PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Robotics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

[Automatic collection system of waste scintillator solution using micro robots].

Industrial micro-robots are now being applied to hazardous jobs or tedious jobs. These in-house micro-robots (MELFA, RM-501, Mitsubishi Electric Inc.) were used to make a collection system of waste scintillator solution on the experimental basis. Newly developed were hands, vial holders and a system soft ware, and satisfactory results have been obtained.

Automation↗

Robotics and allied technologies in endoscopic surgery.

The human hand-arm system provides seven degrees of freedom for the manipulation of objects in space. In open surgery these motion axes can be used fully when guiding the surgical instrument. In endoscopic procedures the surgical instrument is fixed to the point of trocar insertion, resulting in only four degrees of freedom. This leads to a loss of instrumental functionality in endoscopic procedures. Robotics and telemanipulator technology can be used to restore the full spatial mobility of the endoscopic instrument. A functional model of an endoscopic master-slave manipulator system has been developed and is under experimental surgical evaluation. Allied technologies include new tactile sensor and vision systems that can enhance the application of robotic systems in surgery for the future.

Journal Article↗

Practical haptic navigation with clickable 3D region input interface for supporting master-slave type robotic surgery.

Conventional display in robotic surgery such as flat displays or stereoscopic displays decreases obtainable information around target tissue. For supporting manipulation and performing safe surgery, this paper proposes a haptic navigation method, which enables surgeons to avoid collision with untouchable regions around target tissue by producing force feedback through a master manipulator. This paper also developed an input interface for assignment of 3D untouchable regions through 2D device. Simulator based experiment clears effectiveness of the proposed haptic navigation for improving safety of robotic surgery.

Humans↗

Robotic automation of cyclosporine analysis in whole blood.

Cyclosporin A (CsA) is currently the most selective immunosuppressant used clinically to prevent organ rejection after transplantation. We used a reprogrammable robot, the Benchmate (Zymark Inc., Hopkinton, MA), to automate much of the sample preparation involved in solid-phase extraction of CsA. Lysed whole-blood specimens containing previously added internal standard were placed on the Benchmate in the specimen-holding area, and a C18 Bond-Elut column was placed in the top of the sample tube. Specimen extraction from this point was handled automatically by the Benchmate, after which we manually injected the sample into the HPLC system for quantification. Analytical recovery of CsA in two concentrations of calibrator was similar for the manual and Benchmate methods. Analytical imprecision for the Benchmate was less than for manual extraction: within-run imprecision (CV) was less than 8% at either concentration. Between-run imprecision, determined by having the Benchmate extract CsA from two specimens each day for 20 days, was less than 9%. Patients' specimens were extracted manually (x) or by using the Benchmate robot (y); the results, compared by linear regression, agreed well: (y = 0.99 (SD 0.02)x + 2.6 (SD 2.8) micrograms/L (Sy[x = 7.59 micrograms/L, n = 27). We conclude that the Benchmate usefully reduces the manual steps necessary to extract specimens before HPLC analysis for CsA.

Autoanalysis↗

Telemedicine and surgical robotics: urologic applications.

Medical treatment can be improved through integration and application of advances in technology, computers, and engineering. Accuracy and reliability are essential characteristics of any mechanical system, and with the evolution of machines capable of precise movements, the integration of medicine and machine is achievable. Early mechanical devices were effective in performing simple, repetitive tasks but were not sophisticated enough for independent function. In the automobile industry, robots could work on the assembly line executing these cyclic tasks. These machines could execute simple, reiterative movements without integrating new information from the environment. In this day and age, robots have evolved into sophisticated mechanical devices that can "react" to data detected in the environment to determine the next course of events. They have evolved from the assembly line to the operating room, assisting surgeons during surgery to participating in remote telesurgical procedures.

Journal Article↗

Management of clinically localized prostate cancer: pathologic processing to robotic prostatectomy.

Prostate cancer management has undergone significant changes in recent years. The existing modalities are being refined, and a better understanding of pathologic parameters is helping in decision making. Newer sources of energy can be used to kill cancer cells, and modern robots are lending a helping hand in surgical removal of prostate cancer. The 13th International Prostate Cancer Update meeting provided a unique opportunity to review these recent developments. Reviewed here are highlights of presentations addressing recent developments in the surgical management of prostate cancer. The first discussion involved the processing of surgical specimens and interpretation of information obtained from histopathologic analysis. The second topic discussed here focused on an ongoing randomized trial comparing surgery with watchful waiting in the management of clinically localized prostate cancer. The last detailed presentation covered robotic prostatectomy and compared it with conventional open radical prostatectomy.

Journal Article↗

Application of robotics to radiopharmaceutical preparation: controlled synthesis of fluorine-18 16 alpha-fluoroestradiol-17 beta.

A commercially available robot system, the Zymark Zymate Laboratory Automation System, has been utilized for the preparation of a positron-emitting radiopharmaceutical, 16 alpha-[18F] fluoroestradiol-17 beta. This radiopharmaceutical is prepared in a three-step synthesis (preparation of [18F]-tetrabutylammonium fluoride, SN2 displacement of a triflate, and ketone reduction) and is purified by high performance liquid chromatography (HPLC). All steps in the synthesis and HPLC purification are controlled by the robot system with no manual intervention. This represents a new approach to the complete automation of radiopharmaceutical production.

Automation↗

[Percutaneous puncture with a robot].

The great advances of microelectronics and mechatoronics are gradually being applied into medicine. In percutaneous nephrostomy, it is possible to calculate the depth and direction of the needle by using a computer if one point on the surface of the skin and another point in the dilated renal pelvis are determined. When a robot is moved according to the computed results, a percutaneous operation is performed fast and exactly. We established a system through which a percutaneous operation is automatically performed. The following technical difficulties of this system were overcome. The coordinates of the two points for a percutaneous operation were input into a computer through a CRT display. Machine language of the Z-80 CPU was used for the programming. A program package enabling fast calculation was developed. The shape of the robot was calculated and shown on the CRT display before it showed any movements.

Automation↗

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d = 2.381 mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44 mm (95% CI, 4.02-6.86 mm; p = 2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p = 5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p = 0.26) or cognitive workload via the NASA-Task Load Index (p = 0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures↗

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans↗

Perioperative safety and survival outcomes of robot-assisted partial nephrectomy in elderly patients with localized renal cell carcinoma: an overlap-weighted Asian cohort study.

The value of robot-assisted partial nephrectomy (RAPN) in elderly Asian patients with localized renal cell carcinoma (RCC) remains insufficiently defined. We retrospectively analyzed 339 patients (&#x2265;&#x2009;70 years) with localized RCC treated at a single Asian center between 2015 and 2025, including 119 undergoing partial nephrectomy (PN) and 220 undergoing radical nephrectomy (RN). Propensity score overlap weighting (OW) was applied to compare PN versus RN and, within the PN cohort, RAPN versus laparoscopic partial nephrectomy (LPN). Three open partial nephrectomy cases were summarized descriptively and retained only in exploratory sensitivity analyses. Weighted logistic regression and Cox models with robust standard errors evaluated Clavien-Dindo grade&#x2009;&#x2265;&#x2009;II complications and overall survival (OS). After OW, PN was associated with better early postoperative renal functional preservation than RN but a greater incidence of grade&#x2009;&#x2265;&#x2009;II complications (36.4% vs. 17.6%; weighted p&#x2009;<&#x2009;0.001); OS was similar. Within the PN cohort, RAPN had longer operative time than LPN (weighted p&#x2009;=&#x2009;0.030), whereas warm ischemia time, early postoperative eGFR, and grade&#x2009;&#x2265;&#x2009;II complications (31.8% vs. 40.4%; weighted p&#x2009;=&#x2009;0.414) were not significantly different. Exploratory analyses favored RAPN, but only one death occurred in this group, and residual confounding remains possible. PN may preserve early renal function in selected older patients, while RAPN appears feasible in experienced centers; its survival association remains hypothesis-generating.

Humans↗

Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.

Robot-assisted percutaneous vascular intervention (R-PVI) has expanded beyond coronary procedures, but previous reviews were largely coronary-focused and observational. Recent randomized controlled trials (RCTs) warrant broader reassessment of R-PVI versus manual percutaneous vascular intervention (M-PVI) across vascular territories. PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials were searched from database inception to January 31, 2026, following PRISMA guidelines. RCTs and observational studies including &#x2265;10 adult patients in total were eligible. Comparative studies informed primary analyses, while single-arm studies provided supportive evidence. Primary outcomes were clinical success rate and major adverse cardiovascular/cerebrovascular events (MACE) rate. Secondary outcomes included mortality rate, technical success rate, procedural time metrics, contrast volume, and radiation exposure. Random-effects models were used. Forty studies were included: 3 RCTs, 10 comparative observational studies, and 27 single-arm observational studies, comprising 3,870 patients undergoing R-PVI and 1,142 undergoing M-PVI. Comparative analyses showed similar clinical success rates (RR 1.00, P = 0.46), MACE rates (RR 0.72, P = 0.43), and mortality. Single-arm pooled estimates for clinical and technical success were 98.76% and 96.09%, respectively. R-PVI prolonged total procedure time overall (MD 15.92&#xa0;min, P = 0.01), with consistent increases in the neurovascular, RCT, and non-RCT subgroups. Fluoroscopy time was also longer (MD 1.91&#xa0;min, P = 0.04), mainly in the RCT subgroup (MD 2.83&#xa0;min, P = 0.001). In contrast, intravascular intervention time was unchanged overall and in RCTs, but was prolonged in non-RCTs (MD 8.72&#xa0;min, P = 0.006). Operator radiation exposure was markedly reduced (MD -33.97 &#x3bc;Sv, P < 0.001), whereas patient radiation exposure and contrast volume were similar. R-PVI appears feasible and safe across selected vascular procedures. Its clearest benefit is reduced operator radiation exposure, whereas lower whole-procedure efficiency remains its main limitation.

Humans↗

Sutureless versus renorrhaphy in robot-assisted off-clamp partial nephrectomy: a systematic review and meta-analysis.

BACKGROUND: The necessity of routine parenchymal renorrhaphy during off-clamp robot-assisted partial nephrectomy (RAPN) remains uncertain. This study aimed to compare perioperative, functional, safety, and oncological outcomes between sutureless and conventional renorrhaphy. METHODS: We conducted a systematic review and meta-analysis following PRISMA 2020 guidelines. Comparative studies evaluating sutureless versus conventional renorrhaphy during purely off-clamp RAPN were included. Trifecta achievement was the primary outcome. Random-effects models were used for pooled analyses, with subgroup analysis according to study design. RESULTS: Four studies involving 787 patients, including one randomized controlled trial (RCT) and three propensity score-matched (PSM) studies, were included. The overall pooled estimate showed no statistically significant difference in Trifecta achievement (RR 1.17, 95% CI 0.97-1.41), with substantial heterogeneity (I&#xb2; = 86.5%). The PSM studies favored the sutureless approach (RR 1.26, 95% CI 1.05-1.52), whereas the RCT yielded an RR of 0.97 (95% CI 0.92-1.04) and met the prespecified noninferiority criterion without demonstrating superiority. The sutureless approach was associated with a smaller perioperative eGFR decline (MD&#x2009;-&#x2009;3.89, 95% CI&#x2009;-&#x2009;6.16 to -&#x2009;1.62), while no significant difference was observed in eGFR at 3 months. No statistically significant differences were identified in major complications, blood transfusion, or positive surgical margins; urinary and vascular complications were sparsely reported. CONCLUSIONS: In selected patients undergoing purely off-clamp RAPN, randomized evidence supports the noninferiority of a strategy that omits routine parenchymal renorrhaphy while permitting clinically necessary selective repair, but does not demonstrate superiority. Favorable estimates from PSM studies remain vulnerable to intraoperative treatment-selection bias. Current evidence is insufficient to determine whether omission of renorrhaphy affects urinary complications, long-term renal function, or oncological outcomes. REGISTRATION: This systematic review was registered prospectively in PROSPERO (CRD420261435995).

Humans↗

Effectiveness of passive vs. assistive robotic gait training on functional recovery and neuroplasticity post-stroke: A randomized controlled trial.

OBJECTIVE: This study seeks to compare the impacts of various robotic gait training (RAGT) modes on lower limb motor function recovery in stroke patients while exploring the corresponding neural mechanisms. DESIGN: A single-blind, randomized controlled trial. SETTING: Inpatient Rehabilitation Facility. PARTICIPANTS: Forty-eight patients aged 18-80 who had experienced their first unilateral subacute stroke accompanied by walking impairments were included. INTERVENTIONS: Participants were randomly assigned to: (1) assistive mode training, (2) passive mode training, or (3) control group receiving only traditional rehabilitation. Clinical and neurological outcomes were assessed at pre-intervention (T0), and post-2-week intervention (T1). MAIN OUTCOME MEASURES: Outcomes were evaluated using the Fugl-Meyer Assessment for Lower Extremity, Berg Balance Scale, Modified Barthel Index, the Functional Ambulatory Category, and functional near-infrared spectroscopy. RESULTS: Among the 48 patients recruited, significant time effects were observed across all groups in FMA-LE scores (p&#x202f;<&#x202f;0.001). Notable improvements were detected in the conventional group (MD = 2.69, p&#xff1c;0.01) and the passive group (MD = 3.67, p&#x202f;<&#x202f;0.001), with the assistive mode also demonstrating a significant effect (MD = 1.79, p&#x202f;<&#x202f;0.05). BBS scores improved across all groups; however, no significant differences were noted between the groups (p&#x202f;=&#x202f;0.11). Similarly, MBI scores showed a significant time effect (p&#x202f;<&#x202f;0.001), without notable group differences (p&#x202f;=&#x202f;0.29). CONCLUSION: All training modalities effectively enhanced motor function, balance, and daily living skills in stroke patients. Distinct cortical activation and connectivity patterns were observed between training modalities, which may reflect different neuroplastic mechanisms. These preliminary neural differences may help inform personalized rehabilitation strategies, although no clinical superiority of one mode over another can be concluded from the present data.

Humans↗

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans↗

Minimally invasive and robotic surgery.

Advances in surgery have focused on minimizing the invasiveness of surgical procedures, such that a significant paradigm shift has occurred for some procedures in which surgeons no longer directly touch or see the structures on which they operate. Advancements in video imaging, endoscope technology, and instrumentation have made it possible to convert many procedures in many surgical specialties from open surgeries to endoscopic ones. The use of computers and robotics promises to facilitate complex endoscopic procedures by virtue of voice control over the networked operating room, enhancement of dexterity to facilitate microscale operations, and development of virtual simulator trainers to enhance the ability to learn new complex operations. Future research will focus on delivery of diagnostic and therapeutic modalities through natural orifices in which investigation is under remote control and navigation, so that truly "noninvasive" surgery will be a reality.

Forecasting↗

Chemotyping of yeast mutants using robotics.

By now, the EUROFAN programme for the functional analysis of genes from the yeast genome has attained its cruising speed. Indeed, several hundreds of yeast mutants with no phenotype as tested by growth on standard media and no significant sequence similarity to proteins of known function are available through the efforts of various laboratories. Based on the methodology initiated during the pilot project on yeast chromosome III (Yeast 13, 1547-1562, 1997) we adapted it to High Throughput Screening (HTS), using robotics. The first 100 different gene deletions from EUROSCARF, constructed in an FY1679 strain background, were run against a collection of about 300 inhibitors. Many of these inhibitors have not been reported until now to interfere in vivo with growth of Saccharomyces cerevisiae. In the present paper we provide a list of novel growth conditions and a compilation of 49 yeast deletants (from chromosomes II, IV, VII, X, XIV, XV) corresponding to 58% of the analysed genes, with at least one clear and stringent phenotype. The majority of these deletants are sensitive to one or two compounds (monotropic phenotype) while a distinct subclass of deletants displays a hyper-pleiotropic phenotype with sensitivities to a dozen or more compounds. Therefore, chemotyping of unknown genes with a large spectrum of drugs opens new vistas for a more in-depth functional analysis and a more precise definition of molecular targets.

Antifungal Agents↗

Robot-assisted microscope for neurosurgery.

We describe the implementation of a robotic arm connected to a neurosurgical operative microscope. A force feedback sensor drives the motors of the arm in response to the positioning of the microscope by the surgeon. Computer graphic techniques allow tracking of the current position of the microscope within the volumetric reconstruction of the brain. The integration of the prototype into the neurosurgical operating room is currently being evaluated. Preliminary comments on this experimental phase are offered.

Angiography, Digital Subtraction↗