PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Capture”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

Estimating the efficiency of cell capture and arrest in flow chambers: study of neutrophil binding via E-selectin and ICAM-1.

A mathematical model was developed to quantify the efficiency of cell-substrate attachment in the parallel-plate flow chamber. The model decouples the physical features of the system that affect cell-substrate collision rates from the biological features that influence cellular adhesivity. Thus, experimental data on cell rolling and adhesion density are converted into "frequency" parameters that quantify the "efficiency" with which cells in the flow chamber progress from the free stream to rolling, and transition from rolling to firm arrest. The model was partially validated by comparing simulation results with experiments where neutrophils rolled and adhered onto substrates composed of cotransfected cells bearing E-selectin and intercellular adhesion molecule-1 (ICAM-1). Results suggest that: 1) Neutrophils contact the E-selectin substrate on average for 4-8.5s before tethering. This contact duration is insensitive to applied shear stress. 2) At 2 dyn/cm(2), approximately 28% of the collisions between the cells and substrate result in primary capture. Also, approximately 5-7% of collisions between neutrophils in the free stream and previously recruited neutrophils bound on the substrate result in secondary capture. These percentages were higher at lower shears. 3) An adherent cell may influence the flow streams in its vicinity up to a distance of 2.5 cell diameters away. 4) Our estimates of selectin on-rate in cellular systems compare favorably with data from reconstituted systems with immobilized soluble E-selectin. In magnitude, the observed on-rates occur in the order, L-selectin > P-selectin > E-selectin.

Algorithms↗

Lipid bilayer vesicle fusion: intermediates captured by high-speed microfluorescence spectroscopy.

The fusion of lipid bilayers can be visualized under the fluorescence microscope, but the process is very fast and requires special techniques for its study. It is reported here that vesicle fusion is susceptible to analysis by microspectrofluorometry and that for the first time, the entire fusion process has been captured. In the case of giant (>10- micro m diameter) bilayer vesicles having a high density of opposite charge, fusion proceeds through stages of adhesion, flattening, hemifusion, elimination of the intervening septum, and uptake of excess membrane to generate a spherical product very rapidly. These investigations became possible with a fluorescence microscope that was modified for recording of images simultaneously with the collection of fluorescence emission spectra from many (>100) positions along the fusion axis. Positively-charged vesicles, composed of O-ethylphosphatidylcholine and dioleoylphosphatidylcholine, were labeled with a carbocyanine fluorophore. Negatively-charged vesicles, composed of dioleoylphosphatidylglycerol and dioleoylphosphatidylcholine, were labeled with a rhodamine fluorophore that is a resonance energy transfer acceptor from the carbocyanine fluorophore. An electrophoretic chamber allowed selection of pairs of vesicles to be brought into contact and examined. Spectral changes along the axis of fusion were captured at high speed (a few ms/frame) by operating a sensitive digital camera in the virtual-chip mode, a software/hardware procedure that permits rapid readout of selected regions of interest and by pixel binning along the spectral direction. Simultaneously, color images were collected at video rates (30 frame/s). Comparison of the spectra and images revealed that vesicle fusion typically passes through a hemifusion stage and that the time from vesicle contact to fusion is <10 ms. Fluorescence spectra are well suited to rapid collection in the virtual-chip mode because spectra (in contrast to images) are accurately characterized with a relatively small number of points and interfering signals can be removed by judicious choice of barrier filters. The system should be especially well-suited to phenomena exhibiting rapid fluorescence change along an axis; under optimal conditions, it is possible to obtain sets of spectra (wavelength range of approximately 150 nm) at >100 positions along a line at rates >1000 frames/s with a spectral resolution of approximately 10 nm and spatial resolution at the limit of the light microscope ( approximately 0.2 micro m).

Biophysical Phenomena↗

Resolution of clonal origins for endometriotic lesions using laser capture microdissection and the human androgen receptor (HUMARA) assay.

OBJECTIVE: To determine the clonal origins of endometriotic lesions using laser capture microdissection and PCR-based HUMARA assay. DESIGN: Molecular genetic study of human tissue. SETTING: Molecular genetics laboratory in an academic setting. PATIENT(S): Twenty patients with endometriosis. Forty specimens of endometriotic lesions from these patients and one specimen of normal endometrium were analyzed. INTERVENTION(S): Laser capture microdissection was used to harvest epithelial cells from single and multifocal endometrial lesions from paraffin-embedded and frozen tissues, and their clonality was determined with the HUMARA assay. MAIN OUTCOME MEASURE(S): Polymerase chain reaction-based HUMARA assay of clonality. RESULT(S): Thirty-eight specimens were polymorphic and thus informative. Most specimens were monoclonal, as determined by the HUMARA assay. In four specimens of multifocal lesions, polyclonality was detected, but upon more refined microdissections and further analyses, we found that each focus was monoclonal individually. CONCLUSION(S): Previously reported polyclonality is very likely to be attributed to the pooling of multifocal lesions or contamination of normal tissues. These results suggest that endometriotic lesions were monoclonal in origin, and in the case of multifocal lesions, each focus originates monoclonally; hence, different foci have independent origins. The monoclonality of endometriotic lesions suggests that they may carry neoplastic potentials, and the apparent independent origins of multifocal lesions suggest that reconstruction of individual lesion histories may help us to understand the initiation and progression of endometriosis.

Adult↗

Protecting embryos from stress: corticosterone effects and the corticosterone response to capture and confinement during pregnancy in a live-bearing lizard (Hoplodactylus maculatus).

Hormones in the embryonic environment, including those of the hypothalamo-pituitary-adrenal (HPA) axis, have profound effects on development in eutherian mammals. However, little is known about their effects in reptiles that have independently evolved viviparity. We investigated whether exogenous corticosterone affected embryonic development in the viviparous gecko Hoplodactylus maculatus, and whether pregnant geckos have a corticosterone response to capture and confinement that is suppressed relative to that in non-pregnant (vitellogenic) females and males. Corticosterone implants (5 mg, slow-release) administered to females in mid-pregnancy caused a large elevation of corticosterone in maternal plasma (P<0.001), probable reductions in embryonic growth and development (P=0.069-0.073), developmental abnormalities and eventual abortions. Cool temperature produced similar reductions in embryonic growth and development (P< or =0.036 cf. warm controls), but pregnancies were eventually successful. Despite the potentially harmful effects of elevated plasma corticosterone, pregnant females did not suppress their corticosterone response to capture and confinement relative to vitellogenic females, and both groups of females had higher responses than males. Future research should address whether lower maternal doses of corticosterone produce non-lethal effects on development that could contribute to phenotypic plasticity. Corticosterone implants also led to increased basking in pregnant females (P<0.001), and basal corticosterone in wild geckos (independent of reproductive condition) was positively correlated with body temperature (P<0.001). Interactions between temperature and corticosterone may have broad significance to other terrestrial ectotherms, and body temperature should be considered as a variable influencing plasma corticosterone concentrations in all future studies on reptiles.

Animals↗

Electron-capture mass spectrometry: recent advances.

Electron-capture (EC) is a sensitive and selective ionization technique for mass spectrometry (MS). In the most familiar form of EC, a susceptible analyte (electrophore) is detected after eluting from a gas chromatography (GC) column, where a low attomole detection limit for standards is routine. High-performance liquid chromatography can facilitate sample cleanup prior to detection by GC-EC-MS, but carryover and shifts in retention time for the "invisible" analyte can be difficulties. Solid-phase extraction avoids these difficulties, but the degree of cleanup and recovery can be problems. Alternative electrophoric derivatizing reagents are available to help deal with interferences, and new reagents such as "AMACE1" are emerging. Releasable forms of electrophores can be used as tags for labeling macromolecules, motivated by the desire to multiplex ligand-type assays. The conventional, gas-phase ion source for EC is not well-understood, especially the role of wall reactions. Using an electron monochromator to tune the electron energy adds to the selectivity and information provided by EC-MS. High-resolution and tandem EC-MS measurements are emerging. Electron-capture dissociation is a new technique to sequence small- to medium-sized peptides, having the advantage of providing more extensive sequence information relative to other MS techniques. Particle-beam EC-MS tends to be less sensitive than GC-EC-MS, but not always. Recently it was demonstrated that EC-MS can be accomplished on an ordinary laser desorption time-of-flight mass spectrometer, and also by using atmospheric pressure chemical ionization. Two applications are discussed here in detail: bile acids and oxidized phenylalanine. EC-MS is well-established as a useful technique for trace analysis in special cases, and the scope of its usefulness is broadening (qualitative analysis and detection of more polar and larger molecules), based on advances in both the chemical and instrumental aspects of this technique.

Mass Spectrometry↗

Determination of fungicides in natural waters using solid-phase microextraction and gas chromatography coupled with electron-capture and mass spectrometric detection.

This study develops a method for the analysis of seven fungicides in environmental waters, using solid-phase microextraction (SPME). The analyzed compounds--dicloran, chlorothalonil, vinclozolin, dichlofluanid, captan, folpet and captafol--belong to different classes of chemical compound (chloroanilines, sulphamides, phthalimides and oxazolidines) and are used mainly in agriculture and as antifouling paints. Their determination was carried out by gas chromatography with electron-capture and mass spectrometric detection. To perform SPME, four types of fibre have been assayed and compared: polyacrylate (85 microm), polydimethylsiloxane (100 and 30 microm), carbowax-divinylbenzene (CW-DVB 65 microm) and polydimethylsiloxane-divinylbenzene (65 microm). The main parameters affecting the SPME process such as pH, salt additives, methanol content, memory effect, stirring rate and adsorption-time profile were studied. The method was developed using spiked natural waters such as ground water, sea water, river water and lake water in a concentration range of 0.1-10 microg/l. Limits of detection of studied compounds were determined in the range of 1-60 ng/l, by using electron-capture and mass spectrometric detectors. The recoveries of all fungicides were in relatively high levels (70.0-124.4%) and the average R2 values of the calibration curves were above 0.990 for all the analytes. The SPME conditions were finally optimized in order to obtain the maximum sensitivity. The potential of the proposed method was realized by applying it to the trace-level screening determination of fungicides and antifouling compounds in sea water samples originating from various Greek marinas.

Calibration↗

Determination of plasma amitriptyline by electron-capture gas chromatography after oxidation to anthraquinone.

A selective procedure is described for the determination of amitriptyline in plasma. The method involves extraction, separation of amitriptyline from its metabolites and subsequent oxidation by ceric sulphate in 5.4 M sulphuric acid. The oxidation product, anthraquinone, is determined by means of electron-capture gas chromatography. The metabolites were separated by a column chromatographic extraction technique. The choice of oxidation reagent, optimum conditions for the oxidation, and the electron-capture properties of anthraquinone are discussed. The method can be used to determine down to 2 ng of amitriptyline in a plasma sample; the relative standard deviation at the 50-ng level was 4.0% (n = 8). The levels of amitriptyline found in a series of plasma samples are compared with those obtained by gas chromatography with use of nitrogen-specific detection; the two techniques gave coincident results.

Amitriptyline↗

Quantitative determination of propranolol, propranolol glycol and N-desisopropylpropranolol in brain tissue by electron capture gas chromatography.

A method for the quantitative determination of propranolol and two of its active metabolites, 3-(alpha-naphthoxy)-1,2-propanediol (propranolol glycol) and N-des-isopropylpropranolol, in brain tissue of mice is described. Tissues are homogenized in perchloric acid-acetonitrile. Propranolol and its metabolites are isolated from the supernatant by solvent extraction and separated and detected as their trifluoroacetyl derivatives by electron capture gas chromatography. Chemical structures of the derivatives were confirmed by gas chromatography-mass spectrometry. The electron capture detector response of all three compounds is high, 0.7-2.0 X 10(-16) moles/sec. Brain levels of 10-250 ng/g can be detected of all three compounds with high specificity and good precision.

Animals↗

Gas chromatographic determination of pemoline in biological fluids using electron capture detection.

A simple and sensitive gas chromatographic (GC) method for the determination of pemoline in biological fluids, utilizing electron capture detection is described. Plasma samples with a pemoline analog added as internal standard were deproteinized with sulfosalicylic acid, and the supernatants were heated at 80 degrees. The pemoline-dione formed was extracted with benzene, and the extract was analyzed on a gas chromatograph equipped with a tritium foil electron capture detector. Poly A-103 (3%) on Gas-Chrom Q (100-120 mesh) packed in a 3-ft. silanized glass column was used as the stationary phase, with nitrogen serving as carrier gass. Under the same GC conditions, benzene extracts of pemoline-dione from acid-hydrolyzed urine samples were analyzed. Us-ng 1 ml of plasma or urine, the lower limit for the assay was about 0.1 microgram/ml. The method is accurate and reproducible, with a relative standard deviation with +/-4%. Mandelic acid (a metabolite of pemoline) does not interfere with the assay.

Animals↗

Specific and sensitive method for the determination of tobanum using gas chromatography with electron-capture and mass fragmentographic detection.

Quantitative gas--liquid chromatographic (GLC) and GLC--mass spectrometric (MS) methods for the determination of Tobanum, a new beta-blocking agent, in human plasma have been developed. After solvent extraction, a bis-trifluoroacetyl derivative is formed which is measured by an electron-capture detector. The quantitation is controlled by using an internal standard, propranolol hydrochloride, which is added to all samples. The electron-capture detector response is linear in the concentration range used, 5--150 ng/ml. The identity and quantity of the GLC peaks is confirmed by GLC--MS. The minimum detectable concentration of Tobanum is 1 ng using 3-ml plasma samples.

Adrenergic beta-Antagonists↗

Some 1,2-diaminobenzene derivatives as reagents for gas chromatographic determination of selenium with an electron-capture detector.

1,2-Diaminobenzene and its derivatives react with selenous acid in acidic solution to form the piazselenols, which can be extracted into toluene. Microgram amounts of selenium can be determined spectrophotometrically by measuring the absorbance of these piazselenols extracted into toluene. A more sensitive method, in which the piazselenols extracted into toluene are detected by electron-capture gas chromatography, has been developed. In order to find a more sensitive reagent, 13 piazselenols were synthesized. The retention behaviour and sensitivity in electron-capture detection gas chromatography and the distribution ratios between aqueous solution and toluene were studied for each piazselenol extracted into toluene. Of these piazselenols, 4,6-dibromopiazselenol, formed by the reaction of 1,2-diamino-3,5-dibromobenzene with selenous acid, was found to be best as regards sensitivity and distribution ratio. Under the optimal conditions for the formation and the extraction of the piazselenol, the practical detection limit was 1 ng. Selenium(VI) and total selenium in NBS Bovine Liver, SRM 1577, were determined successfully.

Aniline Compounds↗

Rapid and highly sensitive method for determination of methamphetamine and amphetamine in urine by electron-capture gas chromatography.

A rapid and sensitive method for determination of methamphetamine and amphetamine in urine was developed by using electron-capture gas chromatography. The extraction procedure, the experimental conditions for pentafluorobenzoyl derivative formation and the percentage recovery of the drugs from urine are described. The pentafluorobenzoyl derivative of methamphetamine showed a higher electron-capture sensitivity and was detected in at least 23-fold lower concentration than the heptafluorobutyryl derivative which is commonly used as a derivatizing agent for the amine. The detection limit of pentafluorobenzoyl derivatives of methamphetamine and amphetamine was ca. 10 pg. A concentration as low as 10 ng/ml of methamphetamine and amphetamine in urine was easily detected by this method.

Amphetamine↗

Studies on steroids. III. A new type of derivative for electron capture-gas chromatography of ketosteroids.

Pentafluorobenzyloxyamine is presented as a new derivatizing agent for gas chromatography of ketones using electron capture detection. The typical 17-ketosteroid was readily transformed into the O-pentafluorobenzyloxime which on usual trimethylsilylation led to a 3-trimethylsilyl ether derivative exhibiting good gas chromatographic properties. The derivatization procedure was applied to the determination of dehydroepiandrosterone in human plasma by electron capture-gas chromatography employing an internal standard method and in consequence satisfactory results were obtained.

Chromatography, Gas↗

Comparative study on the derivatization of l-alpha-acetyl-methadol metabolites for electron capture gas-liquid chromatography.

Six reagents-trichloroacetyl chloride, trichloroacetic anhydride, pentafluorobenzoyl chloride, heptafluorobutyryl chloride, heptafluorobutyric anhydride, and trifluoroacetic anhydride- were evaluated as potential derivatizing reagents for quantitating the metabolites of l-alpha-acetylmethadol (LAAM) -noracetylmethadol, dinoracetylmethadol, methadol, and normethadol-by electron capture gas-liquid chromatography. All of the reagents studied reacted quantitatively with all of the metabolites except methadol; however, trichloroacetyl chloride was found to be the most satisfactory general reagent for analyzing these metabolites in biological fluids. A gas-liquid chromatographic method is presented which combines both flame ionization and electron capture detection for quantitating plasma and urine levels of methadone, l-alpha-acetylmethadol and its metabolites.

Chromatography, Gas↗

Determination of clonidine in human plasma by glass capillary gas chromatography with electron-capture detection.

A gas chromatography assay for clonidine in human plasma has been developed. The buffered serum is extracted on silica columns, alkylated with pentafluorobenzyl bromide, cleaned up-by extractions and analysed by glass capillary gas chromatography with falling-glass-needle injection and electron-capture detection. A gas chromatographic-mass spectrometric analysis of the derivatives formed and an investigation of the structure dependence of the electron-capture response are presented.

Capillary Action↗

Determination of bromhexine as its trifluoroacetyl derivative by gas-liquid chromatography with electron-capture detection.

A specific gas-liquid chromatographic method with electron-capture detection is described for the determination of bromhexine at the nanogram level. Structurally analogous internal standards were synthesized and their suitability was investigated, based on their chromatographic properties on different stationary liquid phases. The electron-capture activity of the compounds is increased by trifluoroacetylation. Reaction conditions for this derivatization were studied. Calibration graphs in the range 0-57 ng (in a total of 100 microliters of reaction mixture) showed good linearity.

Bromhexine↗

Determination of nitrazepam and its main metabolites in urine by gas--liquid chromatography: use of electron capture and nitrogen-selective detectors.

Nitrazepam and its main urinary metabolites, 7-aminonitrazepam and 7-acetamidonitrazepam, free and conjugared, were determined from 24-h fractions of human urine after a single oral dose of 5 mg of nitrazepam. Nitrazepam and the metabolites were extracted before and after glusulase hydrolysis with benzene--dichloromethane (90:10) from a 1.0 ml sample. Methylnitrazepam and methylbromazepam served as internal standards. Recoveries were better than 90%. GLC analysis of nitrazepam was performed using a 63Ni electron-capture detector. The metabolites were measured by a dual flameless nitrogen selective detector. The detection limits were about 0.2 ng/ml for nitrazepam and 50 ng/ml for the metabolites. The nitrogen-selective detector responds similarly to all three compounds. The 63Ni electron-capture detector gives very poor response to 7-amino-nitrazepam but allows very sensitive detection of nitrazepam. Combined use of the two detectors gives valuable information about the metabolic profile of nitrazepam.

Adolescent↗

Glass capillary gas chromatography with electron-capture detection. Separation of prostaglandins.

Glass capillary gas chromatography of the prostaglandins was performed on a system including an all-glass, solventless injector; thermostable methylphenyl-polysiloxane glass capillary columns; and a conventional electron-capture detector fitted with a make-up gas tee. The principal stable metabolites of prostaglandin endoperoxide were separated as perfluorinated derivatives in 35 min. Detection limits equal or exceed those obtained for packed column separations and electron capture detection. Prostaglandin endoperoxide metabolic profiles from mammalian cell cultures were obtained using this system. These profiling studies are not possible with other chromatographic methods because of inferior resolution and sensitivity.

Animals↗