PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring, Physiologic”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

The role of physiologic monitoring in patients with fractures of the hip.

Mortality rates for elderly patients with hip fractures have been reported to be as high as 37%. This study evaluated 70 patients of whom 35 were evaluated preoperatively by conventional diagnostic means, and 35 in whom hemodynamic, respiratory, and metabolic status was assessed using a Swan-Ganz balloon-tipped catheter. The derived variables were then calculated by a minicomputer and automatically plotted on a printed graphic display in a bar graph format. This diagnostic modality permitted appreciation of occult physiologic aberrations not detected by conventional methods, enabling correction of these abnormalities preoperatively and postoperatively. The study demonstrated a mortality rate of 2.9% in the monitored group compared to a 29% mortality in the nonmonitored group. The intrinsic assumption that patients should undergo surgery within 24 hours (3) was also modified. The appropriate time for surgery should be accurately determined and chosen on the basis of optimal physiologic balance.

Adult↗

Psycho-physiological monitoring in real and simulated space flight conditions.

Earlier in simulating experiments from long isolation of small group in hermetic cabin we were found out the significant interrelation between changes physiological parameters and subjective appraisal of a condition, activity regulating systems of organism, individual variability of a colour choice, and also quality of operator's activity. On the basis of these results we develop a method of psychophysiological monitoring. The important component of a method is study of the variational characteristics of registered parameters, with the purpose of reception of the information about character of transients in organism. The present research is carried out in conditions of 135-daily isolation in a breadboard model MIR station (experiment HUBES). Its PURPOSE was study of dynamic psycho-emotional condition, simultaneously with study physiological and biochemical parameters, describing process of adaptation to complex conditions of ability to live. Besides were analyzed the results of circadian rhythm's researches during space flights of 6 Russian cosmonauts (duration from 70 till 182 days) on orbital MIR station.

Adaptation, Physiological↗

Cerebrovascular responses under controlled and monitored physiological conditions in the anesthetized mouse.

Control of physiological parameters such as respiration, blood pressure, and arterial blood gases has been difficult in the mouse due to the lack of technology required to monitor these parameters in small animals. Here we report that anesthetized and artificially ventilated mice can be maintained under physiological control for several hours with apparently normal cerebrovascular reactivity to hypercapnia and mechanical vibrissal stimulation. SV-129 mice were anesthetized with urethane (750 mg/kg i.p.) and alpha-chloralose (50 mg/kg i.p.), intubated, paralyzed, and artificially ventilated. Respiratory control was maintained within physiological range by reducing the inspiratory phase of the respiratory cycle to < 0.1 s and by adjusting end-tidal CO2 to give a PCO2 of 35 +/- 3 mm Hg. In these mice, mean arterial pressure (95 +/- 9 mm Hg), heart rate (545 +/- 78 beats/min), and arterial pH (7.27 +/- 0.10) could be maintained for several hours. Body temperature was kept at 36.5-37.5 degrees C. We observed stable regional CBF (rCBF) measurements (as determined by laser-Doppler flowmetry) when systemic arterial blood pressure was varied between 40 and 130 mm Hg. Hypercapnia led to a 38 +/- 15% (5% CO2) and 77 +/- 34% (10% CO2) increase in rCBF. Mechanical stimulation of contralateral vibrissae for 1 min increased rCBF by 14 +/- 4%. Changes in rCBF compare favorably with those observed previously in another rodent species, the Sprague-Dawley rat. After placement of a closed cranial window, cerebrovascular reactivity to hypercapnia and whisker stimulation was intact and well maintained during 2-h superfusion with artificial CSF.

Anesthesia↗

Current issues related to home monitoring.

Physiologic monitoring is no longer confined to the critical care unit. Home monitors connect patients with clinics, physician offices, disease management programs, and home care agencies for the purpose of streamlining care delivery, maintaining a close patient connection, and promoting early identification of patient status changes. The advent of telehealth technologies offers a wide range of options for home monitoring. The goal of home monitoring is to promote patient comfort and avoid disruption of daily activities. To accomplish this, however, nurses must address issues such as, technology compatibility with patient capabilities, compatibility with nurses' practice beliefs, cost of home monitoring of overall care, and the physiologic parameters that will measure early decompensation.

Community Health Nursing↗

Use of sensory-evoked potentials recorded from the human occiput for intraoperative physiologic monitoring of the spinal cord.

STUDY DESIGN: This is a report of a prospective case series. OBJECTIVE: The purpose of this study was to determine whether evoked potential activity recorded from occipital scalp electrodes in humans is similar to that recorded in animals, and to evaluate the independence of this activity from the classical somatosensory-evoked potential. SUMMARY OF BACKGROUND DATA: Intraoperative somatosensory-evoked potentials can be of limited usefulness in predicting spinal cord injury because they are transmitted primarily through the dorsal columns, and therefore do not reflect integrity of important ventral pathways. It recently has been shown in animal studies that a sensory-evoked potential recorded from the cerebellum is mediated via ventral tracts and is useful as an adjunct to the somatosensory-evoked potential in spinal cord monitoring. METHODS: Twenty-five patients undergoing spinal or posterior fossa surgery were consecutively entered into the study. Evoked responses were recorded transcranially from over the cerebellar hemispheres and from the vertex. Recordings were made directly from the surface of the cerebellar hemispheres in seven of these patients. RESULTS: Waveforms could be recorded and reproduced in all but one of the patients. The overall appearance of the occipital recordings was similar to the appearance of responses obtained in animals. The mean latency of the first negative peak recorded from the ipsilateral occiput was 33.0 msec (standard deviation, 3.7 msec) compared with 52.4 msec (standard deviation, 6.1 msec) for the somatosensory-evoked potential. In addition, the amplitude of this response (0.35 microV; standard deviation, 0.20 microV) was independent of the amplitude of the somatosensory-evoked potential (0.76 microV; standard deviation, 0.69 microV). In five cases, one evoked potential could be recorded in the absence of the other. Recordings from the surface of the cerebellum were of the same morphology, but of greater amplitude than the transcranial recordings. CONCLUSION: Evoked responses can be reliably recorded from over the occiput and show characteristics independent of the classical somatosensory-evoked potential. These responses are very similar to the cerebellar-evoked potential recently characterized in animals and may provide a method for assessing the physiologic integrity of the ventral tracts of the spinal cord in humans.

Animals↗

Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables.

In the last few years, the smart textile area has become increasingly widespread, leading to developments in new wearable sensing systems. Truly wearable instrumented garments capable of recording behavioral and vital signals are crucial for several fields of application. Here we report on results of a careful characterization of the performance of innovative fabric sensors and electrodes able to acquire vital biomechanical and physiological signals, respectively. The sensing function of the fabric sensors relies upon newly developed strain sensors, based on rubber-carbon-coated threads, and mainly depends on the weaving topology, and the composition and deposition process of the conducting rubber-carbon mixture. Fabric sensors are used to acquire the respitrace (RT) and movement sensors (MS). Sensing features of electrodes, instead rely upon metal-based conductive threads, which are instrumental in detecting bioelectrical signals, such as electrocardiogram (ECG) and electromyogram (EMG). Fabric sensors have been tested during some specific tasks of breathing and movement activity, and results have been compared with the responses of a commercial piezoelectric sensor and an electrogoniometer, respectively. The performance of fabric electrodes has been investigated and compared with standard clinical electrodes.

Biomechanical Phenomena↗

Use of intrinsic optical signals to monitor physiological changes in brain tissue slices.

Optical imaging techniques have the potential to bring a combination of high spatial and temporal resolution to studies of brain function. Many optical techniques require the addition of a dye or fluorescent marker to the tissue, and such methods have proven extremely valuable. It is also known that the intrinsic optical properties of neural tissue are affected by certain physiological changes and that these intrinsic optical signals can provide information not available by other means. Most authors attribute the intrinsic optical change to alterations in cell volume and concomitant change in the concentration of the cytosol. In this article we review the literature on intrinsic optical signals, covering both the mechanisms of the optical change and its use in various branches of neurophysiology. We also discuss technical aspects of the technique as used with hippocampal slices, including illumination methods, cameras, experimental methods, and data collection and analysis procedures. Finally we present data from investigations in which we used intrinsic optical signals in hippocampal slices to study the extent of spread of synaptic activation, propagation of spreading depression, extent and severity of the response to hypoxia, and tissue response to osmotic challenges. We conclude that (1) at least two processes generate intrinsic optical signals in hippocampal slices, one of which causes light scattering to change inversely with cell volume and is related to dilution of the cytoplasm, while the other, opposite in sign, may be due to mitochondrial swelling; and (2) the intrinsic optical signal can be a useful tool for spatial mapping of relatively slow events, but is not suitable for study of fast physiological processes.

Animals↗

Implementation of non-invasive brain physiological monitoring concepts.

The paper presents innovative methods and technology for non-invasive intracranial hemodynamics monitoring based on the measurement of brain parenchyma acoustic properties. The clinical investigation of new technology shows the similarity between the invasively recorded intracranial pressure (ICP) and non-invasively recorded intracranial blood volume (IBV) pulse waves, slow waves and slow trends under intensive care unit (ICU) conditions. Also, the applicability of the non-invasive IBV slow wave monitoring technique for cerebrovascular autoregulation non-invasive long-term monitoring is demonstrated by theoretical and experimental studies.

Adult↗

Novel cerebral physiologic monitoring to guide low-flow cerebral perfusion during neonatal aortic arch reconstruction.

OBJECTIVE: This study was undertaken to describe the combined measurement of cerebral blood flow velocity and cerebral oxygen saturation as a guide to bypass flow rate for regional low-flow perfusion during neonatal aortic arch reconstruction. METHODS: Data were prospectively collected from 34 patients undergoing neonatal aortic arch reconstruction with regional low-flow perfusion. Cerebral oxygen saturation and blood flow velocity were measured by near-infrared spectroscopy and transcranial Doppler ultrasonography, respectively, throughout cardiopulmonary bypass. After cooling to 17 degrees C to 22 degrees C, baseline values of cerebral oxygen saturation and blood flow velocity were recorded during full-flow bypass. Regional low-flow perfusion was instituted for aortic arch reconstruction, and bypass flow rate was adjusted to maintain cerebral oxygen saturations and blood flow velocities within 10% of baseline recorded during cold full-flow bypass. Cerebral oxygen saturations and blood flow velocities were recorded again after repair during full-flow hypothermic bypass. Bypass flow during regional low-flow perfusion was recorded, as were arterial pressure and blood gas data. One-way repeated measures analysis of variance was used to determine differences in values during regional low-flow perfusion relative to baseline and after perfusion. RESULTS: A mean bypass flow of 63 mL/(kg x min) was required to maintain cerebral oxygen saturations and blood flow velocities within 10% of baseline. Mean arterial pressure had a poor correlation with the required bypass flow rate (r(2) = 0.006 by linear regression analysis). Fourteen of 34 patients had a cerebral oxygen saturation of 95% during regional low-flow perfusion, placing them at risk for cerebral hyperperfusion if the cerebral oxygen saturation had been used alone to guide bypass flow. Pressure was detected in the umbilical or femoral artery catheter (mean 12 mm Hg) in all patients during regional low-flow perfusion. CONCLUSIONS: Cerebral blood flow velocity, as determined by transcranial Doppler ultrasonography, adds valuable information to cerebral oxygen saturation data in guiding bypass flow during regional low-flow perfusion. Its most important use may be prevention of cerebral hyperperfusion during periods with high near-infrared spectroscopic saturation values.

Analysis of Variance↗

A wireless PDA-based physiological monitoring system for patient transport.

This paper proposes a mobile patient monitoring system, which integrates current personal digital assistant (PDA) technology and wireless local area network (WLAN) technology. At the patient's location, a wireless PDA-based monitor is used to acquire continuously the patient's vital signs, including heart rate, three-lead electrocardiography, and SpO2. Through the WLAN, the patient's biosignals can be transmitted in real-time to a remote central management unit, and authorized medical staffs can access the data and the case history of the patient, either by the central management unit or the wireless devices. A prototype of this system has been developed and implemented. The system has been evaluated by technical verification, clinical test, and user survey. The evaluation of performance yields a high degree of satisfaction (mean = 4.64, standard deviation--SD = 0.53 in a five-point Likert scale) of users who used the PDA-based system for intrahospital transport. The results also show that the wireless PDA model is superior to the currently used monitors both in mobility and in usability, and is, therefore, better suited to patient transport.

Adult↗

Physiological monitoring of stereotactic biopsy.

It is helpful to have direct confirmation during a CT-guided stereotactic procedure that the intended target has been reached without operating under imaging. This can be simply accomplished with readily available equipment by serial monitoring of electrical impedance as a probe is directed to the target because the impedance of hematomas, cysts, and most neoplasms is conspicuously below that of normal brain.

Brain↗