Microfabricated PDMS multichannel emitter for electrospray ionization mass spectrometry.

A novel microfabricated multichannel emitter for electrospray ionization mass spectrometry (ESI-MS) was implemented with polydimethylsiloxane (PDMS) using a soft lithography technique. The emitters are formed as electrospray tips along a thin membrane on the edge of the device with channels of 100 microm x 30 microm dimensions. The electrospray performance of the PDMS emitters for a single channel device and a four channel device interfaced with a time-of-flight mass spectrometer was evaluated for detecting the molecular weight of reference peptides (angiotensin I and bradykinin). The emitters were durable at the flow rate of 1-20 microL min(-1) for more than 30 h of continuous electrospray with limit of detection of 1 microM (S/N 18). This microfabrication method for a PDMS multichannel emitter as an integral part of a microfluidic device will facilitate development of more complex microfluidic analysis systems using ESI-MS.

Journal Article↗

Fluorescent liposome flow markers for microscale particle-image velocimetry.

Unilamellar liposomes carrying both encapsulated and surface-immobilized fluorophores have been synthesized as novel fluorescent markers to image flow profiles in microfabricated structures. The unilamellar liposomes were made with phospholipids and cholesterol by extrusion through a polycarbonate membrane. They contained carboxyfluorescein in the aqueous core and fluorescein-labeled lipids in the bilayer to render them both a surface and volume fluorescer, maximizing their fluorescence intensity. The lipid composition was chosen to impart a net negative charge to liposomes to minimize self-aggregation as well as interaction with negatively charged glass surfaces of the channels. These liposomes were monodisperse (mean diameter 283 nm), neutrally buoyant, and hydrophilic and exhibited no adsorption on glass surfaces. Unlike polystyrene spheres, they were readily broken up by surfactants, thereby allowing for easy and complete removal from microfluidic channels. The fluorescent liposomes were used to investigate pressure-driven flow in an offset cross intersection in a microfluidic chip and provided images with excellent signal-to-noise ratio. A novel computational scheme that is particularly suitable for analyzing particle-image velocimeby data in micrometer-scale flow channels was employed to anabze the images. These liposomes are easily synthesized and can be custom-made for various applications to offer a broad range of surface and volume characteristics such as charge, size, and surface chemistry.

Journal Article↗

Microchip injection and separation anomalies due to pressure effects.

While performing routine electroosmotically driven CE separations on microfluidic chips, we have observed peak shape, migration time, and baseline drift anomalies. Pressure-driven backflow (opposing electroosmotic flow (EOF)) has been observed and characterized, and meniscus surface tension (Laplace pressure) is cited as the likely cause. However, there are a number of interdependent factors that affect bulk flow in a microchip environment, including evaporation, buffer depletion due to hydrolysis, EOF pumping, siphoning, viscosity changes due to Joule heating, and Laplace pressure. Given the complexity of such a system, pressure effects were isolated from EOF, and to some extent, siphoning effects were isolated from suspected meniscus effects. Pressure flow observed in the absence of an applied field ranged from 0.4 to 0.8 mm/s, which was on the order of the EOF generated experimentally, 0.6 mm/s at a field of 150 V/cm, and was some 10-20 times larger than what would be predicted merely from a difference in liquid levels (siphoning). Furthermore, experiments were performed without an electric field and with the chip tilted so that meniscus flow ran "uphill" against a siphoning backflow and showed siphoning flow to have a negligible effect upon meniscus flow under the microchip conditions studied. These findings are relevant to the profusion of microfluidic and array-based technology that also use microliter liquid volumes in like-sized reservoirs with similar menisci.

Journal Article↗

Ultra-low-volume, real-time measurements of lactate from the single heart cell using microsystems technology.

The fabrication of microelectrodes integrated within ultra-low-volume microtiter chambers for the amperometric determination of metabolites continues to be of interest in the subject of single-cell and high-throughput screening. The microsystem described in this paper consists of a two-microelectrode sensor with a microfluidic dispensation technology, which is able to deliver both very low titers (6.5 pL) and single heart cells into a low-volume microphotoelectrochemical cell. Devices were fabricated using photolithography and liftoff giving reproducible sensors integrated within high aspect ratio titer chambers (with a volume of 360 pL), made of the photoepoxy SU8. In this paper, the determination of lactate was optimized using an enzyme-linked assay based upon lactate oxidase, involving the amperometric determination of hydrogen peroxide at +640 mV versus an internal Ag/AgCl pseudoreference. The microsystem (including the microfluidic dispensers and structures as well as the microsensor) was subsequently used to measure the lactate content of single heart cells. Dynamic electrochemical measurements of lactate during cell permeabilization are presented. We also show the use of respiratory uncouplers to simulate ischemia in the single myocyte and show that, as expected, the rate of lactate production from the hypoxic heart cell is greater than that within the normoxic healthy myocyte.

Indicators and Reagents↗

A microscale-molecular weight sensor: probing molecular diffusion between adjacent laminar flows by refractive index gradient detection.

A detection scheme that measures the refractive index gradient (RIG) between adjacent laminar flows in a microfluidic device has been used to develop a microscale-molecular weight sensor. The behavior of low Reynolds number flows has been well documented and shows that molecular transport (mixing) between adjacent laminar flows occurs by molecular diffusion between flow boundaries. A diode laser beam, incident upon and illuminating the entire width of a microchannel, measured the transverse concentration gradient at two different positions along a microchannel. The concentration gradient is impacted by the transverse diffusion from a flow with analyte into a flow initially without analyte. The RIG that forms as analyte diffuses from one adjacent flow to the other causes the laser beam, impinging orthogonal to the RIG through the microchannel, to be deflected. The angle of deflection is then monitored on a position-sensitive detector (PSD) at two different positions along the axis of flow to provide a measurement of analyte diffusion. The two positions are just after the flow initially without analyte merges with the flow initially containing all of the analyte (upstream) and then after the two streams have had more time to diffuse together (downstream). The ratio of the PSD signals obtained at the two positions along the flow, downstream signal divided by the upstream signal, is readily correlated to the analyte diffusion coefficient and, thus, the analyte molecular weight for a given class of compounds. The device was evaluated as a molecular weight sensor for poly(ethylene glycol) (PEG) solutions over a molar mass range from 106 to 22,800 g/mol. The ratio signal was found to be both independent of PEG concentration and sensitive to molecular weight changes for samples ranging from 960 to 22,800 g/mol. Independence of concentration is important for obtaining a reliable molecular weight measurement. The limit of detection for 11,840 g/mol PEG measured at the upstream detection position was determined to be 56 ppm, equivalent to 4.5 x 10(-6) RI (3sigma). This technique provides a much needed universal detection method, without requiring analyte derivatization chemistry (e.g., fluorescence), for microfluidic analyses that are becoming increasingly useful in monitoring chemical systems such as continuous-flow reactors or batch polymerization processes. Thus, the molecular weight determination capability is potentially applicable to other compound classes, such as DNA or proteins.

Journal Article↗

Experimental studies of electroosmotic flow dynamics in microfabricated devices during current monitoring experiments.

Electroosmotic flow (EOF) was monitored in glass microfluidic devices at rates up to 2 Hz with a precision of 0.2-1.0% using a technique based on the periodic photobleaching of a dilute, neutral fluorophore added to the running buffer. This EOF monitoring method was used to examine the performance of the current monitoring technique for measuring an average electroosmotic flow in a microfluidic device with a cross-T design. Flow measurements made with the current monitoring method gave a precision of 0.4-2.2%, but the periodic photobleaching method shows that the current monitoring technique causes changes in EOF as high as 41% during a single experiment. The periodic photobleaching method for EOF monitoring was also used to study EOF in channels on opposite sides of a cross-channel intersection. The opposite channels were shown to exhibit substantially different EOF dynamics during a current monitoring experiment as well as different steady-state EOF rates during normal operating conditions.

Journal Article↗

Total protein determinations by particle beam/hollow cathode optical emission spectroscopy.

A novel method for quantitative total protein determinations is presented. Total protein content is determined by particle beam/hollow cathode optical emission spectroscopy (PB/HC-OES) through monitoring of carbon atomic emission. The PB/HC-OES offers such advantages as ease of operation, exclusion of labor-intensive sample pretreatment processes, rapid analysis, high sensitivity, and low detection limit. The method could also be adapted to be integrated to current microfluidics devices. Parametric optimization for sample introduction, nebulization, desolvation, and hollow cathode source conditions is performed for the analysis of aqueous bovine serum albumin solutions. Response curves of C (I) 193.0-nm emission were obtained under the optimized conditions with both 10% HCl and 100 micromL KCl added to the sample matrix as potential carriers. The detection limit for triplicate injections of bovine serum albumin standards was found to be on the single-nanogram level with 200-microL injections. The addition of KCl significantly improved the sensitivity, supporting the proposed "carrier effect" of chloride salts in the particle transport process. Results obtained here suggest a range of applications for the use of the PB/HC-OES source for total protein determinations; emphasis here is future use in assessing protein quantification in microfluidic systems.

Electrodes↗

Stabilization of high-resistance seals in patch-clamp recordings by laminar flow.

The formation of a high-resistance electrical seal between a cell membrane and a glass micropipet tip is essential in patch-clamp experiments. We have studied the electrical properties and the mechanical stability of the seal using a microfluidic chip generating laminar flow in open volumes. We show that, by using fluid flow (1-10 mm/s) acting along the symmetry axis of the cell-pipet, seals of a higher mechanical stability with increased resistances can be achieved, allowing up to 100% longer recording times and over 40% decreased noise levels (Irms). These improved properties are beneficial for high-sensitivity patch-clamp recordings, in particular, in longtime studies of ion channel receptor systems that are relevant in biosensor applications of the technique. Furthermore, these observations support the combination of patch-clamp with microfluidic devices, for example, for rapid solution exchange around a single cell sensor for high-throughput electrophysiology and for highly resolved kinetic studies.

Journal Article↗

Induced pressure pumping in polymer microchannels via field-effect flow control.

Microfluidic field-effect flow control (FEFC) modifies the zeta potential of electroosmotic flow using a transverse electric field applied through the microchannel wall. Previously demonstrated in silicon-based and glass microsystems, FEFC is presented here as an elegant method for flow control in polymer-based microfluidics with a simple and low-cost fabrication process. In addition to direct FEFC flow modulation, independent transverse electric fields in connected microchannels are demonstrated to produce a differential pumping rate between the microchannels. The different electroosmotic pumping rates formed by local zeta potential control induce an internal pressure at the microchannel intersection, resulting in hydrodynamic pumping through an interconnecting field-free microchannel. Modulation of the voltages applied to the gate electrodes adjusts the magnitude and direction of the bidirectional pressure pumping, with fine resolution volume flow rates from -2 to 2 nL/min in the field-free microchannel demonstrated.

Journal Article↗

A monolithic silicon optoelectronic transducer as a real-time affinity biosensor.

An optical real-time affinity biosensor, which is based on a monolithic silicon optoelectronic transducer and a microfluidic module, is described. The transducer monolithically integrates silicon avalanche diodes as light sources, silicon nitride optical fibers, and p/n junction detectors and efficiently intercouples these elements through a self-alignment technique. The transducer surface is hydrophilized by oxygen plasma treatment, silanized with (3-aminopropyl)triethoxysilane and bioactivated through adsorption of the biomolecular probes. The use of a microfluidic module allows real-time monitoring of the binding reaction of the gold nanoparticle-labeled analytes with the immobilized probes. Their binding within the evanescent field at the surface of the optical fiber causes attenuated total reflection of the waveguided modes and reduction of the detector photocurrent. The biotin-streptavidin model assay was used for the evaluation of the analytical potentials of the device developed. Detection limits of 3.8 and 13 pM in terms of gold nanoparticle-labeled streptavidin were achieved for continuous- and stopped-flow assay modes, respectively. The detection sensitivity was improved by silver plating of the immobilized gold nanoparticles, and a detection limit of 20 fM was obtained after 20-min of silver plating. In addition, two different analytes, streptavidin and anti-mouse IgG, were simultaneously assayed on the same chip demonstrating the multianalyte potential of the sensor developed.

Adsorption↗

Hand-held microanalytical instrument for chip-based electrophoretic separations of proteins.

The design, fabrication, and demonstration of a hand-held microchip-based analytical instrument for detection and identification of proteins and other biomolecules are reported. The overall system, referred to as muChemLab, has a modular design that provides for reliability and flexibility and that facilitates rapid assembly, fluid and microchip replacement, troubleshooting, and sample analysis. Components include two independent separation modules that incorporate interchangeable fluid cartridges, a 2-cm-square fused-silica microfluidic chip, and a miniature laser-induced fluorescence detection module. A custom O-ring sealed manifold plate connects chip access ports to a fluids cartridge and a syringe injection port and provides sample introduction and world-to-chip interface. Other novel microfluidic connectors include capillary needle fittings for fluidic connection between septum-sealed fluid reservoirs and the manifold housing the chip, enabling rapid chip priming and fluids replacement. Programmable high-voltage power supplies provide bidirectional currents up to 100 microAlpha at 5000 V, enabling real-time current and voltage monitoring and facilitating troubleshooting and methods development. Laser-induced fluorescence detection allows picomolar (10(-11) M) detection sensitivity of fluorescent dyes and nanomolar sensitivity (10(-9) M) for fluorescamine-labeled proteins. Migration time reproducibility was significantly improved when separations were performed under constant current control (0.5-1%) as compared to constant voltage control (2-8%).

Electrophoresis, Microchip↗

Near-simultaneous and real-time detection of multiple analytes in affinity microcolumns.

A miniaturized immunoassay system based on beads in poly(dimethylsiloxane) microchannels for analyzing multiple analytes has been developed. The method involves real-time detection of soluble molecules binding to receptor-bearing microspheres, sequestered in affinity column format inside a microfluidic channel. Identification and quantitation of analytes occurs via direct fluorescence measurements or fluorescence resonance energy transfer. A preliminary account of this work based on single-analyte format has been published in this journal (Buranda, T.; Huang, J.; Perez-Luna, V. H.; Schreyer, B.; Sklar, L. A.; Lopez, G. P. Anal. Chem. 2002, 74, 1149-1156). We have extended the work to a multianalyte model system composed of discrete segments of beads that bear distinct receptors. Near-simultaneous and real-time detection of diverse analytes is demonstrated. The importance of this work is established in the exploration of important factors related to the design, assessment, and utility of affinity microcolumn sensors. First, beads derivatized with surface chemistry suitable for the attachment of fluorescently labeled biomolecules of interest are prepared and characterized in terms of functionality and receptor site densities by flow cytometry. Second, calibrated beads are incorporated in microfluidic channels. The analytical device that emerges replicates the basic elements of affinity chromatography with the advantages of microscale and real-time direct measurement of bound analyte on beads rather than the indirect determination from eluted sample typical of affinity chromatography. In addition, the two-compartment analysis of the assay data as demonstrated in single-analyte columns provides a template upon which the dynamics of multiple-analyte assays can be characterized using existing theoretical models and be tested experimentally. The assay can potentially detect subfemtomole quantities of protein with high signal-to-noise ratio and a large dynamic range spanning nearly 4 orders of magnitude in analyte concentration in microliter to submicroliter volumes of analyte fluid. The approach has the potential to be generalized to a host of bioaffinity assay methods including analysis of protein complexes (e.g., biomolecular indicators of diseases). Proof-of-principle analytes include FLAG peptide and carcinoembryonic antigen detected at physiologically relevant concentration levels.

Carcinoembryonic Antigen↗

Catalytic three-dimensional protein architectures.

We demonstrate a strategy for microfabricating catalytically active, three-dimensional matrixes composed of cross-linked protein in cellular and microfluidic environments. In this approach, a pulsed femtosecond laser is used to excite photosensitizers via multiphoton absorption within three-dimensionally defined volumes, a process that promotes cross-linking of protein residue side chains in the vicinity of the laser focal point. In this manner, it is possible to fabricate protein microparticles with dimensions on the order of the multiphoton focal volume (less than 1 microm(3)) or, by scanning the position of a laser focal point relative to a specimen, to generate surface-adherent matrixes or cables that extend through solution for hundreds of micrometers. We show that protein matrixes can be functionalized either through direct cross-linking of enzymes, by decoration of avidin matrixes with biotinylated enzymes, or by cross-linking biotinylated proteins that then are linked to biotinylated enzymes via an avidin couple. Several formats are explored, including microparticles that can be translocated to desired sites of action (including cytosolic positions), protein pads that generate product gradients within cell cultures, and on-column nanoreactors for microfluidic systems. These biomaterial fabrication technologies offer opportunities for studying a variety of cell functions, ranging from single-cell biochemistry and development to perturbation and analysis of small populations of cultured cells.

Animals↗

ESI-MS compatible permanent coating of glass surfaces using poly(ethylene glycol)-terminated alkoxysilanes for capillary zone electrophoretic protein separations.

Thin poly(ethylene glycol) silane (PEG-silane) coatings formed from N-(triethoxysilyl propyl)-O-poly(ethylene oxide) urethane with different chain lengths of poly(ethylene glycol) (MW 750 and 4000-5000) are used to modify glass microfluidic channels and fused-silica capillaries for electrophoretic separations of proteins. These coatings combine three important properties, which make them favorable for proteomic analyses including reduction of protein adsorption, compatibility with mass spectrometry due to their stability, and the ability to control the magnitude of electroosmotic flow (EOF). The coatings have been successfully used in microfluidic chips and fused-silica capillaries for separation of protein sample mixtures under low EOF conditions. The long-chain and mixed PEG-silane coatings suppress electroosmotic flow by more than 90%, whereas the short-chain PEG silane suppresses EOF by 65-75% at pH values of 3-9. The long-chain and mixed PEG-silane coatings are suitable for low EOF applications or for cases where negative effects of EOF are to be minimized. Efficient separations of unlabeled basic proteins at low pH and FITC-labeled proteins at high pH were achieved, as well as excellent stability for at least 200 electrophoretic runs. Additionally, these covalent coatings produce no detectable background ions in ESI-MS, making them compatible with on-line mass spectrometry.

Electrophoresis, Capillary↗

Continuous dielectrophoretic size-based particle sorting.

Continuous-flow dielectrophoretic (DEP) particle separation based on size is demonstrated in a microfluidic device. Polystyrene microspheres suspended in a neutrally buoyant aqueous solution are used as model particles to study DEP induced by an array of slanted, planar, interdigitated electrodes inside of a soft-lithography microchannel. The E-field gradients from the slanted electrodes impart a net transverse force component on the particles that causes them to "ratchet" across the channel. Over the length of the device, larger particles are deflected more than smaller particles according to the balance of hydrodynamic drag and DEP forces. Consequently, a flow-focused particle suspension containing different-sized particles is fractionated as the beads flow and separate down the length of the device. The flow behavior of spherical particles is modeled, and the total transverse particle displacement in the microfluidic device predicts fourth-order size and voltage and second-order inverse flow rate dependences. The model is verified experimentally for a range of flow rates, particle sizes, and E-field strengths.

Journal Article↗

Ionic liquid droplet as e-microreactor.

A powerful approach combining a droplet-based, open digital microfluidic lab-on-a-chip using task-specific ionic liquids as soluble supports to perform solution-phase synthesis is reported as a new tool for chemical applications. The negligible volatility of ionic liquids enables their use as stable droplet reactors on a chip surface under air. The concept was validated with different ionic liquids and with a multicomponent reaction. Indeed, we showed that different ionic liquids can be moved by electrowetting on dielectric (EWOD), and their displacement was compared with aqueous solutions. Furthermore, we showed that mixing ionic liquids droplets, each containing a different reagent, in "open" systems is an efficient way of carrying supported organic synthesis. This was applied to Grieco's tetrahydroquinolines synthesis with different reagents. Analysis of the final product was performed off-line and on-line, and the results were compared with those obtained in a conventional reaction flask. This technology opens the way to easy synthesis of minute amounts of compounds ad libitum without the use of complex, expensive, and bulky robots and allows complete automation of the process for embedded chemistry in a portable device. It offers several advantages, including simplicity of use, flexibility, and scalability, and appears to be complementary to conventional microfluidic lab-on-a-chip devices usually based on continuous-flow in microchannels.

Ions↗

Quantitative intracellular molecular profiling using a one-dimensional flow system.

We report on the development of one-dimensional microfluidic bead arrays for rapid and quantitative molecular profiling of human cancer cells. This new bioanalytical platform integrates the rapid binding kinetics of suspension bead carriers, the multiplexing and encoding capabilities of gene/protein chips, and the liquid handling advantages of microfluidic devices. Using antibody-conjugated beads in a two-site "sandwich" format, we demonstrate that the proteomic contents of as few as 56 human lung epithelial cancer cells can be determined with high sensitivity and specificity. The results indicate that each cell contains approximately 6 x 10(5) copies of the tumor suppressor protein P53. We have further examined the expression changes of P53, c-Myc, and beta-Actin as a function of anticancer drug treatment and have validated these changes by using Western blotting. This ability to quantitatively analyze normal and diseased cells raises new possibilities in studying cancer heterogeneity and circulating tumor cells.

Animals↗

Controlling desensitized states in ligand-receptor interaction studies with cyclic scanning patch-clamp protocols.

Ligand-gated ion channels are important control elements in regulation of cellular activities, and increasing evidence demonstrates their role as therapeutic targets. The receptors display complex desensitization kinetics, occurring on vastly different time scales. This is not only important in biology and pharmacology but might also be of technological significance since populations of receptors under microfluidic control can function analogously to DRAM memory circuits. Using a novel microfluidic method, and computer modeling of the receptor state distributions, we here demonstrate that GABAA receptor populations can be controlled to display high or low EC50 values, depending on input function (i.e., the exact pattern of agonist application). The sensitivity of the receptors can be tuned up to 40-fold (beta-alanine) by the particular agonist exposure pattern. By combining patch-clamp experiments with computer modeling of receptor state distributions, we can control the assembly of receptors in desensitized states. The technique described can be used as an analytical tool to study the effect of desensitization on the activity of ion channel effectors. We describe the differential blocking effect of the competitive antagonist bicuculline on the high- and low-EC50 GABAA receptor preparations and conclude that the inhibition is dramatically dependent on how the different desensitized states are populated. Furthermore, we show that both GABA and beta-alanine, two agonists with different affinity but similar efficacy, induce the same type of desensitization behavior and memory effects in GABAA receptors.

Animals↗