PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

Biomimetic approaches to tendon repair.

The linear organization of collagen fibers in tendons results in optimal stiffness and strength at low strains under tensile load. However, this organization makes repairing ruptured or lacerated tendons extremely difficult. Current suturing techniques to join split ends of tendons, while providing sufficient mechanical strength to prevent gapping, are inadequate to carry normal loads. Immobilization protocols necessary to restore tendon congruity result in scar formation at the repair site and peripheral adhesions that limit excursion. These problems are reviewed to emphasize the need for novel approaches to tendon repair, one of which is the development of biomimetic tendons. The objective of the empirical work described here was to produce biologically-based, biocompatible tendon replacements with appropriate mechanical properties to enable immediate mobilization following surgical repair. Nor-dihydroguaiaretic acid (NDGA), a di-catechol from creosote bush, caused a dose dependent increase in the material properties of reconstituted collagen fibers, achieving a 100-fold increase in strength and stiffness over untreated fibers. The maximum tensile strength of the optimized NDGA treated fibers averaged 90 MPa; the elastic modulus of these fibers averaged 580 MPa. These properties were independent of strain rates ranging from 0.60 to 600 mm/min. Fatigue tests established that neither strength nor stiffness were affected after 80 k cycles at 5% strain. Treated fibers were not cytotoxic to tendon fibroblasts. Fibroblasts attached and proliferated on NDGA treated collagen normally. NDGA-fibers did not elicit a foreign body response nor did they stimulate an immune reaction during six weeks in vivo. The fibers survived 6 weeks with little evidence of fragmentation or degradation. The polymerization scheme described here produces a fiber-reinforced NDGA-polymer with mechanical properties approaching an elastic solid. The strength, stiffness and fatigue properties of the NDGA-treated fibers are comparable to those of tendon. These fibers are biocompatible with tendon fibroblasts and elicit little rejection or antigenic response in vivo. These results indicate that NDGA polymerization may provide a viable approach for producing collagenous materials that can be used to bridge gaps in ruptured or lacerated tendons. The tendon-like properties of the NDGA-fiber would allow early mobilization after surgical repair. We predict that timely loading of parted tendons joined by this novel biomaterial will enhance mechanically driven production of neo-tendon by the colonizing fibroblasts and result in superior repair and rapid return to normal properties.

Animals↗

Viscoelasticity in wild-type and vinculin-deficient (5.51) mouse F9 embryonic carcinoma cells examined by atomic force microscopy and rheology.

We have been studying mouse F9 embryonic carcinoma cells which contain no detectable vinculin protein (5.51 cells), and compared them with F9 wild-type cells. Employing atomic force microscopy, we probed the elastic properties of individual F9 wild-type and 5.51 cells by measuring the dynamic response of controlled loads of the cantilever tip. An elastic modulus (Young) of approximately 3.8 and approximately 2.5 kPa was calculated for wild-type and 5.51 cells, respectively. Using disc rheometry, we detected a marked change in shear of a 1000g pellet of approximately 55 x 10(6) cells between wild-type and 5.51 mutants. These differences are attributed to the loss of vinculin and altered cytoskeletal organization in these cells.

Animals↗

Estimates of biomechanical forces in Magnaporthe grisea.

The mechanical actions of the fungus Magnaporthe grisea raise many intriguing questions concerning the forces involved. These include: (1) the material properties of the appressorial wall; (2) the strength of the adhesive that keeps the appressorium anchored to the rice leaf surface; and (3) the forces involved in the penetration process whereby a peg is driven through the host cell wall. In this paper we give order of magnitude estimates for all three of these quantities. A simple Young-Laplace law type argument is used to show that the appressorial wall elastic modulus is of order 10-100 MPa; and an adaptation of standard adhesion theory indicates a lower bound on the strength of the appressorial adhesive to be of the order 500 J/m(2). Drawing on ideas from plasticity theory and ballistics, estimates of the penetration force raise interesting questions about experiments performed on the penetration of inert substrates by the fungus.

Biomechanical Phenomena↗

Contact mechanics analysis of metal-on-metal hip resurfacing prostheses.

Finite-element method was employed to study the contact mechanics in metal-on-metal hip resurfacing prostheses, with particular reference to the effects of bone quality, the fixation condition between the acetabular cup and bone, and the clearance between the femoral head and the acetabular cup. Simple finite-element bone models were developed to simulate the contact between the articulating surfaces of the femoral head and the acetabular cup. The stresses within the bone structure were also studied. It was shown that a decrease in the clearance between the acetabular cup and femoral head had the largest effect on reducing the predicted contact-pressure distribution among all the factors considered in this study. It was found that as the clearance was reduced, the influence of the underlying materials, such as bone and cement, became increasingly important. Stress shielding was determined to occur in the bone tissue surrounding the hip resurfacing prosthesis considered in this study. However, the stress-shielding effects predicted were less than those observed in conventional total hip replacements. Both the effects of bone quality (reduction in elastic modulus) and the fixation condition between the cup and the bone were found to have a negligible effect on the predicted contact mechanics at the bearing surface. The loading was found to have a relatively small effect on the predicted maximum contact pressure at the bearing surface; this was attributed to an increase in contact area as the load was increased.

Computer Simulation↗

Structure and properties of clinical coralline implants measured via 3D imaging and analysis.

The development and design of advanced porous materials for biomedical applications requires a thorough understanding of how material structure impacts on mechanical and transport properties. This paper illustrates a 3D imaging and analysis study of two clinically proven coral bone graft samples (Porites and Goniopora). Images are obtained from X-ray micro-computed tomography (micro-CT) at a resolution of 16.8 microm. A visual comparison of the two images shows very different structure; Porites has a homogeneous structure and consistent pore size while Goniopora has a bimodal pore size and a strongly disordered structure. A number of 3D structural characteristics are measured directly on the images including pore volume-to-surface-area, pore and solid size distributions, chord length measurements and tortuosity. Computational results made directly on the digitized tomographic images are presented for the permeability, diffusivity and elastic modulus of the coral samples. The results allow one to quantify differences between the two samples. 3D digital analysis can provide a more thorough assessment of biomaterial structure including the pore wall thickness, local flow, mechanical properties and diffusion pathways. We discuss the implications of these results to the development of optimal scaffold design for tissue ingrowth.

Animals↗

Oxidative stress and the mechanical properties of naturally occurring chimeric collagen-containing fibers.

The byssal threads of marine mussels are a fiber-reinforced composite material. Fibers are continuous, separated by matrix, and consist of chimeric collagens that encompass within the same primary protein structure domains corresponding to collagen, polyhistidine, and either elastin or dragline spider silk. The elastic modulus (stiffness) of the proximal portion of byssal threads was measured by cyclic stress-strain analysis at 50% extension. Before measurement, the threads were conditioned by various treatments, particularly agitation in aerated or nitrogen-sparged seawater. Stiffness can be permanently increased by more than two times, e.g., from 25 MPa to a maximum of 65 MPa, by simple agitation in aerated seawater. Much but not all of this stiffening can be prevented by agitation under nitrogen. Reversible strain stiffening would seem to be a useful adaptation to lower residual stresses arising from the deformation of two joined materials, i.e., distal and proximal portions with rather different elastic moduli. The permanent strain stiffening that characterizes proximal byssal threads subjected to oxidative stress is probably due to protein cross-linking. In the short term, this results in a stronger thread but at the expense of dynamic interactions between the molecules in the structure.

Animals↗

An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements.

Contact mechanics of ultra high molecular weight polyethylene (UHMWPE) cups against metallic femoral heads for artificial hip joints is considered in this study. Both the experimental measurement of the contact area and the finite element prediction of the contact radius, maximum contact pressure and maximum Von Mises stress have been carried out for a wide range of contemporary artificial hip joints. Good agreement of the contact radius has been found between the experimental measurements and the finite element predictions based upon an elastic modulus of 1000 MPa and a Poisson's ratio of 0.4 for UHMWPE material under various loads up to 2.5 kN. It has been shown that the half contact angle for all the cup/head combinations considered in this study is between 40 degrees and 50 degrees under a load of 2.5 kN. The importance of this result has been discussed with respect to the anatomical position of the cup when placed in the body and the selection of a simple wear-screening test for artificial hip joints. The predicted contact radius and maximum contact pressure from the finite element model have also been compared with a simple elasticity analysis. It has been shown that the difference in the predicted contact radius between the two methods is reduced for more conforming contacts between the femoral head and the acetabular cup and smaller UHMWPE cup thickness. However, good agreement of the predicted maximum contact pressure has been found for all the combinations of the femoral head and the acetabular cup considered in this study. The importance of contact mechanics on the clinical performance of artificial hip joint replacements has also been discussed.

Elasticity↗

Viscoelastic and thermal properties of collagen/poly(vinyl alcohol) blends.

Blends of poly(vinyl alcohol) (PVA) with collagen and gelatin, prepared from aqueous solution by solvent casting, were investigated by differential scanning calorimetry (DSC) and dynamic mechanical thermal analysis (DMTA). After conditioning at 51% relative humidity, collagen and PVA show nearly coincident glass transition temperatures (Tg approximately 35 degrees C), while gelatin has a higher Tg (approximately 70 degrees C). Gelatin/PVA blends show two invariant Tgs, whose temperature and associated specific heat increment clearly indicate the coexistence of two amorphous phases composed of the pure components. Owing to similarity of the Tgs of collagen and PVA after humidity conditioning, DSC offers no indication on miscibility of collagen/PVA blends. In DMTA experiments, where absorbed water freely evaporates from the samples during the thermal scan, PVA shows a glass transition relaxation at about 50 degrees C, while both gelatin and collagen display an intense glass transition in the vicinity of 230 degrees C. The DMTA spectra of collagen/PVA and gelatin/PVA blends show two invariant glass transition relaxations at about 50 and 230 degrees C. Absence of any Tg shift with composition demonstrates that the blend components are immiscible. However, blends of PVA with collagen and gelatin form optically clear films with good mechanical properties over the whole range of compositions. It is found that at T > Tg (PVA) the elastic modulus (E') of the blends strongly increases with increasing content of the biopolymer. In the case of collagen/PVA blends, experimental E' values agree with the predictions of a simple two-phase composite model with phases connected in parallel. It is concluded that, though thermodynamically immiscible with both native and denatured collagen, PVA forms mechanically compatible blends with collagen and gelatin.

Animals↗

Frequency response of a viscoelastic tensegrity model: Structural rearrangement contribution to cell dynamics.

In an attempt to understand the role of structural rearrangement onto the cell response during imposed cyclic stresses, we simulated numerically the frequency-dependent behavior of a viscoelastic tensegrity structure (VTS model) made of 24 elastic cables and 6 rigid bars. The VTS computational model was based on the nonsmooth contact dynamics (NSCD) method in which the constitutive elements of the tensegrity structure are considered as a set of material points that mutually interact. Low amplitude oscillatory loading conditions were applied and the frequency response of the overall structure was studied in terms of frequency dependence of mechanical properties. The latter were normalized by the homogeneous properties of constitutive elements in order to capture the essential feature of spatial rearrangement. The results reveal a specific frequency-dependent contribution of elastic and viscous effects which is responsible for significant changes in the VTS model dynamical properties. The mechanism behind is related to the variable contribution of spatial rearrangement of VTS elements which is decreased from low to high frequency as dominant effects are transferred from mainly elastic to mainly viscous. More precisely, the elasticity modulus increases with frequency while the viscosity modulus decreases, each evolution corresponding to a specific power-law dependency. The satisfactorily agreement found between present numerical results and the literature data issued from in vitro cell experiments suggests that the frequency-dependent mechanism of spatial rearrangement presently described could play a significant and predictable role during oscillatory cell dynamics.

Animals↗

The load-displacement characteristics of neonatal rat cranial sutures.

OBJECTIVE: Recently several centers have attempted to distract the craniofacial skeleton in infants with craniosynostosis. To effectively achieve this goal, we must first understand the normal sutural response to tensile forces. The objective of this study was to determine the load-displacement characteristics of neonatal rat sutures. METHODS: Thirty cranial sutures were harvested from 1-week-old Wistar rats (10 each coronal, posterior frontal, and sagittal). The width of the harvested bone-suture-bone construct was standardized to 4 mm. The specimens, kept moist, were mounted fresh and distracted at 10 microm/sec until rupture using a Vitrodyne V1000 universal tester. Standard load-displacement curves were constructed. The stiffness, defined as tensile force/change in suture length, and the ultimate stress, defined as tensile force at suture rupture/cross sectional area, were calculated. RESULTS: These sutures demonstrated classical viscoelastic behavior. During the elastic phase, they elongated approximately 1 microm for every 1 g of force (10(4) N/m). The ultimate tensile stress was approximately 4 MN/m2. The estimated mean elastic modulus was 10 megapascals. The posterior frontal sutures were significantly less stiff than the other two sutures (Kruskal-Wallis nonparametric analysis of variance, p = .0023). The difference in the ultimate stress was also significant (p = .0201). CONCLUSIONS: This study provides data regarding the basic mechanical behavior of neonatal cranial sutures in a mammalian system.

Analysis of Variance↗

Holographic interferometry of intact and radially incised human eye-bank corneas.

Many methods to measure corneal elasticity destroy the tissue and thereby produce erroneous results. Holographic interferometry, a highly precise nondestructive optical comparison technique, was used to evaluate corneal elasticity of intact eye-bank eyes. A double-pulse holographic interferometer operating at 632.8 nm was used to measure corneal deformation in 20 whole-globe eyes from donors 45 to 83 years of age for intraocular pressures from 16 mm Hg to 21 mm Hg. Stress was computed from LaPlace's law, and arc length strain was derived from z-axis distention of the central cornea. The stress-strain relationship in the normal physiological range of intraocular pressure was linear with a Young's elastic modulus of 1.03 gigapascals for the central cornea (r = 0.999). During interferometry of radial keratotomy of the cornea, interference fringe patterns developed in association with each incision as it was made. When four incisions were placed deep along each of the primary semimeridians, the fringe pattern developed as expected, based on current keratotomy models. When incisions were shallow (approximately 50% depth) and placed asymmetrically along the nasal, temporal, and superior semimeridians, the resulting surface strain was symmetrical about the central cornea, forming an annular pattern of interference fringes. These results indicate that when the cornea was stressed at physiological pressures as part of the intact whole globe, it was less elastic than excised corneal tissue tested by strip extensiometry. Radially incised corneas demonstrated strain patterns suggestive of inherent structural anisotropy with a possible inferior quadrant weakness.

Adult↗

Imaging articular cartilage under compression--cartilage elastography.

We constructed a device to compress small samples of articular cartilage while the samples were imaged in a 1.5 T imager. With the use of a piezoelectric piston, the device compressed 1-cm-diameter cylindrical samples of articular cartilage (200 microm) at a rate of 2 Hz. Simultaneously, we imaged the samples with a displacement-sensitive stimulated-echo acquisition mode (STEAM) sequence. We validated the technique using tissue that mimicked silicone samples. We compared the results from the same cartilage samples before and after they were degraded by digestion in trypsin. The extent of degradation was visualized from T(1)-weighted images of the samples after they were soaked in 0.5 mmolar of GdDTPA. The resulting elastographic images show compression and differential strain in directions both parallel and perpendicular to the surface of the cartilage. The static elastographic images that depict compression made before digestion and after 5 and 15 hr of trypsin digestion show that the elastic modulus of the samples decreased with a spatial variation consistent with the enzymatic digestion as revealed by the T(1) images. We believe this technique will be useful in studies of the mechanical properties of articular cartilage and other tissues, and may in the future be extended to the clinical setting.

Animals↗

Electronmicroscopic investigation of the flexibility of F-actin.

The contour lenghts and the end-to-end distances of a large number of F-actin filaments were measured in electronmicrographs. Preparation of F-actin for electron-microscopy was made at three different temperatures. The flexibility parameter or the elastic modulus for bending of F-actin was determined from the relation between the contour length and the end-to-end distance after statistical treatment. The value of the flexibility parameter obtained here showed good agreement with that obtained by the quasielastic light scattering at all temperatures examined. The flexibility of F-actin increased with raising temperature and with the binding of heavy meromyosin.

Actins↗

Effects of longitudinal stretch on VSM tone and distensibility of muscular conduit arteries.

With progressing age, large arteries diminish their longitudinal stretch, which in extreme cases results in tortuosity. Increased age is also associated with loss of vessel distensibility. We measured pressure-diameter curves from muscular porcine carotid arteries ex vivo at different longitudinal stretch ratios (lambda(z) = 1.4 and 1.8) and under different vascular smooth muscle (VSM) conditions (fully relaxed, normal VSM tone, and maximally contracted). Distensibility was found to be halved by decreasing longitudinal stretch from lambda(z) = 1.8 to 1.4 at physiological pressures. This counterintuitive observation is possible because highly nonlinear elastic modulus of the artery and anisotropic properties. Furthermore, a significantly larger basal VSM contraction was observed at lambda(z) = 1.8 than 1.4, although this was clearly not related to a myogenic response during inflation. This dependence of VSM tone to longitudinal stretch may have possible implications on the functional characteristics of the arterial wall.

Animals↗

Mechanical properties of carbon nanotubes and their polymer nanocomposites.

More than 10 years have passed since carbon nanotubes (CNT) have been found during observations by transmission electron microscopy (TEM). Since then, one of the major applications of the CNT is the reinforcements of plastics in processing composite materials, because it was found by experiments that CNT possessed splendid mechanical properties. Various experimental methods are conducted in order to understand the mechanical properties of varieties of CNT and CNT-based composite materials. The systematized data of the past research results of CNT and their nanocomposites are extremely useful to improve processing and design criteria for new nanocomposites in further studies. Before the CNT observations, vapor grown carbon fibers (VGCF) were already utilized for composite applications, although there have been only few experimental data about the mechanical properties of VGCF. The structure of VGCF is similar to that of multi-wall carbon nanotubes (MWCNT), and the major benefit of VGCF is less commercial price. Therefore, this review article overviews the experimental results regarding the various mechanical properties of CNT, VGCF, and their polymer nanocomposites. The experimental methods and results to measure the elastic modulus and strength of CNT and VGCF are first discussed in this article. Secondly, the different surface chemical modifications for CNT and VGCF are reviewed, because the surface chemical modifications play an important role for polymer nanocomposite processing and properties. Thirdly, fracture and fatigue properties of CNT/polymer nanocomposites are reviewed, since these properties are important, especially when these new nanocomposite materials are applied for structural applications.

Crystallization↗

Aminoguanidine and aortic wall mechanics, structure, and composition in aged rats.

With aging, the aortic wall becomes stiffer. This could be because of changes in wall stress or composition. We investigated whether a specific change in wall composition, ie, accumulation of advanced glycation end products (AGEs) on the extracellular matrix, is a major factor. We measured aortic mechanics, geometry, and composition in 3-, 10-, 15-, 20-, and 30-month-old inbred normotensive Wistar-Glaxo/Rijswick rats and in a group of 30-month-old rats treated from 20 months onward with aminoguanidine (AG, 42 mg/kg per day), an inhibitor of AGE formation. Thoracoabdominal aortic (pressure) pulse-wave velocity (PWV) increased progressively with age (44% from 3 to 30 months). This age-related increase in aortic PWV was not related to changes in wall stress. For all ages, central (and peripheral) aortic mean blood pressures were not statistically different. Dilatation occurred (18% increase in internal diameter from 3 to 30 months), but this was accompanied by outward hypertrophic remodeling, with an increase in the medial cross-sectional area of 95% and in the ratio of medial thickness to internal diameter of 29%. Wall stress decreased with age (-34%). There was an increase in the ratio of elastic modulus (calculated from the Moens-Korteweg equation) to wall stress (calculated from the Lamé equation, 117% from 3 to 30 months), suggesting that a change in the composition of the wall is responsible for the age-linked increase in wall stiffness. Dry weight decreased slightly but significantly (-14%) with age. Total protein, elastin, collagen, and nonscleroprotein protein [total-(elastin+collagen)] contents did not change with age, but calculated densities of all 4 were halved (as the medial cross-sectional area doubled). The elastin/collagen ratio was statistically similar at all ages. The only significant effect of AG treatment was a fall in PWV (-20%), leading to a fall in the elastic modulus/wall stress ratio (-27% at 10 months of AG treatment versus 30 months of no treatment). In conclusion, the age-related increase in aortic wall stiffness is prevented by 10 months of treatment with AG, which has no effect on wall stress or composition, suggesting that AG may improve aortic wall stiffness by lowering the degree of AGE-induced cross-linking of the extracellular matrix scleroproteins, such as collagen.

Aging↗

Nucleotide-dependent single- to double-headed binding of kinesin.

The motility of kinesin motors is explained by a "hand-over-hand" model in which two heads of kinesin alternately repeat single-headed and double-headed binding with a microtubule. To investigate the binding mode of kinesin at the key nucleotide states during adenosine 5'-triphosphate (ATP) hydrolysis, we measured the mechanical properties of a single kinesin-microtubule complex by applying an external load with optical tweezers. Both the unbinding force and the elastic modulus in solutions containing AMP-PNP (an ATP analog) were twice the value of those in nucleotide-free solution or in the presence of both AMP-PNP and adenosine 5'-diphosphate. Thus, kinesin binds through two heads in the former and one head in the latter two states, which supports a major prediction of the hand-over-hand model.

Adenosine Diphosphate↗

Effect of freezing on lens capsule mechanical behavior.

Postmortem storage of lens capsules by freezing was found to increase capsular thickness slightly (5%). The effect on mechanical properties was minor. Ultimate tensile strength and ultimate stiffness were not changed by freezing. Ultimate strain was slightly increased (2%) and the elastic modulus calculated at 40% strain was decreased (20%). Frozen capsules were found to relax to a slightly lower value than fresh ones (2%). The results show that freezing tends to soften the tissue, possibly due to an increased hydration. In spite of this effect, which has to be kept in mind, postmortem freezing seems to be an acceptable storage method when collecting tissue for biomechanical research.

Animals↗