[On the behavior of pressure in the pulmonary artery following surgery for mitral valve stenosis].
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Seventeen consecutive newborn and premature babies with critical pulmonary stenosis underwent a technically successful balloon valvuloplasty at our institution from March 1991 to February 1998. The only major complication was a thrombosis of the femoral vein in one patient, causing no clinical problems. Four patients (24%) showed a reactive infundibular obstruction after balloon valvuloplasty. The outflow tract obstruction became evident immediately after successful dilatation of the pulmonary valve with persistently high pressures in the right ventricle. Pathognomonic was a typical notch in the ascending part of the right ventricular pressure curve. We were unable to predict this reaction based on echocardiography or angiography. To relieve the muscular subvalvar obstruction, we treated the first two patients with i.v. Propranolol (0.05 mg/kg over 2 min). The last 2 patients received Esmolol (0.5 mg/kg over 2 min followed by a continuous infusion with 100 micrograms/kg/min), a very short acting beta-blocker. In the medium-term follow-up, all 17 patients had a very good result with only mild pulmonary valve regurgitation. All 4 patients with a reactive infundibular obstruction required no repeat intervention. In the medium-term follow-up there were no differences between these 4 patients and the whole group.
The relation between the size of the balloon used for dilatation of the pulmonary valve and the extent of relief of pulmonary stenosis both immediately after and at intermediate term follow up was studied. Sixty four balloon dilatation procedures in 56 patients were divided into group 1-12 in which the ratio of the diameter of the balloon to that of the pulmonary annulus was less than or equal to 1.0--and group 2-52 in which the ratio was greater than 1.0. Both groups had similar mean (SD) pressure drops across the pulmonary valve before dilatation. Immediately after dilatation there was a significant reduction in the pulmonary valve gradient in both group 1 (84.3 (39.2) v 43.6 (26.8) mm Hg) and group 2 (92.8 (42.1) v 22.4 (13.6)mm Hg). On intermediate term follow up (6-34 months), residual pulmonary valve gradients were significantly lower in group 2 (20.8 (18.5)mm Hg) than in group 1 (75.0 (49.4) mm Hg), suggesting that restenosis was more common after dilatation with small balloons. These data suggest that although the immediate results with either small or large balloons are good, balloons that are larger than the pulmonary valve annulus produce more sustained relief of pulmonary stenosis. Further analysis within the group treated with larger balloons showed that the subgroup with a balloon/annulus ratio of 1.01-1.2 had more recurrences of stenosis (need for repeat balloon dilatation and larger number of patients with residual pulmonary valve gradients greater than 30 mm Hg) than subgroups with balloon/annulus ratios for diameters of 1.21-1.41, greater than 1.41, and greater than 1.5, in which there were no recurrences. Balloons that were > 1.5 times the size of the pulmonary valve annulus had no additional advantage over the other subgroups, namely, 1.21-- 1.4 and > 1.41. These results and reports of damage to the right ventricular outflow tract by oversized (> 1.5) balloons indicate that balloons that give a balloon/annulus ratio 1.2 -- 1.5 are the best for dilatation of the pulmonary valve.
The possibility of an etiological relationship between rubella embryopathy and sporadic forms of supravalvular aortic stenosis is considered. A case is presented of a patient with rubella embryopathy and supravalvular aortic stenosis associated with pulmonary valvular and peripheral pulmonary artery stenosis, bicuspid aortic valve, aortic valve stenosis and subendothelial myocardial fibrosis. A review of the literature revealed many clinical and pathological features common to both syndromes. The hypothesis that rubella virus produced germ-cell mutation and subsequent persistence of rubella in the zygote produced further fetal damage is presented to explain these observations.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.