PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79Linked to original sources

Resolution improvement in positron emission tomography using anatomical Magnetic Resonance Imaging.

An ideal imaging system should provide information with high-sensitivity, high spatial, and temporal resolution. Unfortunately, it is not possible to satisfy all of these desired features in a single modality. In this paper, we discuss methods to improve the spatial resolution in positron emission imaging (PET) using a priori information from Magnetic Resonance Imaging (MRI). Our approach uses an image restoration algorithm based on the maximization of mutual information (MMI), which has found significant success for optimizing multimodal image registration. The MMI criterion is used to estimate the parameters in the Sharpness-Constrained Wiener filter. The generated filter is then applied to restore PET images of a realistic digital brain phantom. The resulting restored images show improved resolution and better signal-to-noise ratio compared to the interpolated PET images. We conclude that a Sharpness-Constrained Wiener filter having parameters optimized from a MMI criterion may be useful for restoring spatial resolution in PET based on a priori information from correlated MRI.

Algorithms↗

Electron spectroscopic imaging for high-resolution immunocytochemistry: use of boronated protein A.

In the present study we adapted electron spectroscopic imaging (ESI) for high-resolution immunocytochemistry. To accomplish this, we applied boronated protein A (B-pA) for indirect detection of specific antigenic sites using pre-embedding and post-embedding protocols. Isolated acinar cells were exposed to wheat germ agglutinin (WGA) and anti-WGA, followed by B-pA, to reveal WGA binding sites at the level of the plasma membrane. The cells were then embedded in Epon and unstained ultra-thin sections were examined by electron microscopy using the ESI mode. For post-embedding, ultra-thin sections of glutaraldehyde-fixed, Lowicryl-embedded pancreatic tissue were exposed to specific antibodies (anti-insulin or anti-amylase), followed by B-pA. The unstained sections were examined using the ESI mode. In both cases, boron was detected with high resolution either at the level of the plasma membrane of acinar cells, demonstrating WGA binding sites, or over secretory granules in pancreatic insulin-secreting cells or acinar cells, demonstrating insulin and amylase, respectively. These findings were compared to those obtained with the protein A-gold technique, and have demonstrated the analogy of both types of labeling. In addition, several control experiments assessed this novel approach. They have demonstrated the specificity of labeling and the high reactivity of B-pA, as well as its antibody-binding properties. Finally, electron energy loss spectral analysis confirmed the presence of boron in the tissue sections at sites where immunolabeling was detected. These results demonstrate that ESI is an appropriate approach for cytochemistry. Since the technique is based on detection of elements, spatial resolution is considered to be in the magnitude of 0.5 nm, which represents a major improvement in resolution over actual electron microscopic cytochemical techniques.

Animals↗

High-resolution computed tomography scanning in alpha1-antitrypsin deficiency: relationship to lung function and health status.

The development of computed tomography (CT) has enabled emphysema to be assessed noninvasively. Objective quantification of lung density correlates well with lung function in patients with chronic obstructive pulmonary disease and has been shown to be a sensitive tool for monitoring disease progression. In order to determine the clinical impact of changes seen on high-resolution computed tomography (HRCT), the relationship between the objective quantification of emphysema on HRCT, lung function and health status in 111 patients with alpha1-antitrypsin deficiency was examined (PiZ). The degree of HRCT scan abnormality correlated well (p<0.001 for all comparisons) with forced expiratory volume in one second (r = -0.60- -0.75), specific airway conductance (r = -0.67-0.76), residual volume/total lung capacity (r = 0.46-0.58) and transfer factor of the lung for carbon monoxide (r = -0.64- -0.81). In addition, the CT scans correlated (p<0.001) with health status as assessed by the St. George's Respiratory Questionnaire (SGRQ total: r = -0.38-0.50) and the Short-Form health survey (e.g. physical functioning: r = -0.39-0.54). In summary, other workers have shown high-resolution computed tomography to be a sensitive indicator of disease progression. This study confirms the relationship between high-resolution computed tomography and lung physiology, and suggests the relationship is even stronger in patients with predominantly lower zone pan-lobular emphysema than in usual chronic obstructive pulmonary disease. High-resolution computed tomography also relates to patients disability and impairment as defined by health status questionnaires and, therefore, should be considered as an alternative outcome measure particularly in alpha1-antitrypsin deficiency.

Adult↗

Persistence of lung inflammation and lung cytokines with high-resolution CT abnormalities during recovery from SARS.

BACKGROUND: During the acute phase of severe acute respiratory syndrome (SARS), mononuclear cells infiltration, alveolar cell desquamation and hyaline membrane formation have been described, together with dysregulation of plasma cytokine levels. Persistent high-resolution computed tomography (HRCT) abnormalities occur in SARS patients up to 40 days after recovery. METHODS: To determine further the time course of recovery of lung inflammation, we investigated the HRCT and inflammatory profiles, and coronavirus persistence in bronchoalveolar lavage fluid (BALF) of 12 patients at recovery at 60 and 90 days. RESULTS: At 60 days, compared to normal controls, SARS patients had increased cellularity of BALF with increased alveolar macrophages (AM) and CD8 cells. HRCT scores were increased and correlated with T-cell numbers and their subpopulations, and inversely with CD4/CD8 ratio. TNF-alpha, IL-6, IL-8, RANTES and MCP-1 levels were increased. Viral particles in AM were detected by electron microscopy in 7 of 12 SARS patients with high HRCT score. On day 90, HRCT scores improved significantly in 10 of 12 patients, with normalization of BALF cell counts in 6 of 12 patients with repeat bronchoscopy. Pulse steroid therapy and prolonged fever were two independent factors associated with delayed resolution of pneumonitis, in this non-randomized, retrospective analysis. CONCLUSION: Resolution of pneumonitis is delayed in some patients during SARS recovery and may be associated with delayed clearance of coronavirus, Complete resolution may occur by 90 days or later.

Adolescent↗

A high resolution physical and RH map of pig chromosome 6q1.2 and comparative analysis with human chromosome 19q13.1.

BACKGROUND: The generation of BAC/PAC contigs in targeted genome regions is a powerful method to establish high-resolution physical maps. In domestic animal species the generation of such contigs is typically initiated with the screening of libraries with probes derived from human genes that are expected to be located in the region of interest by comparative mapping. However, in many instances the available gene-derived probes are too far apart to allow the cloning of BAC/PAC contigs larger than a few hundred kb. High resolution physical mapping allows to estimate the sizes of gaps and to control the orientation of the individual sub-contigs, which helps to avoid errors during the assembly of smaller contigs into final Mb-sized contigs. The recently constructed porcine IMNpRH2 panel allowed us to use this approach for the construction of high-resolution physical maps of SSC 6q1.2. RESULTS: Two sequence-ready BAC/PAC contigs of the gene-rich region on porcine chromosome 6q1.2 (SSC 6q1.2) containing the RYRl gene were constructed. The two contigs spanned about 1.2 Mb and 2.0 Mb respectively. The construction of these contigs was monitored by the results provided by the mapping of 15 markers on the IMpRH(7000rad) and 35 markers on the IMNpRH2(12000rad) radiation hybrid panels. Analyses on the IMpRH panel allowed us to globally link and orientate preliminary smaller contigs, whereas analyses on the high resolution IMNpRH2 panel allowed us to finally identify the order of genes and markers. CONCLUSIONS: A framework map of 523 cR12000 was established covering the whole studied region. The order of markers on the framework 1000:1 RH map was found totally consistent with the data deduced from the contig map. The kb/cR ratio was very constant in the whole region, with an average value of 6.6 kb/cR. We estimate that the size of the remaining gap between the two contigs is of about 300 kb. The integrated physical and RH map of the investigated region on SSC 6q1.2 was used for a comparative analysis with respect to the syntenic regions on HSA 19q13.1 and MMU 7 and revealed a perfectly conserved gene order across the entire studied interval.

Animals↗

Health-related quality of life improves with treatment-related GERD symptom resolution after adjusting for baseline severity.

Severity and frequency of gastroesophageal reflux disease (GERD) related symptoms are associated with impaired health-related quality of life (HRQL). This study evaluated the association between baseline heartburn severity and endpoint HRQL of patients treated for heartburn and the relationship between complete resolution of heartburn symptoms and HRQL outcomes after controlling for baseline severity. We completed a secondary analysis of clinical symptom and HRQL data from three clinical trials in adult patients receiving either omeprazole or ranitidine treatment for GERD. HRQL was assessed using the Psychological General Well-Being Index (PGWB) in each of the three clinical trials, and two of the trials also included the Medical Outcomes Study Sleep disturbance scale. Gastrointestinal symptoms were evaluated using either the Gastrointestinal Symptom Rating Scale or a modified version of the scale. Baseline heartburn severity (none/minor, mild, moderate or severe) was defined based on patient-reported symptoms. Analysis of covariance (ANCOVA) models were used to compare mean HRQL scores by baseline level of heartburn symptom severity and whether or not patients experienced complete heartburn resolution. At baseline, PGWB scores were significantly worse (p < 0.05) for patients with more severe heartburn symptoms. There were no statistically significant baseline severity by symptom resolution interactions in any of the ANCOVA models. For all three trials and across all follow-up assessments, mean PGWB scores were statistically significantly higher for patients with completely resolved heartburn symptoms versus those whose symptoms were unresolved (all p-values < 0.05). Few significant effects were observed for sleep disturbance scores. While the severity of heartburn symptoms at the start of medical treatment for GERD is not associated with improvements in HRQL in subsequent weeks of treatment, complete resolution of symptoms is associated with improvements in psychological well-being.

Adult↗

High resolution genomic analysis of sporadic breast cancer using array-based comparative genomic hybridization.

INTRODUCTION: Genomic aberrations in the form of subchromosomal DNA copy number changes are a hallmark of epithelial cancers, including breast cancer. The goal of the present study was to analyze such aberrations in breast cancer at high resolution. METHODS: We employed high-resolution array comparative genomic hybridization with 4,134 bacterial artificial chromosomes that cover the genome at 0.9 megabase resolution to analyze 47 primary breast tumors and 18 breast cancer cell lines. RESULTS: Common amplicons included 8q24.3 (amplified in 79% of tumors, with 5/47 exhibiting high level amplification), 1q32.1 and 16p13.3 (amplified in 66% and 57% of tumors, respectively). Moreover, we found several positive correlations between specific amplicons from different chromosomes, suggesting the existence of cooperating genetic loci. Queried by gene, the most frequently amplified kinase was PTK2 (79% of tumors), whereas the most frequently lost kinase was PTK2B (hemizygous loss in 34% of tumors). Amplification of ERBB2 as measured by comparative genomic hybridization (CGH) correlated closely with ERBB2 DNA and RNA levels measured by quantitative PCR as well as with ERBB2 protein levels. The overall frequency of recurrent losses was lower, with no region lost in more than 50% of tumors; the most frequently lost tumor suppressor gene was RB1 (hemizygous loss in 26% of tumors). Finally, we find that specific copy number changes in cell lines closely mimicked those in primary tumors, with an overall Pearson correlation coefficient of 0.843 for gains and 0.734 for losses. CONCLUSION: High resolution CGH analysis of breast cancer reveals several regions where DNA copy number is commonly gained or lost, that non-random correlations between specific amplicons exist, and that specific genetic alterations are maintained in breast cancer cell lines despite repeat passage in tissue culture. These observations suggest that genes within these regions are critical to the malignant phenotype and may thus serve as future therapeutic targets.

Breast Neoplasms↗

Intraventricular thrombolysis speeds blood clot resolution: results of a pilot, prospective, randomized, double-blind, controlled trial.

OBJECTIVE: Animal models and clinical studies suggest that intraventricular thrombolysis improves clot resolution and clinical outcomes among patients with intraventricular hemorrhage. However, this intervention may increase the rates of rebleeding and infection. To assess the safety and efficacy of intraventricular thrombolysis, we conducted a pilot, randomized, double-blind, controlled, multicenter study. METHODS: Patients with intraventricular hemorrhage requiring ventriculostomy were randomized to receive intraventricular injections of normal saline solution or urokinase (25000 international units) at 12-hour intervals. Injections continued until ventricular drainage was discontinued according to prespecified clinical criteria. Head computed tomographic scans were obtained daily, for quantitative determinations of intraventricular hemorrhage volumes. The rate of clot resolution was estimated for each group. RESULTS: Twelve subjects were enrolled (urokinase, seven patients; placebo, five patients). Commercial withdrawal of urokinase precluded additional enrollment. The urokinase and placebo groups were similar with respect to age (49.6 versus 55.2 yr, P = 0.43) and presenting Glasgow Coma Scale scores (7.14 versus 8.00, P = 0.72). Randomization to the urokinase treatment arm (P = 0.02) and female sex (P = 0.008) favorably affected the clot resolution rate. The sex-adjusted clot half-life for the urokinase-treated group was reduced 44.6%, compared with the value for the placebo group (4.69 versus 8.48 d). CONCLUSION: Intraventricular thrombolysis with urokinase speeds the resolution of intraventricular blood clots, compared with treatment with ventricular drainage alone.

Adult↗

Computerized axial tomography: estimation of spatial and density resolution capability.

The spatial and density resolution capability of the EMI-Scanner device for computerized axial tomography has been determined in vitro. For density differences greater than +/-1 per cent the spatial resolution is 6 X 6 mm. For density differences of 3 per cent and greater the resolution is 3 X 3 mm. Density resolution is at least +/-1 per cent for objects greater than 1 cm. Preliminary data on in vitro measurement of X-ray linear attenuation coefficients in tissue biopsies and standard solutions are given, together with the early results of enhancement of tissue density differences in vivo. Implications of this new technique for an in vivo neuropathology are suggested.

Brain Diseases↗

Comparison of photodensitometric with high-resolution digital analysis of bone density from serial dental radiographs.

Photodensitometry is known to provide high spatial resolution and continuous measurement of optical density for the analysis of dental radiographs, whereas digitization allows powerful image manipulations but, when using conventional video cameras, gives less spatial resolution and fewer grey levels. The aim of this study was therefore to develop a technique of high-resolution digital analysis for the measurement of bone density following the same principles as those of photodensitometry and based upon the use of a CCD Scanner Camera which provides up to 4096 grey levels and a spatial resolution of 4096 x 4096 pixels. Twenty-four zones were analysed with both techniques in five serial dental radiographs taken before and after periodontal therapy in eight patients. Statistical comparison of the results obtained by digital analysis and photodensitometry shows that the two techniques have the same accuracy.

Absorptiometry, Photon↗

Correlation of trabecular bone structure with age, bone mineral density, and osteoporotic status: in vivo studies in the distal radius using high resolution magnetic resonance imaging.

High resolution magnetic resonance (MR) images of the distal radius were obtained at 1.5 Tesla in premenopausal normal, postmenopausal normal, and postmenopausal osteoporotic women. The image resolution was 156 microm in plane and 700 microm in the slice direction; the total imaging time was approximately 16 minutes. An intensity-based thresholding technique was used to segment the images into trabecular bone and marrow, respectively. Extensions of standard stereological techniques were used to derive measures of trabecular bone structure from these segmented images. The parameters calculated included apparent measures of trabecular bone volume fraction, trabecular thickness, trabecular spacing, and trabecular number. Fractal-based texture parameters, such as the box-counting dimension, were also derived. Trabecular bone mineral density (BMD) and cortical bone mineral content (BMC) were measured in the distal radius using peripheral quantitative computed tomography (pQCT). In a subset of patients, spinal trabecular BMD was measured using quantitative computed tomography (QCT). Correlations between the indices of trabecular bone structure measured from these high-resolution MR images, age, BMD, and osteoporotic fracture status were examined. Cortical BMC and trabecular BMD at the distal radius, spinal BMD, trabecular bone volume fraction, trabecular thickness, trabecular number, and fractal dimension all decreased with age. Trabecular spacing showed the greatest percentage change and increased with age. In addition, significant differences were evident in spinal BMD, radial trabecular BMD, trabecular bone volume fraction, trabecular spacing, and trabecular number between the postmenopausal nonfracture and the postmenopausal osteoporotic subjects. Trabecular spacing and trabecular number showed moderate correlation with radial trabecular BMD but correlated poorly with radial cortical BMC. High resolution MR imaging, a potentially useful tool for quantifying trabecular structure in vivo, may have applications for understanding and evaluating skeletal changes related to age and osteoporosis.

Adult↗

Use of high-resolution measurements for the retrieval of temperature and gas-concentration profiles from outgoing infrared spectra in the presence of cirrus clouds.

We explore ways in which high-spectral-resolution measurements can aid in the retrieval of atmospheric temperature and gas-concentration profiles from outgoing infrared spectra when optically thin cirrus clouds are present. Simulated outgoing spectra that contain cirrus are fitted with spectra that do not contain cirrus, and the residuals are examined. For those lines with weighting functions that peak near the same altitude as the thin cirrus, unique features are observed in the residuals. These unique features are highly sensitive to the resolution of the instrumental line shape. For thin cirrus these residual features are narrow (< or = 0.1 cm(-1)), so high spectral resolution is required for unambiguous observation. The magnitudes of these unique features are larger than the noise of modern instruments. The sensitivities of these features to cloud height and cloud optical depth are also discussed. Our sensitivity studies show that, when the errors in the estimation of temperature profiles are not large, the dominant contribution to the residuals is the misinterpretation of cirrus. An analysis that focuses on information content is also presented. An understanding of the magnitude of the effect and of its dependence on spectral resolution as well as on spectral region is important for retrieving spacecraft data and for the design of future infrared instruments for forecasting weather and monitoring greenhouse gases.

Journal Article↗

Detection of methane with high spatial resolution with photothermal deflection spectroscopy.

We demonstrate the use of photothermal deflection spectroscopy for detection and measurement of methane with very high spatial resolution. A high spatial resolution may be important for some applications, and other techniques in current use do not provide this resolution. To the best of our knowledge, this is the first application of photothermal spectroscopy to methane detection. We have succeeded in detecting a signal even from a very weak combination-overtone band of methane in the visible region of the spectrum. If used in conjunction with a strongly absorbing fundamental band, the technique is capable of yielding high sensitivity along with very high spatial and temporal resolutions.

Journal Article↗

Resolution considerations in electro-optic, single interface deflectors.

We discuss the maximum theoretical resolution of a single interface, electro-optically controllable beam deflector in domain-engineered LiNbO3 and report on experimental results for implementation of devices optimized either for maximum resolution or for maximum deflection angle. For the resolution optimized device we observed approximately 50 resolvable spots for a +/- 1250-V range, which to our knowledge is a report of one of the highest ratios of resolution per volt from a solid-state electro-optic beam deflector.

Journal Article↗

Passive remote sensing of pollutant clouds by Fourier-transform infrared spectrometry: signal-to-noise ratio as a function of spectral resolution.

In a passive infrared remote sensing measurement, the spectral radiance difference caused by the presence of a pollutant cloud is proportional to the difference between the temperature of the cloud and the brightness temperature of the background (first-order approximation). In many cases, this difference is of the order of a few kelvins. Thus the measured signals are small, and the signal-to-noise ratio (SNR) is one of the most important quantities to be optimized in passive remote sensing. A model for the SNR resulting from passive remote sensing measurements with a Fourier-transform infrared spectrometer is presented. Analytical expressions for the SNR of a single Lorentzian line for the limiting cases of high and low spectral resolutions are derived. For constant measurement time the SNR increases with decreasing spectral resolution, i.e., low spectral resolutions yield the highest SNRs. For a single scan of the interferometer, a spectral resolution that maximizes the SNR exists. The calculated SNRs are in good agreement with the measured SNRs.

Air Pollutants↗

Scalable high-resolution integral videography autostereoscopic display with a seamless multiprojection system.

We propose a scalable high-resolution autostereoscopic display that uses integral videography (IV) and a seamless multiprojection system. IV is an animated extension of integral photography (IP). Although IP and IV are ideal ways to display three-dimensional images, their spatial viewing resolution needs improvement; the pixel pitch of the display and the lens pitch are the main factors affecting IV image quality. We improved the quality by increasing the number and density of the pixels. Using multiple projectors, we create a scalable high-resolution image and project it onto a small screen using long-focal-length projection optics. To generate seamless IV images, we developed an image calibration method for geometric correction and color modulation. We also fabricated a lens array especially for the display device. Experiments were conducted with nine XGA projectors and nine PCs for parallel image rendering and displaying. A total of 2868 x 2150 pixels were displayed on a 241 mm x 181 mm (302.4 dots/in.) rear-projection screen. The lens pitch was 1.016 mm, corresponding to 12 pixels of the projected image. Measurement of the geometric accuracy of the reproduced IV images demonstrated that the spatial resolution of the display system matched that of the theoretical analysis.

Journal Article↗

Effects of luminance and stimulus distance on accommodation and visual resolution.

Measurements of accommodation and visual resolution were obtained at a number of luminance levels and stimulus distances. With reductions in luminance the eye approached a "fixed-focus" condition of accommodation for intermediate distances, resulting in successively larger errors in accommodation for both near and far stimuli. The visual resolution values were initially affected by both the luminance and distance of the stimulus. Subsequent measurements of resolution, following the correction of accommodative errors, were found to be independent of the stimulus distance. The findings are discussed with regard to the problems of "night myopia" and variations in visual resolution with stimulus distance.

Accommodation, Ocular↗

Chromatic two-pulse resolution with and without luminance transients.

Two-pulse discrimination thresholds determined for homochromatic pulses presented as luminance increments or decrements are invariant with wavelength. Wavelength does affect two-pulse temporal resolution if chromatic pulses are presented in hue substitution, matched in luminance (with flicker photometry) to an achromatic background field. For relatively long pulses, the wavelength effect resembles trichromatic saturation discrimination, with poorest temporal resolution at 570 nm. For shorter pulses, temporal resolution for hue substitution stimuli appears related to saturation discrimination under conditions of artificial tritanopia. Under conditions of hue substitution, short-wavelength pulses yield good temporal resolution.

Color↗