PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Feasibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Pulsed dose rate brachytherapy in head and neck cancers. Feasibility study of a French cooperative group.

PURPOSE: To prospectively evaluate the feasibility of pulsed dose rate (PDR) brachytherapy to mimic the continuous low dose rate (cLDR) iridium wire technique in head and neck carcinomas. MATERIALS AND METHODS: A series of 30 patients were included from June 1995 to May 1998. The primaries were located in the oral cavity (four T1, seven T2 and two T3), the velotonsillar arch (eight T1 and eight T2) and the posterior wall (one T3). Thirteen were irradiated by exclusive brachytherapy (dose, > or =45 Gy). The PDR delivered 0.5 Gy/pulse, one pulse/h, day and night, to mimic cLDR irradiation. RESULTS: The implantation was feasible for all the patients, usually easy and of good quality. The mean duration/pulse was 13 min, with a mean source activity of 171 mCi. Patient tolerance was poor in nine cases. Sixteen patients could receive the whole PDR treatment with a total ranging from 30 to 120 pulses without any problem. Seven had short breakdowns (< or =6 h). Seven had definitive breakdowns, but could end the irradiation by manual afterloading of iridium 192 wires. The radioprotection was better (or complete), except for one patient. Most of the breakdowns were related to kinking or flattering of the tube. CONCLUSIONS: PDR is feasible in head and neck carcinomas, but necessitates improvement of the quality and control of the plastic tubes.

Brachytherapy↗

Feasibility of keying data from screen-displayed facsimile images in an ongoing trial: the collaborative ocular melanoma study.

As part of an ongoing clinical trial, we conducted an experiment to assess the feasibility and to determine the reliability of data entry from a computer screen display of images of data collection forms transmitted by facsimile (fax) machines directly into a computer for paper forms designed without consideration of fax or image display requirements. Feasibility was assessed on the basis of accuracy and reliability of data entry and on operator satisfaction. During a 2-week period, half of the forms received at the Collaborative Ocular Melanoma Study (COMS) coordinating center were key-entered twice, using the paper forms as the source (paper source entry). The remaining forms were entered once using paper source and were later reentered using the screen display of images of the faxed forms as the source (image source entry). The latter group of forms, or 50% of all forms received, were entered a third time, using the image source entry. Two data entry operators participated in the experiment. Discrepancy rates between and within data entry operators were calculated for both modes of entry. A total of 50,861 keystrokes (28,095 items) across 1122 records were checked for consistency. The overall discrepancy rate associated with double paper source entry was approximately 21 per 10,000 keystrokes (20 per 10,000 items). Discrepancy rates associated with paper source versus image source entry (53 per 10,000 keystrokes [57 per 10,000 items]) and double image source entry (57 per 10,000 keystrokes [47 per 10,000 items]) were similar in magnitude. Image source entry of forms received by facsimile may provide an acceptable alternative to paper entry in ongoing multicenter clinical trials where the costs of converting existing forms and systems to automated data capture may be unacceptable. This experiment confirmed the feasibility of such an alternative and suggested that improved screen displays and changes in equipment to facilitate entry of data from the screen display may enhance accuracy of entries.

Choroid Neoplasms↗

[Health reform and its political component: a feasibility analysis].

The political dimension of the health reform is a fundamental aspect that not only influences the project's feasibility, but also its form and content. Therefore the study of the political aspects involved in the health reform process is essential to determine the political feasibility of the reform. Based on the case studies of Colombia and Mexico, this study concentrates on the State's capability to promote health reform projects successfully. It specifically focuses on those elements that seek to improve the political feasibility of formulating, legislating and implementing reform proposals. The relevant variables under study are: the institutional context in which the reform initiatives develop; the political dynamic of the reform process; and the characteristics and strategies of the teams in charge of leading the reforms (change teams). The similarities in the political strategies used by the teams in charge of the health reform, and those of similar technocratic teams in charge of economic reform, stand out as one the study's main findings. It is argued that, although these strategies were effective in bringing about the creation of new actors in the health sector such as private organizations for the financing and provision of health services, they did not have the same impact on the transformation of the old actors the health ministries and the social security institutes, therefore considerably limiting the scope of the reforms.

Colombia↗

[Reporting new HIV cases in Catalonia, Spain: is technical consensus feasible?].

OBJECTIVE: To describe the process performed in Catalonia (Spain) to design an information system for monitoring new cases of HIV infection. METHODS: A survey was used to evaluate perception of the need for notification of HIV infection by health care professionals (n = 106), as well as their opinions of the various possibilities for the implementation of the notification system. As a result of this evaluation, a specific technical report defining the objectives and technical characteristics of the new notification system was produced. The feasibility of the system in health centres was evaluated through discussions with health care professionals, health authorities and Non-Governmental Organizations, and a second survey was designed to evaluate the use of a personal identification code (PIC) from the individual health card (IHC). This process took plabe between 1998 and 2000. RESULTS: A total of 84.5% of the health care professionals believed that HIV notification should be mandatory and confidential; 90.4%, were of the opinion that notification would enable identification of the epidemiological characteristics of infected individualos, and 75% believed that these individuals would have to be identified by name. Finally, 66% of the health care professionals believed that the use of the PIC from the IHC would be feasible as the personal identifier in HIV notification. A final proposal was draw up and 1 January, 2001 was set as the date to initiate the pilot phase of the new HIV notification system. CONCLUSIONS: Most of the health care professionals surveyed expressed the need for notification of HIV infection, and for such notification to receive institutional endorsement. They also believed that, as with other diseases of individualized mandatory reporting, notification should be carried out with a single personal identifier. The information obtained from notification of HIV infection is essential for the optimal planning of preventive programs and the provision of health services. The main difficulties observed were that HIV infection has not been included among the diseases of mandatory reporting, as well as the low implantation of the PIC in the hospitals' clinical registries. All the sectors involved have an important role to play in creating the conditions necessary for the notification system of new cases of HIV infection to be feasible and useful.

Consensus↗

Time to onset of regional relaxation: feasibility, variability and utility of a novel index of regional myocardial function by strain rate imaging.

OBJECTIVES: Time to onset of regional relaxation (T(R)) has been proposed as a novel index of regional myocardial function. This study sought to prospectively establish the feasibility and variability of T(R) in healthy volunteers (CONTROL) and to examine its utility in patients with inducible ischemia (PATIENT). BACKGROUND: Strain rate imaging (SRI) depicts myocardial deformation and enables quantitation of regional myocardial function with high temporal and spatial resolution. Thus, regional mechanical events can be accurately timed with SRI. The time point of regional transition from contraction to relaxation is altered in pathologic states. METHODS: Resting mean segmental T(R) was determined in 60 subjects: 20 in the CONTROL group and 40 in the PATIENT group. T(R) was also measured at peak dobutamine stress in the PATIENT group. An automated image analysis program determined the time point of transition from regional contraction to relaxation activity, and calculated T(R), defined as the time, in milliseconds, from the electrocardiogram R-wave to this transition point. RESULTS: Automated T(R) measurements were feasible in more than 90% of the segments in CONTROL and PATIENT groups. Mean T(R) was 353 +/- 24 ms and was shorter in the mid segments compared to apical and basal segments. Intra- and interobserver variability were low (6% and 9%, respectively). In the PATIENT group, the percent decrease in T(R) during dobutamine stress was significantly higher in normal compared to ischemic segments (30% vs. 19%, respectively, p = 0.01). A percent change >20% in T(R) identified patients with an ischemic response during dobutamine infusion (sensitivity 92%, specificity 75%). CONCLUSIONS: T(R), a novel quantitative index of regional myocardial function, can be determined with low variability and satisfactory feasibility in routine clinical settings. Percent change in T(R) identifies ischemic segments during dobutamine stress echocardiography (DSE) and may allow quantitative assessment of DSE.

Adult↗

Feasibility and efficacy of balloon-based neuroprotection during carotid artery stenting in a single-center setting.

We sought to prospectively assess the feasibility and in-hospital efficacy of the PercuSurge GuardWire temporary balloon-occlusive system for neuroprotection during carotid angioplasty and stenting (CAS).Carotid angioplasty and stenting harbors a risk of distal embolization. Cerebral protection devices are currently under clinical investigation.Ninety-six consecutive patients with carotid bifurcation disease underwent a total of 102 CAS procedures with the intention to use the GuardWire for neuroprotection. GuardWire deployment was achieved in 99 procedures performed in 93 patients (97%). Device failure (n = 3) and severe neurologic responses to balloon occlusion of the targeted carotid artery (n = 2) accounted for five additional procedures that were essentially concluded without neuroprotection, for a total of 94 procedures completed as intended in 88 patients (92% procedural feasibility rate). Carotid angioplasty and stenting was performed successfully in 94 patients (100 procedures). There were no in-hospital deaths; but three patients (3.1%) sustained strokes, and two patients experienced transient ischemic attacks, for a total periprocedural complication rate of 5.2%. One major stroke occurred with the GuardWire in place, whereas two minor strokes were observed in patients in whom the device could not be deployed. Thus, successful neuroprotected CAS without major neurologic events was achieved in 87 patients (91%). The GuardWire temporary balloon-occlusive system is feasible as an adjunct to CAS in the majority of patients. It is associated with a 3.1% rate of major periprocedural neurologic complications. Adverse neurologic reactions to balloon occlusion may prohibit effective use of the system in about 2% of patients.

Aged↗

Feasibility of atrial fibrillation detection and use of a preceding synchronization interval as a criterion for shock delivery in humans with atrial fibrillation.

OBJECTIVES: This study assessed the feasibility of detecting atrial fibrillation (AF) and delivery of appropriately timed R wave shocks using an implantable atrial defibrillator. BACKGROUND: For atrial defibrillation therapy to be feasible in an implantable form, AF must be detected in a specific fashion, and the risk of ventricular proarrhythmia should be minimized. METHODS: Eleven patients with AF underwent testing with an implantable atrial defibrillator (METRIX 3000 Automatic Atrial Defibrillator, InControl, Inc.). Wideband electrograms (EGMs) were recorded from the right ventricular (RV) bipolar catheter and from the multipolar catheters located in the right atrium (RA) and coronary sinus (CS). Atrial fibrillation detection was performed using two serial algorithms-quiet interval analysis and baseline crossing analysis-that detect atrial activity on the RA-CS channel. Ventricular sensing using a minimal preceding synchronization interval of 500 ms as a criterion for synchronous shock delivery was performed from filtered RV and RV-CS EGMs. RESULTS: The AF detection algorithms were applied to 53 AF data segments and 18 normal sinus rhythm data segments. Atrial fibrillation was detected appropriately in 49 instances, and the specificity for detecting AF and normal sinus rhythm was 100%. Synchronization criterion efficacy was assessed by delivering shock markers and shocks. Of the 2,025 R waves processed, 557 (27.5%) were marked as suitable for shock delivery. In addition, 69 therapeutic and 11 test shocks were delivered during AF. All shock markers and shocks were delivered synchronously with the R wave, and the synchronization criterion was never violated. CONCLUSIONS: Atrial fibrillation can be detected in a specific fashion using the RA-CS lead configuration and serial detection algorithms for atrial sensing. The delivery of properly timed shocks is feasible and should minimize the risk of ventricular proarrhythmia.

Adult↗

Development and feasibility of a modified reattribution model for somatising patients, applied by their own general practitioners.

Reattribution has been developed as a cognitive-behavioural treatment model for somatisation in general practice. Our objective is to make reattribution suitable for application on patients with long-standing somatisation, including hypochondria, and to evaluate feasibility. Three modifications were developed: (1) dealing with persistent illness worry, (2) adjustment of the doctor's speed to that of the patient, and (3) the use of symptom diaries. Performance of ten experienced general practitioners (GPs), after a 20h training programme (six sessions of variable length), was measured by self-registrations and audio-taped consultations. GPs were interviewed on factors interfering with performance. Nine GPs completed the course. Reattribution was applied to 51 out of 75 indicated somatising patients, which required on average three consultations of 10-30min duration. We conclude that the modified reattribution model offers a feasible approach to the broad spectrum of somatisation seen in general practice; only the modification 'dealing with illness worry' showed limited feasibility.

Adult↗

Development and feasibility of a nurse administered strategy on depression in community-dwelling patients with a chronic physical disease.

This contribution reports on the acceptability and feasibility to nurses and patients of an intervention to ameliorate minor depression among patients with chronic physical diseases. Elderly patients with chronic obstructive pulmonary disease (COPD) and type II Diabetes Mellitus were recruited from 10 general practices. All eligible patients were screened. Twenty-nine patients with minor depression gave their informed consent to participate in this feasibility study. The nurses spent an average of 70 min per visit. Our intervention appeared feasible and acceptable to patients and nurses. For the nurses, it provided an additional tool for a well-known problem. The majority of the patients regarded the intervention as worthwhile and effective. Patients had difficulties in understanding the link between physical complaints and symptoms of depression. The intervention has been further improved on the basis of our experiences, and is now ready to be tested in an effectiveness study.

Aged↗

Safety and feasibility of dobutamine-atropine stress echocardiography in patients with ischemic left ventricular dysfunction.

The aim of this study was to analyze whether left ventricular dysfunction affects the safety and feasibility of high-dose dobutamine-atropine stress echocardiography. We examined the results of the test in 318 consecutive patients who were referred for high-dose dobutamine-atropine stress echocardiography and also underwent diagnostic cardiac catheterization. Forty-four patients had a left ventricular ejection fraction of 25% or less (mean, 21%; range, 15% to 25%). In the entire group of 318 patients, no serious complications (death, myocardial infarction, or ventricular fibrillation) occurred. The overall feasibility of completing the test was excellent (97%). A trial fibrillation occurred in four patients, nonsustained ventricular tachycardia in 12, and sustained ventricular tachycardia in one. A decrease in systolic blood pressure of greater than 40 mm Hg or a peak systolic pressure of less than 80 mm Hg was present in eight cases. In the group with an ejection fraction of 25% or less, there was a higher rate of significant tachyarrhythmias (14% versus 5%; p = 0.03), whereas the feasibility of the test was slightly lower (89%; p < 0.01), but no difference for hypotension was found. By multivariate analysis, a history of tachyarrhythmias was the only predictor of stress-induced arrhythmias. Advanced left ventricular dysfunction does not represent a contraindication for dobutamine-atropine stress testing.

Adrenergic beta-Agonists↗

Feasibility of spirometry and reversibility testing for the identification of patients with chronic obstructive pulmonary disease on asthma registers in general practice.

There is renewed interest in the diagnosis of chronic obstructive pulmonary disease (COPD) within primary care. Primary care physicians have difficulty distinguishing asthma from COPD. We tested the feasibility of using spirometry and if appropriate, reversibility testing, to identify patients with COPD on asthma registers in primary care. We carried out a cross-sectional study in three inner-city group practices in east London. Three hundred and twenty-eight patients aged 50 years and over on practice asthma registers were invited to attend for spirometry and, if appropriate, a trial of oral corticosteroids. The main outcome measures were: feasibility of carrying out spirometry; lung function; severity of COPD; prior diagnosis of COPD; response to a corticosteroid trial; quality of life. One hundred and sixty-eight of 328 (51%) patients attended for spirometry. According to British Thoracic Society criteria, 58 (34%) patients had normal spirometry at the time of assessment; 40 (24%) had active asthma and 57 (34%) had COPD. Thirteen patients (8%) were unable to perform spirometry. Of 57 patients with COPD 30 (53%) had mild, 15 (26%) had moderate and 12 (21%) had severe disease. Twenty-three of 57 (40%) patients with COPD on spirometry had this diagnosis recorded prior to the study. New diagnoses of COPD were more likely in those with mild or moderate disease (P<0.05). Twenty-three of 57 (40%) patients with COPD completed a corticosteroid trial: one showed significant reversibility of lung function. Spirometry was feasible and helped identify patients with COPD on asthma registers in these inner-city practices. Patients aged 50 years and over on asthma registers had a wide spectrum of lung function with considerable diagnostic misclassification. Some patients with normal lung function when tested may have had well controlled asthma. New diagnoses of COPD were mainly in those with mild or moderate disease.

Aged↗

Creation of a transrenal arteriovenous dialysis shunt: feasibility study in a swine model.

PURPOSE: To investigate the feasibility of percutaneous renal artery and vein access for the creation of a transrenal arteriovenous hemodialysis graft. MATERIALS AND METHODS: Renal-artery-to-ipsilateral-renal-vein conduits were constructed with use of entirely percutaneous techniques in seven swine. Renal artery and vein access was performed in six animals with use of a retrograde (inside-out) technique and in one animal with use of an antegrade (outside-in) technique. Modified 8-F sheaths were used in the first three animals and Wallgrafts were used in the final four animals to form the arterial and venous limbs of each shunt. The arterial and venous limbs were joined together by a subcutaneous segment of 6-mm reinforced polytetrafluoroethylene (PTFE) in five animals and by external conduits in two animals. Wallgrafts were deployed from the renal artery and vein into the segments of PTFE. The free ends of each conduit were tunneled and joined together to close the arteriovenous circuit. Post-shunt angiography was used in all animals to document successful shunt creation and demonstrate rapid arteriovenous shunting as a determinant of technical feasibility. Two of the seven animals received additional anticoagulation therapy and/or antiplatelet therapy to prevent shunt thrombosis during the follow-up period. The three initial animals were killed within 2 hours of shunt creation, and two of the remaining four animals returned for angiographic follow-up, one on day 2 and one on day 9. All animals underwent a complete necropsy to assess for potential complications including hemorrhage and vascular or bowel injury. RESULTS: Retrograde renal arterial and venous access was successful in all six animals in which it was attempted. Five of six arterial accesses and four of six venous accesses traversed the peritoneum with two arterial accesses and one venous access penetrating a loop of large bowel. Antegrade access was performed and successfully accomplished in the final animal. Brisk arteriovenous shunting was demonstrated on completion angiography in all animals. Graft occlusion was present in the two animals that returned for follow-up and two animals died before follow-up as a result of graft leakage and subsequent hemorrhage. Minimal perinephric and intrarenal hemorrhage was demonstrated at necropsy after shunt insertion in the remaining five animals. Renal infarction was present in all kidneys used for transrenal access. CONCLUSION: The transrenal approach for the creation of a percutaneous arteriovenous shunt is feasible after renal artery and vein access by either the retrograde or antegrade technique. Additional technical refinements of the procedure and the devices used will be necessary before follow-up studies are conducted.

Animals↗

Intravascular radiation therapy after balloon angioplasty of narrowed femoropopliteal arteries to prevent restenosis: results of the PARIS feasibility clinical trial.

PURPOSE: To conduct a feasibility study to assess the feasibility, safety, and outcome of endoluminal gamma radiation therapy after balloon angioplasty of superficial femoral artery (SFA) lesions. MATERIALS AND METHODS: Forty patients with claudication were enrolled in the study and underwent percutaneous transluminal angioplasty (PTA) of SFA lesions with a mean lesion length of 9.8 cm +/- 3.0 and a mean reference vessel diameter of 5.2 mm +/- 3.1. After successful PTA, a segmented centering balloon catheter was positioned to cover the PTA site. The patients were then transported to the radiation oncology suite and treated with a microSelectron HDR afterloader with use of an Ir-192 source with a prescribed dose of 14 Gy, 2 mm into the vessel wall. Ankle-brachial index (ABI) and Rutherford score were evaluated at 1, 6, and 12 months after the procedure and angiographic follow-up was conducted at 6 months. RESULTS: Radiation was delivered successfully to 35 of 40 patients. There were no procedural complications. Exercise and rest ABI were higher at 1 year (0.72 +/- 0.26 and 0.89 +/- 0.18, respectively) compared to baseline (0.51 +/- 0.25 and 0.67 +/- 0.17, respectively). Maximum walking time on a treadmill increased from 3.41 min +/- 2.41 to 4.43 min +/- 2.49 at 30 days and was 4.04 min +/- 2.8 at 12 months. The angiographic binary restenosis rate at 6 months was 17.2% and the clinical restenosis rate at 12 months was 13.3%. There were no angiographic or clinical adverse events related to the radiation therapy. CONCLUSIONS: Intraarterial radiation after PTA of SFA lesions with use of high-dose rate gamma radiation is feasible and safe. The angiographic and clinical improvements are sustainable at 1 year and represent a potent antirestenotic therapy for the treatment of narrowed peripheral arteries.

Adult↗

Percutaneous transthoracic duct catheterization to the neck and esophagus: a feasibility study.

PURPOSE: To assess the feasibility of inserting a drain catheter percutaneously from the cisterna chyli (CC) through the thoracic duct (TD) wall to the neck or esophagus for potential long-term T-cell sampling or drainage in acute or short-term experiments. MATERIALS AND METHODS: Percutaneous transabdominal catheterization of the TD from the CC was performed in four animals to insert a 65-cm, 21-gauge needle over a microguidewire. In two dogs, the distal TD was perforated into the neck to connect the TD drain to an access port. In acute experiments on two swine, the esophagus was accessed by puncturing an intraluminal Foley-catheter balloon through the mid TD wall. In one animal, the TD catheter tip was left to drain in the distal esophagus; in the other animal, the catheter distal tip was pulled back through a gastrostomy until the proximal end had retracted into the proximal TD. RESULTS: TD-to-neck port connection was well tolerated short-term. One dog developed dehiscence over the port at 10 days necessitating its removal; in the other dog, the whole drain retracted into the neck from the proximal TD. The technique for TD-to-esophagus catheterization in swine was feasible with no acute complications or mediastinal leakage of contrast medium. CONCLUSIONS: Transabdominal percutaneous inside-out TD puncture for drainage to a neck port or to the esophagus is feasible in dogs and swine, respectively.

Animals↗

Feasibility and accuracy of transthoracic Doppler echocardiographic estimation of pulmonary capillary wedge pressure applying different methods.

BACKGROUND: Pulmonary wedge pressure (PWP) is an established index of cardiac function and an essential component in the management of patients with congestive heart failure and in critically ill patients. AIM: To evaluate feasibility and accuracy of non-invasive prediction of PWP by Doppler echocardiography in daily clinical practice. METHODS: Agreement was assessed between values predicted by Doppler vs. invasively measured PWP. Forty-five consecutive patients [mean (S.D.) age 62 (10) years] with CAD (44%), DCMP (40%) and without structural heart disease (16%) were studied (EF< or =40% in 58% of the patients). Doppler transmitral and pulmonary venous flow velocity profiles were recorded. For binary and quantitative prediction of PWP, four different methods and five different linear equations, suggested previously in the literature, were evaluated. RESULTS: Predictive values to identify elevated PWP were highest for pulmonary venous flow reversal exceeding the duration of forward mitral flow during atrial systole (PPV 1 and NPV 0.96). Likewise, agreement with measured PWP was highest for equations comprising both transmitral and pulmonary venous flow variables (relative mean difference 0.11, S.D.+/-4.01 mmHg for the most accurate equation). Feasibility was slightly, but not statistically, lower when pulmonary venous flow was considered vs. transmitral flow parameters alone for binary prediction (87 vs. 93%) as well as for quantitative assessment (82 vs. 93%). CONCLUSION: Semiquantitative prediction of elevated PWP by Doppler echocardiography is feasible as well as accurate in daily clinical practice. However, accuracy of numeric estimates is limited. Hence, invasive measurement of PWP is still necessary in certain clinical settings.

Adult↗

Feasibility of closed-loop titration of propofol guided by the Bispectral Index for general anaesthesia induction: a prospective randomized study.

BACKGROUND: This study was designed to evaluate the feasibility of propofol infusion by a closed-loop system for the titration of anaesthetic induction guided by Bispectral Index. METHODS: Forty patients were prospectively and randomly allocated into two groups: the target control infusion (TCI) group, where propofol titration was performed manually guided by the Bispectral Index using a commercial pharmacokinetic model (Diprifusor device) and the closed-loop group where titration was performed using a proportional differential algorithm. For both groups, the objective was to achieve a Bispectral Index of 50. Remifentanil TCI was infused at a target of 2 ng mL-1 and was maintained constant throughout the study. Feasibility of automatic induction was evaluated with performance error and haemodynamic data. RESULTS: Bispectral Index overshoot (-9 +/- 13% vs. -16 +/- 20%, P = 0.035) and mean duration of induction (381 +/- 106 s vs. 490 +/- 131 s, P = 0.004) were lower in the closed-loop group than in the TCI group. Haemodynamic data were similar between groups with a similar use of ephedrine bolus. CONCLUSION: The system was able to allow induction clinically for all patients. Automated titration guided by Bispectral Index for propofol infusion was feasible without increase in haemodynamic adverse effects.

Algorithms↗

A feasibility study evaluating docetaxel-based sequential and combination regimens in the adjuvant therapy of node-positive breast cancer.

BACKGROUND AND PURPOSE: Docetaxel is an active agent in the treatment of metastatic breast cancer. We evaluated the feasibility of docetaxel-based sequential and combination regimens as adjuvant therapies for patients with node-positive breast cancer. PATIENTS AND METHODS: Three consecutive groups of patients with node-positive breast cancer or locally-advanced disease, aged < or = 70 years, received one of the following regimens: a) sequential A-->T-->CMF: doxorubicin 75 mg/m2 q 3 weeks x 3, followed by docetaxel 100 mg/m2 q 3 weeks x 3, followed by i.v. CMF days 1 + 8 q 4 weeks x 3; b) sequential accelerated A-->T-->CMF: A and T were administered at the same doses q 2 weeks; c) combination therapy: doxorubicin 50 mg/m2 + docetaxel 75 mg/m2 q 3 weeks x 4, followed by CMF x 4. When indicated, radiotherapy was administered during or after CMF, and tamoxifen started after the end of CMF. RESULTS: Seventy-nine patients have been treated. Median age was 48 years. A 30% rate of early treatment discontinuation was observed in patients receiving the sequential accelerated therapy (23% during A-->T), due principally to severe skin toxicity. Median relative dose-intensity was 100% in the three treatment arms. The incidence of G3-G4 major toxicities by treated patients, was as follows: skin toxicity a: 5%; b: 27%; c: 0%; stomatitis a: 20%; b: 20%; c: 3%. The incidence of neutropenic fever was a: 30%; b: 13%; c: 48%. After a median follow-up of 18 months, no late toxicity has been reported. CONCLUSIONS: The accelerated sequential A-->T-->CMF treatment is not feasible due to an excess of skin toxicity. The sequential non accelerated and the combination regimens are feasible and under evaluation in a phase III trial of adjuvant therapy.

Adult↗

Echocardiographic transponder-guided catheter ablation feasibility and accuracy.

BACKGROUND: The utility of echocardiography for catheter guidance during percutaneous endocardial ablation is increasingly apparent. However, the technique is currently imperfect due to limitations in discerning the ablation electrode from other parts of the catheter shaft. PURPOSE: To examine the feasibility and accuracy of echocardiography-guided ablation using commercial ablation catheters fitted with a transponder to improve localization of the ablation electrode. METHODS: Fifteen healthy pigs and five pigs with chronic anterior myocardial infarction were studied. In healthy animals, echocardiographically distinct endocardial sites in right and left cardiac chambers were targeted for ablation. In infarcted animals, the left ventricular infarction border zone was targeted. Both intracardiac (ICE; 12.5 megahertz and 5 megahertz) and transesophageal echocardiographic (TEE) techniques were utilized. RESULTS: In healthy animals, transponder-guided ablation was feasible with each of the echocardiographic techniques. Accuracy was 82 % (45 of 55 lesions) with ICE-12.5 MHz, 87 % (27 of 31 lesions) with ICE-5 MHz, and 81 % (22 of 27 lesions) with TEE. In infarcted animals, the accuracy was 38 % (3 of 8 lesions) for ICE-5 MHz and 38 % (3 of 8 lesions) for TEE. Errant lesions in healthy animals were observed in earlier experiments, due to operator misinterpretation of the plane of imaging. Errant lesions in infarcted animals were observed throughout the experimental series, and may have been due to a variable relationship between echocardiographic and histologic infarction border zones. CONCLUSIONS: Echocardiographic transponder-guided catheter ablation is feasible. Accuracy for normal endocardial targets was excellent, less so for chronic infarction border.

Animals↗