Steady-state elastohydrodynamic lubrication analysis of a metal-on-metal hip implant employing a metallic cup with an ultra-high molecular weight polyethylene backing.

The elastohydrodynamic lubrication (EHL) analysis was carried out in this study for a 28 mm diameter metal-on-metal hip prosthesis employing a metallic cup with an ultra-high molecular weight polyethylene (UHMWPE) backing under a simple steady state rotation representing the flexion/extension during walking. Both Reynolds and elasticity equations were coupled and solved numerically by the finite difference method. The elastic deformation was determined by means of the fast Fourier transform (FFT) technique using the displacement coefficients obtained from the finite element method. Excellent agreement of the predicted elastic deformation was obtained between the FFT technique and the conventional direct summation method. The number of grid points used in the lubrication analysis was found to be important in predicting accurate film thicknesses, particularly at low viscosities representative of physiological lubricants. The effect of the clearance between the femoral head and the acetabular cup on the predicted lubricant film thickness was shown to be significant, while the effect of load was found to be negligible. Overall, the UHMWPE backing was found not only to reduce the contact pressure as identified in a previous study by the authors (Liu et al., 2003) but also significantly to increase the lubricant film thickness for the 28 mm diameter metal-on-metal hip implant, as compared with a metallic mono-block cup.

Computer Simulation↗

Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement.

An elastohydrodynamic lubrication (EHL) analysis was carried out in this study for a typical McKee-Farrar metal-on-metal hip prosthesis under a simple steady state rotation. The finite element method was used initially to investigate the effect of the cement and bone on the predicted contact pressure distribution between the two articulating surfaces under dry conditions, and subsequently to determine the elastic deformation of both the femoral and the acetabular components required for the lubrication analysis. Both Reynolds equation and the elasticity equation were coupled and solved numerically using the finite difference method. Important features in reducing contact stresses and promoting fluid-film lubrication associated with the McKee-Farrar metal-on-metal hip implant were identified as the large femoral head and the thin acetabular cup. For the typical McKee-Farrar metal-on-metal hip prosthesis considered under typical walking conditions, an increase in the femoral head radius from 14 to 17.4 mm (for a fixed radial clearance of 79 microm) was shown to result in a 25 per cent decrease in the maximum dry contact pressure and a 60 per cent increase in the predicted minimum film thickness. Furthermore, the predicted maximum contact pressure considering both the cement and the bone was found to be decreased by about 80 per cent, while the minimum film thickness was predicted to be increased by 50 per cent. Despite a significant increase in the predicted minimum lubricating film thickness due to the large femoral head and the thin acetabular cup, a mixed lubrication regime was predicted for the McKee-Farrar metal-on-metal hip implant under estimated in vivo steady state walking conditions, depending on the surface roughness of the bearing surfaces. This clearly demonstrated the important influences of the material, design and manufacturing parameters on the tribological performance of these hard-on-hard hip prostheses. Furthermore, in the present contact mechanics analysis, the significant increase in the elasticity due to the relatively thin acetabular cup was not found to cause equatorial contact and gripping of the ball.

Acetabulum↗

Prediction of transient lubricating film thickness in knee prostheses with compliant layers.

The transient lubricating film thickness in knee prostheses using compliant layers has been predicted under simulated walking conditions based upon the elastohydrodynamic lubrication theory. Qualitative agreement has been found between the present theoretical predictions and the experimental measurements using an electric resistance technique reported earlier. It has been shown that the contact geometry plays an important role in the generation of fluid film lubrication in knee prostheses using compliant layers. The maximum lubricating film thickness is predicted for the maximized contact area of a transverse conjunction where the semi-minor contact radius lies in the direction of entraining. The additional advantage of the transverse contact conjunction is that the possibility of lubricant starvation due to small stroke length can be minimized. All these factors, together with the kinematic requirements in the natural knee joint, should be taken into consideration when designing artificial knee joint replacements.

Biocompatible Materials↗

The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests.

Since the implication of polyethylene wear debris as a major cause of osteolysis in total joint replacements, there has been much interest in polyethylene wear studies and in cell culture studies using ultra-high molecular weight polyethylene (UHMWPE) wear debris. Studies have shown that particles in the 0.1-10 microns size range are particularly important in causing adverse cellular reactions resulting in osteolysis. The morphology, the mass and size distributions, and the number of wear particles produced at the joint surfaces are influenced by the tribological conditions at the joint. Laboratory wear tests are used to investigate the wear properties of prosthetic joint materials and different research groups have used different lubricants in these tests. This paper shows that the volumetric wear and morphology of UHMWPE particles generated in vitro are influenced by the type of lubricant used. This study compared, quantitatively, UHMWPE wear debris generated in deionized water to debris that was generated in a system lubricated by bovine serum which was diluted to 25 per cent. The wear factors of UHMWPE in water and serum lubricants were significantly different (p < 0.05). UHMWPE wore 14 times more in water than in serum. Quantitative analysis of the wear particles showed that the debris that was generated in serum was morphologically different from debris that was produced in a water-lubricated system. Furthermore, the particles produced in serum showed a closer similarity to those found in retrieved acetabular tissues.

Blood↗

Demonstration of boundary lubrication by synovial fluid.

An account is given of an oscillatory rotating friction measurement apparatus which can be used for demonstration of boundary lubrication by synovial fluid when rubber and glass are employed as rubbing surfaces. A technical description of the apparatus is given. The greatest importance is placed on getting the apparatus to demonstrate reproducible results when saline and normal bovine synovial fluid are used as lubricant. The greatest variations are caused by differences in the cleaning of the rubber and in its tension. On the basis of bovine synovial fluid from ten different hock joints investigations were made of individual variations and changes occurring during storage at 4 degrees C. The individual variations were found to be of no importance; a decrease in the lubricating effect was observed only after storage for two months. Addition of trypsin confirmed that boundary lubrication by synovial fluid can be related to the protein component. The conclusion is that the apparatus is considered suitable for clinical investigations of boundary lubrication in connection with different joint diseases.

Animals↗

The effect of applying a pipe-joint lubricant to connect ductile iron pipe on off-flavors in drinking water distribution systems.

This study was used to help define the contribution to taste and odor problems caused by the application of a pipe-joint lubricant to connect ductile iron pipe in drinking water distribution systems. Tyton Joint Lubricant (TJL) was studied. The lubricant produced odors that are continually oxidized by chlorine or oxygen. The mechanism of oxidative rancidity, one of the major causes of food spoilage is the apparent mechanism of oxidation. The odors produced by the lubricant were characterized by a Flavor Profile Analysis (FPA) panel as well as GC/MS and Sensory GC analysis. The most common odors perceived in the TJL water samples for the first six days were waxy/oily and soapy odors with a rancid oil, odor note. The waxy/oily and soapy odors decreased with time in the chlorine medium as the rancid oily odor note increased. Numerous aldehydes, ketones, alcohols and borneol compounds, produced from the lubricants, were tentatively identified and linked to the odors perceived by the FPA panel.

Equipment Design↗

The effect of soft lens lubricants on symptoms and lens dehydration.

In order to establish the efficacy of soft lens lubricants and their mode of action, we conducted a controlled, double-masked, randomized study. Symptoms of dryness as well as lens water content were assessed in 30 symptomatic hydroxyethylmethacrylate (HEMA) contact lens wearers who each applied either saline or one of two soft lens lubricants every 2 hours over a 6-hour wearing period. Short- and long-term symptomatic relief from ocular dryness was provided by both lens lubricants (ANOVA, P less than .05). However, neither lubricant was found to be significantly superior to saline. Contact lens dehydration was not significantly reduced by the instillation of any solution. A psychological rather than a physical (lens hydration) or physiological basis to the symptomatic relief provided by soft lens lubricants cannot be discounted.

Adolescent↗

[The role of protein and hyaluronic acid in the synovial fluid in animal joint lubrication].

The purpose of this investigation was to study the role of protein and hyaluronic acid of synovial fluid in the animal joint lubrication. The D-fraction (0.2 micron up to 0.8 micron) from the bovine synovial fluid showed the lowest friction coefficient and contained about 20% protein and 70% hyaluronic acid of the synovial fluid. Protein but not hyaluronic acid of this fraction had lubricating ability, and the protein but not hyaluronic acid could support the lubricating film thickness. By electron microscopic observation hyaluronic acid was 2,000A-5,000A formless mass and the protein complex that had lubricating ability was 200A-300A spherical particle. Through these results I presume that hyaluronic acid enclose the spherical protein particles in its network like a cage of the roller-bearing and the particles can rotate freely like rolling elements of the roller-bearing. It was suggested that the roller-bearing mechanism was performed along with elastohydrodynamic lubrication in animal joint.

Animals↗

In vivo comparison of ocular lubricants in patients having reduced tear film breakup times.

Remarkably, few published reports are available demonstrating human in vivo effectiveness of ocular lubricants under controlled study design. The purpose of this study was to bridge the gap between in vitro or animal models and the clinical utility of ocular lubricant applications. Four (4) marketed ocular lubricants were tested in patients with clinically deficient tear film breakup times (BUT). Although each lubricant showed a similar pharmacodynamic pattern of increasing BUT, the lubricants were very different in the degree of increased BUT produced over a two-hour study period.

Adult↗

Role of uppermost superficial surface layer of articular cartilage in the lubrication mechanism of joints.

The uppermost superficial surface layer of articular cartilage, the 'lamina splendens' which provides a very low friction lubrication surface in articular joints, was investigated using atomic force microscopy (AFM). Complementary specimens were also observed under SEM at -10 degrees C without dehydration or sputter ion coating. Fresh adult pig osteochondral specimens were prepared from the patellas of pig knee joints and digested with the enzymes, hyaluronidase, chondroitinase ABC and alkaline protease. Friction coefficients between a pyrex glass plate and the osteochondral specimens digested by enzymes as well as natural (undigested) specimens were measured, using a thrust collar apparatus. Normal saline, hyaluronic acid (HA) and a mixture of albumin, globulin, HA (AGH) were used as lubrication media. The surface irregularities usually observed in SEM studies were not apparent under AFM. The articular cartilage surface was resistant to hyaluronidase and also to chondroitinase ABC, but a fibrous structure was exhibited in alkaline protease enzymes-digested specimens. AFM analysis revealed that the thickness of the uppermost superficial surface layer of articular cartilage was between 800 nm and 2 microm in adult pig articular cartilage. The coefficient of friction (c.f.) was significantly higher in chondroitinase ABC and alkaline protease enzymes digested specimens. Generally, in normal saline lubrication medium, c.f. was higher in comparison to HA and AGH lubrication media. The role of the uppermost, superficial surface layer of articular cartilage in the lubrication mechanism of joints is discussed.

Animals↗

Kinetic friction and atomistic instabilities in boundary-lubricated systems.

The contribution of sliding-induced, atomic-scale instabilities to the kinetic friction force is investigated by molecular dynamics. For this purpose, we derive a relationship between the kinetic friction force F(k) and the nonequilibrium velocity distribution P(v) of the lubricant particles. P(v) typically shows exponential tails, which cannot be described in terms of an effective temperature. It is investigated which parameters control the existence of instabilities and how they affect P(v) and hence F(k). The effects of the interfaces' dimensionality, lubricant coverage, and internal degrees of freedom of lubricant particles on F(k) are studied explicitly. Among other results, we find that the kinetic friction between commensurate surfaces is much more susceptible to changes in (i) lubricant coverage, (ii) sliding velocity, and (iii) bond length of lubricant molecules than incommensurate surfaces.

Journal Article↗

Ordering of a thin lubricant film due to sliding.

A thin lubricant film confined between two substrates in moving contact is studied using Langevin molecular dynamics with the coordinate- and velocity-dependent damping coefficient. It is shown that an optimal choice of the interaction within the lubricant can lead to minimal kinetic friction as well as to low critical velocity of the stick-slip to smooth-sliding transition. The strength of this interaction should be high enough (relative to the strength of the interaction of lubricant atoms with the substrates) so that the lubricant remains in a solid state during sliding. At the same time, the strength of the interaction should not be too high, in order to allow annealing of defects in the lubricant at slips.

Journal Article↗

Graphite-like lubrication of mesothelium by oligolamellar pleural surfactant.

Six studies have been completed to reevaluate pleural surfactant as a possible boundary lubricant in mesothelial sliding. It is capable of remarkable antiwear action, giving a mean scar diameter on a standard "four-ball test" comparable to the best commercially available lubricants and reducing friction to values anticipated from lamellated solid lubricants such as graphite. Pleural surfaces displayed appreciable hydrophobicity, which was almost eliminated by rinsing with a lipid solvent from which phospholipid was recovered and quantified. These quantities indicated that equivalent of 7.3 adsorbed monolayers of surface-active phospholipid, which was in general agreement with the number of layers of a graphite-like surface coating visualized by electron microscopy by use of a novel fixation procedure that avoids conventional aldehydes known to destroy hydrophobic surfaces. Graphite-like (dry) lubrication by adsorbed surface-active phospholipid is discussed as an excellent lubrication system available wherever the distribution of fluid allows the pleura to make contact.

Animals↗

The effect of porosity of articular cartilage on the lubrication of a normal human hip joint.

The effect of porosity of articular cartilage on the lubrication of a normal human hip joint has been studied. The poroelasticity equation of articular cartilage and the modified Reynolds equation for the synovial fluid lubricant have been successfully solved under squeeze-film motion and for the conditions experienced in a normal human hip joint. It has been shown that porosity of the articular cartilage depletes the lubricant film thickness, rather than increasing it, particularly when the lubricant film thickness becomes small. Furthermore, it has been shown that articular cartilage can be treated as a single-phase incompressible elastic material in the lubrication modelling under physiological walking conditions.

Cartilage, Articular↗

Characterization of condom lubricant components using Raman spectroscopy and Raman chemical imaging.

A condom can be described as a protective sheath used as a contraceptive or to protect against sexually transmitted diseases. However, individuals also use condoms during the commission of sexual assaults to prevent identification through deposited biological material. Raman spectroscopy offers a novel approach to identifying the presence of condom lubricant components. Furthermore, Raman chemical imaging expands on conventional Raman spectroscopy to characterize multiple condom lubricant components simultaneously in a manner that effectively demonstrates heterogeneous sample mixtures both spectrally and spatially. Known reference materials, liquid and solid lubricant components of common condom brands were successfully characterized using Raman dispersive spectroscopy and Raman chemical imaging without extensive sample preparation inherent to other analytical methods. The characterization of these materials demonstrates the potential of this technique to become a routine screening method for condom lubricants. This preliminary investigation provides a basis for future studies to determine the feasibility of Raman spectroscopy and Raman chemical imaging for condom lubricant trace detection in case type samples.

Condoms↗

Evaluation of Astroglide, a new vaginal lubricant: effects of length of exposure and concentration on sperm motility.

Traditional vaginal lubricants have been shown to adversely affect sperm motility. Astroglide, a new vaginal lubricant, and K-Y Jelly were tested at varying concentrations to assess their suitability for infertility patients requiring a lubricant. The vaginal lubricants tested impaired sperm motility in a concentration-dependent but not time-dependent manner. We conclude that all traditional vaginal lubricants should be avoided in patients desiring conception. Future studies should attempt to mimic in vivo conditions and focus on concentration-dependent effects.

Cellulose↗

The fallacy of evaluating biomaterial wear-rates with water as lubricant: a hip simulator study of alumina-PTFE nd CoCr-PTFE combinations.

Controversy surrounds wear data from hip-simulator studies, whether from the choice of lubricants or other parameters such as the particular biomaterial combinations used, and whether any such interactions could bias the resulting wear predictions. To investigate these phenomena, we studied the wear performance of CoCr and alumina femoral heads, in water and serum-based lubricants, using as our standard the polytetrafluoroethylene wear data derived clinically by Charnley. To model Charnley's clinical experience, PTFE acetabular cups were used in sets of three each with each size of femoral head for 22.25, 28, and 42-mm diameters in a nine-channel hip simulator. From the serum-based tests, the CoCr-PTFE wear data were consistently linear with duration of test, exhibited very large wear rates of 3,000-8,400 mm3/10(6), cycles had a precision within +/- 4% for each set of three cups, and copious amounts of small particulate were clearly seen circulating. The wear data clearly demonstrated Charnley's thesis that volume of wear increased with regard to size of femoral head. From the water-based tests, the CoCr-PTFE wear data were nonlinear with duration of test, had much reduced wear rates compared to the serum tests, lost the clinical relationship with ball size, and precision deteriorated to +/- 27% for each set. The wear debris appeared as 1-2 cm long ribbons which floated to the surface. For the alumina-PTFE combination in serum, the wear data appeared identical in performance to the CoCr-PTFE data in serum. Thus, the PTFE wear rates were not sensitive to the choice of femoral-head material. The most surprising outcome in this study was the zero-wear performance of the ceramic-PTFE combination in water. This contrasted remarkably with the large wear rates established for the same combinations run in serum. The zero-wear performance of the ceramic-PTFE combination in water was unexpected, but a similar phenomenon was noted in published simulator tests of ceramic-UHMWPE run in water. It now seems likely that such data may reflect the capricious behavior of water lubrication rather than any other variables under evaluation. The water-based experiments clearly favored the ceramic's superior tribological performance and placed metal bearings at a decided disadvantage. Therefore, for an in vitro simulation of materials wear-ranking of clinical relevance, it may be advisable to use a serum-based lubricant.

Alloys↗

Comparison of the boundary-lubricating ability of bovine synovial fluid, lubricin, and Healon.

Purified human umbilical hyaluronate and a commercial preparation of rooster comb hyaluronate (Healon) intended for intra-articular viscosupplementation did not demonstrate the same degree of boundary-lubricating ability as bovine synovial fluid or its purified lubricating mucin, lubricin (p < 0.01). Boundary lubrication was measured in vitro in an arthrotripsometer oscillating natural latex against polished glass under a load of 0.35 MPa with an entraining velocity of 0.37 mm/s. The two hyaluronate solutions possessed the same hyaluronate concentration as synovial fluid, but Healon was 4.5 times more viscous. Present practice of viscosupplementation therapy for degenerative joint disease is limited and fails to implicate the important role of synovial mucin. Boundary lubrication provided by synovial mucin, independent of its viscosity, is not replicated by hyaluronate hydrogels.

Animals↗