PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polyesters”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

The growth improvement of porcine esophageal smooth muscle cells on collagen-grafted poly(DL-lactide-co-glycolide) membrane.

Synthetic polyester and the extracellular matrix component collagen are among the most widely used materials in tissue engineering. However, the integration of collagen into polyester scaffolds without loss of its biological function is a problem that has not been fully solved. This article investigates the covalent immobilization of collagen onto poly(DL-Lactide-co-Glycolide) (PLGA) membrane surfaces via a bridge of 1,8-diaminooctane and with glutaraldehyde as crosslinking agent. X-ray photoelectron spectroscopy (XPS) and fluorescence measurements confirmed the presence of bonded collagen. The effect of collagen grafting on cell behavior was investigated by comparing collagen-PLGA with unmodified PLGA sample and tissue culture polystyrene (TCPS) plates by using porcine esophageal smooth muscle cells (ESMC). DNA analysis showed that collagen-modified PLGA improved the overall proliferation of the ESMCs compared with unmodified PLGA and TCPS plates. Cells seeded on collagen-modified PLGA also showed a more extended morphology. Thus, we believe that collagen-modified PLGA shows good potential to be used as a scaffold material for tissue engineering of the esophagus.

Animals↗

Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament.

We compared the mechanical behavior of two common hamstring graft constructs that are frequently used for reconstruction of the anterior cruciate ligament-Graft A: quadrupled semitendinosus tendon fixed with titanium button/polyester tape and suture/screw post, and Graft B: a double semitendinosus and double gracilis tendon fixed with a cross pin and two screws over washers. The experimental protocol used to evaluate each graft construct included stress relaxation (with and without preconditioning), cyclic loading, and a tensile load-to-failure test. The amount of stress relaxation without preconditioning was 60.6% for Graft A and 53.8% for Graft B. With preconditioning, it significantly decreased (p < 0.05) to 48.7 and 42.3%, respectively. Elongation of the graft construct in response to 100 cycles of loading (20-150 N) was 1.8 and 0.6% of the original length for Grafts A and B, respectively. However, after a series of five cyclic loading tests, the residual permanent elongation for each construct was 3.8 +/- 1.2 and 0.3 +/- 0.2 mm, a significant difference (p < 0.05) between the two graft constructs. Further analysis found more than 90% of the permanent elongation in the proximal and distal regions of Graft A, which consisted of polyester tape tied to a titanium button (proximal) and sutures tied around a screw post (distal). The tensile load-to-failure tests also revealed significant differences (p < 0.05) between the two graft constructs. Linear stiffness was 32 +/- 1 and 119 +/- 19 Nmm and ultimate load was 415 +/- 36 and 658 +/- 128 N for Grafts A and B, respectively. For Graft A, the polyester tape consistently failed; for Graft B, slippage or tearing from the washers was the mode of failure. We conclude that a quadruple-hamstring graft fixed over a cross pin proximally and with metal washers distally (Graft B) has less permanent elongation in response to cyclic loading and has structural properties superior to those of a graft construct that includes suture and tape material (Graft A). The large permanent elongation following repetitive loading of a graft construct with tape and suture material during the early postoperative period is of concern.

Aged↗

Mechanical comparison of 10 suture materials before and after in vivo incubation.

The material properties of ten 2-O suture materials were evaluated tensiometrically at time = 0 and again after 6 weeks incubation in rats. All suture material was incubated and tested without knots. Specialized machinery was used with a custom securing apparatus to pull suture material apart at constant speed. Stress-strain curves were derived, and from these strength, toughness, strain at rupture, and elastic modulus were determined. Sutures tested included Vicryl [poly(glycolide-lactide)], Dexon (polyglycolic acid), Ethibond (polyester), silk, plain gut, chromic gut, Maxon (polyglyconate), PDS (polydioxanone), nylon, and Prolene (polypropylene). Elastic modulus was greatest for braided, least for monofilament, and intermediate for gut sutures, regardless of chemical composition (ANOVA, P = 0.0001). Strength, strain, and toughness decreased in all of the sutures over time in vivo with the exception of braided polyester (Ethibond), which remained stable. Silk demonstrated the least strength and toughness while PDS and Maxon were the strongest and toughest at time = 0. Vicryl, Dexon, and gut sutures were absorbed to the point that they could not be tested after 6 weeks in vivo. Performance tables are provided for all sutures.

Animals↗

The current potential of plastination.

This review surveys the potential of plastination, a technique of tissue preservation introduced eight years ago. In this process, water and lipids in biological tissues are replaced by curable polymer which are subsequently hardened, resulting in dry, odorless and durable specimens. The procedure consists of the following steps - fixation, dehydration, forced impregnation in a vacuum, and hardening. The properties of the finished specimen are determined by the class of polymer used. Silicone yields flexible, resilient specimens, allows the broadest range of application, and provides satisfactory results with minimum equipment. Specimens plastinated with an epoxy-silicone copolymer are rigid enough to be polished, but are not unbreakable. This resin is used for thick, opaque body slices and showcase specimens. Epoxy resins are used for thin (2.5 mm), transparent body or organ slices. They are cast between polyester foils or glass plates and can be used for histological investigations. Polyester resin is used for the production of opaque brain slices, which gives excellent differentiation between grey and white matter. The application of plastination in research and the production of teaching specimens is discussed with special regard to the equipment required, cost, and feasibility of the processing.

Anatomy↗

Solar heat load: heat balance during exercise in clothed subjects.

Six subjects exercised for 60 min on a cycle ergometer. Their backs were exposed to an artificial 'sun' with a spectral distribution similar to sunlight and an intensity of 724 W m-2. Each subject took part in four experiments in random order: wearing suits of polyester (insulation value = 0.5 clo), white (WP) or black (BP), or cotton (0.6 clo), white (WC) or black (BC). Measured by partitional calorimetry, the calculated heat losses and gains for the four conditions balanced within less than 10%. The differences between the short-wave radiation gains of subjects in white or black garments were small. This is due to the transparency of the white materials, which allows a larger percentage of the radiation to penetrate the clothing. The surface temperatures of the sun-exposed areas were very high, especially in the black suits. This promotes dry heat loss. Therefore the sweat loss in the black suits and the differences between the black and white clothes became relatively small. The physiological strain in steady-state exercise, as expressed by average heart rates, was 142 (WP), 154 (BP), 151 (WC), and 160 (BC) beats min-1; the sweat losses were 649 (WP), 666 (BP), 704 (WC), and 808 (BC) g. For both of these measures values for white polyester were significantly less than those for black cotton.

Adult↗

Toxicity to fish of flame retardant fabrics immersed in their water. Part I.

A number of commercial and candidate flame retardants were studied with regard to their toxicity to fish when released from fabrics immersed in their water. Immersion of laundered or unlaundered flame retardant 100% polyester or polyester blend fabrics used in children's sleepwear in water containing goldfish resulted in release of the anticholin-esterase flame retardant TDBPP (tris (2, 3-dibromopropyl) phosphate) and death of all fish within 24 hours. TDBPP undergoes loss of HBr in water and production of a metabolite.

Animals↗

Anatomo-experimental study for lace fixation of winged scapula in muscular dystrophy.

Winging of the scapula is one of the major features of the rare facio-scapulo-humeral muscular dystrophy. Several methods of retention and fixation of the scapulae have been published, but most have technical disadvantages or complications. A modified method of operative fixation of the scapula to the chest using three polyester laces is described with the results of cadaveric studies on the stability of this system. In order to determine the optimal region for the scapula fixation using polyester laces we performed pull-out tests on twenty cadaver scapulae. Four points of insertion in the inferior part of the scapula were tested. The lateral margin showed the best results with regard to the tensile strength and the morphology of the resulting fractures. The elongation of the laces was measured as well. Compared to scapulothoracic arthrodesis interscapulo-scapulocostal scapulopexy leads to greater preserved mobility between the scapula and the chest wall and conserves vital capacity.

Adolescent↗

Biodegradation of polyhydroxyalkanoic acids.

Stimulated by the commercial availability of bacteriologically produced polyesters such as poly[(R)-3-hydroxybutyric acid], and encouraged by the discovery of new constituents of polyhydroxyalkanoic acids (PHA), a considerable body of knowledge on the metabolism of PHA in microorganisms has accumulated. The objective of this essay is to give an overview on the biodegradation of PHA. The following topics are discussed: (i) general considerations of PHA degradation, (ii) methods for identification and isolation of PHA-degrading microorganisms, (iii) characterization of PHA-degrading microorganisms, (iv) biochemical properties of PHA depolymerases, (v) mechanisms of PHA hydrolysis, (vi) regulation of PHA depolymerase synthesis, (vii) molecular biology of PHA depolymerases, (viii) influence of the physicochemical properties of PHA on its biodegradability, (ix) degradation of polyesters related to PHA, (x) biotechnological aspects of PHA and PHA depolymerases.

Amino Acid Sequence↗

Precoating of alloplastic materials with living human fibroblasts--a feasibility study.

BACKGROUND: The use of alloplastic materials such as polypropylene and polyester has reduced the recurrence of abdominal wall hernias. Concomitantly, new problems have arisen such as inflammatory response against the implanted material and the development of enteric fistulas in case of direct contact of the bowel to polypropylene and polyester. A precoating of the PP with collagen and other absorbable materials seems to reduce the incidence of adhesions and fistulas. The aim of this study was to show the technical feasibility of a precoating of polypropylene with living human fibroblasts and to investigate the growth properties of the cells under these conditions in vitro. METHODS: The textile structure of three different alloplastic materials is described (SurgiPro), TycoHealthcare; Parietene3 PP1510, Dallhausen; VIPRO II, Ethicon Endosurgery). Enhanced Green Fluorescence Protein (EGFP) transduced human foreskin fibroblasts (KiF5) were seeded onto these different alloplastic materials. Proliferation was analyzed by FACS analysis of Ki67 expression. The coating process of the whole mesh area was observed over time with UV-light microscopy, immunostaining, and scanning electron microscopy (SEM). The expression of collagen type I and III was investigated by immunostaining. RESULTS: The three alloplastic materials used were knitted fabrics with different textile structures. KiF5 colonized the entire alloplastic material within 4-6 weeks. Cells were proliferating, as detected by Ki67 expression. SEM showed surface ruffles and long cellular extensions, indicating an active cell metabolism. Light microscopy and SEM suggested that the cells modify the apolar surface by deposition of extracellular matrix components before colonization. CONCLUSION: Our study shows the feasibility of precoating of polypropylene meshes with living human fibroblasts and opens the possibility for clinical use in the future.

Cells, Cultured↗

Biomechanical comparisons of anterior cruciate ligament: reconstruction procedures with flexor tendon graft.

An experimental study was conducted to compare the biomechanical characteristics of six currently available anterior cruciate ligament (ACL) reconstruction procedures with flexor digitorum profundus tendons. Forty porcine knees were divided into eight groups, of 5 knees each. In groups A, B, C, and D, the flexor tendon graft was fixed with sutures and an Endobutton, with 20-mm-wide polyester tapes and staples, with 10-mm-wide polyester tapes and an Endobutton, and with bone plugs and interference screws, respectively. In group E, the graft was fixed using a combined procedure of those in groups B and D. In group F, the graft was directly fixed with interference screws. In groups G and H, the bone-patellar tendon-bone graft was fixed with interference screws, and sutures, respectively. Each femur-graft-tibia complex specimen was tested with a tensile tester by anteriorly translating the tibia until failure. This study demonstrated that the biomechanical properties of the femur-graft-tibia complex reconstructed with the flexor tendon graft were significantly affected by synthetic fixation devices. Regarding the average maximal load of the groups with the flexor tendon graft, group B had the highest (893 N) and group C had the second highest (770 N). Groups E and A were in the third rank. Group F had the second lowest (312 N), and Group D had the lowest (230 N). The maximal load of group B was significantly greater (P < 0.01) than that of group G (656 N) with the bone-patellar tendon-bone grafts. As to clinical relevance, this study indicated that the flexor tendon graft can be an alternative substitute for the bone-patellar tendon-bone graft for ACL reconstruction, if we understand the biomechanical characteristics of each reconstruction procedure.

Animals↗

Endovascular treatment of aortoiliac aneurysms: made-to-measure stent-grafts increase feasibility.

We describe here our preliminary experience with use of a range of made-to-measure stent-grafts made from commercially available components. From January 1996 to June 1998, 94 aortoiliac aneurysms (AIA) were treated with stent-grafts that were made to measure using Z autoexpandable stainless steel stents connected with polyester sutures and covered with commercially available polyester vascular prostheses. These stent-grafts were implanted through 18 to 24 (typically 20) Fr commercially available introducers via a surgical remote access. Made-to-measure tubular, bifurcated, tapered, and/or blind stents combined with extraanatomic bypass designs increased the rate of endovascular treatment (ET) of AIA in this series. This rate was further increased through the use of uncovered proximal or distal stents when dealing with short or tortuous necks near major collaterals and through use of hybrid, partly surgical designs, one with stented and the other with stentless ends, the latter allowing for a surgically made anastomosis. The results of our experience with these techniques show that use of made to-measure stent-grafts greatly increases the feasibility of the ET of AIA among unselected patients while offering enough efficiency and safety to deserve further investigation.

Aortic Aneurysm, Abdominal↗

Characterization and performance of constructed nitrifying biofilms during nitrogen bioremediation of a wastewater effluent.

Constructed ammonium oxidizing biofilms (CAOB) and constructed nitrite oxidizing biofilms (CNOB) were characterized during the bioremediation of a wastewater effluent. The maximum ammonium removal rate and removal efficiency in CAOB was 322 mg N-NH4+ m(-3) d(-1) and 96%, respectively, while in CNOB a maximum removal rate of 255 mg N-NH4+ m(-3) d(-1) and a removal efficiency of 76% was achieved. Both constructed biofilms on low-density polyester Dacron support achieved removal efficiencies higher than that of the concentrations normally present in reactors without constructed biofilms (P < 0.05). Nitrifying bacteria from the constructed biofilms cultures were typed by sequencing 16S rRNA genes that had been amplified by PCR from genomic DNA. Analysis of enrichment biofilms has therefore provided evidence of high removal of ammonium and the presence of Nitrosomonas eutropha, N. halophila and N. europaea in CAOB, while in CNOB Nitrobacter hamburgensis, N. winogradskyi and N. alkalicus were identified according to 16S rRNA gene sequences comparison. The biofilm reactors were nitrifying over the whole experimental period (15 days), showing a definite advantage of constructed biofilms for enhancing a high biomass concentration as evidenced by environmental electron microscopic analysis (ESEM). Our research demonstrates that low-density polyester Dacron can be effectively used for the construction of nitrifying biofilms obtaining high removal efficiencies of nitrogen in a relatively short time from municipal effluents from wastewater treatment plants. CAOB and CNOB are potentially promissory for the treatment of industrial wastewaters that otherwise requires very large and expensive reactors for efficient bioremediation of effluents.

Bacteria↗

Supramolecular surfactants: amphiphilic polymers designed to disrupt lipid membranes.

Simple polyesters derived from poly(ethylene glycol)s and alpha, omega-dicarboxylic acids exhibit a broad range of activity in disrupting phospholipid membranes. This activity has been analyzed by measuring the release of liposome-encapsulated 5(6)-carboxy-fluorescein (CF). Comparison with an analogous monomeric surfactant, and with Triton X-100, demonstrates that macromolecular activity is a sensitive function of the size of the hydrophobic and hydrophilic segments within each repeat unit, and that high disrupting power is possible. In vitro studies with the human immunodeficiency virus type-1 have revealed that those polyesters which exhibit the highest membrane disrupting power also provide significant protection for human CD4+ lymphocytes against HIV-1. The potential for adjusting and utilizing these "supramolecular surfactants" in medicine is briefly discussed.

HIV-1↗

Radiographic assessment of splinting bandages.

The physical attenuation of X-rays by a variety of splinting bandages was measured and compared with the subjective opinion of nine radiologists. The radiolucency of the bandages and their interference with the interpretation of bony detail on radiographs (using a radiographic knee phantom) was assessed. Plaster-of-Paris (POP) bandages produced the greatest attenuation of X-rays and the greatest interference with interpretation of bony detail. All the polyurethane resin impregnated fabric bandages produced less attenuation than POP, but variations occurred due to the fabric type and knit of the bandage. The lowest attenuation occurred in those bandages using cotton, polyester or polypropylene fabric, and in all but one instance these caused least interference in radiographic interpretation. The exception was the polyester bandage, where the coarse knit of the fabric produced a large difference in X-ray beam absorption between the air spaces and the bandage. The distracting mesh pattern on the radiograph interfered with radiographic visualization. The glass fibre bandages caused intermediate attenuation, being better than POP but not as radiolucent as the non-glass fabrics.

Bandages↗

New haemocompatible polymers assessed by thrombelastography.

Mimicry of the nonthrombogenic surface of the erythrocyte has been advocated as the starting point for the development of nonthrombogenic biomaterials. Phosphorylcholine forms 88% of the outer surface of the erythrocyte, and so materials containing it should be nonthrombogenic. We have evaluated the thrombogenicity of such materials and compared them with Dacron and PTFE. Three materials containing phosphorylcholine were used: a naturally occurring phospholipid (dipalmitoylphosphatidylcholine, DPPC), a polymerized phospholipid (diacetylenic phosphatidylcholine, DAPC) and a polyester polyurethane (Polyester G). The thrombogenic potential of these materials was assessed by material thrombelastography (MTEG). This technique uses human whole blood at 37 degrees C, without an air interface, and records the elasticity of the blood clot produced. Since each material is evaluated with a control surface, extraneous differences due to factors other than the test material are eliminated. Analysis, and examples of the MTEG traces are shown and discussed. The phosphorylcholine containing materials were found to have a reduced amount of clotting factor activation, but only DPPC was better than Dacron and PTFE. MTEG demonstrated the known thrombogenicity of Dacron towards platelets. A striking reduction in platelet activation was shown for the three phosphorylcholine containing materials. These three materials show only 25% of the platelet activation of PTFE. These materials warrant further investigation as potentially very useful biomaterials.

Biocompatible Materials↗

Interaction of macrophages with fibrous materials in vitro.

Fibrous materials have the potential of being used for tissue scaffolding. The interaction of macrophages with fibres of various compositions and sizes was observed in vitro. The following materials were tested: individual gold fibres; woven fibres of polyester and nylon; non-woven fibres of polybutylene/polypropylene 80:20 and polyester. All fibres had diameters between 2 and 40 microns. At the end of the 24 h incubation time, culture media were retrieved for the assay of tumour necrosis factor alpha (TNF-alpha) and interleukin-6 (IL-6), two cytokines secreted by activated macrophages. Fibre samples were processed for scanning electron microscopy (SEM), or for immunofluorescence labelling of the MAC-1 and ICAM-1 cell surface markers. Confocal microscopy was used for the latter, which was performed with the woven and non-woven samples. None of the fibre samples induced significant amounts of TNF-alpha or IL-6 secretion in the culture medium, suggesting that the cells did not activate this pathway. SEM on individual gold fibres showed that the fibre diameter had an effect on the morphology of the cells, namely on their extent of spreading. Larger fibres had a higher number of cells, which tended to cluster together without spreading extensively. When comparing woven and non-woven fibres, SEM showed that cells spread extensively on the woven fibres, whereas they tended to maintain their spherical shape on the non-woven fibres. Confocal microscopy demonstrated a difference between materials in the number of MAC-1 and ICAM-1 positive cells. These results demonstrate that a combination of morphological, immune and biochemical markers can be used to distinguish the response of elicited macrophages to various materials. The cells appeared to be only moderately activated on all materials tested, with changes in their morphology but without increased secretion of cytokines. The measured responses imply interactions between nominal fibre composition and fibre diameter.

Animals↗

An evaluation of suture materials used in tendon surgery.

The following suture materials have been evaluated for their suitability for use in flexor tendon repairs: 4/0 gauge monofilament and multifilament stainless steel, mono-filament nylon, monofilament polypropylene, monofilament polybutestor, braided polyester, braided polyglycolic acid and a monofilament polyglyconate. These were investigated for their tensile strength (both knotted and unknotted), their extension to failure and knot-holding properties. Stainless steel and monofilament polyglyconate appeared to be the most suitable in that they had high tensile strengths, both knotted and unknotted, and had good knot-holding security. The only disadvantages are that stainless steel is difficult to use and monofilament polyglyconate is absorbable. Polypropylene and braided polyester, although having lower tensile strengths, are reasonable alternatives.

Humans↗

A "room-temperature" injection molding/particulate leaching approach for fabrication of biodegradable three-dimensional porous scaffolds.

A "room-temperature" injection molding approach combined with particulate leaching (RTIM/PL) has been, for the first time, developed in this work to fabricate three-dimensional porous scaffolds composed of biodegradable polyesters for tissue engineering. In this approach, a "wet" composite of particulate/polymer/solvent was used in processing, and thus the injection was not performed at melting state. Appropriate viscosity and flowability were facilely obtained at a certain solvent content so that the composite was able to be injected into a mould under low pressure at room temperature, which was very beneficial for avoiding thermal degradation of polyesters. As a demonstration, tubular and ear-shaped porous scaffolds were fabricated from biodegradable poly(D,L-lactide-co-glycolide) (PLGA) by this technology. Porosities of the resulting scaffolds were as high as 94%. The pores were well interconnected. Besides the well-known characteristics of injection molding to be suitable for automatization of a fabrication process with high repeatability and precision, this RTIM/PL approach is much suitable for tailoring highly porous foams with its advantages flexible for shaping complicated scaffolds, free of thermal degradation and high-pressure machine, etc.

Biocompatible Materials↗