PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Determination of SARS-coronavirus by a microfluidic chip system.

We have developed a new experimental system based on a microfluidic chip to determine severe acute respiratory syndrome coronavirus (SARS-CoV). The system includes a laser-induced fluorescence microfluidic chip analyzer, a glass microchip for both polymerase chain reaction (PCR) and capillary electrophoresis, a chip thermal cycler based on dual Peltier thermoelectric elements, a reverse transcription-polymerase chain reaction (RT-PCR) SARS diagnostic kit, and a DNA electrophoretic sizing kit. The system allows efficient cDNA amplification of SARS-CoV followed by electrophoretic sizing and detection on the same chip. To enhance the reliability of RT-PCR on SARS-CoV detection, duplex PCR was developed on the microchip. The assay was carried out on a home-made microfluidic chip system. The positive and the negative control were cDNA fragments of SARS-CoV and parainfluenza virus, respectively. The test results showed that 17 positive samples were obtained among 18 samples of nasopharyngeal swabs from clinically diagnosed SARS patients. However, 12 positive results from the same 18 samples were obtained by the conventional RT-PCR with agarose gel electrophoresis detection. The SARS virus species can be analyzed with high positive rate and rapidity on the microfluidic chip system.

Autopsy↗

Development of a low-cost microfluidic capillary-electrophoresis system coupled with flow-injection and sequential-injection sample introduction (review).

Microfabrication techniques used for the production of MEMS (micro electro-mechanical systems) have been successfully used to produce highly efficient microfluidic capillary electrophoresis chip systems. A limitation of this approach are the difficulties associated with the creation of the micrometer-sized structures in glass or other substrates, which currently involve specialized and expensive lithographic and etching processes. A further limitation is that hitherto most microfluidic chips are not designed for continuous introduction of a series of different samples, which limits the overall throughput of such systems. This article reviews the development of a microfluidic system for rapid CE separations, produced at a low cost of less than a dollar each, using equipment and materials readily available in the ordinary laboratory. Applications of the system, after coupling to flow-injection and/or sequential-injection sample introduction, for the determination of FITC-labeled amino acids by laser-induced fluorescence, trace metals by chemiluminescence, carbohydrates by amperometry, and inorganic and organic anions by indirect UV absorbance are exemplified to illustrate the performance and versatility of the microfluidic system.

Journal Article↗

The effect of microfluidization of protein-coated liposomes on protein distribution on the surface of generated small vesicles.

Tetanus toxoid and immunoglobulin G (IgG), model proteins for vaccines and targeting ligands respectively, were covalently coupled to preformed dehydration-rehydration vesicles (DRV) to produce vesicles with surface-bound proteins (DRV-protein) or to preformed small unilamellar vesicles (SUV) which were used to generate DRV with bound protein [(SUV-protein)DRV]. Of the amount of protein employed for coupling (1 mg), 13.8-45.1% was recovered with the liposomes, depending on the type of preparations and the proteins used. Microfluidization of similar DRV-protein or (SUV-protein)DRV for up to 10 cycles led to the formation of smaller vesicles (98-136 mm diameter) which, however, had modestly reduced (estimated as 8.8-21.7%) bound proteins, again depending on the type of preparation and protein used. Treatment of DRV-protein and (SUV-protein) DRV with proteinase revealed that 32.9-45.6% of the total bound protein was exposed on the liposomal surface. With microfluidized liposomes, the proportion of surface-exposed protein increased to 63.1-76.2%. Incubation of intact and microfluidized DRV-IgG and (SUV-IgG) DRV with a protein A-Sepharose 4B CL gel confirmed the presence of IgG on the liposomal surface (47.1-68.4 and 80.5-82.1% of total bound protein respectively). These studies were supplemented with freeze-fracture electron microscopy of (SUV-toxoid)DRV which demonstrated the presence of protein particles (up to 3; 12-14 nm diameter) on the surface of both intact and microfluidized individual liposomes.

Desiccation↗

Trends in the development of microfluidic cell biochips for in vitro hepatotoxicity.

Current developments in the technological fields of liver tissue engineering, bioengineering, biomechanics, microfabrication and microfluidics have lead to highly complex and pertinent new tools called "cell biochips" for in vitro toxicology. The purpose of "cell biochips" is to mimic organ tissues in vitro in order to partially reduce the amount of in vivo testing. These "cell biochips" consist of microchambers containing engineered tissue and living cell cultures interconnected by a microfluidic network, which allows the control of microfluidic flows for dynamic cultures, by continuous feeding of nutrients to cultured cells and waste removal. Cell biochips also allow the control of physiological contact times of diluted molecules with the tissues and cells, for rapid testing of sample preparations or specific addressing. Cell biochips can be situated between in vitro and in vivo testing. These types of systems can enhance functionality of cells by mimicking the tissue architecture complexities when compared to in vitro analysis but at the same time present a more rapid and simple process when compared to in vivo testing procedures. In this paper, we first introduce the concepts of microfluidic and biochip systems based on recent progress in microfabrication techniques used to mimic liver tissue in vitro. This includes progress and understanding in biomaterials science (cell culture substrate), biomechanics (dynamic cultures conditions) and biology (tissue engineering). The development of new "cell biochips" for chronic toxicology analysis of engineered tissues can be achieved through the combination of these research domains. Combining these advanced research domains, we then present "cell biochips" that allow liver chronic toxicity analysis in vitro on engineered tissues. An extension of the "cell biochip" idea has also allowed "organ interactions on chip", which can be considered as a first step towards the replacement of animal testing using a combined liver/lung organ model.

Animals↗

Microfluidic chip-based method for genotyping microsatellites, VNTRs and insertion/deletion polymorphisms.

We have developed a method to genotype variable number of tandem repeats (VNTRs) and insertion/deletion polymorphisms using an integrated microfluidic chip-based system. We used this method to analyze a) a highly polymorphic pentanucleotide repeat (CCTTT)(n) locus within the 5'-putative promoter region of the human inducible nitric oxide synthase gene (iNOS5) which is associated with diabetic complications and infectious diseases; b) a bi-allelic 27 bp VNTR region within intron 4 of endothelial nitric oxide gene (eNOS27) which is associated with hypertension in type 2 diabetes patients with coronary heart disease and excess risk of advanced diabetic nephropathy in type 1 diabetes patients and c) an insertion/deletion polymorphism within the gene encoding angiotensin-converting enzyme (ACE/ID) which is associated with cardiovascular pathology and nitric oxide activity, and is in strong linkage disequilibrium with functional variants. Following amplifications, samples were mixed with gel-dye and markers and loaded into commercially available microfluidic chips designed for DNA sizing applications. In the study (N = 230), 95 (41%) of the DNA samples were homozygous and 135 (59%) were heterozygous for the iNOS5 repeats. For eNOS27, 173 (75%) of the genotyped DNA samples were homozygous for the larger 4b allele and the remaining 57 samples (25%) were heterozygous (4b/4a). No DNA samples were homozygous for the shorter 4a allele with four 27 bp repeats. In case of ACE/ID, 47 (20%) of the DNA samples were homozygous for the insertion, 65 (28%) were homozygous for the deletion and the remaining 118 (51%) were heterozygous. The results obtained were verified by analyzing random amplicons using bi-directional sequencing and GeneScan 3.0 analyses with 100% concordance being observed. Using the microfluidic chip-based method, separation and DNA sizing and genotyping are rapidly accomplished. The DNA fragments are resolved clearly and the system allows quantitation. Finally, the microfluidic chip-based method may be used for both large- and small-scale genotyping studies.

Alleles↗

Hydrogel-based microreactors as a functional component of microfluidic systems.

A simple two-step method for fabricating poly(ethylene glycol) (PEG) hydrogel-based microreactors and microsensors within microfluidic channels is described. The intrachannel micropatches contain either a dye, which can report the pH of a solution within a fluidic channel, or enzymes that are able to selectively catalyze specific reactions. Analytes present within the microfluidic channel are able to diffuse into the micropatches, encounter the enzymes, and undergo conversion to products, and then the products interact with the coencapsulated dye to signal the presence of the original substrate. The micropatches are prepared by photopolymerizing the PEG precursor within the channel of a microfluidic system consisting of a poly(dimethylsiloxane) mold and a glass plate. Exposure takes place through a slit mask oriented perpendicular to the channel, so the size of the resulting micropatch is defined by the channel dimensions and the width of the slit mask. Following polymerization, the mold is removed, leaving behind the micropatch(es) atop the glass substrate. The final microfluidic device is assembled by irreversibly binding the hydrogel-patterned glass slide to a second PDMS mold that contains a larger channel. Multiple micropatches containing the same or different enzymes can be fabricated within a single channel. The viability of this approach is demonstrated by sensing glucose using micropatches copolymerized with glucose oxidase, horseradish peroxidase, and a pH-sensitive dye.

Journal Article↗

Electrokinetic focusing injection methods on microfluidic devices.

This paper presents an experimental and numerical investigation into electrokinetic focusing injection on microfluidic chips. The valving characteristics on microfluidic devices are controlled through appropriate manipulations of the electric potential strengths during the sample loading and dispensing steps. The present study also addresses the design and testing of various injection systems used to deliver a sample plug. A novel double-cross injection microfluidic chip is fabricated, which employs electrokinetic focusing to deliver sample plugs of variable volume. The proposed design combines several functions of traditional sample plug injection systems on a single microfluidic chip. The injection technique uses an unique sequence of loading steps with different electric potential distributions and magnitudes within the various channels to effectuate a virtual valve.

Journal Article↗

Fluorescent ion-selective optode membranes incorporated onto a centrifugal microfluidics platform.

The development of an integrated analysis system for small ions based on ion-selective optodes and centrifugal microfluidics is reported. The performance of this system was evaluated through five-point calibration plots for two types of optode membranes, one being cation-selective and the other anion-selective, which were incorporated into a microfluidics platform on which fluid motion is induced via angular rotation. Additionally, the application of the microfluidic platform to ion analysis is studied via a two-point calibration protocol used to quantify an unknown sample. Calibrant solutions are delivered from reservoirs fabricated onto the platform to a measuring area that contains the optode membrane, with a change in membrane fluorescence being monitored. This work demonstrates the first instance of a microfluidic-based analysis system with detection based on ion-selective optode membranes monitored with fluorescence transduction. Furthermore, in addition to employing a standard excitation source where a fiber-optic probe is coupled to a tungsten-halogen lamp, laser diodes such as those employed in portable CD/DVD players were studied as excitation sources to enhance the observed fluorescence signals.

Journal Article↗

A microfluidic bioreactor based on hydrogel-entrapped E. coli: cell viability, lysis, and intracellular enzyme reactions.

Viable E. coli cells were entrapped in hydrogel micropatches photopolymerized within microfluidic systems. The microfluidic channels and the micropatches have sizes on the order of 100-500 microm. Small molecules, such as dyes and surfactants, present in the solution surrounding the hydrogel, are able to diffuse into the gel and encounter the cells, but the cells are sufficiently large to be retained. For example, sodium dodecyl sulfate is a lysis agent that is able to penetrate the hydrogel and disrupt the cellular membrane. Entrapment of viable cells within hydrogels, followed by lysis, could provide a convenient means for preparing biocatalysts without the need for enzyme extraction and purification. Hydrogel-immobilized cells are able to carry out chemical reactions within microfluidic channels. Specifically, a nonfluorescent dye, BCECF-AM, is able to penetrate both the hydrogel and the bacterial membrane and be converted into a fluorescent form (BCECF) by the interior cellular machinery. These results suggest that cells immobilized within microfluidic channels can act as sensors for small molecules and as bioreactors for carrying out reactions.

Bioreactors↗

Tandem isotachophoresis-zone electrophoresis via base-mediated destacking for increased detection sensitivity in microfluidic systems.

Electrophoresis in microfluidic devices is becoming a useful analytical platform for a variety of biological assays. In this report, we present a method that allows for an increased sensitivity of detection of fluorescent molecules in microfluidic electrophoresis devices. This capability is provided by the implementation of a particular buffer system that is designed to initially function in an isotachophoretic (ITP) mode and, then after a controlled amount of electric current has been applied to the system, to transition to a zone electrophoretic mode. In the initial ITP mode, analytes dissolved in a large volume of injected sample are concentrated into a single narrow zone. After application of a sufficient and adjustable amount of electric current, the system switches into a zone electrophoretic mode, where the concentrated analytes are separated according to their electrophoretic mobilities. Application of this tandem ITP-zone electrophoretic strategy to the concentration, separation, and detection of fluorescent reporter molecules in a standard microfluidic device results in an approximately 50-fold increase in detection sensitivity relative to equivalent separations that are obtained with zone electrophoresis alone. Even with very long initial sample plugs (up to 3000 microm), this strategy produces electrophoretic separations with high resolutions and peak efficiencies. This strategy can be implemented to increase detection sensitivity in any standard microfluidic electrophoresis platform and does not require any specialized hardware or microchannel configurations.

Buffers↗

Capillary-assembled microchip for universal integration of various chemical functions onto a single microfluidic device.

A novel concept for assembling various chemical functions onto a single microfluidic device is proposed. The concept, called a capillary-assembled microchip, involves embedding chemically functionalized capillaries into a lattice microchannel network fabricated on poly(dimethylsiloxane) (PDMS). The network has the same channel dimensions as the outer dimensions of the capillaries. In this paper, we focus on square capillaries to be embedded into a PDMS microchannel network having a square cross section. The combination of hard glass square capillary and soft square PDMS channel allows successful fabrication of a microfluidic device without any solution leakage, and which can use diffusion-based two-solution mixing. Two different types of chemically modified capillaries, an ion-sensing capillary and a pH-sensing capillary, are prepared by coating a hydrophobic plasticized poly(vinyl chloride) membrane and a hydrophilic poly(ethyleneglycol) membrane containing functional molecules onto the inner surface of capillaries. Then, they are cut into appropriate lengths and arranged on a single microchip to prepare a dual-analyte sensing system. The concept proposed here offers advantages inherent to using a planar microfluidic device and of chemical functionality of immobilized molecules. Therefore, we expect to fabricate various types of chemically functionalized microfluidic devices soon.

Journal Article↗

Printed circuit technology for fabrication of plastic-based microfluidic devices.

One of the primary advantages of using plastic-based substrates for microfluidic systems is the ease with which devices can be fabricated with minimal dependence on specialized laboratory equipment. These devices are often produced using soft lithography techniques to cast replicas of a rigid mold or master incorporating a negative image of the desired surface structures. Conventional photolithographic micromachining processes are typically used to construct these masters in either thick photoresist, etched silicon, or etched glass substrates. The speed at which new masters can be produced using these techniques, however, can be relatively slow and often limits the rate at which new device designs can be built and tested. In this paper, we show that inexpensive photosensitized copper clad circuit board substrates can be employed to produce master molds using conventional printed circuit technology. This process offers the benefits of parallel fabrication associated with photolithography without the need for cleanroom facilities, thereby providing a degree of speed and simplicity that allows microfluidic master molds with well-defined and reproducible structural features to be constructed in approximately 30 min in any laboratory. Precise control of channel heights ranging from 15 to 120 microm can be easily achieved through selection of the appropriate copper layer thickness, and channel widths as small as 50 microm can be reproducibly obtained. We use these masters to produce a variety of plastic-based microfluidic channel networks and demonstrate their suitability for DNA electrophoresis and microfluidic mixing studies.

DNA↗

Solvent-resistant photocurable liquid fluoropolymers for microfluidic device fabrication [corrected].

We report the first fabrication of a solvent-compatible microfluidic device based on photocurable "Liquid Teflon" materials. The materials are highly fluorinated functionalized perfluoropolyethers (PFPEs) that have liquidlike viscosities that can be cured into tough, highly durable elastomers that exhibit the remarkable chemical resistance of fluoropolymers such as Teflon. Poly(dimethylsiloxane) (PDMS) elastomers have rapidly become the material of choice for many recent microfluidic device applications. Despite the advantages of PDMS in relation to microfluidics technology, the material suffers from a serious drawback in that it swells in most organic solvents. The swelling of PDMS-based devices in organic solvents greatly disrupts the micrometer-sized features and makes it impossible for fluids to flow inside the channels. Our approach to this problem has been to replace PDMS with photocurable perfluoropolyethers. Device fabrication and valve actuation were accomplished using established procedures for PDMS devices. The additional advantage of photocuring allows fabrication time to be decreased from several hours to a matter of minutes. The PFPE-based device exhibited mechanical properties similar to those of Sylgard 184 before and after curing as well as remarkable resistance to organic solvents. This work has the potential to expand the field of microfluidics to many novel applications.

Journal Article↗

Generation of concentration gradient by controlled flow distribution and diffusive mixing in a microfluidic chip.

We have developed a simple method to generate a concentration gradient in a microfluidic device. This method is based on the combination of controlled fluid distribution at each intersection of a microfluidic network by liquid pressure and subsequent diffusion between laminas in the downstream microchannel. A fluid dynamic model taking into account the diffusion coefficient was established to simulate the on-chip flow distribution and diffusion. Concentration gradients along a distance of a few hundred micrometers were generated in a series of microchannels. The gradients could be varied by carefully regulating the liquid pressure applied to the sample injection vials. The observed concentration gradients of fluorescent dyes generated on the microfluidic channel are consistent with the theoretically predicted results. The microfluidic design described in this study may provide a new tool for applications based on concentration gradients, including many biological and chemical analyses such as cellular reaction monitoring and drug screening.

Journal Article↗

Design and fabrication of a multilayered polymer microfluidic chip with nanofluidic interconnects via adhesive contact printing.

The design and fabrication of a multilayered polymer micro-nanofluidic chip is described that consists of poly(methylmethacrylate) (PMMA) layers that contain microfluidic channels separated in the vertical direction by polycarbonate (PC) membranes that incorporate an array of nanometre diameter cylindrical pores. The materials are optically transparent to allow inspection of the fluids within the channels in the near UV and visible spectrum. The design architecture enables nanofluidic interconnections to be placed in the vertical direction between microfluidic channels. Such an architecture allows microchannel separations within the chip, as well as allowing unique operations that utilize nanocapillary interconnects: the separation of analytes based on molecular size, channel isolation, enhanced mixing, and sample concentration. Device fabrication is made possible by a transfer process of labile membranes and the development of a contact printing method for a thermally curable epoxy based adhesive. This adhesive is shown to have bond strengths that prevent leakage and delamination and channel rupture tests exceed 6 atm (0.6 MPa) under applied pressure. Channels 100 microm in width and 20 microm in depth are contact printed without the adhesive entering the microchannel. The chip is characterized in terms of resistivity measurements along the microfluidic channels, electroosmotic flow (EOF) measurements at different pH values and laser-induced-fluorescence (LIF) detection of green-fluorescent protein (GFP) plugs injected across the nanocapillary membrane and into a microfluidic channel. The results indicate that the mixed polymer micro-nanofluidic multilayer chip has electrical characteristics needed for use in microanalytical systems.

Journal Article↗

A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion.

Producing robust and scalable fluid metering in a microfluidic device is a challenging problem. We developed a scheme for metering fluids on the picoliter scale that is scalable to highly integrated parallel architectures and is independent of the properties of the working fluid. We demonstrated the power of this method by fabricating and testing a microfluidic chip for rapid screening of protein crystallization conditions, a major hurdle in structural biology efforts. The chip has 480 active valves and performs 144 parallel reactions, each of which uses only 10 nl of protein sample. The properties of microfluidic mixing allow an efficient kinetic trajectory for crystallization, and the microfluidic device outperforms conventional techniques by detecting more crystallization conditions while using 2 orders of magnitude less protein sample. We demonstrate that diffraction-quality crystals may be grown and harvested from such nanoliter-volume reactions.

Crystallization↗

Microfluidic patterning of cells in extracellular matrix biopolymers: effects of channel size, cell type, and matrix composition on pattern integrity.

The organization of cells within an extracellular matrix is critical to promote appropriate cellular interactions and tissue function in vivo. The ability to design and create biologically relevant cellular arrangements via microfluidic patterning on surfaces provides new capabilities for tissue engineering and biomimetics. The purpose of this article is to describe techniques using microfluidic patterning of three-dimensional biopolymer matrices to improve cellular pattern integrity and to provide microscale control over cellular microenvironments. Results demonstrated that the incorporation of extracellular matrix biopolymers in cell microfluidic patterning results in a more stable pattern of adherent human endothelial cells than patterning without matrix components after several days in vitro. This may be important for carrying out long-term biological experiments and tissue engineering in vitro. Moreover, chemical components in the patterned biopolymer matrices, such as collagen, chitosan, and fibronectin, influenced the ability of the matrices to control cell migration and pattern stability over time. Thus, microfluidic patterning of cells in extracellular matrix biopolymers was shown to be useful in patterning multiple cell types in well-defined three-dimensional geometries.

Biopolymers↗

Microfluidic large-scale integration.

We developed high-density microfluidic chips that contain plumbing networks with thousands of micromechanical valves and hundreds of individually addressable chambers. These fluidic devices are analogous to electronic integrated circuits fabricated using large-scale integration. A key component of these networks is the fluidic multiplexor, which is a combinatorial array of binary valve patterns that exponentially increases the processing power of a network by allowing complex fluid manipulations with a minimal number of inputs. We used these integrated microfluidic networks to construct the microfluidic analog of a comparator array and a microfluidic memory storage device whose behavior resembles random-access memory.

Biochemistry↗