PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microbubbles”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77Linked to original sources

[The effect of carvedilol on contrast echocardiography in comparison to metoprolol in conscious dogs].

This animal study was to demonstrate the effect of the betablockers carvedilol (CAS 72956-09-3) and metoprolol (CAS 37350-58-6), respectively, on myocardial perfusion which was quantified by the use of contrast echocardiography. Each of four experimental schemes were applied consecutively to each of six dogs. They were pretreated with oral administration of either carvedilol (2 mg/kg b. wt.) or with metoprolol (4 mg/kg b. wt.), or received no premedication. 2 h later the contrast agent BY963 (0.03 ml/kg)--a new transpulmonary contrast agent for sonography, based on phopspholipid stabilized microbubbles--was injected intravenously three times at intervals of 2.5 min 5 min in advance and 7.5, 10, 20, and 30 min following the first injection 60 digitized echocardiography images were recorded during a time period of each 2.9 s. From these images average grey-scale values at predetermined points of time were derived. Time-intensity curves of the region of interest of the interventricular septum were computed. Changes in intensity were calculated by baseline subtraction. Myocardial opacification was observed with all injections of the contrast agent in each dog. The effects were marked and no non-responder was observed. There was no return to baseline grey-scale values within the observation period (30 min). Pretreatment with carvedilol was followed by a more pronounced contrast intensity than was with metoprolol. All administrations were well tolerated. No changes in ECG were observed. Heart rate decrease was marked on metoprolol. Blood pressure dropped to a greater extent on carvedilol compared to metoprolol.

Adrenergic beta-Antagonists↗

[Stimulated acoustic emissions with the ultrasound contrast medium levovist: a clinically useful contrast effect with liver-specific properties].

PURPOSE: The purpose of this study was systematically to investigate stimulated acoustic emission (SAE) with the microbubble contrast agent Levovist (Schering AG, Berlin) in vivo with regards to reproducibility, distribution in various organs over time, dependence on technical factors, and influence on the delineation of focal liver lesions. PATIENTS AND METHODS: 2 intravenous injections of 1 g of Levovist were given to 2 dogs and 1-6 injections of 2.5 g Levovist to 5 healthy volunteers and 37 patients. The liver, spleen, large abdominal vessels, and kidney were intermittently scanned for up to 30 min. Studies were evaluated for the presence of SAE signals by 2 observers. In 20 patients with focal liver lesions (15 with metastases, 4 haemangiomata, 1 hepatocellular carcinoma, and 1 cyst) the influence on lesion visualization was also assessed. RESULTS: SAE effects, lasting up to 30 minutes, were seen in all subjects in the liver and spleen. Vascular and renal SAE signals were noted shortly after injection, lasting up to 6 minutes. SAE was absent or markedly reduced in focal liver lesions, which were seen as colour voids. This increased the conspicuity of focal lesions, and in 5 patients additional metastases were detected that could not be delineated on B-mode alone. CONCLUSION: A liver- and spleen-specific late phase of Levovist can be consistently demonstrated using SAE and the effect increases the conspicuity of focal liver lesions.

Adult↗

[Characterization of focal liver lesions with contrast-enhanced low MI real time ultrasound and SonoVue].

PURPOSE: SonoVue is a new microbubble ultrasound contrast agent that for the first time allows continuous real time examination during the different phases of contrast enhancement using low transmission power, expressed as mechanical index (MI). This study investigates whether low MI real time phase inversion imaging with SonoVue can improve the characterization of focal liver lesions in comparison to unenhanced sonography and power Doppler sonography. MATERIALS AND METHODS: Sixty-three patients with 35 malignant and 28 benign liver lesions were studied with unenhanced ultrasound (US) including B-mode and power Doppler, followed by contrast-enhanced al MI (0.1 - 0.3) real time phase inversion US during arterial, portal-venous and delayed liver phase (> 2 min after injection). Findings of the scans obtained before and after administration of contrast agent were compared with each other and with reference examinations (biopsy, MRI, CT or intraoperative US). RESULTS: The number of correctly diagnosed lesions increased from 41 (65%) without contrast agent to 58 (92%) with contrast agent (p < 0.001). The differentiation of malignant from benign lesions improved from 43 (68 %) to 60 (95 %, p < 0.001). After administration of the contrast agent, all 35 malignant lesions were correctly recognized and 3 of the 28 benign lesions were misclassified. All 27 metastases showed little or no enhancement on portal-venous and delayed phase imaging, independent of their arterial features. All 6 hepatocellular carcinomas (HCC) enhanced markedly during arterial phase and 5 showed less contrast uptake than normal liver in the late phase. Ten of 11 hemangioma displayed arterial peripheral nodular enhancement followed by progressive centripetal fill-in. Nine of 11 focal nodular hyperplasias (FNHs) showed profuse arterial enhancement (5 with a transient "spokewheel") and contrast uptake similar to normal liver thereafter. One FNH showed a subtle central scar. CONCLUSION: Low MI real time US with SonoVue markedly improves the characterization of focal hepatic lesions in comparison with unenhanced sonography.

Adult↗

Contrast-enhanced sonographic detection of vesicoureteral reflux in children: comparison with voiding cystourethrography.

PURPOSE: Prospective evaluation of contrast-enhanced sonography (CES) as an alternative to radiographic voiding cystourethrography (VCUG) in the detection of vesicoureteral reflux (VUR). MATERIALS AND METHODS: Seventy-six children (age range: 0 - 9 years, mean age 1.4 years) with suspicion of VUR due to various indications were examined by contrast-enhanced sonography (CES) and VCUG. CES examination was performed after instillation of Levovist into the catheterized urinary bladder, which had been prefilled with normal saline. Reflux was diagnosed when hyperechogenic microbubbles were observed in the renal units. Thereafter, VCUG was performed in all patients through the same catheter. CES findings were compared to the results of VCUG. RESULTS: CES showed VUR in 24 renal units whereas VCUG showed reflux in 18 renal units. With regard to the presence of VUR, the findings obtained by both methods were concordant in 17 renal units. Taking VCUG as the reference standard, the sensitivity of CES was 96 %, the specificity was 94.8 %, the positive predictive value 77.4 % and the negative predictive value 99.2 %. Additionally, McNemar test showed that CES detected a statistically significant higher number of renal units with VUR (p < 0.05). CONCLUSION: It is suggested that CES is an accurate and reliable imaging modality for the detection of VUR, although it cannot replace VCUG in some cases. In addition, CES can be recommended in the follow-up of VUR, reducing the number of radiographic investigations.

Age Factors↗

Brain magnetic resonance imaging, aerobic power, and metabolic parameters among 30 asymptomatic scuba divers.

The aim of the study was to evaluate the presence of cerebral lesions in asymptomatic scuba divers and explain the causes of them: potential risk factors associating cardiovascular risk factors, low aerobic capacity, or characteristics of diving (maximum depth, ascent rate). Experienced scuba divers, over 40 years of age, without any decompression sickness (DCS) history were included. We studied 30 scuba divers (instructors) without any clinical symptoms. For all of them, we carried out a clinical examination with fatty body mass determination and we questioned them about their diving habits. A brain Magnetic Resonance imaging (MRI), an assessment of maximal oxygen uptake, glycemia, triglyceridemia, and cholesterolemia were systematically carried out. Cerebral spots of high intensity were found at 33 % in the scuba diving group and 30 % in the control group. In the diving group, abnormalities were related to unsafe scuba-diving or metabolic abnormalities. In our study, we did not find a significant relationship between the lesions of the central nervous system, and the age, depth of the dives, number of dives, and ergometric performances (maximal oxygen uptake, V.O (2max), serum level of blood lactate). Nevertheless, we found a significant relationship between the lesions of the central nervous system and ascent rate faster than 10 meters per minute (r = 0.57; p = 0.003) or presence of high level of cholesterolemia (r = 0.6; p = 0.001). We found concordant results using the Cochran's Test: meaningful link between the number of brain lesions and the speed of decompression (Uexp = 14 < Utable = 43; alpha = 0.05, p < 0.01). We concluded that hyperintensities can be explained by preformed nitrogen gas microbubbles and particularly in presence of cholesterol, when the ascent rate is up to 10 meters per minute. So, it was remarkable to note that asymptomatic patients practicing scuba diving either professionally or recreationally, presented lesions of the central nervous system. This survey permitted us to highlight in a population of professional divers, neurological and also cardiovascular abnormalities (ventricular arrhythmias); although none of them present any symptoms today. It seems therefore important to us to propose in the future, for a better prevention of neurological injuries, a systematic follow-up by maximal oxygen consumption measure, brain MRI, and cholesterolemia. In the same way, our results suggest a modification of the diving tables with a maximal decompression rate at 9 m . mn (-1).

Brain↗

Contrast-enhanced sonography for the characterisation of hepatocellular carcinomas--correlation with histological differentiation.

AIM: We aimed to characterise the vascularisation patterns of hepatocellular carcinomas in contrast-enhanced sonography in correlation to the histological differentiation of hepatocellular carcinomas (HCC), and we also compared the diagnostic value of contrast-enhanced sonography in addition to B-scan sonography and power Doppler sonography. METHODS: 51 hepatocellular carcinomas (21 well differentiated, 27 moderately differentiated, 3 poorly differentiated) were examined: by B-scan sonography, power Doppler sonography and contrast-enhanced sonography using phase or pulse inversion harmonic imaging with a low mechanical index (< 0.3) and second generation microbubble contrast medium (Optison, Sonovue) as echo-enhancing agent. Lesion vascularity and the kinetics of contrast enhancement within the lesions in the early arterial phase, arterial phase, portal phase and late phase were analysed. The final diagnosis of a HCC was assessed after B-scan sonography, power Doppler sonography and contrast-enhanced sonography. RESULTS: Hypervascularisation and/or irregular tumour vascularisation could be detected in 18/48 HCCs (37.5%) by power Doppler sonography. After contrast application, 46/51 HCCs (90.2%) were identified as hyperechoic lesions during the early arterial or arterial phase with no correlation to histological differentiation. In the portal phase and late phase, the echogenicity of HCCs after contrast application was variable. A hypoechoic appearance was noted in 17/51 HCCs (33.3%) in the portal phase and in 21/51 HCCs (41.2%) in the late phase. Moderately differentiated HCCs were more often hypoechoic than well differentiated HCCs (p = 0.04). CONCLUSION: Contrast-enhanced sonography is highly efficient for the detection of tumour vascularity in HCCs. The majority of HCCs--regardless of histological differentiation--can be characterised as hypervascular lesions in the early arterial and arterial phase with irregular tumour vessels using contrast-enhanced sonography. In addition to B-scan sonomorphology, contrast-enhanced sonography may offer helpful information in patients with liver cirrhosis and focal liver lesions.

Carcinoma, Hepatocellular↗

Contrast enhanced sonography of focal splenic lesions with a second-generation contrast agent.

OBJECTIVE: Contrast enhanced sonography (CES) of second generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this study was to investigate the ability of a second generation contrast agent to enhance splenic lesions. METHODS: From October 2003 to September 2004, 46 consecutive patients with focal (peri-) splenic lesions on B-mode sonography were studied by CES using a transpulmonary second-generation contrast agent (SonoVue). Data were retrospectively evaluated. Diagnosis of the patients were infarction (n = 9), lymphoma (n = 7), metastasis (n = 6), injury (n = 4), haemangioma/splenoma (n = 6), accessory spleen (n = 3), cyst (n = 2), and unknown cause (n = 9). Diagnosed of splenic lesions was confirmed by histology (n = 5), contrast enhanced computed tomography (n = 25), MRI (n = 4), scintigraphy (n = 1), and follow up (n = 38). Extent of enhancement (EE) was evaluated during the arterial phase (5-30 s) and the parenchymal phase (3-5 minutes): EE of focal splenic lesions was determined using the surrounding splenic tissue as an in vivo reference, and classified as anechoic vs. hypoechoic vs. isoechoic vs. hyperechoic vs. mixed. The contribution of CES to the final diagnosis was classified as low, helpful or highly necessary. RESULTS: In all but one patient enhancement of normal splenic tissue occurred. During the arterial and parenchymal phase, lesions were found to have anechoic 10/10, hypoechoic 12/24, isoechoic 12/7, hyperechoic 7/0 and mixed enhancement 5/5, respectively. Value of CES for final diagnosis was low n = 24 (52%) (7 lymphomas, 6 metastases, 2 cysts, 9 unknown), helpful n = 9 (20%) (4 infarctions, 2 ruptures, 3 accessory spleens) and highly necessary n = 13 (28%) (5 infarctions, 2 ruptures, 6 haemangiomas/splenomas). CONCLUSION: Contrast-enhanced sonography is of diagnostic value in subgroups of patients with (peri-)splenic lesions (48%): including splenic infarction, splenic rupture, splenic haemangioma/splenoma, and accessory spleen.

Aged↗

[Vascularization patterns in focal liver lesions: comparison of plain and signal-enhanced amplitude-modulated color duplex ultrasonography].

PURPOSE: Morphology of focal liver lesions was studied by power Doppler. Plain images and images after i.v. application of galactose-based microbubbles (Levovist, Schering AG) were compared. METHODS: 21 patients with focal liver lesions were studied by power Doppler before and after application of the signal enhancer. RESULTS: In lesions that showed short pulsations in plain studies, vascular structures were visible after application of the signal enhancer. In hepatocellular carcinomas, multiple arteries with small diameter became visible. Peripheral veins were detected in metastases. A large feeding artery was detected in 1/2 haemangiomas with flow and in a focal nodular hyperplasia. CONCLUSION: In comparison to plain amplitude-modulated colour-coded duplex ultrasound, vascular patterns of focal liver lesions were more clearly visible after injection of a signal-enhancer.

Adult↗

[Color-coded duplex sonography and ultrasound contrast media--detection of renal perfusion defects in experimental animals].

The diagnostic use of microbubble consisting transpulmonary ultrasound contrast media in combination with color-coded duplex sonography (CCDS) has not been evaluated. Perfusion of the orthotopic kidney was therefore examined in an animal experiment with CCDS and transpulmonary echocontrast agent. The contrast agent consists of tiny stabilized air bubbles which survive the lung passage after peripheral venous injection and cause echo-enhancement of the arterial blood. The combination of CCDS and this contrast agent permits demonstration of the renal perfusion including the peripheral parenchyma. Even small experimental perfusion defects can be identified by this method. The use of this contrast agent in combination with CCDS might contribute significantly to the diagnostic potential of ultrasound.

Animals↗

[Echo morphology and puncture diagnosis of intraabdominal abscesses].

In this article it is reported about 35 intraabdominal abscesses, which were sonographically diagnosed in 32 patients. 22 times the diagnosis could be proven with percutaneous fine-needle-aspiration guided by ultrasound, five of them had a sonographically guided percutaneous abscess drainage, while 7 only could be diagnosed by operation. The sonomorphologic criteria of intraabdominal abscesses are polymorphous. Therefore we could subdivide the abscesses into five types according to their different echogeneity. Probes of pus, won by percutaneous five-needle-aspiration, were examined under experimental conditions in a waterbath. The sonomorphologic appearance is comparable to the in-situ-situation. Our experiments showed, that the echogeneity of intraabdominal abscesses is based on echogenic microbubbles besides echoforming detritus and protein-bodies. The polymorphous sonographic appearance of intraabdominal abscess formation and the well known problems of differential diagnosis gives percutaneous, sonographically guided fine-needle-aspiration an important position.

Abdomen↗

[Myocardial contrast echocardiography for the follow-up after percutaneous transluminal coronary angioplasty].

Myocardial contrast echocardiography was performed, before and after successful elective percutaneous transluminal angioplasty (PTCA) of a main coronary artery, in 35 patients (31 men, 4 women; mean age 56 +/- 6 years). After intracoronary injection of microbubbles-containing 2 ml iopromide, contrast half-life (t/2) and maximal echo-intensity (Imax) in the myocardial region supplied by the target vessel were measured. While t/2 decreased from 8.3 +/- 5.4 s to 5.7 +/- 3.3 s (P less than 0.0002), mean Imax remained unchanged (27.4 +/- 10.7 vs 26.1 +/- 10.1 grey value units). Repeat cardiac catheterization with contrast echocardiography was performed a mean of 37 weeks (7-53) later in 13 of 35 patients with optimal echo image quality. Re-stenosis of at least 75% was demonstrated in six patients, while in seven vessel diameter had decreased by less than 30%. In all patients with re-stenosis t/2 had increased by about 20 to 100% of the initial value. It was always over 5 s (mean 6.2 +/- 1.6 s before, 4.7 +/- 1.7 after PTCA, and 6.2 +/- 1.2 s at the end of the follow-up). In one patient a prolonged t/2 persisted due to vessel dissection. Mean t/2 remained unchanged in patients without re-stenosis (5.6 +/- 2.1 s before, 3.5 +/- 1.15 s immediately after PTCA, and 3.6 +/- 1.25 s at the follow-up examination). These data suggest that contrast half-life is suitable for demonstrating changes in myocardial perfusion after PTCA.

Angina Pectoris↗

Supercooling of aqueous NaCl and KCl solutions under acoustic levitation.

The supercooling capability of aqueous NaCl and KCl solutions is investigated at containerless state by using acoustic levitation method. The supercooling of water is obviously enhanced by the alkali metal ions and increases linearly with the augmentation of concentrations. Furthermore, the supercooling depends on the nature of ions and is 2-3 K larger for NaCl solution than that for KCl solution in the present concentration range: Molecular dynamics simulations are performed to reveal the intrinsic correlation between supercoolability and microstructure. The translational and orientational order parameters are applied to quantitatively demonstrate the effect of ionic concentration on the hydrogen-bond network and ice melting point. The disrupted hydrogen-bond structure determines essentially the concentration dependence of supercooling. On the other hand, the introduced acoustic pressure suppresses the increase of supercooling by promoting the growth and coalescence of microbubbles, the effective nucleation catalysts, in water. However, the dissolved ions can weaken this effect, and moreover the degree varies with the ion type. This results in the different supercoolability for NaCl and KCl solutions under the acoustic levitation conditions.

Cold Temperature↗

Power doppler harmonic imaging: a feasibility study of a new technique for the assessment of myocardial perfusion.

BACKGROUND: The aim of the study was to assess the feasibility of a new technique, power Doppler harmonic imaging (PDHI), for assessing myocardial perfusion through a venous injection of microbubbles, with the use of a new ultrasound contrast agent. METHODS AND RESULTS: Fifteen patients with known coronary artery disease and a resting perfusion abnormality on Tc-99m sestamibi single-photon emission computed tomography (SPECT) underwent PDHI at rest during intravenous injections of 2 to 3 mL of Sonovue (Bracco SpA, Milan, Italy), a new second-generation ultrasound contrast agent. Myocardial perfusion was determined to be present or absent by use of a 5-segment model by 2 blinded observers for both PDHI and SPECT. Of a total of 75 possible myocardial segments, 7 (9%) were not analyzed because of obvious artifacts on PDHI. SPECT showed perfusion defects in 40 of the remaining 68 segments, whereas PDHI showed 39 defects. There was high concordance between the 2 imaging modalities for the presence (93%) as well as the location (96% for the anteroseptal region, 93% for the inferoposterior region, and 87% for the apical region) of the defects. CONCLUSIONS: These preliminary results suggest that PDHI is a feasible technique for the detection of resting myocardial perfusion defects in patients with coronary artery disease after a venous injection of a new second-generation ultrasound contrast agent.

Adult↗

Quantification of mitral regurgitation in the cardiac catheterization laboratory with contrast echocardiography.

BACKGROUND: There is no method of quantifying the severity of mitral regurgitation (MR) from injection of tracer directly into the left ventricular (LV) cavity, a method commonly used in the cardiac catheterization laboratory. METHODS AND RESULTS: We used a previously validated mathematical model that derives regurgitant fraction (RF) from the relative tracer washout from the left atrial (LA) and LV cavities. Thirty-nine patients referred for diagnostic cardiac catheterization with clinical evidence of possible MR were included in the study. Five milliliters of a microbubble mixture was power-injected into the LV during simultaneously performed contrast echocardiography. Relative changes in background-subtracted video intensity were measured from the LV and LA, and the resultant model-derived RF was correlated with the severity of MR on cineangiography. The severity of MR ranged from 0 to 4+ on cineangiography with corresponding model-derived RF of 0 to 0.69 on contrast echocardiography. A close linear relation was noted between angiographic severity of MR and model-derived RF on contrast echocardiography (y = 0.1x + 0.03, r = 0.89, P <.001). Contrast echocardiography was more sensitive than cineangiography for detecting mild MR. CONCLUSIONS: We describe a new method of measuring the severity of MR in the cardiac catheterization laboratory. Apart from being quantitative, this method can be safely used during cardiac catheterization in patients in whom iodinated contrast agents may be potentially harmful.

Albumins↗

Accuracy and reproducibility of coronary flow rate assessment by real-time contrast echocardiography: in vitro and in vivo studies.

Real-time myocardial contrast echo (MCE) provides the potential to assess myocardial blood flow from time-intensity refilling curves after high-energy bubble destruction. This study validated the accuracy of this approach and the effect of specific examination variables and instrument settings on results. The effects of examination depth and angle as well as dynamic range, pulse repetition frequency, and line density were assessed with the use of in vitro incremental flow rates produced in an in vitro tissue phantom. In vivo recordings of real-time imaging with an infusion of a contrast agent (Optison) were obtained in 7 open-chest dogs with graded left anterior descending artery stenosis at baseline and during adenosine hyperemia, and were compared with flow probe measurements. After bubble destruction, time-intensity data were fitted to an exponential function, and the rate of intensity increase (b) and peak plateau intensity (A) were derived from refilling curves. In vivo real-time values for b, but not A, correlated closely with flow probe measures (r = 0.93). A similar correlation for b was observed in vitro (r = 0.98). The correlation between flow rate and b was influenced by several examination variables, including depth, angle, and instrument settings. Real-time MCE provides accurate quantification of coronary flow by assessing the rate of microbubble refilling. However, this parameter may be affected by several examination and instrument variables. Therefore, real-time MCE refilling measures are best applied by comparing baseline values with those of stress studies.

Animals↗

Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography.

Although regional myocardial perfusion can be currently quantified with myocardial contrast echocardiography (MCE) by using intermittent harmonic imaging (IHI), the method is tedious and time-consuming in the clinical setting. We hypothesized that regional myocardial perfusion can be quantified and the severity of coronary stenosis determined during hyperemia with MCE using real-time imaging (RTI) where microbubbles are not destroyed. Six open-chest dogs were studied during maximal hyperemia induced by adenosine in the absence or presence of coronary stenoses varying from mild to severe. Myocardial blood flow (MBF) was measured at each stage by using radiolabeled microspheres. MCE was performed using both IHI and RTI. Data for the latter were acquired in both end-systole and end-diastole. No differences were found between myocardial flow velocity (MFV) derived from IHI and RTI when end-systolic frames were used for the latter. MFV was consistently higher for RTI (P <.01) when end-diastolic frames were used. A linear relation was noted between MFV and radiolabeled microsphere-derived MBF ratios from the stenosed and the normal beds when end-systolic frames were used for RTI (r = 0.78, P <.001), whereas no relation was found when end-diastolic frames were used (r = 0.08, P =.78). The scatter for assessing MBF (A.beta) was minimal for IHI and RTI (9%-10%) with end-systolic frames, whereas that for RTI with end-diastolic frames was large (30%). Furthermore the correlation with radiolabeled microsphere-derived MBF was significantly (P <.01) weaker with RTI when end-diastolic frames were used (r = 0.53) than when end-systolic frames (r = 0.94) or IHI was used (r = 0.99). Data acquisition for IHI was 10 minutes, whereas it was 8 seconds for RTI. Thus, RTI can be used to quantify regional myocardial perfusion and stenosis severity during MCE. Only end-systolic frames, however, provide accurate data. RTI offers a rapid and easy means of assessing regional myocardial perfusion with MCE.

Animals↗

Rapid quantitative assessment of myocardial perfusion: spectral analysis of myocardial contrast echocardiographic images.

We described a novel rapid spectral analysis technique performed on raw digital in-phase quadrature (IQ) data that quantitatively differentiated perfused from nonperfused myocardium based on the simultaneous comparison of local fundamental and harmonic frequency band intensity levels. In open-chest pigs after ligation of the left anterior descending coronary artery (LAD) and continuous venous contrast infusion, the fundamental-to-harmonic intensity ratio (FHIR) for samples placed within the left ventricular (LV) cavity (10.8 +/- 1.7 dB) and perfused myocardium (13.7 +/- 1.6 dB) were significantly (P <.001) lower than for nonperfused myocardium (27.1 +/- 2.9 dB). In attenuated images, the FHIR for the LV cavity and perfused myocardium were also significantly (P <.05) lower than for the nonperfused myocardium (21.4 +/- 3.0 dB, 34.4 +/- 3.2 dB, and 40.2 +/- 4.4 dB, respectively). Spectral properties of contrast microbubbles, as characterized by the FHIR, allow for rapid quantitative assessment of myocardial perfusion from data contained in a single-image frame, without requiring background image subtraction and image averaging.

Acute Disease↗

Interobserver and intraobserver variability in detection of patent foramen ovale and atrial septal aneurysm with transesophageal echocardiography.

BACKGROUND: An accurate diagnosis of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) may be of decisional importance in the management of patients with ischemic stroke. Very few studies have been devoted to observer agreement in the diagnosis of these atrial septum abnormalities using contrast transesophageal echocardiography, which is considered as the method of choice for the diagnosis. The aim of this study was to assess interobserver and intraobserver variability in the diagnosis of PFO and ASA with contrast echocardiography. METHODS: Three sonographers independently reviewed 100 contrast studies stored on videotape on 2 occasions each. The interobserver and intraobserver variability was assessed by calculating kappa statistics. RESULTS: The overall interobserver and intraobserver kappa values for the assessment of degree of shunting through a PFO were 0.77 (first and second reading) and 0.82, respectively. The best kappa statistics were obtained when no and small shunts (less than 10 microbubbles) were pooled and compared with larger shunts. For the diagnosis of ASA, the overall interobserver kappa value was 0.45 for the first reading and 0.71 for the second reading, whereas the overall intraobserver kappa value was 0.74. CONCLUSION: Interobserver and intraobserver agreements for the diagnosis of PFO and ASA by transesophageal echocardiography are not perfect and need to be improved, particularly for ASA. This variability has to be taken into account when deciding on a potential risky treatment to prevent recurrent strokes.

Adult↗