PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring, Intraoperative”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79Linked to original sources

Cochlear potentials in clinical audiology.

The recording of cochlear and auditory nerve potentials in humans via Electrocochleography (ECochG) has emerged as a valuable tool for a variety of clinical applications. This review consolidates current research on the use of cochlear potentials and ECochG in the clinical setting and identifies several areas in need of additional study. Methodological topics discussed include a review of ECochG recording approaches (i.e. transtympanic versus extratympanic) and issues related to choice of stimuli (clicks versus tonebursts). The review of current applications for cochlear potentials focuses primarily on the use of ECochG in the identification and treatment of Ménière's disease/endolymphatic hydrops (MD/ELH). Other uses for ECochG also are presented (e.g. intraoperative monitoring, enhancement of ABR wave I, estimation of hearing sensitivity). Several suggestions are offered to maximize the predictive value of ECochG in the diagnosis of MD/ELH.

Audiometry, Evoked Response↗

Microembolic signals detected by transcranial Doppler sonography during carotid endarterectomy and correlation with serial diffusion-weighted imaging.

BACKGROUND AND PURPOSE: Embolic events are a major cause for procedure-related strokes after carotid endarterectomy (CEA). Transcranial Doppler sonography can reveal embolic events as microembolic signals (MES) during CEA. MES during declamping and shunting are frequently detected. MES during shunting are rare and known to be correlated with the neurological outcome of the patient. In the present study, we analyzed the occurrence of MES within different stages of CEA and whether MES within those stages were correlated with cerebral ischemia, as detected by diffusion-weighted imaging (DWI), and brain infarction, as detected by contrast-enhanced MRI. METHODS: Thirty-three patients were monitored intraoperatively for MES using transcranial Doppler sonography. DWI was performed within 24 hours before and after surgery. Positive postoperative DWI led to reexamination with contrast-enhanced T1-MRI 7 to 10 days after CEA for detection of cerebral infarction. RESULTS: MES were detected in 32 of 33 patients. The highest number of MES was found during shunting and declamping. A significant correlation was found between MES and DWI-lesions during dissection. A significant correlation was found between MES during dissection and shunting, and nonsignificant correlation was found between MES and the occurrence of cerebral infarction. CONCLUSIONS: MES could be regularly detected during CEA. Dissection and shunting seem to be the most vulnerable stages of the procedure.

Aged↗

Risks of carotid endarterectomy. Toronto Cerebrovascular Study Group.

An objective, retrospective review of 358 carotid endarterectomies performed in the neurosurgical teaching units of the University of Toronto in the year 1982 demonstrated a perioperative stroke rate of 3.9% and a death rate of 1.5%. Most (82%) surgical neurological complications occurred after the immediate post-operative period (24 hours). This high incidence of delayed stroke suggests that most perioperative strokes are embolic rather than hemodynamic. Careful operative technique and the use of anticoagulants and antiplatelet agents may be more important in preventing postoperative deficits than intraoperative monitoring and intraluminal shunting. Our figures and those of current published data indicate that a 5-6% combined morbidity and mortality should be expected in carotid endarterectomy. These data are critical both to decision making with the individual patient as well as in the planning of future carotid surgery trials.

Aged↗

Transcranial Doppler.

TCD recording of flow velocities in intracranial vessels was first described by Aaslid in 1982. The utility of this instrument becomes more apparent as it is used in different clinical settings and compared with angiographic findings (Figures 1 and 2). Its importance in early detection of vasospasm in subarachnoid hemorrhage is now clearly known; increased flow velocity can be documented prior to neurologic deterioration and thus allow early institution of therapy. In patients with stroke or transient ischemic attack of unclear etiology, especially in blacks, Orientals, or females, who have a higher incidence of intracranial arterial disease, TCD can be a very important noninvasive means for detecting stenosis of intracranial vessels. Its value for assessing collateral circulation, intraoperative monitoring, and measuring CBF is quite promising. Hopefully, through further work with TCD, we will be able to clarify the spectrum of its usages as well as its limitations, though the preliminary data indicate that it should be an important addition to present noninvasive evaluations.

Arterial Occlusive Diseases↗

Discrete cortical infarction with prominent impairment of thumb flexion.

BACKGROUND: Intracortical efferent zones in the primary motor cortex for thumb movements, namely thumb flexion, extension, adduction, and abduction, have been described in Macaca mulatta monkeys but not in humans. Even recent cortical mapping based on intraoperative monitoring does not provide information about intracortical efferent zones as it is not ethically possible to search the human motor cortex extensively by punctate electrodes. CASE DESCRIPTION: A 78-year-old man with discrete cortical embolism over the left central sulcus is described. Only a mild weakness of his right thumb was observed. Thumb flexion was affected to a greater degree than thumb extension, adduction, and abduction. The lesion ran along the bottom of the central sulcus and affected part of the precentral and postcentral gyri on both sides of it. Animal studies in Macaca mulatta monkeys have shown that the intracortical efferent zones for thumb movement, especially for thumb flexion, are located in the part of the motor cortex just adjoining the central sulcus that folds down from the "bank" to the depth of the central sulcus. It was possible to explain the prominent weakness of thumb flexion if we applied the results of the animal studies. CONCLUSIONS: Our case suggests that the same arrangement of intracortical efferent zones found in monkeys may also exist in human beings.

Aged↗

Current role of electroencephalography in cerebral ischemia.

BACKGROUND: The electroencephalogram has been largely supplanted by neuroimaging techniques for the diagnosis and localization of ischemic stroke. However, because of its close correlation with cerebral metabolism and its ability to detect brief transient alterations in cortical function, the electroencephalogram may still be useful for certain diagnostic applications in stroke. SUMMARY OF REVIEW: The relation of electroencephalographic phenomena to cerebral blood flow and metabolism is reviewed. Ten clinical questions that can be addressed by the electroencephalogram in patients with stroke are posed. The presence of seizures, confirmation of diagnosis, intraoperative monitoring, and level of consciousness are areas of proven usefulness. The electroencephalogram provides less worthwhile information about the time course, prognosis, and localization of strokes. Computerized techniques are of potential but unproven value. CONCLUSIONS: The electroencephalogram retains a worthwhile place in the evaluation of patients with cerebral ischemia when it is used to answer specific questions. All patients with strokes do not need electroencephalograms, but the test can provide uniquely useful data in some.

Brain Ischemia↗

Carotid angioplasty. Detection of embolic signals during and after the procedure.

BACKGROUND AND PURPOSE: Carotid angioplasty may offer an effective treatment for carotid stenosis, but there has been concern about the incidence and clinical consequences of distal embolization. Transcranial Doppler monitoring in carotid endarterectomy has demonstrated embolic signals during this procedure. We used this technique in patients undergoing carotid angioplasty. METHODS: Transcranial Doppler ultrasound was used to monitor for embolic signals in the ipsilateral middle cerebral artery before and during 10 technically successful carotid angioplasties and at various standardized times in the following month. RESULTS: In the month before angioplasty asymptomatic embolic signals were detected in 3 of 10 patients. During angioplasty multiple embolic signals were detected immediately after balloon inflation in 9 of 10 subjects. A minor ipsilateral cerebral ischemic event occurred in 1 of these 9, but the other 8 were asymptomatic. Embolic signals were common immediately after the procedure and intra-arterial femoral catheter removal (8 of 10 subjects) but thereafter became less frequent and were present in 1 of 5 at 4 hours, 2 of 10 at 48 hours, 1 of 6 at 7 days, and 1 of 10 at 1 month. CONCLUSIONS: Embolization at the time of carotid angioplasty is very common but usually asymptomatic; monitoring by means of Doppler ultrasound will allow the effectiveness of measures to reduce this embolization to be studied. Late embolization occurs in a minority of patients and may account for the small but significant risk of delayed stroke. Doppler monitoring may allow identification of patients at risk and assessment of the effectiveness of prophylactic therapy.

Aged↗

Recurrent laryngeal nerve localization using a microlaryngeal electrode.

Damage to the recurrent laryngeal nerve is a frequently seen complication in head and neck surgery. A system for intraoperative monitoring of the recurrent laryngeal nerve is presented. The key to this system lies in the use of a microlaryngeal electrode and inserter. Application of this system to various situations is described.

Electric Stimulation↗

Safety precautions for bronchoscopic Nd-YAG laser surgery.

The application of the neodymium-yttrium aluminum garnet (Nd-YAG) laser in bronchoscopy originated in Europe in 1981 and is now widespread in the United States. Transmissible through flexible fiberoptic quartz fibers and an efficient coagulator of tissue, the Nd-YAG laser deeply penetrates tissue not readily predictable by the endoscopist. Dangers associated with the Nd-YAG laser include complications secondary to inadvertent exposure to normal tissues or structures, tracheobronchial accidents (perforation, hemorrhage, fire), and complications related to anesthetic technique (respiratory depression). Hypoxemia related to persistent hemorrhage, accumulation of secretions or debris or both, or anesthesia-induced respiratory depression is the common denominator of most intraoperative and postoperative complications. Careful selection of patients, intraoperative monitoring of ventilation and blood gases, and techniques of rigid bronchoscopy are stressed to avoid complications.

Anesthesia↗

A cardiopulmonary bypass score system to assess quality of perfusion performance.

During cardiopulmonary bypass, the perfusionist maintains physiological parameters laid down in protocols; this is his or her performance capability. In order to assess his or her performance we need to be able to analyse these physiological parameters objectively. We defined six parameters, pH, BE, PaCO2, PaO2, ACT and oesophageal temperature and gave them ideal values of 7.40+/-0.05, 0.0+/-2.5 mmol/l, 39.0+/-3.0 mmHg, 150+/-50 mmHg, 540+/-60 s and 37.2+/-0.2 degrees C, respectively. We established ranges and a score system: +/- one standard deviation of the mean for a score of zero; between +/- one and two standard deviations for a score of one; and greater than +/- two standard deviations for a score of two. We captured and analysed the most outlying value, with respect to known normal values, for each parameter recorded on the pump sheet. This was performed for 100 consecutive patients. Mean +/- standard deviation (medians) values for pH, BE, PaCO2, PaO2, ACT and oesophageal temperature were 7.41+/-0.07 (7.41), -1.85+/-2.37 mmol/l (-1.85 mmol/l), 34.6+/-5.42 mmHg (34.0 mmHg), 320+/-96.2 mmHg (317 mmHg), 558+/-164 s (503 s) and 37.3+/-0.5 degrees C (37.4 degrees C), respectively. We then analysed what percentage of our 100 patients fell within each score range for each of the six parameters. This is an efficient means in analysing whether the perfusionist abides by the protocols, what quality is supplied to the patient, does he or she react when he or she is faced with parameters that are out of range and finally advocating in-line blood gas monitoring. This is another step towards our goal of total quality management.

Blood Gas Analysis↗

Fluid uptake in laser endometrial ablation.

Fluid uptake was measured from accurate preoperative and postoperative patient weights for 25 consecutive patients undergoing Nd:YAG laser endometrial ablation under general anaesthesia. One patient had a uterine perforation with 5.1 litres of fluid deposited in the peritoneal cavity. In the remaining 24 cases, maximum fluid uptake was 5.1 litres, three patients absorbed more than four litres and eight absorbed more than two litres. In those same 24 patients, the mean fluid uptake was 1.5 litres (SD 1.6) and six patients without tubal ligation had a higher mean uptake (2.2 litres, SD 1.7) than the eighteen with surgically occluded Fallopian tubes (1.3 litres, SD 1.4) but the difference was not statistically significant. Fluid uptake has the potential to cause significant morbidity in this procedure. Both procedure duration and volume of uterine irrigation fluid were poor predictors of fluid gain. Observation of the ongoing volume deficit between infused and collected fluid provided intraoperative monitoring of fluid gain that prevented complications from fluid overload in healthy patients. However, this method of monitoring fluid uptake may be insufficient to prevent either complications from glycine absorption, if glycine is used for irrigation, or fluid overload in patients with cardiac disease.

Adult↗

Comparative utility of technetium-99m hexamethylpropylenamine oxime single photon emission computed tomography (SPECT) with anatomic neuroimaging and electroencephalography (EEG) in childhood intractable epilepsy.

Intractable epilepsies pose a therapeutic challenge. Precise localization of the epileptic focus is imperative before planning surgical intervention. Functional imaging is an important component of presurgical work-up. Positron emission tomography is unavailable in developing countries; hence, the need to evaluate the available imaging modality, single photon emission computed tomography (SPECT), was felt. We investigated 61 children with intractable epilepsy, identified by predefined criteria, by performing electroencephalography (EEG), magnetic resonance imaging (MRI), computed tomography (CT), and ictal and interictal SPECT. The localizing value of ictal and interictal SPECT imaging for epileptic foci was correlated with clinical, electrophysiologic, and anatomic neuroimaging data. An ictal SPECT was obtained in 9, and interictal SPECT was performed in all (61). Ictal SPECT was localizing in 8 of 9 (88.8%). Interictal SPECT was localizing in a significantly higher proportion of patients (47.54%) than either the scalp EEG (16.39%) (P = .0003) or CT scan (21.56%) (P = .0046). Our data demonstrated that interictal and ictal SPECT identified more focal changes in children with intractable epilepsy than interictal EEG, CT, and probably MRI. The definitive proof of the SPECT-based findings being epileptogenic foci awaits correlation with intraoperative monitoring and postoperative follow-up.

Adolescent↗

Attenuation of somatosensory evoked potentials during positioning in a patient undergoing suboccipital craniectomy for Chiari I malformation with syringomyelia.

Intraoperative electrophysiologic monitoring can diminish the risk of neurologic injury by enabling the detection of injury at a time when it can be reversed or minimized. This report describes a 14-year-old girl with a Chiari's malformation type I and syringomyelia who underwent a suboccipital decompression and dural patch grafting with concurrent somatosensory evoked potentials. When the patient was turned into the prone position and the neck was flexed, the left-sided somatosensory evoked potential deteriorated. After the patient's neck was repositioned, the left median nerve potential improved but did not return to baseline. Postoperatively, the patient had decreased proprioception of her left arm, which completely resolved at 2-week follow-up. This single case report does not establish the need for routine somatosensory evoked potential monitoring. Nevertheless, deterioration of the potential in this case led directly to a change in the surgical positioning, which may have significantly reduced the chances of a permanent neurologic injury.

Adolescent↗

The use of transcranial magnetic stimulation for monitoring descending spinal cord motor function.

This report describes our initial clinical experience using transcranial magnetic stimulation for monitoring spinal cord motor function during surgical procedures. Motor evoked potentials were elicited using a cap shaped coil placed on the scalp of 27 patients while recording peripheral motor responses (compound muscle action potentials--CMAPs) from the upper (N = 1) or lower limbs (N = 26). Wherever possible, cortical somatosensory responses (SEPs) were also monitored by electrically stimulating the left and right posterior tibial nerve (N = 25) or the median nerve (N = 1). The judicious choice of anesthetic regimens resulted in successfully obtaining motor evoked responses (MEPs) in 21 of 27 patients and SEPs in 26 of 27 patients. Single pulse TMS resulted in peripheral muscle responses having large variability, whereas, the variability of SEPs was much less. Criteria based on response variability for assessing clinically significant changes in both MEPs and SEPs resulted in two false negative predictions for SEPs and none for MEPs when evaluating postoperative motor function. We recommend monitoring both sensory and motor pathways during procedures where placing the spinal cord at risk of damage.

Adult↗

Increased blood product use among coronary artery bypass patients prescribed preoperative aspirin and clopidogrel.

BACKGROUND: The administration of antiplatelet drugs before coronary artery bypass graft surgery (CABG) is associated with an increased risk of major hemorrhage and related surgical reexploration. Little is known about the relative effect of combined clopidogrel and aspirin on blood product use around the time of CABG. We evaluated the associated risk between the combined use of aspirin and clopidogrel and the transfusion of blood products perioperatively. METHODS: We retrospectively studied a cohort of 659 individuals who underwent a first CABG, without concomitant valvular or aortic surgery, at a single large Canadian cardiac surgical centre between January 2000 and April 2002. The four study exposure groups were those prescribed aspirin (n = 105), clopidogrel (n = 11), the combination of both (n = 46), or neither drug (n = 497), within 7 days prior to CABG. The primary study outcome was the excessive transfusion of blood products during CABG and up to the second post-operative day, defined as > or = 2 units of packed red blood cells (PRBC), > or = 2 units of fresh frozen plasma, > or = 5 units of cryoprecipitate or > or = 5 units of platelets. Secondary outcomes included the mean number of transfused units of each type of blood product. RESULTS: A greater mean number of units of PRBC were transfused among those who received clopidogrel alone (2.9) or in combination with aspirin (2.4), compared to those on aspirin alone (1.9) or neither antiplatelet drug (1.4) (P = 0.001). A similar trend was seen for the respective mean number of transfused units of platelets (3.6, 3.7, 1.3 and 1.0; P < 0.001) and fresh frozen plasma (2.5, 3.1, 2.3, 1.6; P = 0.01). Compared to non-users, the associated risk of excessive blood product transfusion was highest among recipients of aspirin and clopidogrel together (adjusted OR 2.2, 95% CI 1.1-4.3). No significant association was seen among lone users of aspirin (adjusted OR 1.0, 95% CI 0.6-1.6) or clopidogrel (adjusted OR 0.7, 95% CI 0.2-2.5), compared to non-users. CONCLUSIONS: While combined use of aspirin and clopidogrel shortly before CABG surgery may increase the associated risk of excess transfusion of blood products perioperatively, several study limitations prevent any confident conclusions from being drawn. Beyond challenging these findings, future research might focus on the value of both intraoperative monitoring of platelet function, and the effectiveness of antifibrinolytic agents, at reducing the risk of postoperative bleeding.

Aged↗

Cytokine levels and systemic toxicity in patients undergoing isolated limb perfusion with high-dose tumor necrosis factor, interferon gamma, and melphalan.

PURPOSE: Isolated limb perfusion (ILP) with tumor necrosis factor (TNF), interferon gamma, and melphalan (M) has been reported to result in high response rates for extremity melanoma and sarcoma. We have evaluated the relationship of systemic TNF exposure to induction of several secondary mediators and incidence of systemic toxicity. PATIENTS AND METHODS: Nineteen patients with extremity melanoma (n = 16) or sarcoma (n = 3), underwent 90-minute ILP with TNF-alpha, interferon gamma (0.2 mg), and M (10 to 13 mg/L of limb volume) (TNF/IFN/M) (n = 12), or M alone (n = 7). Continuous intraoperative monitoring (CIM) for systemic leak from the perfusion circuit was performed using radioactive iodine-131 albumin. Cytokine levels in the perfusate and systemic circulation during and after ILP were measured by enzyme-linked immunosorbent assay. RESULTS: Systemic leaks > or = 1% from the perfusion circuit occurred in six patients who received TNF/IFN/M and in four who received M alone. Hypotension that required vasopressor support occurred in six of six patients with evidence of a leak (> or = 1%) and zero of six patients without a leak (< 1%). These six patients had significantly higher peak systemic TNF levels during and after perfusion than patients without a leak (2.8 and 8.2 ng/mL v 0.7 and 2.0 ng/mL, respectively; P < .05). All patients who received TNF/IFN/M had significantly greater increases in systemic interleukin-6 (IL-6) levels than in patients with M alone (12,395 +/- 10,374 pg/mL v 79.4 +/- 7.2 pg/mL, respectively; P < .001). Intracellular adhesion molecule (ICAM), IL-8, and TNF-R levels were also increased after ILP with TNF/IFN/M. CONCLUSION: ILP with TNF/IFN/M can be safely performed, as I131 albumin provides a sensitive measure of systemic leakage from the perfusion circuit. Patients with a measured leak of > or = 1% develop mild and transient postoperative hypotension with significantly higher systemic TNF levels and lower perfusate TNF levels than in patients without leaks.

Adult↗