PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

A miniaturized wide-angle 2D cytometer.

BACKGROUND: We present an optical waveguide based cytometer that is capable of simultaneously collecting the light scattered by cells over a wide range of solid angles. Such comprehensive scattering data are a prerequisite for the microstructural characterization of cells. METHODS: We use latex beads as cell mimics, and demonstrate the ability of this new cytometer to collect back-scattered light in two dimensions (2D). This cytometer is based on a liquid-core optical waveguide, excited by prism coupling, that also serves as the microfluidic channel. In principle, our use of a hemispherical lens allows the collection of scattered light from 0 to 180 degrees in 2D. RESULTS: The experimentally observed positions of the intensity peaks of the back-scattered light agree well with theoretical prediction of scattering from both 4.0- and 9.6-mum diameter latex beads. The position of the bead, relative to the axes of the hemispherical lens and the microchannel, strongly affects the scattering pattern. We discuss a computational method for determining these offsets. CONCLUSIONS: We show that wide-angle 2D light scattering patterns of cell-sized latex beads can be observed in a microfluidic-based optical cytometer that uses leaky waveguide mode excitation. This chip-based system is compatible with emerging chip-based technologies.

Cell Biology↗

Surface modification in microchip electrophoresis.

Different approaches and techniques for surface modification of microfluidic devices applied for microchip electrophoresis are reviewed. The main focus is on the improved electrophoretic separation by reducing analyte-wall interactions and manipulation of electroosmosis. Approaches and methods for permanent and dynamic surface modification of microfluidic devices, manufactured from glass, quartz and also different polymeric substrates, are described.

Acrylic Resins↗

Electroosmotic flow in a poly(dimethylsiloxane) channel does not depend on percent curing agent.

Poly(dimethylsiloxane) (PDMS) microfluidic devices were prepared from different ratios of "curing agent" (which contains silicon hydride groups) to "base" (which contains vinyl-terminated noncross-linked PDMS), to determine the effect of this ratio on electroosmotic flow (EOF). In fabricating devices for this purpose, a novel method for permanently enclosing PDMS channels was developed. As a supplement to the microfluidic method, the inner walls of capillaries were coated with PDMS formed from varying ratios of curing agent to base. EOF was found to be constant for PDMS formed with each ratio, which implies that the negative surface charges do not arise from chemical species present only in the base or the curing agent.

Dimethylpolysiloxanes↗

Microchannel wall coatings for protein separations by capillary and chip electrophoresis.

The necessity for microchannel wall coatings in capillary and chip-based electrophoretic analysis of biomolecules is well understood. The regulation or elimination of EOF and the prevention of analyte adsorption is essential for the rapid, efficient separation of proteins and DNA within microchannels. Microchannel wall coatings and other wall modifications are especially critical for protein separations, both in fused-silica capillaries, and in glass or polymeric microfluidic devices. In this review, we present a discussion of recent advances in microchannel wall coatings of three major classes--covalently linked polymeric coatings, physically adsorbed polymeric coatings, and small molecule additives. We also briefly review modifications useful for polymeric microfluidic devices. Within each category of wall coatings, we discuss those used to eliminate EOF, to tune EOF, to prevent analyte adsorption, or to perform multiple functions. The knowledgeable application of the most promising recent developments in this area will allow for the separation of complex protein mixtures and for the development of novel microchannel wall modifications.

Acrylic Resins↗

High-resolution DNA separation in microcapillary electrophoresis chips utilizing double-L injection techniques.

An experimental and numerical investigation into the use of high-resolution injection techniques to separate DNA fragments within electrophoresis microchips is presented. The principal material transport mechanisms of electrokinetic migration, fluid flow, and diffusion are considered, and several variable-volume injection methods are discussed. A detailed analysis is provided of a double-L injection technique, which employs appropriate electrokinetic manipulations to reduce sample leakage within the microchip. The leakage effect in electroosmotic flow (EOF) is investigated using a sample composed of rhodamine B and Cy3 dye. Meanwhile, the effects of sample leakage in capillary electrophoresis (CE) separation are studied by considering the separation of 100-base pairs (bp) DNA ladders and HaeIII-digested PhiX-174 DNA samples. The present experimental and simulation results indicate that the unique injection system employed in the current microfluidic chip has the ability to replicate the functions of both the conventional cross-channel and the shift-channel injection systems. Furthermore, applying the double-L injection method to these two injection systems is shown to reduce sample leakage significantly. The proposed microfluidic chip and double-L injection technique developed in this study have an exciting potential for use in high-resolution, high-throughput biochemical analysis applications and in many other applications throughout the micrototal analysis systems field.

DNA↗

Capillary zone electrophoresis of amino acids on a hybrid poly(dimethylsiloxane)-glass chip.

Poly(dimethylsiloxane) (PDMS)-PDMS and hybrid PDMS-glass devices have been characterized and compared in terms of current-voltage linearity, contact angle, electroosmotic velocity, electroosmotic mobility, and electrokinetic potential in dependence on the surface treatment. The hybrid PDMS-glass microfluidic devices have further been tested as on-chip capillary electrophoresis systems for the separation of fluorescently labeled amino acids. It has been demonstrated that different methods of surface pretreatment of the PDMS-glass devices result in significantly different separation performance, with plate numbers varying from 650 to 57 000 in dependence on the surface state and the nature of the amino acids. Electrophoretic separations of amino acids have been achieved within tens of seconds with detection limits of less than 2 microM (approximately 2 x 10(-16) to 2.5 x 10(-16) mol quantities at injection volumes of 110-120 pL). The detected amounts of fluorescein isothiocyante (FITC)-amino acids are at least ten times lower, since the amino acid:FITC ratio is 10:1 mol. The results demonstrate the perspective of such hybrid PDMS-glass microfluidic systems and the methods to modify their surfaces for on-chip separation methods for biomolecules.

Amino Acids↗

Simultaneous determination of glutathione and reactive oxygen species in individual cells by microchip electrophoresis.

A microchip electrophoresis method was developed for simultaneous determination of reactive oxygen species (ROS) and reduced glutathione (GSH) in the individual erythrocyte cell. In this method, cell sampling, single-cell loading, docking, lysing, and capillary electrophoretic separation with LIF detection were integrated on a microfluidic chip with crossed channels. ROS was labeled with dihydrorhodamine 123 in the intact cell, while GSH was on-chip labeled with 2,3-naphthalene-dicarboxaldehyde, which was included in the separation medium. On-chip electrical lysis, characterized by extremely fast disruption of the cellular membrane (<40 ms), was exploited to minimize enzymatic effects on analyte concentrations during the determination. The microfluidic network was optimized to prevent cell leaking from the sample reservoir (S) into separation during the separation phase. The structure of the S was modified to avoid blockage of its outlet by deposited cells. Detection limits of 0.5 and 6.9 amol for ROS and GSH, respectively, were achieved. The average cell throughput was 25 cells/h. The effectiveness of the method was demonstrated in the simultaneous determination of GSH and ROS in individual cells and the variations of cellular GSH and ROS contents in response to external stimuli.

Adult↗

Direct coupling of polymer-based microchip electrophoresis to online MALDI-MS using a rotating ball inlet.

We report on the coupling of a polymer-based microfluidic chip to a MALDI-TOF MS using a rotating ball interface. The microfluidic chips were fabricated by micromilling a mold insert into a brass plate, which was then used for replicating polymer microparts via hot embossing. Assembly of the chip was accomplished by thermally annealing a cover slip to the embossed substrate to enclose the channels. The linear separation channel was 50 microm wide, 100 microm deep, and possessed an 8 cm effective length separation channel with a double-T injector (V(inj) = 10 nL). The exit of the separation channel was machined to allow direct contact deposition of effluent onto a specially constructed rotating ball inlet to the mass spectrometer. Matrix addition was accomplished in-line on the surface of the ball. The coupling utilized the ball as the cathode transfer electrode to transport sample into the vacuum for desorption with a 355 nm Nd:YAG laser and analyzed on a TOF mass spectrometer. The ball was cleaned online after every rotation. The ability to couple poly(methylmethacrylate) microchip electrophoresis devices for the separation of peptides and peptide fragments produced from a protein digest with subsequent online MALDI MS detection was demonstrated.

Bombesin↗

Rapid on-chip postcolumn labeling and high-resolution separations of DNA.

When performing genetic analysis on microfluidic systems, labeling the sample DNA for detection is a critical preparation step. Labeling procedures often involve fluorescently tagged primers and PCRs, which lengthen experimental run times and introduce higher levels of complexity, increasing the overall cost per analysis. Alternatively, on-chip labeling techniques based on intercalating dyes permit rapid labeling of DNA fragments. However, as noted in the literature, the stochastic nature of dye-DNA complex formation hinders the native electrophoretic migration of DNA fragments, degrading the separation resolution. In this study, we present a novel method of controllably labeling DNA fragments at the end of the electrophoretic separation channel in a glass microfluidic chip. Permitting the DNA to separate and labeling just before detection, achieves the rapid labeling associated with intercalators while maintaining the high resolution of native DNA separations. Our analyses are completed in minutes, rather than the hours typical of sample prelabeling. We demonstrate an electrophoretic microchip-based intercalator labeling technique that achieves higher resolution performance than reported in the literature to date.

DNA↗

Parallel analysis of biomolecules on a microfabricated capillary array chip.

This paper focused on a self-developed microfluidic array system with microfabricated capillary array electrophoresis (mu-CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda-lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high-voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.

Amino Acids↗

On-chip chiral separation based on bovine serum albumin-conjugated carbon nanotubes as stationary phase in a microchannel.

A novel method of chiral separation based on protein-stationary phase immobilized in a poly(methyl methacrylate) microfluidic chip was developed. BSA conjugated with the shortened carboxylic single-walled carbon nanotubes (SWNTs) was employed as the chiral selector. Successful separation of tryptophan enantiomers was achieved in less than 70 s with a resolution factor of 1.35 utilizing a separation length of 32 mm. This is the first example of chiral separation based on SWNTs-BSA conjugates as stationary phase immobilized in microchip channel. The stability of the stationary phase in the channel was examined by microchip electrophoresis with laser-induced fluorescence detection. Factors that influenced the chiral separation resolution were examined. Under the optimized conditions, the proposed modified chip revealed adequate repeatability concerning run-to-run. These results show that the use of SWNTs-BSA conjugates within microfluidic channels hold great promise for a variety of analytical schemes.

Carbon↗

Microchip free-flow electrophoresis on glass substrate using laser-printing toner as structural material.

In this work, a microfluidic free-flow electrophoresis device, obtained by thermal toner transferring on glass substrate, is presented. A microdevice can be manufactured in only 1 h. The layout of the microdevice was designed in order to improve the fluidic and electrical characteristics. The separation channel is 8 microm deep and presents an internal volume of 1.42 microL. The deleterious electrolysis effects were overcome by using a system that isolates the electrolysis products from the separation channel. The Joule heating dissipation in the separation channel was found to be very efficient up to a current density of 8.83 mA/mm(2) that corresponds to a power dissipation per unit volume of running electrolyte of 172 mW/microL. Promising results were obtained in the evaluation of the microdevices for the separation of ionic dyes. The microfluidic device can be used for a continuous sample pretreatment step for micro total analysis system.

Electrophoresis, Microchip↗

Poly(methyl methacrylate) CE microchips replicated from poly(dimethylsiloxane) templates for the determination of cations.

A novel method for the rapid fabrication of poly(methyl methacrylate) (PMMA) microfluidic chips using poly(dimethylsiloxane) (PDMS) templates has been demonstrated. The PDMS molds were fabricated by soft lithography. The dense prepolymerized solution of methyl methacrylate containing thermal and UV initiators was allowed to polymerized between a PDMS template and a piece of a 1 mm thick commercial PMMA plate under a UV lamp. The images of microchannels on the PDMS template were precisely replicated into the synthesized PMMA substrates during the UV-initiated polymerization of the prepolymerized solution on the surface of the PMMA plate at room temperature. The polymerization could be completed within 10 min under ambient temperature. The chips were subsequently assembled by thermal bonding of the channel plate and the cover sheet. The new fabrication method obviates the need for specialized replication equipment and reduces the complexity of prototyping and manufacturing. Nearly 20 PMMA chips were replicated using a single PDMS mold. The attractive performance of the new microfluidic chips has been demonstrated by separating and detecting cations in connection with contactless conductivity detection. The fabricated PMMA microchip has also been successfully employed for the determination of potassium and sodium in environmental and biological samples.

Cations, Monovalent↗

Dielectrophoresis microsystem with integrated flow cytometers for on-line monitoring of sorting efficiency.

Dielectrophoresis (DEP) and flow cytometry are powerful technologies and widely applied in microfluidic systems for handling and measuring cells and particles. Here, we present a novel microchip with a DEP selective filter integrated with two microchip flow cytometers (FCs) for on-line monitoring of cell sorting processes. On the microchip, the DEP filter is integrated in a microfluidic channel network to sort yeast cells by positive DEP. The two FCs detection windows are set upstream and downstream of the DEP filter. When a cell passes through the detection windows, the light scattered by the cell is measured by integrated polymer optical elements (waveguide, lens, and fiber coupler). By comparing the cell counting rates measured by the two FCs, the collection efficiency of the DEP filter can be determined. The chips were used for quantitative determination of the effect of flow rate, applied voltage, conductivity of the sample, and frequency of the electric field on the sorting efficiency. A theoretical model for the capture efficiency was developed and a reasonable agreement with the experimental results observed. Viable and non-viable yeast cells showed different frequency dependencies and were sorted with high efficiency. At 2 MHz, more than 90% of the viable and less than 10% of the non-viable cells were captured on the DEP filter. The presented approach provides quantitative real-time data for sorting a large number of cells and will allow optimization of the conditions for, e.g., collecting cancer cells on a DEP filter while normal cells pass through the system. Furthermore, the microstructure is simple to fabricate and can easily be integrated with other microstructures for lab-on-a-chip applications.

Cell Separation↗

Direct and indirect electroosmotic flow velocity measurements in microchannels.

As microfluidic technologies mature, increasingly complex solutions are employed, and accurate methods for the measurement of electroosmotic flow rates are becoming increasingly important. The methodologies of both a direct method and an indirect method of flow rate measurement are presented here. The direct method involves flow visualization using trace amounts of a caged fluorescent dye. The indirect method is based on the change in current that occurs when one solution in the microchannel is replaced by another. The results of concurrent and independent measurements of electroosmotic velocities of Tris-acetate with EDTA (TAE) and Tris-borate with EDTA (TBE) at 1x concentration in fused silica capillaries are presented. Although these buffers are commonly used in biological chemistry, these mobilities have not previously been reported. Strong agreement among data collected with both methods establishes confidence in the electroosmotic mobility values obtained and indicates that the current-based method, which requires less infrastructure than the direct method, can provide accurate flow rate measurements under these conditions. Constant electroosmotic mobilities of 4.90 x 10(-8) m(2) V(-1) s(-1) for TAE and 3.10 x 10(-8) m(2) V(-1) s(-1) for TBE were determined by tests in a range of electrical field strengths from 5 to 20 kV/m. A linear flow rate increase with applied field strength indicated that constant mobility and negligible Joule heating effects were present. Applicability and limitations of both the measurement methods and these buffers are discussed in the context of microfluidic applications.

Journal Article↗

Squalene and squalane emulsions as adjuvants.

Microfluidized squalene or squalane emulsions are efficient adjuvants, eliciting both humoral and cellular immune responses. Microfluidization stabilizes the emulsions and allows sterilization by terminal filtration. The emulsions are stable for years at ambient temperature and can be frozen. Antigens are added after emulsification so that conformational epitopes are not lost by denaturation and to facilitate manufacture. A Pluronic block copolymer can be added to the squalane or squalene emulsion. Soluble antigens administered in such emulsions generate cytotoxic T lymphocytes able to lyse target cells expressing the antigen in a genetically restricted fashion. Optionally a relatively nontoxic analog of muramyl dipeptide (MDP) or another immunomodulator can be added; however, the dose of MDP must be restricted to avoid systemic side effects in humans. Squalene or squalane emulsions without copolymers or MDP have very little toxicity and elicit potent antibody responses to several antigens in nonhuman primates. They could be used to improve a wide range of vaccines. Squalene or squalane emulsions have been administered in human cancer vaccines, with mild side effects and evidence of efficacy, in terms of both immune responses and antitumor activity.

Acetylmuramyl-Alanyl-Isoglutamine↗

A novel instrument for studying the flow behaviour of erythrocytes through microchannels simulating human blood capillaries.

A novel instrument has been developed to study the microrheology of erythrocytes as they flow through channels of dimensions similar to human blood capillaries. The channels are produced in silicon substrates using microengineering technology. Accurately defined, physiological driving pressures and temperatures are employed whilst precise, real-time image processing allows individual cells to be monitored continuously during their transit. The instrument characterises each cell in a sample of ca. 1000 in terms of its volume and flow velocity profile during its transit through a channel. The unique representation of the data in volume/velocity space provides new insight into the microrheological behaviour of blood. The image processing and subsequent data analysis enable the system to reject anomalous events such as multiple cell transits, thereby ensuring integrity of the resulting data. By employing an array of microfluidic flow channels we can integrate a number of different but precise and highly reproducible channel sizes and geometries within one array, thereby allowing multiple, concurrent isobaric measurements on one sample. As an illustration of the performance of the system, volume/velocity data sets recorded in a microfluidic device incorporating multiple channels of 100 microns length and individual widths ranging between 3.0 and 4.0 microns are presented.

Adult↗

Liposome-encapsulated hemoglobin: a synthetic red cell.

Liposome-encapsulated hemoglobin (LEH) is being developed at the Naval Research Laboratory as a universally transfusable oxygen-carrying blood replacement. A chemical engineering scale-up feasibility study has been completed recently. We report here the development of an encapsulation method which produces liters of phospholipid/cholesterol liposomes containing at least 16 g% hemoglobin in a few hours. The 0.2 micron liposomes are produced with a Microfluidizer TM (Microfluidics Corp., Newton, MA) adapted for this purpose, and then washed and sterile filtered using a Pellicon (Millipore, Bedford, MA) tangential flow filtration device. Previously, production limitations and lack of sterility have been serious barriers to toxicity testing for all the researchers engaged in related investigations. The biophysical properties of the LEH thus produced are ideal for use as a blood substitute, resembling those of red blood cells. The oxygen-binding affinity of LEH can be maintained at the level of fresh whole blood for many weeks by co-encapsulation of pyridoxal-5-phosphate. The circulation persistence time of liposomes is a function of the type of phospholipid. We have developed a formulation which has a circulation persistence time of 15-20 hours. The LEH oxygen binding characteristics, circulation half-life and its lipid composition dependence, scale-up preparation method, and a sterilization method are presented.

Animals↗