements. Artificial tissue-simulating phantoms consisting of polystyrene microspheres and tissue fluorophores were tested to optimize the gating parameters. 51-ns gate width and 39-ns gate delays were determined to be the optimal parameters for sensitive detection. In vivo measurements with the optical diagnosis system were applied to esophagus, stomach, and small intestine using an endoscope in canine animal studies. The rapid tuning capability of the optical diagnosis system contributed greatly to the optimization of wavelength for the observation of porphyrin in the small intestine. When the small intestine was thoroughly washed with water, the emission band which corresponds to porphyrin disappeared. Based on this observation, it was concluded that the detected signal was yielded by porphyrin-containing bile secretion. Also, multispectral analyses using multiple excitations from 415 to 480 nm at 5 nm intervals confirmed the porphyrin detection in the small intestine. The optical diagnosis system was also applied to the detection of human xenograft of oral carcinoma in mice using 5-aminolevulinic acid (5-ALA) which is a photodynamic therapy (PDT) drug. Significant differences in protoporphyrin IX fluorescence intensity between normal and tumor tissue could be obtained 2 hours after the injection of 5-ALA into mice due to the preferential accumulation of 5-ALA in tumors. Results reported herein demonstrate potential capabilities of the LIF-OPO system for in vivo disease diagnosis.

Animals↗

Sensitivity analysis of grating parameter estimation.

An optimization method for the sensitivity of diffraction efficiency measurements is presented. I define the sensitivity as the estimation precision of the grating parameters. The optimization method called sensitivity analysis for fitting scans all the possible measurement configurations and selects the configuration that yields the best sensitivity. The scan is made over the domain of the experimental parameters of the arrangement, such as the azimuth angle of the grating and the orientation angles of the analyzer and the polarizer. These parameters can be freely varied, and among the multitude of possible combinations there is one configuration that provides optimum sensitivity. Comparison with experimental results reveals a qualitative agreement between theory and practice.

Journal Article↗

A non-adrenergic inhibitory nervous pathway in guinea-pig trachea.

1 Electrical stimulation of the guinea-pig isolated tracheal tube causes a biphasic response, initially excitatory and then inhibitory. The excitatory response was abolished by atropine leaving the inhibitory response unaffected.2 The inhibitory response was greatly reduced but not abolished by propranolol or guanethidine. A residual inhibitory response was still present in tracheas in which sympathetic nerve function had been abolished by pretreatment with syrosingopine or 6-hydroxydopamine. These results show that the inhibitory response is predominantly adrenergic but that a small non-adrenergic component is also present.3 The non-adrenergic inhibitory response was abolished by lignocaine and tetrodotoxin suggesting that it is nervous in origin.4 Optimal stimulation parameters for the predominantly adrenergic inhibitory response were a pulse width of 0.7-2 ms, a stimulation period of 7 s and a frequency of 20 Hz. For the non-adrenergic inhibitory response, optimal stimulation parameters were a pulse width of 2 ms, a stimulation period of 12 s and a frequency of 20 Hz.5 Evidence obtained with pharmacological antagonists, enzyme inhibitors and activators suggested that the transmitter mediating the non-adrenergic inhibitory nervous response is unlikely to be: acetylcholine, histamine, 5-hydroxytryptamine, cyclic 3',5'-adenosine monophosphate or a prostaglandin.6 The adenosine uptake blocking drugs dipyridamole, hexobendine and Dilazep potentiated the non-adrenergic inhibitory nervous response and unmasked inhibitory responses to adenosine and adenosine 5'-triphosphate.7 It is concluded that electrical stimulation of the guinea-pig trachea, in addition to activating cholinergic and adrenergic nervous pathways, may activate a separate and distinct inhibitory nervous pathway. This pathway has some features in common with the non-adrenergic non-cholinergic inhibitory pathways in gastro-intestinal muscle.

Adenosine↗

Optimization strategies for HPLC enantioseparation of racemic drugs using polysaccharides and macrocyclic glycopeptide antibiotic chiral stationary phases.

The chiral resolution by high performance liquid chromatography (HPLC) is controlled by a number of parameters. The optimization of HPLC parameters is an important issue in chiral resolution. This review discusses the optimization of HPLC conditions for the chiral resolution of racemic drugs on polysaccharides and macrocyclic glycopeptide antibiotic chiral stationary phases (CSPs). The most important parameters discussed are composition of mobile phase, pH of mobile phase, flow rate, temperature and effect of other parameters.

Anti-Bacterial Agents↗

Discrepancy-based adaptive regularization for GRAPPA reconstruction.

PURPOSE: To develop a novel regularization method for GRAPPA by which the regularization parameters can be optimally and adaptively chosen. MATERIALS AND METHODS: In the fit procedures in GRAPPA, the discrepancy principle, which chooses the regularization parameter based on a priori information about the noise level in the autocalibrating signals (ACS), is used with the truncated singular value decomposition (TSVD) regularization and the Tikhonov regularization, and its performance is compared with the singular value (SV) threshold method and the L-curve method, respectively by axial and sagittal head imaging experiments. RESULTS: In both axial and sagittal reconstructions, normal GRAPPA reconstruction results exhibit a relatively high level of noise. With discrepancy-based choices of parameters, regularization can improve the signal-to-noise ratio (SNR) with only a very modest increase in aliasing artifacts. The L-curve method in all of the reconstructions leads to overregularization, which causes severe residual aliasing artifacts. The 10% SV threshold method yields good overall image quality in the axial case, but in the sagittal case it also leads to an obvious increase in aliasing artifacts. CONCLUSION: Neither a fixed SV threshold nor the L-curve are robust means of choosing the appropriate parameters in GRAPPA reconstruction. However, with the discrepancy-based parameter-choice strategy, adaptively regularized GRAPPA can be used to automatically choose nearly optimal parameters for reconstruction and achieve an excellent compromise between SNR and artifacts.

Algorithms↗

Combined genetic algorithm and multiple linear regression (GA-MLR) optimizer: Application to multi-exponential fluorescence decay surface.

The optimization approach based on the genetic algorithm (GA) combined with multiple linear regression (MLR) method, is discussed. The GA-MLR optimizer is designed for the nonlinear least-squares problems in which the model functions are linear combinations of nonlinear functions. GA optimizes the nonlinear parameters, and the linear parameters are calculated from MLR. GA-MLR is an intuitive optimization approach and it exploits all advantages of the genetic algorithm technique. This optimization method results from an appropriate combination of two well-known optimization methods. The MLR method is embedded in the GA optimizer and linear and nonlinear model parameters are optimized in parallel. The MLR method is the only one strictly mathematical "tool" involved in GA-MLR. The GA-MLR approach simplifies and accelerates considerably the optimization process because the linear parameters are not the fitted ones. Its properties are exemplified by the analysis of the kinetic biexponential fluorescence decay surface corresponding to a two-excited-state interconversion process. A short discussion of the variable projection (VP) algorithm, designed for the same class of the optimization problems, is presented. VP is a very advanced mathematical formalism that involves the methods of nonlinear functionals, algebra of linear projectors, and the formalism of Fréchet derivatives and pseudo-inverses. Additional explanatory comments are added on the application of recently introduced the GA-NR optimizer to simultaneous recovery of linear and weakly nonlinear parameters occurring in the same optimization problem together with nonlinear parameters. The GA-NR optimizer combines the GA method with the NR method, in which the minimum-value condition for the quadratic approximation to chi(2), obtained from the Taylor series expansion of chi(2), is recovered by means of the Newton-Raphson algorithm. The application of the GA-NR optimizer to model functions which are multi-linear combinations of nonlinear functions, is indicated. The VP algorithm does not distinguish the weakly nonlinear parameters from the nonlinear ones and it does not apply to the model functions which are multi-linear combinations of nonlinear functions.

Algorithms↗

Computer interface for vial sealing force measurements.

The force applied to the closure of a parenteral container is a critical parameter in assuring the integrity of a seal. Measurement of the force can be accomplished either off line, through residual force measurements, or on line, through instrumentation of the sealing station. The instrumentation of the sealing station provides a dynamic profile of the sealing event for development of the optimal sealing parameters. A computer interface for this application has been developed using a standard IBM-AT and commercially available data acquisition hardware and software. The resultant data can be set up in Lotus 1-2-3, or any other analysis package capable of importing ASCII files, for graphic display, and/or additional analysis. The system thus provides a means to acquire quantitative data on the sealing event for development of optimal sealing parameters.

Drug Packaging↗

Determination of mercury in hair by square-wave anodic stripping voltammetry at a rotating gold disk electrode after microwave digestion.

A simple and reliable method for the determination of mercury in hair on a rotating gold disk electrode using subtractive anodic stripping voltammetry without removal of oxygen is reported. Voltammetric and microwave parameters were optimized to obtain the best analytical results. Parameters such as supporting electrolyte concentration, influence of chloride in the Hg peak, deposition potential, scan rate, accumulation time, rotation rate, square-wave amplitude, and electrode conditioning were studied. Pressurized microwave-assisted digestion of hair, suitable for the accurate voltammetric determination of Hg, was evaluated using six acid mixtures and several time-power programs. Under the optimized conditions, no interference by copper, cadmium, lead, nickel, manganese, iron, or zinc was found at concentrations corresponding to their occurrence in normal hair. A calibration plot between 6,67 and 46,69 microg/L was linear, with r(2) better than 0.999. The detection limit for a deposition time of 60 s at 254 g was calculated as 1.92 nM (3omega). Validation of the method was demonstrated with the use of a certified reference sample of hair. Eight real samples of hair (four unexposed children and four exposed persons) were also analyzed.

Child↗

Perfusion-CT assessment of infarct core and penumbra: receiver operating characteristic curve analysis in 130 patients suspected of acute hemispheric stroke.

BACKGROUND AND PURPOSE: Different definitions have been proposed to define the ischemic penumbra from perfusion-CT (PCT) data, based on parameters and thresholds tested only in small pilot studies. The purpose of this study was to perform a systematic evaluation of all PCT parameters (cerebral blood flow, volume [CBV], mean transit time [MTT], time-to-peak) in a large series of acute stroke patients, to determine which (combination of) parameters most accurately predicts infarct and penumbra. METHODS: One hundred and thirty patients with symptoms suggesting hemispheric stroke < or =12 hours from onset were enrolled in a prospective multicenter trial. They all underwent admission PCT and follow-up diffusion-weighted imaging/fluid-attenuated inversion recovery (DWI/FLAIR); 25 patients also underwent admission DWI/FLAIR. PCT maps were assessed for absolute and relative reduced CBV, reduced cerebral blood flow, increased MTT, and increased time-to-peak. Receiver-operating characteristic curve analysis was performed to determine the most accurate PCT parameter, and the optimal threshold for each parameter, using DWI/FLAIR as the gold standard. RESULTS: The PCT parameter that most accurately describes the tissue at risk of infarction in case of persistent arterial occlusion is the relative MTT (area under the curve=0.962), with an optimal threshold of 145%. The PCT parameter that most accurately describes the infarct core on admission is the absolute CBV (area under the curve=0.927), with an optimal threshold at 2.0 ml x 100 g(-1). CONCLUSIONS: In a large series of 130 patients, the optimal approach to define the infarct and the penumbra is a combined approach using 2 PCT parameters: relative MTT and absolute CBV, with dedicated thresholds.

Adult↗

Pulsed electron avalanche knife (PEAK-fc) for dissection of retinal tissue.

OBJECTIVE: To evaluate the effectiveness and precision of tractionless retinal tissue dissection by the advanced version of the pulsed electron avalanche knife for fine cutting (PEAK-fc; Carl Zeiss Meditec, Jena, Germany). METHODS: Porcine retina (in vivo) and human retina (in vitro) were incised with the PEAK-fc using various pulse parameters. The globes were then processed for light microscopy. Evaluation of all specimens focused on depth of the retinal cuts and on the degree of collateral damage. RESULTS: Retinal cuts performed both in vivo on porcine eyes and on human donor eyes showed very sharp edges with only little collateral damage. With probes of 600 mum in length, the optimal pulse parameters for precise and reproducible cutting of the retina were an amplitude of 350 to 380 V, a repetition rate of 300 Hz, and 30 "minipulses" per pulse of 100-microsecond duration. With increasing voltage, cuts also affected the retinal pigment epithelium and the choroid, followed by intravitreal bleeding during in vivo application. CONCLUSION: We demonstrated that PEAK-fc is capable of precisely cutting retinal tissue in vivo and in vitro using optimal pulse parameters. Further in vivo studies will be necessary to determine the efficacy of this new tractionless cutting device in vitreoretinal surgery.

Adult↗

L-curve analysis of radiotherapy optimization problems.

We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in the discrete ill-posed problems. The L-curve method is based on finding the regularization parameter which minimizes the residual norm which is a measure of accuracy of fit and the solution norm which is a measure of smoothness of solution. The main idea of the L-curve method is to plot the smoothing norm as a function of the residual norm for all values of the regularization parameter. This characteristic curve has an L-shaped dependence and the optimal value of regularization parameter can be found at the "corner" of the L-curve. We plot the L-curves for the optimization problems which simulate prostate radiotherapy cancer treatment with intensity-modulated beams. Different numerical methods are applied to calculate the point of maximum curvature of the L-curves which is a criterion to locate the corner. We show that the point of maximum curvature can be located in a most robust way using a formula derived from the singular value decomposition analysis.

Algorithms↗

19F Magnetic resonance imaging of perfluorooctanoic acid encapsulated in liposome for biodistribution measurement.

The tissue distribution of perfluorooctanoic acid (PFOA), which is known to show unique biological responses, has been visualized in female mice by (19)F magnetic resonance imaging (MRI) incorporated with the recent advances in microimaging technique. The chemical shift selected fast spin-echo method was applied to acquire in vivo (19)F MR images of PFOA. The in vivo T(1) and T(2) relaxation times of PFOA were proven to be extremely short, which were 140 (+/- 20) ms and 6.3 (+/- 2.2) ms, respectively. To acquire the in vivo (19)F MR images of PFOA, it was necessary to optimize the parameters of signal selection and echo train length. The chemical shift selection was effectively performed by using the (19)F NMR signal of CF(3) group of PFOA without the signal overlapping because the chemical shift difference between the CF(3) and neighbor signals reaches to 14 kHz. The most optimal echo train length to obtain (19)F images efficiently was determined so that the maximum echo time (TE) value in the fast spin-echo sequence was comparable to the in vivo T(2) value. By optimizing these parameters, the in vivo (19)F MR image of PFOA was enabled to obtain efficiently in 12 minutes. As a result, the time course of the accumulation of PFOA into the mouse liver was clearly pursued in the (19)F MR images. Thus, it was concluded that the (19)F MRI becomes the effective method toward the future pharmacological and toxicological studies of perfluorocarboxilic acids.

Animals↗

Detection of juvenile sleep deprivation by stochastic optimization of pupillographic records.

OBJECTIVE: To address the challenging problem of measuring juvenile sleep deprivation, we test the hypothesis that a pupillographic method found successful for adult narcoleptics might also discriminate between sleep deprived juveniles acting as their own controls. METHODS: A linear, nonstationary model relating pupillary diameter and a random photic stimulus are estimated by recursive regressions from pupillographic records of 8 juveniles of median age 7 years acting as their own rested controls. The estimated pupillary impulse response noise functions are stochastically optimized using the Kullback divergence measure to maximally separate the sleep deprived records from the control records. RESULTS: Both the average and covariance statistics of the estimated pupillary noise functions exhibit statistically significant differences between sleep deprived and rested subjects. The main result is that sleep deprivation decreases pupillary noise variance; a finding consistent with a previous study of adult narcoleptics. Further, it was found that virtually the same stochastic parameters were optimal for the juvenile sleep deprived data and for the previous adult narcoleptic study. CONCLUSIONS: Although our results are preliminary, the consistent reduction of pupillary noise appears to justify a comprehensive clinical trial across a broad range of age classes. In addition, the finding that the same parameters stochastically optimize both juvenile and adult recordings suggests the procedure holds promise as a clinical test which could produce sleep deprivation measures simultaneous with data collection.

Algorithms↗

Structure of the photodissociation products of CCl4, CBr4, and CI4 in solution studied by DFT and ab initio calculations.

Various molecular species that can be populated during the photoreaction of carbon tetrahalides CX(4) (X = Cl, Br, I) in the gas phase and in solution have been studied by ab initio and density functional theory (DFT) calculations. Geometries, energies, and vibrational frequencies of CX(4), CX(3), CX(2), C(2)X(6), C(2)X(5), C(2)X(4), X(2), and the isomer X(2)CX-X were calculated and transition states connecting these species were characterized. Spin-orbit DFT (SODFT) computations were also performed to include the relativistic effects, which cannot be neglected for Br and I atoms. The calculated potential energy surfaces satisfactorily describe the reactions of the photoexcited CX(4) molecules. In the gas phase, the initial C-X bond rupture in CX(4) is followed by secondary C-X breakage in the CX(3) radical, leading to CX(2) and 2X, and the formation of C(2)X(6) or C(2)X(4) through bimolecular recombination of the CX(3) or CX(2) radicals is favored thermodynamically. In solution, by contrast, the X(2)CX-X isomer is formed via X-X binding, and two CX(3) radicals recombine nongeminately to form C(2)X(6), which then dissociates into C(2)X(4) and X(2) through C(2)X(5). The Raman intensities and the vibrational frequencies, as well as the absorption spectra and oscillator strengths of the Br(2)CBr-Br isomer in the gas phase and in various solvents were computed and the calculated absorption and Raman spectra of the Br(2)CBr-Br isomer in various solutions are in good agreement with the experimental data. The natural population analysis indicates that the Br(2)CBr-Br isomer corresponds to the recently reported solvent-stabilized solvated ion pair (CBr(3)(+)//Br(-))(solv) in the highly polar alcohol solvent. The singlet-triplet energy separations of the CX(2) radicals in the gas phase and in solution were evaluated with high level computational methods, and the optimized geometric parameters are in good agreement with the experimental results. The geometric and energetic differences between the singlet and triplet states were explained by the electronic properties of the CX(2) radicals. C(2)X(4), C(2)X(5), and C(2)X(6) (X = Br, I) in the gas phase and in solution were optimized at different computational levels, and the optimized geometric parameters of C(2)I(4) are in very good agreement with the experimental data.

Journal Article↗

Selective occlusion of choroidal neovascularization by photodynamic therapy with a water-soluble photosensitizer, ATX-S10.

BACKGROUND AND OBJECTIVE: To determine the optimal treatment parameters for selective occlusion of choroidal neovascularization (CNV) by photodynamic therapy (PDT) by using the photosensitizer ATX-S10 and a diode laser (wavelength = 670 nm). MATERIALS AND METHODS: Experimental CNV was induced in rat fundi by argon laser photocoagulation. The distribution of ATX-S10 in the chorioretina was analyzed by fluorescence microscopy, and the optimal treatment parameters for selective occlusion of CNV were investigated by changing the dosage and timing of laser irradiation. CNV closure and resulting damage of the surrounding tissue were documented by fluorescein angiography and light and electron microscopies. RESULTS: Fluorescence of ATX-S10 was observed to be localized in the vascular lumen of the retina and choroid within 5 min after dye injection and increased in intensity in CNV up to 2-6 h and decreased rapidly in normal tissue. Laser irradiation with radiant exposures of 7.4 J/cm2 applied immediately after dye injection or with 22.0 J/cm2 at 2-4 h later effectively occluded the induced CNV without causing significant damage to normal retinal capillaries and large choroidal vessels. CONCLUSIONS: PDT using ATX-S10 can selectively occlude CNV. ATX-S10 is a potentially useful photosensitizer for the treatment of CNV.

Animals↗

PET quantification of muscarinic cholinergic receptors with [N-11C-methyl]-benztropine and application to studies of propofol-induced unconsciousness in healthy human volunteers.

This work evaluated kinetic analysis methods for estimation of the receptor availability of the muscarinic receptor using dynamic positron emission tomography (PET) studies with [N-(11)C-methyl]-benztropine. The study also investigated the effect of propofol on central muscarinic receptor availability during general anesthesia. Six volunteers were scanned three times, once for baseline while awake, once during unconsciousness, and once after recovery to conscious level. An irreversible two-tissue compartment model was used to estimate the [N-(11)C-methyl]-benztropine specific binding rate constant k(3), a measure of muscarinic receptor availability. Two different estimation methods were used: 1) optimization with positivity constraints on all the parameters; 2) optimization with additional constraints determined from a one-tissue compartment fit to the cerebellum. In regions with low to middle muscarinic receptor density, the k(3) values from method (2) had lower standard errors than that for method (1) and gave a higher correlation with the density of muscarinic receptors measured in human tissue by in vitro studies (r(2) of 0.98 for Method 2 and r(2) of 0.72 for Method 1). But the k(3) values determined by Method 2 had higher errors for regions with high muscarinic receptor density compared to Method 1. For both methods the mean k(3) values during unconsciousness were generally lower than those during awake for most regions evaluated. Therefore, the method with additional constraints derived from the cerebellum (Method 2) was deemed superior for regions with low to middle muscarinic receptor density, while the method with positivity constraint is the better choice in the regions with high muscarinic receptor density. Our results also suggest the existence of propofol-related reductions in muscarinic receptor availability.

Adult↗

Morphological analysis and modeling of neuronal dendrites.

Morphological data on two classes of neurons from mammalian midbrain have quantitatively been analyzed for dendritic shape parameters. Their frequency distributions were used to optimize the parameters of a dendritic growth model which describes dendritic morphology by a stochastic growth process of segment branching. The model assumes randomness with respect to both the selection of the branching segment out of the tree segments and the occurrence of the branching event in time. Model-generated trees have shape properties closely matching the observed ones. The dendritic trees of each of the two classes of neurons are represented by a specific set of growth model parameters, thus achieving morphological data compression.

Animals↗