Detection method for microchip separations.

The features of analytical systems utilizing microfluidic devices, especially detection methods, are described. Electrochemical detection (EC), laser-induced fluorescence (LIF), mass spectrometry (MS), and chemical luminescence (CL) methods are covered. EC enables detection without labeling and has been used in recent years because of its low cost and sensitivity. LIF is the most generally used detection method in microchip separations. Use of LED as an excitation source for fluorescence measurement was also developed for the purpose of miniaturization of the entire system, including detection and separation. Although MS enables highly sensitive analysis, the interface between MS and micro channels is still under examination. This review with fifty-two references introduces interesting detection methods for microchip separations. Related separation methods using microfluidic devices are also discussed.

Journal Article↗

A capillary electrophoresis chip with hydrodynamic sample injection for measurements from a continuous sample flow.

A microchip-based capillary electrophoresis device supported by a microfluidic network made of poly(dimethylsiloxane), used for measuring target analytes from a continuous sample flow, is presented. The microsystem was fabricated by means of replica molding in combination with standard microfabrication technologies, resulting in microfluidic components and an electrochemical detector. A new hydrodynamic sample injection procedure is introduced, and the maximum number of consecutive measurements that can be made with a poly(dimethylsiloxane) capillary electrophoresis chip with amperometric detection is investigated with respect to reproducibility. The device features a high degree of functional integration, so the benefits associated with miniaturized analysis systems apply to it.

Biosensing Techniques↗

Toward the detection of single virus particle in serum.

There is a grand challenge for the detection of target molecules at single molecule sensitivity in a bulk body fluid for the early diagnosis of diseases. We report our progress on tackling this challenge via the combination of fluorescence cross-correlation spectroscopy (FCCS) and micro fabricated devices toward highly sensitive detection of the dengue virus. We demonstrate that by using a dengue-specific antibody, we can probe the individual dengue virus in a nanomolar bulk solution by following the specific association of dengue antibody using FCCS. Consequently, we designed and fabricated a microfluidic chamber array structure and were able to compartmentalize the bulk aqueous dengue sample into femtoliter volumes using such a device. More importantly we demonstrate that we can differentiate between the compartments containing the dengue virus and the virus-free compartments. Our experiment suggests that by expanding the throughput using microfluidic devices integrated with FCCS, both of which can be achieved practically, we should be able to detect single virus particle in human body fluids in the near future.

Algorithms↗

Differential pH measurements of metabolic cellular activity in nl culture volumes using microfabricated iridium oxide electrodes.

In this paper we describe a new approach to measure pH differences in microfluidic devices and demonstrated acidification rate measurements in on-chip cell culture systems with nl wells. We use two miniaturized identical iridium oxide (IrOx) thin film electrodes (20 micromx400 microm), one as a quasi-reference electrode, the other as a sensing electrode, placed in two confluent compartments on chip. The IrOx electrodes were deposited onto microfabricated platinum (Pt) electrodes simultaneously using electrodeposition. Incorporating the electrodes into a microfluidic device allowed us to expose each electrode to a different solution with a pH difference of one pH unit maintaining a confluent connection between the electrodes. In this configuration, we obtained a reproducible voltage difference between the two IrOx thin film electrodes, which corresponds to the electrode sensitivities of -70 mV/pH at 22 degrees C. In order to measure the acidification rate of cells in nl cell culture volumes we placed one IrOx thin film electrode in the perfusion channel as a quasi-reference electrode and the other in the cell culture volume. We obtained an acidification rate of 0.19+/-0.02 pH/min for fibroblast cells using a stop flow protocol. These results show that we can use two identical miniaturized microfabricated IrOx electrodes to measure pH differences to monitor the metabolic activity of cell cultures on chip. Furthermore, our approach can also be applied in biosensor or bioanalytical applications.

Animals↗

Enzymatic microreactors in chemical analysis and kinetic studies.

The fields of application of microreactors are becoming wider every year. A considerable number of papers have been published recently reporting successful application of enzymatic microreactors in chemistry and biochemistry. Most are devices with enzymes immobilized on beads or walls of microfluidic channels, whilst some use dissolved enzymes to run a reaction in the microfluidic system. Apart from model systems, mostly with glucose oxidase, horseradish peroxidase and alkaline phosphatase, the principal fields of application of microreactors are tryptic digestion of proteins and polymerase chain reaction in automated analyses of proteomic and genetic material, respectively. Enzymatic microreactors also facilitate characterization of enzyme activity as a function of substrate concentration, and enable fast screening of new biocatalysts and their substrates. They may constitute key parts of lab-on-a-chip and muTAS, assisting the analysis of biomolecules. This review provides systematic coverage of examples of reports on enzymatic microreactors published recently, as well as relevant older papers.

Bioreactors↗

On-chip micellar electrokinetic chromatographic separation of phenolic chemicals in waters.

This paper describes on-chip micellar electrokinetic chromatography (MEKC) separation of bisphenol A and 3 kinds of alkylphenols, which have been recently recognized as endocrine disrupting chemicals for fish by the Japanese government, using microchip capillary electrophoresis with UV detection. We successfully obtained high-speed separation of the phenolic chemicals within 15 s as optimizing in microfluidic controls and MEKC separation conditions. We obtained fairly good linearity with correlation coefficient of over 0.98 from 0 to 50 mg/l phenolic chemicals except for 4-nonylphenol, which sample is the mixture of many geometrical isomers (r = 0.86). The values of the relative standard deviation for peak height in 50 mg/l phenolic chemicals were less than 8% except for bisphenol A (11.0%). The limits of detection obtained at a signal-to-noise ratio of 3 were from 5.6 to 20.0 mg/l. To realize on-site monitoring, we described strategy for on-chip MEKC analysis of the phenolic chemicals in waters using a portable analyzer based on microfluidic devices.

Chromatography, Micellar Electrokinetic Capillary↗

Functionality and stability of heparin immobilized onto poly(dimethylsiloxane).

Poly(dimethylsiloxane) (PDMS) has become an attractive material when working in the field of microfluidics, mainly because of the rapid prototyping process it involves. The increased surface volume ratio in microchannels makes the interaction between sample and material surface highly important, evident when handling complex biological samples such as plasma or blood. This study demonstrates a new grade of non-covalent heparin surface that adds efficient anticoagulant property to the PDMS material. The surface modification is a simple and fast one-step process performed at neutral pH, optimal when working with closed microsystems. The heparin formed a uniform and functional coating on hydrophobic PDMS with comparatively high level of antithrombin-binding capacity. In addition, long-term studies revealed that the immobilized heparin was more or less stable in the microchannels over a time of three weeks. Recalcified plasma in contact with native PDMS showed complete coagulation after 1h, while no fibrin formation was detected in plasma incubated on heparin-coated PDMS within the same time. In conclusion, we see the heparin coating developed and evaluated in this study as a tool that greatly facilitates the use of PDMS in microfluidics dealing with plasma or blood samples.

Antithrombins↗

An analysis of induced pressure fields in electroosmotic flows through microchannels.

Induced pressure gradients are found to cause band-broadening effects which are important to the performance of microfluidic devices, such as capillary electrophoresis and capillary chromatography. An improved understanding of the underlying mechanisms causing an induced pressure gradient in electroosmotic flows is presented. The analysis shows that the induced pressure distribution is the key to understanding the experimentally observed phenomena of leakage flows. A novel way of determining the static pressures at the inlet and outlet of microchannels is also presented that takes account of the pressure losses due to flow contraction and expansion. These commonly neglected pressure losses at the channel entrance and outlet are shown to be important in accurately describing the flow. The important parameters that define the effect of induced pressure on the flows are discussed, which may facilitate the design of improved microfluidic devices. The present model clearly identifies the mechanism behind the experimentally observed leakage flows, which is further confirmed by numerical simulations. Not only can the leakage flow occur from the electric-field-free side channel to the main channel, but also the fluid in the main channel can be attracted into the side channel by the induced pressure gradient.

Journal Article↗

Interface motion of capillary-driven flow in rectangular microchannel.

In microchannel flow, gas-liquid interface behavior is important for developing a wide range of microfluidic applications, especially in passive microfluidic systems. This paper presents a discussion of interface motion driven by capillary action in a microchannel. We have extended the theory beyond the previous theory of capillary rise problem for a circular tube, to a rectangular microchannel. The same formula for the relation between nondimensional time and interface position is obtained as for a circular tube. We examined rectangular microchannels with several sizes (about 50 to 100 microm square) of glass capillaries and 85 x 68 microm and 75 x 45 microm polydimethylsiloxane (PDMS) microchannels fabricated by photolithography technique, respectively. We observed movement of the gas-liquid interface position and compared it to the dimensionless relation. We obtained the value of a dimensionless variable of driving force that is related to dynamic contact angles for glass-water, glass-ethanol, and PDMS-ethanol. Using this variable, interface motion can be predicted for any size of rectangular channels.

Journal Article↗

Electroosmotic flow in microchannels with arbitrary geometry and arbitrary distribution of wall charge.

General solutions are developed for direct current (DC) and alternating current (AC) electroosmotic flows in microfluidic channels with arbitrary cross-sectional geometry and arbitrary distribution of wall charge (zeta potential). The applied AC electric field can also be of arbitrary waveform. By proposing a nondimensional time scale varpi defined as the ratio of the diffusion time of momentum across the electric double-layer thickness to the period of the applied electric field, we demonstrate analytically that the Helmholtz-Smoluchowski electroosmotic velocity is an appropriate slip condition for AC electroosmotic flows in typical microfluidic applications. With this slip condition approach, electroosmotic flows in rectangular and asymmetric trapezoidal microchannels with nonuniform wall charge, as examples, are investigated. The unknown constants in the proposed general solutions are numerically determined with a least-squares method through matching the boundary conditions. We find that the wall charge affects significantly the electroosmotic flow while the channel geometry does not. Moreover, the flow feature is characterized by another nondimensional time scale Omega defined as the ratio of the diffusion time of momentum across the channel hydraulic radius to the period of the applied electric field. The onset of phase shift between AC electroosmotic velocity and applied electric field is also examined analytically.

Journal Article↗

Trapping of microparticles in the near field of an ultrasonic transducer.

We are investigating means of handling microparticles in microfluidic systems, in particular localized acoustic trapping of microparticles in a flow-through device. Standing ultrasonic waves were generated across a microfluidic channel by ultrasonic microtransducers integrated in one of the channel walls. Particles in a fluid passing a transducer were drawn to pressure minima in the acoustic field, thereby being trapped and confined at the lateral position of the transducer. The spatial distribution of trapped particles was evaluated and compared with calculated acoustic intensity distributions. The particle trapping was found to be strongly affected by near field pressure variations due to diffraction effects associated with the finite sized transducer element. Since laterally confining radiation forces are proportional to gradients in the acoustic energy density, these near field pressure variations may be used to get strong trapping forces, thus increasing the lateral trapping efficiency of the device. In the experiments, particles were successfully trapped in linear fluid flow rates up to 1mm/s. It is anticipated that acoustic trapping using integrated transducers can be exploited in miniaturised total chemical analysis systems (microTAS), where e.g. microbeads with immobilised antibodies can be trapped in arrays and subjected to minute amounts of sample followed by a reaction, detected using fluorescence.

Journal Article↗

Modeling of DNA hybridization kinetics for spatially resolved biochips.

The marriage of microfluidics with detection technologies that rely on highly selective nucleic acid hybridization will provide improvements in bioanalytical methods for purposes such as detection of pathogens or mutations and drug screening. The capability to deliver samples in a controlled manner across a two-dimensional hybridization detection platform represents a substantial technical challenge in the development of quantitative and reusable biochips. General theoretical and numerical models of heterogeneous hybridization kinetics are required in order to design and optimize such biochips and to develop a quantitative method for online interpretation of experimental results. In this work we propose a general kinetic model of heterogeneous hybridization and develop a technique for estimating the kinetic coefficients for the case of well-spaced, noninteracting surface-bound probes. The experimentally verified model is then incorporated into the BLOCS (biolab-on-a-chip simulation) 3D microfluidics finite element code and used to model the dynamic hybridization on a biochip surface in the presence of a temperature gradient. These simulations demonstrate how such a device can be used to discriminate between fully complementary and single-base-pair mismatched hybridization using fluorescence detection by interpretation of the unique spatially resolved intensity pattern. It is also shown how the dynamic transport of the targets is likely to affect the rate and location of hybridization as well as that, although nonspecific hybridization is present, the change in the concentration of hybridized targets over the sensor platform is sufficiently high to determine if a fully complementary match is present. Practical design information such as the optimum transport speed, target concentration, and channel height is presented. The results presented here will aid in the interpretation of results obtained with such a temperature-gradient biochip.

Biosensing Techniques↗

Sample stacking in laboratory-on-a-chip devices.

Sample stacking is a very important sample concentration technique. It has been used widely in capillary electrophoresis (CE). There are many different stacking techniques. One of the most popular techniques is called "field-amplified sample stacking" where an electric field discontinuity is set up across a concentration boundary. Charged analytes will then automatically stacked due to velocity changes after they cross the concentration boundary. There are several different strategies to perform sample stacking in microfluidic laboratory-on-a-chip devices. One could simply inject a plug of low concentration buffer containing sample into a channel surrounded by high concentration buffer. The electric field is then applied to stack the sample and move the whole plug into the separation channel. One could also stack the sample in a side channel adjacent to the separation channel. The disadvantage of this sample stacking technique is the difficulty in control of the precise location of stacked sample. We present a new sample stacking technique applied specifically to microfluidic laboratory-on-a-chip devices. Up to hundreds of fold increases in sample concentration can be achieved. We have also combined this stacking with electrophoretic separation in the same device.

Electrophoresis, Capillary↗

Microfabrication of polydimethylsiloxane electrospray ionization emitters.

Microfabricated polydimethylsiloxane (PDMS) emitters for electrospray ionization mass spectrometry (ESI-MS) were implemented as tips along the edge of the PDMS device by three methods which utilize soft lithography processes. These microfabrication methods for producing PDMS emitters as an integral part of a microfluidic device will facilitate development of more complex microfluidic analysis systems using ESI-MS.

Dimethylpolysiloxanes↗

Fabrication of calcium fluoride capillary electrophoresis microdevices for on-chip infrared detection.

In this paper, we demonstrate microfluidic capillary electrophoresis (CE) devices made in CaF2 , for optical detection in a broad spectral range. We have designed methods for micromachining and enclosing capillaries in CaF2. The utility of these microdevices has been shown through CE analysis of fluorescently labeled amino acids. We have also performed infrared spectroscopy for analyte identification in microfluidic CaF2 channels. These CaF2 microdevices open the door to microchip separations with optical detection in the ultraviolet, visible, and infrared spectral regions.

Calcium Fluoride↗

Micromechanical studies of mitotic chromosomes.

We review micromechanical experiments studying mechanoelastic properties of mitotic chromosomes. We discuss the history of this field, starting from the classic in vivo experiments of Nicklas (1983). We then focus on experiments where chromosomes were extracted from prometaphase cells and then studied by micromanipulation and microfluidic biochemical techniques. These experiments reveal that chromosomes have a well-behaved elastic response over a fivefold range of stretching, with an elastic modulus similar to that of a loosely tethered polymer network. Perturbation by microfluidic "spraying" of various ions reveals that the mitotic chromosome can be rapidly and reversibly decondensed or overcondensed, i.e., that the native state is not maximally compacted. We compare our results for chromosomes from cells to results of experiments by Houchmandzadeh and Dimitrov (1999) on chromatids reconstituted using Xenopus egg extracts. Remarkably, while the stretching elastic response of reconstituted chromosomes is similar to that observed for chromosomes from cells, reconstituted chromosomes are far more easily bent. This result suggests that reconstituted chromatids have a large-scale structure that is quite different from chromosomes in somatic cells. Finally, we discuss microspraying experiments of DNA-cutting enzymes, which reveal that the element that gives mitotic chromosomes their mechanical integrity is DNA itself. These experiments indicate that chromatin-condensing proteins are not organized into a mechanically contiguous "scaffold," but instead that the mitotic chromosome is best thought of as a cross-linked network of chromatin. Preliminary results from restriction enzyme digestion experiments indicate a spacing between chromatin "cross-links" of roughly 15 kb, a size similar to that inferred from classical chromatin loop isolation studies. These results suggest a general strategy for the use of micromanipulation methods for the study of chromosome structure.

Animals↗

Factors involved in the production of liposomes with a high-pressure homogenizer.

A variety of factors were evaluated in order to establish the characteristics of the liposomes obtained with a high-pressure homogenizer (Microfluidizer 110S). The experimental mean diameter of the liposomes and the width of their size distribution were correlated to surfaces calculated from the responses obtained by the combination of two groups of factors. First, the inlet pressure of the homogenizer, the times that the samples were processed (cycles) and the bulk ionic strength. Second, the phospholipid (P) and ethanol concentrations. The variation of the entrapped liposome volume upon the pressure and cycles was also studied. All the calculated surfaces are statistically significant and have a low S.E. of estimate. Mean liposome diameter decreases with increasing inlet pressure, number of cycles and ethanol concentration, and increases raising ionic strength. No P concentration effect was observed. The variation of the entrapped volume of liposomes upon the cycles and pressure has a similar behavior to the diameter. Within the studied variable range, microfluidization does not increase the P oxidation index, nor does it significantly alter the P concentration.

Drug Compounding↗

Effect of adsorption of bovine serum albumin on liposomal membrane characteristics.

The effect of adsorption of bovine serum albumin (BSA) on the membrane characteristics of liposomes at pH 7.4 was examined in terms of zeta potential, micropolarity, microfluidity and permeability of liposomal bilayer membranes, where negatively charged L-alpha-dipalmitoylphosphatidylglycerol (DPPG)/L-alpha-dipalmitoylphosphatidylcholine (DPPC), negatively charged dicetylphosphate (DCP)/DPPC and positively charged stearylamine (SA)/DPPC mixed liposomes were used. BSA with negative charges adsorbed on negatively charged DPPG/DPPC mixed liposomes but did not adsorb on negatively charged DCP/DPPC and positively charged SA/DPPC mixed liposomes. Furthermore, the adsorption amount of BSA on the mixed DPPG/DPPC liposomes increased with increasing the mole fraction of DPPG in spite of a possible electrostatic repulsion between BSA and DPPG. Thus, the adsorption of BSA on liposomes was likely to be related to the hydrophobic interaction between BSA and liposomes. The microfluidity of liposomal bilayer membranes near the bilayer center decreased by the adsorption of BSA, while the permeability of liposomal bilayer membranes increased by the adsorption of BSA on liposomes. These results are considered to be due to that the adsorption of BSA brings about a phase separation in liposomes and that a temporary gap is consequently formed in the liposomal bilayer membranes, thereby the permeability of liposomal bilayer membranes increases by the adsorption of BSA.

Journal Article↗