PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79Linked to original sources

Scanning temperature gradient focusing.

Temperature gradient focusing (TGF) is a recently developed technique for the simultaneous concentration and electrophoretic separation of ionic analytes in microfluidic channels. One drawback to TGF as it has previously been described is the limited peak capacity; only a small number of analyte peaks (approximately 2-3) can be simultaneously focused and separated. In this paper, we report on a variation of the TGF method whereby the bulk flow rate is varied over time so that a large number of analytes can be sequentially focused, moved past a fixed detection point, and flushed to waste. In addition to improved peak capacity, the detection limits of the scanning TGF method can be adjusted on-the-fly, as needed for different samples. Finally, scanning TGF provides a technique by which high-resolution, high-peak-capacity electrophoretic separations can be performed in simple, straight, and short microfluidic channels.

Journal Article↗

Protein nanopatterns and biosensors using gold binding polypeptide as a fusion partner.

An efficient strategy for immobilizing proteins on a gold surface was developed by employing the gold binding polypeptide (GBP) as a fusion partner. Using the enhanced green fluorescent protein (EGFP), severe acute respiratory syndrome coronavirus (SARS-CoV) envelope protein (SCVme), and core streptavidin (cSA) of Streptomyces avidinii as model proteins, specific immobilization of the GBP-fusion proteins onto the gold nanoparticles and generation of protein nanopatterns on the bare gold surface were demonstrated. The GBP-fused SCVme bound to gold nanoparticles successfully interacted with its antibody and showed changes in absorbance and color, allowing efficient diagnosis of SARS-CoV. The fusion proteins could be successfully immobilized on the gold surface by nanopatterning and microcontact printing as examined by atomic force microscopy and surface plasmon resonance analysis. The poly(dimethylsiloxane) microfluidic channels were created on the gold surface and were used for antigen-antibody and DNA-DNA interaction studies. Specific immobilization of GBP-EGFP fusion protein and its interaction with the antibody in the microchannels could be demonstrated. By immobilizing the DNA probe through the use of GBP-fused cSA, specific hybridization of the target DNA prepared from Salmonella could also be achieved. The GBP-fusion method allows immobilization of proteins onto the gold surface without surface modification and in bioactive forms suitable for studying protein-protein, DNA-DNA, and other biomolecular interaction studies. Furthermore, these studies can be carried out in a microfluidic system, which allows high-throughput analysis of biomolecular interactions.

Biological Assay↗

Dynamic DNA hybridization on a chip using paramagnetic beads.

Dynamic DNA hybridization is presented as an approach to perform gene expression analysis. The method is advantageous because of its dynamic supplies of both DNA samples and probes. The approach was demonstrated on a microfluidic platform by incorporating paramagnetic beads as a transportable solid support. A glass chip was fabricated to allow simultaneous interrogation of eight DNA target samples by DNA probes. DNA targets were immobilized on beads via streptavidin-biotin conjugation or base pairing between oligonucleotide residues. The DNA/bead complex was introduced into the device in which hybridization took place with a complementary probe. The hybridized probe was then removed by heat denaturation to allow the DNA sample to be interrogated again by another probe with a different sequence of interest. A pneumatic pumping apparatus was constructed to transport DNA probes and other reagents into the microfluidic device while hydrostatic pumping was used for the introduction of paramagnetic beads with samples. After investigating three types of paramagnetic beads, we found Dynabeads Oligo(dT)25 best suited this application. Targets on the beads could be sequentially interrogated by probes for 12 times, and the hybridization signal was maintained within experimental variation. Demonstration of specific hybridization reactions in an array format was achieved using four synthesized DNA targets in duplicate and five probes in sequence, indicating the potential application of this approach to gene expression analysis.

Actins↗

Laminar-flow-based separations at the microscale.

The natural separation maintained by microfluidic flows is employed as the basis of a particle/cell sorting device. This method of separating particulate suspensions exploits the inherent laminar nature of microscale fluid dynamics and incorporates applied fields and image cytometry to enable sorting based upon any visually identifiable difference between colloid-sized cells or particles. This technique may be used to easily isolate, separate, sort, or enrich virtually any suspension of microscale biological or colloidal particles within a microfluidic system. The entire footprint of the device described here is less than 0.01 mm(2), allowing it to be readily incorporated within highly integrated micro total analysis systems (microTAS).

Cell Separation↗

Kinetic measurements of protein conformation in a microchip.

This paper presents a microchip-based system for collecting kinetic time-based information on protein refolding and unfolding. Dynamic protein conformational change pathways were studied in microchannel flow using a microfluidic device. We present a protein-conserving approach for quantifying refolding by dynamically varying the concentration of the chemical denaturants, guanidine hydrochloride and urea. Short diffusion distances in the microchannel result in rapid equilibrium between protein and titrating solutions. Dilutions on the chip were tightly regulated using pressure controls rather than syringe-based flow, as verified with extensive on-chip tracer dye controls. To validate this protein assay method, folding transition experiments were performed using two well-characterized proteins, human serum albumin (HSA) and bovine carbonic anhydrase (BCA). Transition events were monitored through fluorescence intensity shifts of the protein dye 8-anilino-1-naphthalenesulfonic acid (ANS) during dilutions of protein from urea or guanidine hydrochloride solutions. The enzymatic activity of refolded BCA was measured by UV absorption through the conversion of p-nitrophenyl acetate (p-NPA). The microchip protein refolding transitions using ANS were well-correlated with conventional plate-based experiments. The microfluidic platform enables refolding studies to identify rapidly the optimal folding strategy for a protein using small quantities of material.

Animals↗

A synthetic reaction network: chemical amplification using nonequilibrium autocatalytic reactions coupled in time.

This article reports a functional chemical reaction network synthesized in a microfluidic device. This chemical network performs chemical 5000-fold amplification and shows a threshold response. It operates in a feedforward manner in two stages: the output of the first stage becomes the input of the second stage. Each stage of amplification is performed by a reaction autocatalytic in Co(2+). The microfluidic network is used to maintain the two chemical reactions away from equilibrium and control the interactions between them in time. Time control is achieved as described previously (Angew. Chem., Int. Ed. 2003, 42, 768) by compartmentalizing the reaction mixture inside plugs which are aqueous droplets carried through a microchannel by an immiscible fluorinated fluid. Autocatalytic reaction displayed sensitivity to mixing; more rapid mixing corresponded to slower reaction rates. Synthetic chemical reaction networks may help understand the function of biochemical reaction networks, the goal of systems biology. They may also find practical applications. For example, the system described here may be used to detect visually, in a simple format, picoliter volumes of nanomolar concentrations of Co(2+), an environmental pollutant.

Journal Article↗

Label-free molecular interaction determinations with nanoscale interferometry.

Quantification of protein-protein and ligand-substrate interactions is central to understanding basic cellular function and for evaluating therapeutics. To mimic biological conditions, such studies are best executed without modifying the proteins or ligands (i.e., label-free). While tools for label-free assays exist, they have limitations making them difficult to fully integrate into microfluidic devices. Furthermore, it has been problematic to reduce detection volumes for on-channel universal analyte quantification without compromising sensitivity, as needed in label-free methods. Here we show how backscattering interferometry in rectangular channels (BIRC) facilitates label-free studies within picoliter volumes. The simple and unique optical train was based on rectangular microfluidic channels molded in poly(dimethylsiloxane) and low-power coherent radiation. Quantification of irreversible streptavidin-biotin binding and reversible protein A-human IgG Fc molecular interactions in a 225 pL detection volume was carried out label-free and noninvasively. Detection limits of 47 x 10(-15) mol of biotin reacted with surface-immobilized streptavidin were achieved. In the case of reversible interactions of protein A and the Fc fragment of human IgG, detection limits were determined to be 2 x 10(-15) mol of IgG Fc. These experiments demonstrate for the first time that (1) high-sensitivity universal solute quantification is possible using interferometry performed within micrometer-sized channels formed in inexpensive PDMS chips, (2) label-free reversible molecular interaction can be studied with femtomoles of solute, and (3) BIRC has the potential to quantify binding affinities in a high-throughput format.

Biotin↗

Magnetically and biologically active bead-patterned hydrogels.

We present a new approach to the direct patterning of biologically and magnetically active microbeads in nonbiofouling polymer scaffolds for use in microfluidic devices. Briefly, the process involves treatment of a glass substrate, conformal contact bonding of a PDMS microchannel on the substrate, filling of the channel with beads and prepolymer solution, and UV-initiated photopolymerization of a mask-defined pattern using a standard inverted microscope. This versatile and simple method allows for the rapid fabrication of dispersed or packed bead patterns in poly(ethylene glycol) (PEG) hydrogels that are covalently linked to glass surfaces. By exploiting the relative opacity of the microbeads used, we are able to create both partially exposed and fully encapsulated bead patterns. To demonstrate the utility of this new technology, we separated magnetic bead-bound B lymphocytes from T lymphocytes on a PEG-encapsulated magnetic filtration platform and also captured B cells directly on patterned, protein-decorated beads in a flow-through microfluidic device. Beyond cell sorting, the accurate patterning of industrially standardized, chemically diverse microbeads may have significant implications for microchip-based analyte detection.

B-Lymphocytes↗

Formulation of vaccine adjuvant muramyldipeptides. 3. Processing optimization, characterization, and bioactivity of an emulsion vehicle.

An efficacious vaccine adjuvant which elicits both cell-mediated immunity (CMI) and humoral immune response was developed using [thr1]-Muramyldipeptide (MDP) in an oil-in-water emulsion vehicle containing poloxamer 401, polysorbate 80, and squalane. Processing optimization was performed to increase the physical stability of this adjuvant emulsion which, when prepared by conventional mixing methods, demonstrated good bioactivity but poor physical stability. Various manufacturing methods were compared with a microfluidization process, which produced the most stable and elegant emulsion vehicle. The microfluidized emulsion also elicited equivalent biological response in the animal model tested.

Acetylmuramyl-Alanyl-Isoglutamine↗

Continuous-flow lithography for high-throughput microparticle synthesis.

Precisely shaped polymeric particles and structures are widely used for applications in photonic materials, MEMS, biomaterials and self-assembly. Current approaches for particle synthesis are either batch processes or flow-through microfluidic schemes that are based on two-phase systems, limiting the throughput, shape and functionality of the particles. We report a one-phase method that combines the advantages of microscope projection photolithography and microfluidics to continuously form morphologically complex or multifunctional particles down to the colloidal length scale. Exploiting the inhibition of free-radical polymerization near PDMS surfaces, we are able to repeatedly pattern and flow rows of particles in less than 0.1 s, affording a throughput of near 100 particles per second using the simplest of device designs. Polymerization was also carried out across laminar, co-flowing streams to generate Janus particles containing different chemistries, whose relative proportions could be easily tuned. This new high-throughput technique offers unprecedented control over particle size, shape and anisotropy.

Journal Article↗

From a two-dimensional chemical pattern to a three-dimensional topology through selective inversion of a liquid-liquid bilayer.

Soft organic surfaces with more and more complex topologies are required daily to engineer appropriate microstructures for many different applications such as DNA array technology, biological optics for advanced photonic systems and microfluidics. Complementarily to conventional lithographic processes, several pioneering methods have been developed recently, by controlling phase separation of polymer blends, spinodal decomposition of homopolymers or by using the action of additional external forces driving diverse instabilities. Here we present a method that not only provides original concepts towards the three-dimensional (3D) structuring of liquids, on the basis of the synergistic effects of molecular diffusion and confined nucleation, but also suggests original solutions for the transport, mixing and filtering of small volumes of liquid. Through the intrinsic destabilization of a liquid-liquid bilayer, the 2D pattern of a chemically structured surface with 'hydrophilic' and 'hydrophobic' domains is transferred to a solid/liquid interface as a 3D topography with either 'positive' or 'negative' replication. This easy-to-use process has potential applications in various technological realms requiring a specific topography at interfaces such as microfluidics or biosensors.

Journal Article↗

A split microchannel design and analytical model to compensate for electroosmotic instabilities in micro-separations.

Organic polymers offer many advantages as materials for the construction of microfluidic devices but suffer frequently from the limitation that the electrodynamic flow they support can exhibit considerable instability. This article describes a split-channel microfluidic device that can be used to compensate for changes in electroosmotic flow. The design of the separation system divides an analyte plug after injection between two separation channels of differing length. The two channels are later recombined for single point detection, eliminating the need for a scanning optical detection system. The utility of this simple design lies in the fact that the migration time of any analyte can be referenced to its twin in the parallel separation channel. This eliminates the need for a separate electroosmotic marker and allows mobilities measured in multiple devices to be compared quantitatively. Using a model adopted from the literature, the data from the split channel system can be used to precisely account for the drift that characterizes electrophoretic separations made in a polymer chip. The relative standard deviations of the analyte mobilities measured for replicate runs on multiple devices were reduced from values as high as 20% to ca. 1% RSD. This internal standardization procedure also appears to address other sources of drift in the electroosmotic flow (EOF) supported by the polymer microchannel, eliminating the need for careful monitoring of either the temperature or reservoir pH between separation runs.

Journal Article↗

Analysis of river water samples utilising a prototype industrial sensing system for phosphorus based on micro-system technology.

The application of a phosphorus monitoring device based on microsystems technology (MST) to the analysis of river water is presented. An alternative to the standard molybdenum blue method known as the yellow vanadomolybdophosphoric acid method has been very effectively implemented. The method is simple, a reagent and sample are mixed in a 1:1 ratio forming a yellow complex that absorbs strongly below 400 nm in the UV spectrum. The kinetics of the reaction are rapid and sample turnaround is typically 3 min at room temperature. Therefore a very uncomplicated microfluidic design can be adopted. The working wavelength was chosen as 380 nm to coincide with the peak output of a UV-LED narrow bandwidth light source recently developed by Nichia. The limit of detection for the yellow method in the microfluidic system is 0.2 ppm with a dynamic linear range from 0-50 ppm. The method was applied to a measurement of phosphorus in a local river at specific sampling points along its course.

Absorption↗

Fixed-volume metering microdispenser module.

In this work, we present a novel fixed-volume metering microdispenser module using the sPROMs (structurally programmable microfluidic systems) technology. We have designed, simulated, fabricated and characterized an array of microdispensers with volumes ranging from 50 nL [nanoliter] to 150 nL. We have characterized several key components of the microdispenser, such as passive microvalves and the air-driven liquid column splitting process, using extensive simulations. The fabricated devices show extremely good accuracy (99.2%) and repeatability characteristics. We also present a simple technique for unloading the sub-microL [microliter] volumes from the microfluidic chip for measurement purposes. The dispensers realized in this work have immediate applications as a key ingredient of the lab-on-a-chip device.

Journal Article↗

Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation.

A highly effective, reagentless, mechanical cell lysis device integrated in microfluidic channels is reported. Sample preparation, specifically cell lysis, is a critical element in 'lab-on-chip' applications. However, traditional methods of cell lysis require purification steps or complicated fabrication steps that a simple mechanical method of lysis may avoid. A simple and effective mechanical cell lysis system is designed, microfabricated, and characterized to quantify the efficiency of cell lysis and biomolecule accessibility. The device functionality is based on a microfluidic filter region with nanostructured barbs created using a modified deep reactive ion etching process. Mechanical lysis is characterized by using a membrane impermeable dye. Three main mechanisms of micro-mechanical lysis are described. Quantitative measurements of accessible protein as compared to a chemically lysed sample are acquired with optical absorption measurements at 280 and 414 nm. At a flow rate of 300 microL min(-1) within the filter region total protein and hemoglobin accessibilities of 4.8% and 7.5% are observed respectively as compared to 1.9% and 3.2% for a filter without nanostructured barbs.

Animals↗

A non-invasive analysis method for on-chip spectrophotometric detection using liquid-core waveguiding within a 3D architecture.

The on-chip measurement of absorbing species has proven to be challenging, particularly with respect to the sample pathlengths available in a miniaturised system. This paper demonstrates how the principles of total internal reflection can be utilised to form a liquid-core waveguide along a single microfluidic channel, increasing the sampling pathlength to 5 mm while maintaining a detection volume of < or = 1 microL. This was achieved using the Teflon fluoropolymers PTFE, FEP and AF as cladding for the liquid-core waveguide. In conjunction with a 3D chip architecture, the use of the liquid-core waveguide enables more efficient use of the probing light beam along with easy and effective coupling of the source, microfluidic chip and the detection system. The confirmation that waveguiding was occurring was successfully demonstrated and the subsequent spectrophotometric analysis of crystal violet provided a linear calibration with reproducibility (< 2.4% RSD) and limits of detection (< 1.3 microM), comparable to absorbance measurements made with a standard UV-Vis spectrophotometer.

Journal Article↗

Fabrication of carbon microelectrodes with a micromolding technique and their use in microchip-based flow analyses.

In this paper, we report a new technique to pattern carbon microelectrodes for use in microfluidics. This technique, termed micromolding of carbon inks, uses poly(dimethylsiloxane)(PDMS) microchannels to define the size of the microelectrode. First, PDMS microchannels of the approximate dimensions desired for the microelectrode are made by soft lithography. The PDMS is then reversibly sealed to a substrate and the microchannels are filled with carbon ink. After a heating step the PDMS mold is removed, leaving a carbon microelectrode with a size slightly smaller than the original PDMS microchannel. The resulting microelectrode (27 microm wide and 6 microm in height) can be reversibly sealed to a PDMS-based flow channel. Fluorescence microscopy showed that no leakage occurred around the chip/electrode seal, even up to flow rates of 10 microL min(-1). The electrode was characterized by microchip-based flow injection analysis. Injections of catechol in Hank's Balanced Salt Solution (pH 7.4), showed a linear response from 2 mM to 10 microM (r(2)= 0.995), with a sensitivity of 56.5 pA microM(-1) and an estimated limit of detection of 2 microM (0.27 picomole, S/N=3). Reproducibility of the electrode response was shown by repeated injections (n= 10) of a 500 microM catechol solution, resulting in a RSD of 4.6%. Finally, selectivity was demonstrated by coating the microelectrode with Nafion, a perfluoronated cation exchange polymer. Dopamine exhibited a response at the modified microelectrode while ascorbic acid was rejected by the Nafion-coating. These electrodes provide inexpensive detectors for microfluidic applications while also being viable alternatives to use of other carbon microelectrode materials, such as carbon fibers. Furthermore, the manner in which the microelectrodes are produced will be of interest to researchers who do not have access to state of the art microfabrication facilities.

Carbon↗

Measuring reaction kinetics in a lab-on-a-chip by microcoil NMR.

A microfluidic chip with an integrated planar microcoil was developed for Nuclear Magnetic Resonance (NMR) spectroscopy on samples with volumes of less than a microliter. Real-time monitoring of imine formation from benzaldehyde and aniline in the microreactor chip by NMR was demonstrated. The reaction times in the chip can be set from 30 min down to ca. 2 s, the latter being the mixing time in the microfluidic chip. Design rules will be described to optimize the microreactor and detection coil in order to deal with the inherent sensitivity of NMR and to minimize magnetic field inhomogeneities and obtain sufficient spectral resolution.

Imines↗