Optical images of dose distributions in Gel-Fricke: dosimetric performances of the gel.

The purpose of this work was to examine the dosimetric performances of the radiochromic Fricke-Agarose-Xylenol Orange gel by optical measurements in order to perform dose reconstructions, in view of a future development for 3-D maps. Optical images and dose-response curves of the gel were obtained by a CCD-based device, originally designed for reading radiochromic films, that was modified to meet the optical properties of the dosemeter. With a resolution of 0.18 x 0.18 mm the optimum range of doses in which per cent uncertainty is lower than 2% was 3-10 Gy. The minimum detectable dose, estimated as the absorbed dose corresponding to 3 SD above background, was 0.1 Gy. With a resolution of 1.98 x 1.98 mm the optimum range of doses in which per cent uncertainty is lower than 2% was 0.3-10 Gy. The minimum detectable dose, estimated as the absorbed dose corresponding to 3 SD above background, was 0.015 Gy. The comparison with alanine dosemeters in the dose range 7-10 Gy showed agreement within a few per cent and the same agreement was observed for the comparison with TLD in the range 1-3 Gy.

Dose-Response Relationship, Radiation↗

Tomotherapy.

Tomotherapy is delivery of intensity-modulated, rotational radiation therapy using a fan-beam delivery. The NOMOS (Sewickley, PA) Peacock system is an example of sequential (or serial) tomotherapy that uses a fast-moving, actuator-driven multileaf collimator attached to a conventional C-arm gantry to modulate the beam intensity. In helical tomotherapy, the patient is continuously translated through a ring gantry as the fan beam rotates. The beam delivery geometry is similar to that of helical computed tomography (CT) and requires the use of slip rings to transmit power and data. A ring gantry provides a stable and accurate platform to perform tomographic verification using an unmodulated megavoltage beam. Moreover, megavoltage tomograms have adequate tissue contrast and resolution to provide setup verification. Assuming only translational and rotational offset errors, it is also possible to determine the offsets directly from tomographic projections, avoiding the time-consuming image reconstruction operation. The offsets can be used to modify the leaf delivery pattern to match the beam to the patient's anatomy on each day of a course of treatment. If tomographic representations of the patient are generated, this information can also be used to perform dose reconstruction. In this way, the actual dose distribution delivered can be superimposed onto the tomographic representation of the patient obtained at the time of treatment. The results can be compared with the planned isodose on the planning CT. This comparison may be used as an accurate basis for adaptive radiotherapy whereby the optimized delivery is modified before subsequent fractions. The verification afforded tomotherapy allows more precise conformal therapy. It also enables conformal avoidance radiotherapy, the complement to conformal therapy, for cases in which the tumor volume is ill-defined, but the locations of sensitive structures are adequately determined. A clinical tomotherapy unit is under construction at the University of Wisconsin.

Dose Fractionation, Radiation↗

Estimation of organ dose equivalents from residents of radiation-contaminated buildings with Rando phantom measurements.

Since August 1996, a dose reconstruction model has been conducted with thermoluminescent dosimeter (TLD)-embedded chains, belts and badges for external dose measurements on the residents in radiation-contaminated buildings. The TLD dosimeters, worn on the front of the torso, would not be adequate for dose measurement in cases when the radiation is anisotropic or the incident angles of radiation sources are not directed in the front-to-back direction. The shielding and attenuation by the body would result in the dose equivalent estimation being somewhat skewed. An organ dose estimation method with a Rando phantom under various exposure geometries is proposed. The conversion factors, obtained from the phantom study, may be applicable to organ dose estimations for residents in the contaminated buildings if the incident angles correspond to the phantom simulation results. There is a great demand for developing a mathematical model or Monte Carlo calculation to deal with complicated indoor layout geometry problems involving ionizing radiation. Further research should be directed toward conducting laboratory simulation by investigating the relationship between doses delivered from multiple radiation sources. It is also necessary to collaborate with experimental biological dosimetry, such as chromosome aberration analysis, fluorescence in situ hybridization (FISH) and retrospective ESR-dosimetry with teeth, applied to the residents, so that the organ dose equivalent estimations may be more reliable for radio-epidemiological studies.

Construction Materials↗

Optimisation of recording conditions for the electron paramagnetic resonance signal used in dental enamel dosimetry.

Optimisation of the parameters for recording the electron paramagnetic resonance (EPR) spectra of dental enamel for absorbed dose reconstruction was performed for an EMX (Bruker) spectrometer supplied with a high-sensitivity microwave cavity. Dose determination was performed using a previously developed automatic spectra processing procedure, which uses the non-linear fit of a model spectrum. The experimental error was estimated as the standard deviation of the results from the nominal doses for the set of spectra recorded for 10 samples prepared from teeth of different persons and irradiated in the dose range 0-500 mGy. The microwave power and magnetic field modulation amplitude corresponding to the minimum of dependencies of the error on these parameters were adopted as the optimal ones. For the sets of spectra recorded at optimal parameters for sample masses 100, 50 and 30 mg, the errors of dose determination were obtained as 18, 27 and 37 mGy respectively.

Adult↗

Optimum beam configurations in tomographic intensity modulated radiation therapy.

We review and extend the theory of tomographic dose reconstruction for intensity modulated radiotherapy (IMRT). We derive the basis for a saturation with beam number of dose conformation, and provide an analysis which ranks particular beam orientations in terms of the contribution to the delivered dose. Preferred beam directions are found which effectively reduce the number of beams necessary to achieve a given level of dose conformation. The analysis is a new application of the tomographic projection-slice theorem to the problem of beam orientation determination. The effects of the beam front filter and the positivity constraint arising from the tomographic approach are analysed, and modifications of the beam front filter for small beam numbers are suggested. The theory is applied to simple geometric shapes in two dimensions. A Gaussian ellipse, where analytical results are obtained, and simple hard-edged convex prescribed dose shapes are examined to illustrate beam selection based on the beam overlap metric. More complex concave prescribed dose shapes which contain a sensitive organ are also analysed and for low beam numbers are found to have preferred beam directions.

Gamma Rays↗

First international intercomparison of luminescence techniques using samples from the Techa River Valley.

Bricks collected from a contaminated village (Muslyumovo) of the lower Techa river valley, Southern Urals, Russia, were measured using thermoluminescence and optically stimulated luminescence by four European laboratories and a U.S. laboratory to establish and compare the applied dose reconstruction methodologies. The bricks, collected from 60-100-year-old buildings, had accumulated a relatively high dose due to natural sources of radiation in the brick and from the surrounding environment. This work represents the results of a first international intercomparison of luminescence measurements for bricks from the Southern Urals. The luminescence measurements of absorbed dose in bricks collected from the most shielded locations of the same buildings were used to determine the background dose due to natural sources of radiation and to validate the age of the bricks. The absorbed dose in different bricks measured by four laboratories using thermoluminescence and optically stimulated luminescence at a depth of 10 +/- 2.5 mm from the exposed brick surface agreed within +/-21%. After subtraction of the natural background dose, the absorbed dose in brick due to contaminated river sediments and banks was calculated and found to range between 150 and 200 mGy. The cumulative doses in brick due to man-made sources of radiation at 100 and 130 mm depths in the bricks were also measured and found to be consistent with depth dose profiles calculated by Monte Carlo simulations of photon transport for possible source distributions.

Background Radiation↗

Verification of external exposure assessment for the upper Techa riverside by luminescence measurements and Monte Carlo photon transport modeling.

An area located in the Southern Urals was contaminated in 1949-1956 as a result of radioactive waste releases into the Techa river by the Mayak Production Association. The external dose reconstruction of the Techa river dosimetry system (TRDS-2000) for the exposed population is based on an assessment of dose rates in air (DRA) obtained by modeling transport and deposition of radionuclides along the river for the time before 1952 and by gamma dose rate measurements since 1952. The aim of this paper is to contribute to a verification of the TRDS-2000 external dose assessment. Absorbed doses in bricks from a 130-year-old building in the heavily exposed Metlino settlement were measured by a luminescence technique. By the autumn of 1956 the population of Metlino had been evacuated, and then a water reservoir was created at the village location, which led to a change in the radioactive source geometry. Radiation transport calculations for assumed environmental sources before and since 1957 were performed with the MCNP Monte Carlo code. In combination with TRDS-2000 estimates for annual dose rates in air at the shore of the Techa river for the period 1949-1956 and contemporary dose rate in air measurements, absorbed doses in bricks were calculated. These calculations were performed deterministically with best estimates of the modeling parameters and stochastically by propagating uncertainty distributions through the calculation scheme. Assessed doses in bricks were found to be consistent with measured values within the uncertainty bounds, while their best estimates were approximately 15% lower than the luminescence measurements.

Beta Particles↗

Dental radiography: tooth enamel EPR dose assessment from Rando phantom measurements.

Electron paramagnetic resonance dosimetry of tooth enamel is now established as a suitable method for individual dose reconstruction following radiation accidents. The accuracy of the method is limited by some confounding factors, among which is the dose received due to medical x-ray irradiation. In the present paper the EPR response of tooth enamel to endoral examination was experimentally evaluated using an anthropomorphic phantom. The dose to enamel for a single exposure of a typical dental examination performed with a new x-ray generation unit working at 65 kVp gave rise to a CO2- signal of intensity similar to that induced by a dose of about 2 mGy of 60Co. EPR measurements were performed on the entire tooth with no attempt to separate buccal and lingual components. Also the dose to enamel for an orthopantomography exam was estimated. It was derived from TLD measurements as equivalent to 0.2 mGy of 60Co. In view of application to risk assessment analysis, in the present work the value for the ratio of the reference dose at the phantom surface measured with TLD to the dose at the tooth measured with EPR was determined.

Adult↗

Tooth enamel as a detector material for retrospective EPR dosimetry.

Different methods of spectra evaluation and dose reconstruction in retrospective EPR dosimetry with tooth enamel have been compared in this study. Experiments with teeth irradiated with known doses have shown that dosimetry above 1 Gy using a dose effect curve is, with a standard deviation of 10%, the best method. As a second result it is shown that dosimetry down to 100 mGy with a standard deviation of 15% is possible.

Biometry↗

Radioepidemiology in the aftermath of the nuclear program of the former Soviet Union: unique lessons to be learnt.

The military and civilian nuclear activities in the former Soviet Union led to unique exposures and resulted in high cumulative doses in several populations. In comparison to the atomic bomb survivors, at present the most important cohort in radiation epidemiology, collective and individual doses received by early workers in the plutonium production facilities at Mayak (Chelyabinsk). Techa River residents downstream of Mayak, populations downwind of the Semipalatinsk test site, and subpopulations of Chernobyl victims surpass the Hiroshima/Nagasaki experience in most cases. Even more importantly, the dose rates cover the full range of exposures relevant for radiation protection. i.e., acute to year-long chronic exposures from environmental contamination and bone seeking radionuclides. Parallel to the humanitarian need to mitigate health effects from these exposures, the unique opportunities for research on radiation risks related to low dose rate and chronic radiation have to be explored. Increased efforts by the global radiation research community are needed to address the many questions which cannot be answered by the acutely irradiated survivors of Hiroshima/Nagasaki. Specific attention needs to be drawn to the validation of available exposure and health records and to dose reconstruction which must include dietary sources of exposure. Preliminary intercomparison and validation exercises indicate potentially large sources of error, e.g., due to uncertainties in the reconstruction of early exposures and effects and due to continuing incorporation.

Dose-Response Relationship, Radiation↗

In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation.

As a result of terrorism, accident or war, populations potentially can be exposed to doses of ionising radiation that could cause direct clinical effects within days or weeks. There is a critical need to determine the magnitude of the exposure to individuals so that those with significant risk can have appropriate procedures initiated immediately, while those without a significant probability of acute effects can be reassured and removed from the need for further consideration in the medical/emergency system. It is extremely unlikely that adequate dosemeters will be worn by the potential victims, and it also will be unlikely that prompt and accurate dose reconstruction at the level of individuals will be possible. Therefore, there is a critical need for a method to measure the dose from radiation-induced effects that occur within the individual. In vivo EPR measurements of radiation-induced changes in the enamel of teeth is a method, perhaps the only such method, which can differentiate among doses sufficiently to classify individuals into categories for treatment with sufficient accuracy to facilitate decisions on medical treatment. In its current state, the in vivo EPR dosemeter can provide estimates of absorbed dose of +/- 0.5 Gy in the range from 1 to >10 Gy. The lower limit and the precision are expected to improve, with improvements in the resonator and the algorithm for acquiring and calculating the dose. In its current state of development, the method is already sufficient for decision-making action for individuals with regard to acute effects from exposure to ionising radiation for most applications related to terrorism, accidents or nuclear warfare.

Body Burden↗

Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation.

On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. Here we evaluate the achievable accuracy in using a kV CBCT for dose calculation. Relative electron density as a function of HU was obtained for both planning CT (pCT) and CBCT using a Catphan-600 calibration phantom. The CBCT calibration stability was monitored weekly for 8 consecutive weeks. A clinical treatment planning system was employed for pCT- and CBCT-based dose calculations and subsequent comparisons. Phantom and patient studies were carried out. In the former study, both Catphan-600 and pelvic phantoms were employed to evaluate the dosimetric performance of the full-fan and half-fan scanning modes. To evaluate the dosimetric influence of motion artefacts commonly seen in CBCT images, the Catphan-600 phantom was scanned with and without cyclic motion using the pCT and CBCT scanners. The doses computed based on the four sets of CT images (pCT and CBCT with/without motion) were compared quantitatively. The patient studies included a lung case and three prostate cases. The lung case was employed to further assess the adverse effect of intra-scan organ motion. Unlike the phantom study, the pCT of a patient is generally acquired at the time of simulation and the anatomy may be different from that of CBCT acquired at the time of treatment delivery because of organ deformation. To tackle the problem, we introduced a set of modified CBCT images (mCBCT) for each patient, which possesses the geometric information of the CBCT but the electronic density distribution mapped from the pCT with the help of a BSpline deformable image registration software. In the patient study, the dose computed with the mCBCT was used as a surrogate of the 'ground truth'. We found that the CBCT electron density calibration curve differs moderately from that of pCT. No significant fluctuation was observed in the calibration over the period of 8 weeks. For the static phantom, the doses computed based on pCT and CBCT agreed to within 1%. A notable difference in CBCT- and pCT-based dose distributions was found for the motion phantom due to the motion artefacts which appeared in the CBCT images (the maximum discrepancy was found to be approximately 3.0% in the high dose region). The motion artefacts-induced dosimetric inaccuracy was also observed in the lung patient study. For the prostate cases, the mCBCT- and CBCT-based dose calculations yielded very close results (<2%). Coupled with the phantom data, it is concluded that the CBCT can be employed directly for dose calculation for a disease site such as the prostate, where there is little motion artefact. In the prostate case study, we also noted a large discrepancy between the original treatment plan and the CBCT (or mCBCT)-based calculation, suggesting the importance of inter-fractional organ movement and the need for adaptive therapy to compensate for the anatomical changes in the future.

Biophysical Phenomena↗

Measurement of 129 I and 137 Cs in soils from Belarus and reconstruction of 131I deposition from the Chernobyl accident.

I and Cs have been measured in a large number of soil samples collected throughout the country of Belarus to support efforts for thyroid-dose reconstruction following the Chernobyl accident. Samples of soil consisting of multiple 30-cm-deep cores per site were sampled following a selection process to ensure sites were undisturbed and representative. Samples were measured by accelerator mass spectrometry (AMS) for I, gamma spectrometry for Cs, and gas chromatography (GC) for total iodine. Results show that both I and Cs are retained firmly in the top approximately 15 to 20 cm of the soil. Our results also suggest that the correlation between I and Cs deposition across the country of Belarus is poor; hence, I is a better surrogate for I than is Cs. It was also noted that total iodine concentrations in topsoil from Belarus are low compared with other regions of the world where radiogenic thyroid cancer has been studied.

Cesium Radioisotopes↗

Low-dose electron image reconstruction of negatively stained contractile phage sheath from Bacillus subtilis (PBS-Z).

The structure of the contractile sheath of the defective phage from B. subtilis (PBS-Z) has been investigated by low-dose electron microscopy and image reconstruction. The extended and contracted sheath particles were imaged by means of two negative stains which consisted of uranyl- and phosphotungstate-containing solutions of a pH of 4.2 and 7.0 respectively. Images of identical parts of the same type of specimen were recorded at a total electron dose of 80 C/m2 (5 electrons/A2) and 4 x 10(3) C/m2 (250 electrons/A2). The low-dose reconstructions of the extended and contracted sheath structure in the two stains show good correspondence and made it possible to draw the following structural conclusions. The sheath protein in both types of structure has an elongated shape, and in both structures the long molecular axis lies in a plane perpendicular to the helical sheath axis. The orientation of the protein in the extended and contracted sheath is different; the long axes differ by about 35 degrees in orientation. The reconstructions did not permit conclusions about different conformational states of the protein in both structures. These data, together with the packing parameters of the protein subunits in the contractile sheath [1], form the complete structural analysis of this biological structure by electron microscopy. The radiation damage effects which have been monitored in analyzing image pairs to the full extent may be summarized as follows. (1) Diameters of the sheath structure increase, which indicate flattening. (2) There is no loss in resolution, and layerline altitudes of the Fourier-transformed images do not change. (3) Uranyl stain behaves differently compared to phosphotungstate. In both negative stains the structural noise level increases upon irradiation as follows from the increase in phase residuals of the digital layerline data. In uranyl-stained images also more aperiodic noise appears. (4) The Fourier amplitudes of the principal layerline maxima shift towards lower spatial frequencies; phases of corresponding maxima generally remain constant. This pattern is more pronounced in the extended sheath data; there is no rationale describing these positional shifts. Moreover, in the case of contracted sheath the amplitudes of Fourier components also change more in absolute value. Therefore the damage effects also seem to depend on the type of structure embedded in the stain. (5) In the reconstructed images these radiation effects create artificial stain-excluded volumes of a type and at a radius which depend on the stain and structure.

Bacillus subtilis↗

Good fish/bad fish: a composite benefit-risk by dose curve.

Balancing risks and benefits of fish consumption is now a high visibility public health topic. Many studies identify health benefits of eating fish, both for prenatal development and adult cardiovascular conditions, partly attributed to omega-3 (n-3) polyunsaturated fatty acids or PUFAs). Many reports raise concerns about methylmercury and polychlorinated biphenyl effects on the developing fetal brain (although adults, too, can manifest methylmercury effects). Most reports and advisories focus on recreational or subsistence fish, but the vast majority of people obtain most or all of their fish from commercial sources. Our analysis of the nine most common fish in New Jersey markets, yielded a weighted average methylmercury concentration of 0.23 ug/g (ppm wet weight). There are great disparities in the amount and distribution of both PUFAs and contaminants) in different fish species. Recognizing that both benefits and harm must be related to dose, we propose a compound dose-response curve, currently based on limited data, to identify a zone of benefit, above the benefit threshold and below the harm threshold. The duration of pregnancy and birth weight improve at a benefit threshold of about 8-15 g/day maternal fish intake. Meta-analyses reveal adult cardiovascular benefits around 7.5-22.5 g/day bracket (assuming an 8 ounce/227 g typical meal), yielding a midpoint also at 15 g/day, but this is an artifact of the intake stratification. Benefit asymptotes are harder to extract, but are above 45 g/day, and in some studies exceed 100g/day. Using the EPA Reference Dose of 0.1 ug/kg day as a methylmercury threshold, The fish intake threshold for harm converts to 27 g/day (for a selection of common commercial fish averaging 0.23 ppm MeHg) to 65 g/day for someone choosing fish low in MeHg (0.1 ppm). However, these are worst case thresholds since the RfD includes uncertainty factors. Some people eat much more than 65 g/day. The shape of the dose-benefit and dose-harm curves require better data for estimating thresholds and asymptotes, which will impact the composite curve. We propose this approach clarifies the kinds of data needed to improve risk communication on "what should I eat". Benefits from fish consumption are confounded by socioeconomic class and/or by the avoidance of more harmful foods that fish replaces, which may be as important a benefit mechanism as the PUFA content. Additional studies with better dose-reconstruction are needed and large scale intervention studies are desirable.

Animals↗

Biological dosimetry of beta-ray exposure from tritium using chromosome translocations in human lymphocytes analyzed by fluorescence in situ hybridization.

Radiation exposures from tritium make up a substantial fraction of the occupational and accidental radiation exposures associated with the nuclear power industry. Tritiated water, the most abundant form of tritium, is of particular interest because it is readily taken up by human cells and its irradiation of the cells is spread over a period of days. To approximate the prolonged exposure and the conditions that the cells of an individual would experience in vivo, we irradiated human lymphocytes with tritiated water for 48 h in a 1:1 blood:medium mix. For estimation of the tritium beta-ray dose, a cellular water content of 0.78, based on measurements of human lymphoblastoid cells in culture medium, was used. A modified dose calculation formula was developed for the radiation exposure conditions. A total of 48,014 metaphases (14,482 in irradiated samples and 33,532 in control, unirradiated samples) in human lymphocytes cultured for 72 h after exposure were analyzed for chromosome translocations using fluorescence in situ hybridization. The linear slope (alpha coefficient) of the dose-response curve was measured to be (3.93+/-0.42) x 10(-2) and (5.26+/-0.48) x 10(-2) translocations per cell per gray for complete translocations (tc) and complete translocations plus incomplete translocations [ti(Ab)], respectively, when the data were fitted to a linear model using a weighted least-squares method. The alpha coefficient for tc is significantly lower than that for conventionally measured dicentrics after tritium beta irradiation, but the alpha coefficient for tc + ti(Ab) does not differ significantly from that for dicentrics. This is in agreement with theoretical considerations. The importance of scoring criteria is stressed. The frequency of tc + ti(Ab) is proposed to be a reliable biodosimeter for tritium exposures, and its practical use in a dose reconstruction is presented.

Beta Particles↗

Retrospective study of the iodine-131 contamination of workers in the radiopharmaceutical industry.

A dose reconstruction study was performed for personnel occupationally exposed to 131I in radiopharmaceutical production, during the years 1981 to 1994, with the objective of estimating committed effective doses and critically reviewing the main causes of their exposures. The workers were selected from a group responsible for the production, labelling and distribution of all radiopharmaceutical material in Brazil. Best estimates of intakes and doses were derived from the examination of the individual monitoring records and the reports from the radiation protection supervisor, complemented by interviews with the workers and with radiation protection officers. Over this time period workers had chronic as well as acute intakes of 131I. Committed effective doses were found to be dependent on the task performed by the worker and the site of operation and inversely correlated with the amounts of iodine handled. Intakes in general were a consequence of inadequate radiation protection control.

Humans↗

Cytogenetic research after accidental radiation exposure.

Currently, chromosome aberration analysis in peripheral lymphocytes is the most sensitive method to estimate individual doses in accidental radiation exposures. The assessment of dose is particularly reliable in cases with acute, uniform, whole-body exposure or after irradiation of large parts of the body. However, the scenarios of most radiation accidents largely result in partial-body exposures or a non-uniform dose distribution. This complicates dose estimation especially in cases with protracted or fractionated exposures. Problems exist also for the dose reconstruction of radiation exposures occurring a long time before sampling. To overcome these problems, the Qdr method or the "contaminated Poisson" method can be used to determine meaningful dose estimates from data based on conventional scoring of dicentrics. Scoring of so-called stable translocations by the newly developed technique of chromosome painting should be particularly useful for estimating doses of past exposures or of dose accumulation. After incorporation of radionuclides with largely localized depositions in certain organs or tissues, realistic individual dose estimates cannot be achieved. Exemplified by incidents involving larger groups of the population such as in Chernobyl and Goiania and by single cases with serious overexposures, chromosome dosimetry is evaluated in the present article.

Brazil↗