Neutron capture therapy beams at the MIT Research Reactor.

Several neutron beams that could be used for neutron capture therapy at MITR-II are dosimetrically characterized and their suitability for the treatment of glioblastoma multiforme and other types of tumors are described. The types of neutron beams studied are: 1) those filtered by various thicknesses of cadmium, D2O, 6Li, and bismuth; and 2) epithermal beams achieved by filtration with aluminum, sulfur, cadmium, 6Li, and bismuth. Measured dose vs. depth data are presented in polyethylene phantom with references to what can be expected in brain. The results indicate that both types of neutron beams are useful for neutron capture therapy. The first type of neutron beams have good therapeutic advantage depths (approximately 5 cm) and excellent in-phantom ratios of therapeutic dose to background dose. Such beams would be useful for treating tumors located at relatively shallow depths in the brain. On the other hand, the second type of neutron beams have superior therapeutic advantage depths (greater than 6 cm) and good in-phantom therapeutic advantage ratios. Such beams, when used along with bilateral irradiation schemes, would be able to treat tumors at any depth in the brain. Numerical examples of what could be achieved with these beams, using RBEs, fractionated-dose delivery, unilateral, and bilateral irradiation are presented in the paper. Finally, additional plans for further neutron beam development at MITR-II are discussed.

Biomedical Engineering↗

Application of boron-entrapped stealth liposomes to inhibition of growth of tumour cells in the in vivo boron neutron-capture therapy model.

Tumour cell destruction in boron neutron-capture therapy (BNCT) is due to the nuclear reaction between (10)B and thermal neutrons. It is necessary for effective BNCT therapy to accumulate (10)B atoms in the tumour cells. The delivery system consisted of polyethylene-glycol (PEG) binding liposomes (DPPC/cholesterol/DSPC-PEG2000) with an entrapped (10)B-compound and we evaluated the cytotoxic effects of intravenously injected (10)B-PEG-liposomes on human pancreatic carcinoma xenografts in nude mice with thermal neutron irradiation. After thermal neutron irradiation of mice injected with (10)B-PEG-liposomes, growth of AsPC-1 tumours was suppressed relative to controls. Injection of (10)B-PEG-liposomes caused the greatest tumour suppression with thermal neutron irradiation in vivo. These results suggest that intravenous injection of (10)B-PEG-liposomes can increase the retention of (10)B atoms by tumour cells, causing suppression of tumour growth in vivo, after thermal neutron irradiation.

Animals↗

Feasibility study on epithermal neutron field for cyclotron-based boron neutron capture therapy.

To realize the accelerator-based boron neutron capture therapy (BNCT) at the Cyclotron and Radioisotope Center of Tohoku University, the feasibility of a cyclotron-based BNCT was evaluated. This study focuses on optimizing the epithermal neutron field with an energy spectrum and intensity suitable for BNCT for various combinations of neutron-producing reactions and moderator materials. Neutrons emitted at 90 degrees from a thick (stopping-length) Ta target, bombarded by 50 MeV protons of 300 microA beam current, were selected as a neutron source, based on the measurement of angular distributions and neutron energy spectra. As assembly composed of iron, AlF3/Al/6LiF, and lead was chosen as moderators, based on the simulation trials using the MCNPX code. The depth dose distributions in a cylindrical phantom, calculated with the MCNPX code, showed that, within 1 h of therapeutic time, the best moderator assembly, which is 30-cm-thick iron, 39-cm-thick AlF3/Al/6LiF, and 1-cm-thick lead, provides an epithermal neutron flux of 0.7 x 10(9) [n cm(-2) s(-1)]. This results in a tumor dose of 20.9 Gy-eq at a depth of 8 cm in the phantom, which is 6.4 Gy-eq higher than that of the Brookhaven Medical Research Reactor at the equivalent condition of maximum normal tissue tolerance. The beam power of the cyclotron is 15 kW, which is much lower than other accelerator-based BNCT proposals.

Aluminum Compounds↗

Boron neutron capture therapy of primary and metastatic brain tumors.

Boron neutron capture therapy (BNCT) is based on the nuclear reaction that occurs when a stable isotope, boron-10, is irradiated with low energy (0.025 eV) thermal neutrons (nth) to yield alpha (4He) particles and 7Li nuclei (10B+nth-->[11B]-->4He + 7Li + 2.79 MeV). The success of BNCT as a tumoricidal modality is dependent on the delivery of a sufficient quantity of 10B and nth to individual cancer cells to sustain a lethal 10B(n, alpha) 7Li reaction. Boron delivery agents include a variety of compounds, such as the sulfhydryl containing polyhedral borane sodium borocaptate (Na2B12H11SH, [BSH]), boronoporphyrins, boronophenylalanine, carboranyl uridines (CBU), and boronated monoclonal antibodies (MAb). The present review will focus on three delivery systems that currently are under investigation in our laboratories, boronated monoclonal antibodies, carboranyl uridines, and boronophenylalanine. Methodology has been developed to heavily boronate MAb using a precision macromolecule, a "starburst" dendrimer, which can be linked to MAb by means of heterobifunctional reagents. Although the resulting immunoconjugates retain their in vitro immunoreactivity, they lose their in vivo tumor localizing properties and accumulate in the liver. In order to obviate this problem, work is now in progress to produce bispecific MAb, which can simultaneously recognize a tumor-associated antigen and a boronated macromolecule. Boron containing nucleosides are potential vehicles for incorporating boron compounds into nucleic acids of neoplastic cells. For this purpose, carboranyl uridines have been synthesized with the boron moiety on either the pyrimidine base or on the carbohydrate component. Although such structures appear to be avidly taken up and retained by tumor cells in vitro, only the 5-carboranyl-nucleosides are converted biologically to the nucleotide. There is no evidence, however, that the latter are incorporated into nucleic acids. Other carboranyl nucleosides currently are being synthesized that may have better tumor localizing properties. The potential use of boronophenylalanine as a capture agent for the treatment of melanoma metastatic to the brain also is under investigation. A nude rat model has been developed using human melanoma cells that are stereotactically implanted into the brain. BNCT-treated animals have either had prolonged survival times or continue to live compared to control rats that invariably died of their tumors, thereby suggesting therapeutic efficacy.

Animals↗

A novel 10B-enriched carboranyl-containing phthalocyanine as a radio- and photo-sensitising agent for boron neutron capture therapy and photodynamic therapy of tumours: in vitro and in vivo studies.

The synthesis of a Zn(ii)-phthalocyanine derivative bearing four 10B-enriched o-carboranyl units (10B-ZnB4Pc) and its natural isotopic abundance analogue (ZnB4Pc) in the peripheral positions of the tetraazaisoindole macrocycle is presented. The photophysical properties of ZnB4Pc, as tested against model biological systems, were found to be similar with those typical of other photodynamically active porphyrin-type photosensitisers, including a singlet oxygen quantum yield of 0.67. The carboranyl-carrying phthalocyanine was efficiently accumulated by B16F1 melanotic melanoma cells in vitro, appeared to be partitioned in at least some subcellular organelles and, upon red light irradiation, induced extensive cell mortality. Moreover, ZnB4Pc, once i.v.-injected to C57BL/6 mice bearing a subcutaneously transplanted pigmented melanoma, photosensitised an important tumour response, provided that the irradiation at 600-700 nm was performed 3 h after the phthalocyanine administration, when appreciable concentrations of ZnB4Pc were still present in the serum. Analogously, irradiation of the 10B-ZnB4Pc-loaded pigmented melanoma with thermal neutrons 24 h after injection led to a 4 day delay in tumour growth as compared with control untreated mice. These results open the possibility to use one chemical compound as both a photosensitising and a radiosensitising agent for the treatment of tumours by the combined application of photodynamic therapy and boron neutron capture therapy.

Animals↗

Boronated epidermal growth factor as a potential targeting agent for boron neutron capture therapy of brain tumors.

In order for boron neutron capture therapy (BNCT) to be successful, a large number (approximately 10(9)) of 10B atoms must be delivered to each cancer cell in order to sustain a lethal 10B(n, alpha)7Li reaction. The majority of high grade gliomas express an amplified epidermal growth factor receptor (EGFR) gene, and increased numbers of EGFR are found on the cell surface. If a sufficiently large number of 10B atoms could be attached to EGF, the resulting bioconjugates might be useful for targeting brain tumors. In order to accomplish this, we have boronated a fourth-generation starburst dendrimer (SD) using an isocyanato polyhedral borane, Na(CH3)3NB10H8NCO. For conjugation, reactive thiol groups were introduced into the boronated SD using N-succinimidyl 3-(2-pyridyldithio)propionate (SPDP), and EGF was derivatized with m-maleimidobenzoyl-N-hydroxysulfosuccinimide ester (sMBS). Subsequent reaction of thiol groups of derivatized BSD with maleimide groups of derivatized EGF produced stable BSD-EGF bioconjugates containing approximately 960 atoms of boron per molecule of EGF. As determined by electron spectroscopic imaging, the BSD-EGF initially was bound to the cell surface membrane and then was endocytosed, which resulted in accumulation of boron in lysosomes. The favorable in vitro properties of these bioconjugates suggest that they may be useful for the in vivo targeting of EGFR positive brain tumors.

Amino Acid Sequence↗

Performance of sulfhydryl boron hydride in patients with grade III and IV astrocytoma: a basis for boron neutron capture therapy.

This study investigated the rationale of boron neutron capture therapy (BNCT) for the treatment of Grade III and IV astrocytoma. The European Community joint research program on BNCT plans to use sulfhydryl boron hydride (BSH) in clinical trials. The work presented here, examines the performance of BSH in eight patients with Grade III and IV astrocytoma using a measurement technique which precisely correlates the boron uptake with the histology of the tumor and the peritumoral brain. Astrocytomas are exceptionally heterogeneous and spread migrating tumor cells into the surrounding brain. The patients were infused with 50 mg BSH per kilogram of body weight at 12, 18, 24 or 48 hours before surgery. At the time of operation, specimens were obtained of the tumor, skin, muscle, dura, blood, urine, and, when surgically possible, the brain adjacent to tumor. In three patients the intracellular boron distribution was investigated by subcellular fractionation. The blood clearance was biphasic with half-lives of 0.6 and 8.2 hours. After 3 days, approximately 70% of the dose injected was excreted in the urine. The maximum boron concentration in the tumor was 20 ppm, 12 hours after the infusion. The tumor-to-blood ratios ranged between 0.2 and 1.4, with the highest values after 18 to 24 hours. In the brain specimens the boron concentration never exceeded 1 ppm. This work confirms a selective uptake of boron in the tumor compared to the surrounding brain and that boron, to some extent, is incorporated in the tumor cells.

Astrocytoma↗

Fission reactor neutron sources for neutron capture therapy--a critical review.

The status of fission reactor-based neutron beams for neutron capture therapy (NCT) is reviewed critically. Epithermal neutron beams, which are favored for treatment of deep-seated tumors, have been constructed or are under construction at a number of reactors worldwide. Some of the most recently constructed epithermal neutron beams approach the theoretical optimum for beam purity. Of these higher quality beams, at least one is suitable for use in high through-put routine therapy. It is concluded that reactor-based epithermal neutron beams with near optimum characteristics are currently available and more can be constructed at existing reactors. Suitable reactors include relatively low power reactors using the core directly as a source of neutrons or a fission converter if core neutrons are difficult to access. Thermal neutron beams for NCT studies with small animals or for shallow tumor treatments, with near optimum properties have been available at reactors for many years. Additional high quality thermal beams can also be constructed at existing reactors or at new, small reactors. Furthermore, it should be possible to design and construct new low power reactors specifically for NCT, which meet all requirements for routine therapy and which are based on proven and highly safe reactor technology.

Animals↗

Enhancement of a 252Cf-based neutron beam via subcritical multiplication for neutron capture therapy.

Previous studies indicated that an epithermal-neutron beam based on bare 252Cf is not feasible for neutron capture therapy (NCT). It was reported that a clinically useful epithermal-neutron beam requires a minimum of 1.0 g of 252Cf, which is more than twice the US current annual supply. However, it was reasoned that the required quantity of 252Cf could be dramatically reduced when used with a subcritical multiplying assembly (SMA). This reasoning is based on the assumption that the epithermal-neutron beam intensity for NCT is directly proportional to the fission neutron population, and that the neutron multiplying factor of the SMA can be estimated by 1/(1 - k(eff)). We have performed detailed Monte Carlo calculations to investigate the validity of the above reasoning. Our results show that 1/(1 - k(eff)) grossly overestimates the beam enhancement factor for NCT. For example, Monte Carlo calculations predict a beam enhancement factor of 6.0 for an optimized SMA geometry with k(eff) = 0.968. This factor is much less than 31 predicted by 1/(1 - k(eff)). The overestimation is due to the fact that most of the neutrons produced in the SMA are self-shielded, whereas self-shielding is negligible in a bare 252Cf source. Since the beam intensity of a 0.1 g 252Cf with the optimized SMA enhancement is still more than an order of magnitude too low compared to the existing reactor beams, we conclude that the enhancement via an SMA for a 252Cf-based epithermal-neutron beam is inadequate for NCT.

Californium↗

Pharmacokinetics of 10B-p-boronophenylalanine in tumours, skin and blood of melanoma patients: a study of boron neutron capture therapy for malignant melanoma.

To optimize the neutron dose for boron neutron capture therapy (BNCT), the boron-10 (10B) concentration kinetics of 10B-p-boronophenylalanine (BPA) were analysed in 22 melanoma patients with primary or metastatic melanomas who received BPA and subsequently underwent BNCT or surgery. The blood concentration in nine patients receiving 179.7+/-14.9 mg/kg BPA increased with time during intravenous infusion, peaked at the end of administration and decreased thereafter. The peak values at the end of administration were 9.4 2.6 microg 10B/g blood, and half-lives for the initial and second components of the blood clearance were 2.8 and 9.2 h, respectively. Skin concentrations in the 10 patients varied from case to case; however, skin-to-blood ratios were relatively constant at 1.31+/-0.22 during the 6 h after the end of administration. Boron concentrations in the tumours resected from the seven patients who were operated on decreased in parallel to the blood values, the tumour-to-blood ratio being relatively constant at 3.40+/-0.83. The present analytical data of BPA pharmacokinetics support our previous approach for optimizing the timing of irradiation and setting the neutron flux large enough for tumour eradication but still tolerable for normal skin.

Adult↗

Evaluation of useful neutron flux for accelerator boron neutron capture therapy using the 7Li(p,n) reaction.

Accelerator neutron sources for epithermal neutron capture therapy utilising the 7Li(p,n) nuclear reaction are proposed to operate in the range of 1.88 to 2.5 MeV proton energy. Operation with proton energies closer to the reaction threshold decreases neutron yield but allows for smaller reflector and moderator, with less reduction of the epithermal flux, whereas high energies allow thicker targets to be used. The neutron yields for thick lithium targets are estimated in the energy range of 1.881 MeV to 2.5 MeV and useful neutron flux determined. The optimal range of proton energy is found to be 1.89-1.95 MeV, and this is recommended for more detailed studies of neutron transport properties for accelerator BNCT.

Biophysical Phenomena↗

Design of a californium-based epithermal neutron beam for neutron capture therapy.

The potential of the spontaneously fissioning isotope, 252Cf, to provide epithermal neutrons for use in boron neutron capture therapy (BNCT) has been investigated using Monte Carlo simulation. The Monte Carlo code MCNP was used to design an assembly composed of a 26 cm long, 11 cm radius cylindrical D2O moderator followed by a 64 cm long Al filter. Lithium filters are placed between the moderator and the filter and between the Al and the patient. A reflector surrounding the moderator/filter assembly is required in order to maintain adequate therapy flux at the patient position. An ellipsoidal phantom composed of skull- and brain-equivalent material was used to determine the dosimetric effect of this beam. It was found that both advantage depths and advantage ratios compare very favourably with reactor and accelerator epithermal neutron sources. The dose rate obtainable, on the other hand, is 4.1 RBE cGy min-1, based on a very large (1.0 g) source of 252Cf. This dose rate is two to five times lower than those provided by existing reactor beams and can be viewed as a drawback of using 252Cf as a neutron source. Radioisotope sources, however, do offer the advantage of in-hospital installation.

Californium↗

Experimental verification of improved depth-dose distribution using hyper-thermal neutron incidence in neutron capture therapy.

We have proposed the utilization of 'hyper-thermal neutrons' for neutron capture therapy (NCT) from the viewpoint of the improvement in the dose distribution in a human body. In order to verify the improved depth-dose distribution due to hyper-thermal neutron incidence, two experiments were carried out using a test-type hyper-thermal neutron generator at a thermal neutron irradiation field in Kyoto University Reactor (KUR), which is actually utilized for NCT clinical irradiation. From the free-in-air experiment for the spectrum-shift characteristics, it was confirmed that the hyper-thermal neutrons of approximately 860 K at maximum could be obtained by the generator. From the phantom experiment, the improvement effect and the controllability for the depth-dose distribution were confirmed. For example, it was found that the relative neutron depth-dose distribution was about 1 cm improved with the 860 K hyper-thermal neutron incidence, compared to the normal thermal neutron incidence.

Hot Temperature↗

Boron neutron capture therapy of brain tumors: an emerging therapeutic modality.

Boron neutron capture therapy (BNCT) is based on the nuclear reaction that occurs when boron-10, a stable isotope, is irradiated with low-energy thermal neutrons to yield alpha particles and recoiling lithium-7 nuclei. For BNCT to be successful, a large number of 10B atoms must be localized on or preferably within neoplastic cells, and a sufficient number of thermal neutrons must be absorbed by the 10B atoms to sustain a lethal 10B (n, alpha) lithium-7 reaction. There is a growing interest in using BNCT in combination with surgery to treat patients with high-grade gliomas and possibly metastatic brain tumors. The present review covers the biological and radiobiological considerations on which BNCT is based, boron-containing low- and high-molecular weight delivery agents, neutron sources, clinical studies, and future areas of research. Two boron compounds currently are being used clinically, sodium borocaptate and boronophenylalanine, and a number of new delivery agents are under investigation, including boronated porphyrins, nucleosides, amino acids, polyamines, monoclonal and bispecific antibodies, liposomes, and epidermal growth factor. These are discussed, as is optimization of their delivery. Nuclear reactors currently are the only source of neutrons for BNCT, and the fission reaction within the core produces a mixture of lower energy thermal and epithermal neutrons, fast or high-energy neutrons, and gamma-rays. Although thermal neutron beams have been used clinically in Japan to treat patients with brain tumors and cutaneous melanomas, epithermal neutron beams now are being used in the United States and Europe because of their superior tissue-penetrating properties. Currently, there are clinical trials in progress in the United States, Europe, and Japan using a combination of debulking surgery and then BNCT to treat patients with glioblastomas. The American and European studies are Phase I trials using boronophenylalanine and sodium borocaptate, respectively, as capture agents, and the Japanese trial is a Phase II study. Boron compound and neutron dose escalation studies are planned, and these could lead to Phase II and possibly to randomized Phase III clinical trials that should provide data regarding therapeutic efficacy.

Boron Neutron Capture Therapy↗

Mutagenic effect of borocaptate sodium and boronophenylalanine in neutron capture therapy.

PURPOSE: To investigate the mutagenic effect in boron neutron capture therapy (BNCT), Chinese hamster ovary cells were incubated with 10 B-enriched borocaptate sodium (BSH) or para-boronophenylalanine (BPA) before exposure to thermal neutrons, and the occurrence of mutations at the hypoxanthine-guanine phosphoribosyl transferase (HPRT) locus was measured. METHODS AND MATERIALS: BSH or BPA was added to cells 20 h or 2 h before irradiation and removed before irradiation. Cells were irradiated with thermal neutrons. The biologic end point of cell survival was measured by colony formation assay. The mutagenicity was calculated from the mutation frequency at the HPRT locus. RESULTS: The mutagenicity of BSH and BPA was similar to that of 10B boric acid when the cells were irradiated with neutrons at an isosurvival dose after 2-h preincubation. Preincubation with BSH for 20 h, compared with preincubation for just 2 h, had no effect on either cytotoxicity or mutagenicity in BNCT. However, with BPA, 20-h preincubation, compared with 2-h preincubation, caused an increase in the cell killing effect, but a decrease in the mutagenic effect of the BNCT. CONCLUSION: After 20-h incubation, BPA was less mutagenic than BSH. The mutagenic study of electroporated BPA or BSH revealed a reduced mutagenicity. These results suggest that the retention of these boron compounds in the cells causes a more accurate assault on the cell and lessens the chance of misrepair after neutron irradiation.

Animals↗

A fundamental study on hyper-thermal neutrons for neutron capture therapy.

The utilization of hyper-thermal neutrons, which have an energy spectrum with a Maxwellian distribution at a higher temperature than room temperature (300 K), was studied in order to improve the thermal neutron flux distribution at depth in a living body for neutron capture therapy. Simulation calculations were carried out using a Monte Carlo code 'MCNP-V3' in order to investigate the characteristics of hyper-thermal neutrons, i.e. (i) depth dependence of the neutron energy spectrum, and (ii) depth distribution of the reaction rate in a water phantom for materials with 1/v neutron absorption. It is confirmed that hyper-thermal neutron irradiation can improve the thermal neutron flux distribution in the deeper areas in a living body compared with thermal neutron irradiation. When hyper-thermal neutrons with a 3000 K Maxwellian distribution are incident on a body, the reaction rates of 1/v materials such as 14N, 10B etc are about twice that observed for incident thermal neutrons at 300 K, at a depth of 5 cm. The limit of the treatable depth for tumours having 30 ppm 10B is expected to be about 1.5 cm greater by utilizing hyper-thermal neutrons at 3000 K compared with the incidence of thermal neutrons at 300 K.

Brain↗

Boron neutron capture therapy for glioblastoma multiforme using p-boronophenylalanine and epithermal neutrons: trial design and early clinical results.

A Phase I/II clinical trial of boron neutron capture therapy (BNCT) for glioblastoma multiforme is underway using the amino acid analog p-boronophenylalanine (BPA) and the epithermal neutron beam at the Brook-haven Medical Research Reactor. Biodistribution studies were carried out in 18 patients at the time of craniotomy using an i.v. infusion of BPA, solubilized as a fructose complex (BPA-F). There were no toxic effects related to the BPA-F administration at doses of 130, 170, 210, or 250 mg BPA/kg body weight. The tumor/ blood, brain/blood and scalp/blood boron concentration ratios were approximately 3.5:1, 1:1 and 1.5:1, respectively. Ten patients have received BNCT following 2-hr infusions of 250 mg BPA/kg body weight. The average boron concentration in the blood during the irradiation was 13.0 +/- 1.5 micrograms 10B/g. The prescribed maximum dose to normal brain (1 cm3 volume) was 10.5 photon-equivalent Gy (Gy-Eq). Estimated maximum and minimum doses (mean +/- sd, n = 10) to the tumor volume were 52.6 +/- 4.9 Gy-Eq (range: 64.4-47.6) and 25.2 +/- 4.2 Gy-Eq (range: 32.3-20.0), respectively). The estimated minimum dose to the target volume (tumor +2 cm margin) was 12.3 +/- 2.7 Gy-Eq (range: 16.2-7.8). There were no adverse effects on normal brain. The scalp showed mild erythema, followed by epilation in the 8 cm diameter field. Four patients developed recurrent tumor, apparently in the lower dose (deeper) regions of the target volume, at post-BNCT intervals of 7,5,3.5 and 3 months, respectively. The remaining patients have had less than 4 months of post-BNCT follow-up. BNCT, at this starting dose level, appears safe. Plans are underway to begin the dose escalation phase of this protocol.

Adult↗