PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring, Intraoperative”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78Linked to original sources

The use of a non-invasive method to measure intrapulmonary shunt during one-lung anaesthesia.

The Non Invasive Virtual Shunt computer program has previously been described and validated. The system has subsequently been developed to give a real time, continuous trace of virtual shunt. A portable computer connected to routine monitoring equipment displays a plot of virtual shunt updated every 10 s. A practical use of this device in the clinical setting of one-lung anaesthesia is described. The equipment was used to monitor shunt before, during and after surgery in three patients. In one case, a displaced double lumen bronchial tube was detected before there was any other indication of the problem.

Adult↗

The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor.

This study was carried out to evaluate the ease of use and reliability of cardiac output estimations performed by an oesophageal Doppler monitor and to compare its use with that of a continuous cardiac output pulmonary flotation catheter. Measurements were made during and after surgery in 16 patients scheduled to undergo coronary revascularisation. Both devices suffered significant intra-operative problems which led us to question their suitability as operating theatre monitors. After surgery the continuous cardiac output monitor provided stable results while the oesophageal Doppler monitor required the continuous presence of an experienced anaesthetist to ensure comparable cardiac output estimations.

Aged↗

Electrochemical sensors for continuous monitoring during surgery and intensive care.

The current state of development of electrochemical sensors and biosensors for continuous use during surgery and intensive care is briefly reviewed with an emphasis on recent developments. The clinical usefulness of invasive and non-invasive sensors is discussed. Recent advances in the design of electrochemical sensors and experience with ex vivo and in vivo applications are described. The importance of developing appropriate fabrication technology is emphasised in order to meet the demand for reliable and reproducible analytical devices.

Animals↗

Static-charge-sensitive bed ballistocardiography in cardiovascular monitoring.

We evaluated the autonomic influence on balistocardiograms recorded by a static-charge-sensitive bed for cardiovascular monitoring in nine healthy males (20-44 years) and its clinical use in 11 patients who underwent coronary bypass surgery (51-59 years). The ballistocardiogram displayed a distorted low amplitude from the empty beating heart during bypass surgery, impaired by a reduced effective transmural filling pressure of the heart, and returned to its pre-bypass level when the preload to the heart and its pumping was restored. Submaximal dynamic exercise and isoprenaline caused the heart rate to rise to 90-114 beats min-1, and increased the ballistocardiographic amplitude threefold, while at the same time shortening the interval between the R-wave of the electrocardiogram and the peak of the ballistocardiographic waveform (P < 0.01). In contrast, atropine accelerated the heart rate to 96 beats min-1, but did not significantly change the amplitude or temporal pattern of the ballistocardiogram. Thus, the ballistocardiogram reflects sympathetic and parasympathetic influence on the contractility of the myocardium and the effect of cardiac filling (e.g. during bypass surgery).

Adult↗

Has transesophageal echocardiography changed the approach to patients with suspected or known infective endocarditis?

Infective endocarditis is still a great clinical challenge. Its diagnosis is difficult to establish, and mortality has remained around 30%. Early diagnosis and optimal treatment are crucial fo prognosis improvement. Echocardiography plays an indispensable role in the management of this disease, especially with the recently introduced approach, transesophageal echocardiography (TEE). TEE can overcome the limitations of transthoracic echocardiography (TTE) and is superior to TTE in almost every way in providing earlier and more information for the diagnosis and treatment of infective endocarditis. TEE detects valve vegetations with much higher sensitivity and specificity than TTE. It can demonstrate smaller vegetations in the early stage of the disease and vegetations on atypical locations (e.g., mitral valve annulus), and provides detailed characterization of vegetations (e.g., location, size, mobility, and changes during treatment). Such information is of great prognostic value and may help in selecting proper treatment. TEE is more sensitive for detecting complications, such as mitral valve perforation, abscess, and subaortic complications, which respond poorly to medicine and for which timely surgery may be the best treatment. For those with prosthetic valve endocarditis, TEE is especially useful because TTE is greatly limited by the acoustic shadow of prostheses. Both positive and negative results of TEE examination are valuable for confirming or excluding infective endocarditis. TEE also plays a unique role in intraoperative monitoring and can assess surgical results before the chest is closed. TEE has become an invaluable tool for the diagnosis and management of patients with suspected or known infective endocarditis.

Diagnosis, Differential↗

Echocardiography in Percutaneous Balloon Mitral Valvuloplasty.

Percutaneous balloon valvuloplasty (BV) has been used successfully in recent years for the relief of mitral stenosis, and in many instances, as an alternative to cardiac surgery. This procedure requires precise evaluation of both valve morphology and function for preprocedure decision making and follow-up of patients. Two-dimensional (2-D) echocardiography is a unique, noninvasive tool for evaluating morphologic characteristics of valve, subvalvular apparatus, and valve annular size. Doppler echocardiography provides functional information on transvalvular flow velocity, which can be used to derive pressure gradient across valve and regurgitant flow. Mitral valve area can be either obtained from 2-D echocardiography or derived from Doppler pressure half time. Echocardiography is currently the most widely used technique for assessing results of percutaneous BV. More recently, transesophageal echocardiography (TEE) has been used for the evaluation of patients undergoing percutaneous mitral BV in whom left atrial thrombus is suspected and for the intraoperative monitoring of the valvuloplasty procedure. In this article we discuss the advantages and limitations of both transthoracic echocardiography and TEE, its recent developments in monitoring the procedure, evaluation of immediate results and long term follow-up after the valvuloplasty procedure, and its clinical utility in the selection of patients for percutaneous BV.

Journal Article↗

Intraoperative Transgastric Echo Assessment During Left Ventricular Outflow Tract Surgery: A Reliable Predictor of Residual Obstruction.

Standard transesophageal echocardiography (TEE) views of the left ventricular outflow tract (LVOT) are limited by poor Doppler beam alignment with the peak velocity of flow. Transgastric imaging allows well-aligned continuous-wave Doppler interrogation of the LVOT and was attempted during intraoperative TEE in all children undergoing LVOT surgery at Children's Hospital of Wisconsin. Thirty-eight patients, ranging in age from 2 days to 18 years (median, 5.2 years) and in weight from 2.9 to 100 kg (median, 16.7 kg), had TEE during surgery to resect membranous or fibromuscular subaortic obstruction (20 patients), valvuloplasty for aortic stenosis/insufficiency (13 patients), aortoplasty for supravalvar stenosis (one patient), or repair/replacement for aortic insufficiency (four patients). In four patients, transgastric images of the LVOT could not be obtained. Intraoperative Doppler gradients identified severe residual obstruction (mean, 67 +/- 13.5 mmHg) after surgery in seven patients; six of these patients underwent immediate repeat operation with subsequent adequate relief, and one patient required later aortoventriculoplasty for persistent annular/valvar obstruction. All other patients had successful LVOT reconstruction with intraoperative Doppler gradients ranging from 0 to 46 mmHg, and none required early repeat operation. Good correlation was found between the intraoperative transgastric gradient (mean, 25.8 +/- 17.7 mmHg) and the early postoperative transthoracic echo gradient (mean, 21.8 +/- 21.4 mmHg). In addition, there was consistent agreement in the assessment of aortic insufficiency between the transesophageal and transthoracic studies. We conclude that transgastric Doppler assessment of the LVOT is a critical component of intraoperative monitoring during LVOT surgery and is a reliable predictor of residual obstruction.

Journal Article↗

Transcranial Doppler in 178 patients before, during, and after carotid endarterectomy.

From July 1991 to March 1995, 178 patients who underwent 198 carotid surgical repairs were investigated preoperatively, intraoperatively, and postoperatively by transcranial Doppler sonography (TCD). Preoperative TCD evaluation showed stenosis of the middle cerebral artery (MCA) in 4 patients (2.2%), siphon stenosis in 3 (1.6%), incomplete circle of Willis in 23 (12.9%), a decrease of mean blood flow velocity more than 70% of the basal value during digital common carotid compression in 31 (17.9%), and a critical reduction of vasomotor reactivity (no significant increase of mean blood flow velocity in the MCA during breath-holding test) in 34 (19.1%). Nine patients (5%) had surgery without preoperative angiography. In those patients the indication for surgery was based on color Doppler imaging and TCD investigations. Ninety surgical procedures were carried out under general anesthesia and 188 under locoregional anesthesia. In 37 surgeries (31.7%) a shunt was inserted. The use of a shunt was based on a decrease of mean blood flow velocity in the MCA below 50% of the basal value under general anesthesia or loss of consciousness combined with a decrease of mean blood flow velocity in the MCA higher than 70% of the basal value when locoregional anesthesia was employed. Intraoperative TCD monitoring showed a decrease of mean blood flow velocity in the MCA due to shunt malfunction in (8.3%) of 36 surgeries, turbulence of blood flow during declamping in 79 procedures (39.8%), and microembolic events in 10 patients (5%) that were related to one transient and one permanent neurological deficit. Another permanent deficit occurred in a patient without TCD signs. After surgery, TCD reliably detected an early asymptomatic occlusion of the carotid artery, hyperperfusion syndrome in 12 (6.0%), and an increase of vasomotor reactivity in 10 (29.4%) of 34 surgeries.

Anesthesia, Conduction↗

Spontaneous and evoked cortical dynamics during deep anaesthesia.

In this paper we have studied cortical dynamics as assessed using graphical methods during deep anaesthesia. Graphical analysis was carried out by autocorrelation functions and return maps with different lags. During moderate and deep anaesthesia, the electroencephalogram (EEG) shows a burst suppression pattern, consisting of abruptly-occurring high amplitude bursts alternating with periods of relative silence. Deep anaesthesia with burst suppression pattern provides a simple model of brain activity when the noise that is usually present in a subject who is awake is suppressed. During anaesthesia-induced EEG suppression, the brain reacts to different external stimuli with bursts. In respect to sensory processing during anaesthesia, it is interesting to know whether these bursts have different dynamics depending on the stimuli used. We have used graphical analysis to reveal the possible differences in bursts evoked by different stimuli. Externally evoked bursts were induced by auditory, electric and visual stimuli. The EEG studied in this paper consists of 25 bursts from one subject. We have estimated the autocorrelation function for each burst and used the formation gained from such autocorrelation coefficients as the grounds for determining different lags for return maps. The graphical methods used revealed differences in dynamics and topology of bursts as evoked by different stimuli. Spontaneous bursts clearly had different dynamics from evoked burst; which could not be seen directly from the raw EEG data. This study suggests that graphical analysis is a useful tool to obtain information about the dynamics of neuronal processes behind cortical responses during deep anaesthesia.

Action Potentials↗

Prospective study on the complication rate of carotid surgery.

BACKGROUND: Randomized trials of carotid endarterectomy for high-grade stenosis have shown a benefit for surgery under the condition of low perioperative complication rates. Concerns have been expressed that the complication rates of carotid surgery are higher in everyday practice and may vary considerably between centers. We prospectively established the complication rate for carotid surgery in a single institution. DESIGN: Prospective 2-year study. All patients received pre- and postoperative neurological evaluation. Laboratory tests included pre- and postoperative brain imaging, intracranial and neck vessel sonography, conventional angiography, magnetic resonance angiography, and intraoperative monitoring. PARTICIPANTS: 108 consecutive patients: 54 symptomatic patients fulfilling the inclusion criteria of the European Carotid Surgery Trial (ECST) and 54 asymptomatic patients fulfilling the inclusion criteria of the North American Trial on Asymptomatic Stenoses (ACAS). SETTING: Single academic center with a high volume of carotid endarterectomies (>50 per year). Participating center in ECST. MAIN OUTCOME MEASURES: Stroke or death as defined in the randomized trials. RESULTS: The overall complication rate was 8.3% (95% CI 4.1-15.6%). Complications were more frequent in patients with symptomatic stenosis (11.1%, CI 4.6-23.3%) than in asymptomatic cases (5.6%, CI 1.5-16.4%). Three patients died (2 strokes, 1 myocardial infarction). Disabling strokes were found in 2 patients (Rankin scale scores 3 and 4). Nondisabling strokes (Rankin scale score 1 and 2) occurred in 4 patients. The complication rates for symptomatic and asymptomatic patients were higher than the ones reported in the randomized trials, but 95% confidence intervals showed that the differences were not statistically significant. The point estimates of complication rates still supported a benefit of surgery for patients with symptomatic stenosis, but denied a positive effect of endarterectomy for patients with asymptomatic stenosis. CONCLUSION: In this center, a beneficial effect of carotid surgery for asymptomatic stenoses cannot be safely assumed.

Adult↗

Frequency analysis of involuntary movements during wrist tracking: a way to identify ms patients with tremor who benefit from thalamotomy.

To identify those multiple sclerosis (MS) patients with disabling tremor who will benefit most from thalamotomy, measurements of frequency spectra of involuntary movements during visually guided wrist tracking were carried out in 11 consecutive patients with MS before and after ventrolateral thalamotomy. Thalamotomy was significantly more effective if patients had disruptive action tremor which appeared as a single peak in the frequency spectra. Such patients showed an average reduction of nearly 80% in tremor magnitude after thalamotomy. In comparison, surgery produced an average reduction of only 30% in 3 other patients who had action tremor but showed multiple peaks in the frequency spectra. Frequency analysis of involuntary movements identifies those MS patients with disabling tremor who benefited most from thalamotomy.

Adult↗

Isocentric stereotactic three-dimensional digitizer for neurosurgery.

A new system has been developed, comprising a frameless isocentric stereotactic mechanism and a three-dimensional (3-D) digitizer for intraoperative spatial monitoring. The 3-D digitizer's multiarticulated arm has three joints related to Cartesian coordinates, two quadrant arcs forming an isocenter system, a microdrive, and a probe holder. The frameless isocentric mechanism is useful for open stereotaxy. Routine CT- or MRI-guided stereotactic surgery is also possible, due to the high level of accuracy of the system. Before surgery, CT and/or MR images are acquired after placing on the scalp three or four external markers. For surgical procedures which require high accuracy, Laitinen's noninvasive CT or MRI localizing markers are used. CT or MR images are entered into a computer using an image scanner, and are stored on a floppy disk. After the patient's head is fixed to the operating table using a Mayfield clamp, the 3-D digitizer is used to read the spatial points and external markers on the scalp or the reference points of Laitinen's localizing markers. During the procedure, the coordinates on the patient's head are automatically entered into the computer and matched with those of the 3-D digitizer and CT/MR images on the CRT display. This system has been used in 22 cases of open craniotomy and 33 cases of burr hole surgery, both carried out using the stereotactic function and the 3-D spatial monitoring function in parallel. Errors in mechanical accuracy of the 3-D digitizer were less than 0.8 mm, and the maximum error during operation was presumed not to exceed 2 mm.

Analog-Digital Conversion↗

Illi intracranial pressure monitoring and fixation device. A new fixation system for intracranial pressure monitoring in children and adolescents in paediatric neurotraumatology, hydrocephalus and craniofacial surgery.

Fixation and positioning of intracranial pressure (ICP) monitoring devices in small children with very thin skull bones pose serious problems. We present a new ICP fixation device with two movable components compressing the skull bone from in- and outside. This new fixation system, designed by PD Dr. O.E. Illi and licensed by White Spot AG, Surgical Tools and Research, Baar, Switzerland, guarantees far greater stability and reliability than conventional screws or bolts. It is fully compatible with a range of fiberoptic or pneumatic transducer systems. We have applied this new device successfully in 10 patients.

Adolescent↗

Blood pressure versus blood flow.

The pressure-volume diagram of the left ventricle is fundamental to understanding the mechanics of contraction and its modification by disease, drugs and anaesthetics. For monitoring patients perioperatively, we advocate variables derived from the pressure-volume diagram: cardiac output to monitor circulatory failure, pulmonary capillary wedge pressure to monitor the acute state of left ventricular filling and echocardiography to determine the chronicity and severity of chronic heart failure. Use of the pressure-volume diagram shows that whenever arterial pressure is raised by the use of vasoconstrictor agents, the flow of blood to the tissues is impaired. In patients in whom the heart is damage or failing, this adverse effect of raising arterial pressure causes further deterioration of circulatory failure and flow. In view of the prime need of the body tissues for blood flow, together with oxygen and substrates, it is advocated that vasoconstricting agents should not be used to maintain arterial pressure in the perioperative period. Plasma expansion and control of posture are preferred methods for maintaining the circulation. If circulatory failure continues in the presence of a high filling pressure of the left ventricle (wedge pressure), drugs combining positively inotropic and vasodilator properties are advocated.

Anesthesia, General↗