PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PICRATES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

On the oscillatory phenomenon in an oil/water interface.

A simple theoretical model is presented for simulating the self-sustained oscillations of electric potential and pH at an oil/water interface appearing in a two-phase system composed of 2-nitropropane solution containing picrate acid and an aqueous solution of cetyltrimethylammonium bromide. In the present model, a well-known condition necessary for the occurrence of self-sustained oscillations, i.e., the presence of a positive feedback process far from equilibrium, is taken into account in a set of kinetic equations to describe simplified characters of the following two processes: (i) a cooperative formation of ion pair complexes at the interface, and (ii) supply of picrate anions and cetyltrimethylammonium cations to the interface accompanied by release of ion pair complexes to the organic phase. The numerical solutions of the present equations are shown to reproduce fairly well the characteristic properties of the oscillation of electric potential and pH such as wave forms and frequencies.

Journal Article↗

Rapid determination of benzalkonium chloride in pharmaceutical preparations with flow injection liquid-liquid extraction.

Benzalkonium chloride was assayed by on-line extraction of the benzalkonium ion with picrate to chloroform. The absorbance of picrate was measured. The extractions were performed with a home-made flow injection extraction unit. Calibration curves (1.5-180 x 10(-4)% w/v) were straight lines (r = 0.9993) and the relative standard deviation of a series of injections was less than or equal to 2%. Pharmaceutical benzalkonium preparations, containing xylometazoline, timolol, phenylephrine or carbachol could also be assayed. The method was compared with a modified HPLC assay.

Benzalkonium Compounds↗

Rapid and selective UV spectrophotometric and RP-HPLC methods for dissolution studies of oxybutynin immediate-release and controlled-release formulations.

A new UV spectrophotometric method and a reversed-phase HPLC method were developed for quantitative evaluation of oxybutynin hydrochloride (OXB) formulations. Determination of OXB by UV spectroscopic method was based on complexation of OXB with picric acid to form picrate, which was extracted to chloroform. The picrate complex showed quantifiable absorbance at 344nm. Chromatography was carried out at 25 degrees C on a 4.6mm x 250mm 5microm cyano column that contained USP packing L10 with water:methanol:acetonitrile::48:12:40 (v/v), as mobile phase. UV detector was set at 203nm. Both methods were found to be selective, linear, accurate and precise in the specified ranges. The LOD and LOQ of HPLC method were 0.5 and 1.65microg/ml, respectively. Intra-day and inter-day variability for both methods were <2% RSD. These methods were successfully used for quantification of OXB in drug-release studies from immediate-release tablets and controlled-release (CR) formulations.

Chemistry, Pharmaceutical↗

Impact of serum creatinine measurement error on dose adjustment in renal failure.

BACKGROUND: Doses of renally eliminated drugs should be adjusted according to kidney function to prevent adverse drug events and cost. Dose adjustment can be based on serum creatinine level, subsequent creatinine clearance estimation, and dosage calculation with consideration of the renal elimination properties of the respective compound. OBJECTIVE: Our objective was to quantify the impact and relevance of serum creatinine measurement error on dose adjustment in renal failure. METHODS: We analyzed 27914 measurements from external quality assessment surveys of 1878 German laboratories that used a kinetic alkaline picrate (69% of results) or an enzymatic method (25%) for creatinine determination. Linear models were fit for both methods combined and separately. On the basis of 95% confidence intervals (CIs) for creatinine values, 95% CIs for drug dosing were calculated. RESULTS: The 95% CI for a measured serum creatinine value was 0.80. Measured value < Reference method value < 1.28. Measured value for the kinetic alkaline picrate method and 0.87. Measured value < Reference method value < 1.21. Measured value for the enzymatic method. Applied to a data set of 6.5 million simulated patients with all possible combinations of characteristics relevant for drug dosing, the dosing error caused by serum creatinine measurement error did not exceed 25% in patients with creatinine clearance estimates lower than 50 mL/min according to the Cockcroft-Gault equation. For drugs completely eliminated by the kidneys in active form, the dosing error was up to 6-fold smaller than that which would occur if doses were not adjusted. CONCLUSION: The serum creatinine measurement error of current laboratory methods is small and is comparable to other errors influencing dose adjustment.

Aging↗

High-speed ion-pair partition chromatography in pharmaceutical analysis.

Ion-pair chromatography offers attractive possibilities in pharmaceutical analysis. The specificity of the separation systems can be varied over a wide range by appropriate selection of the stationary phase. The choice of a suitable counter-ion can also drastically improve the detection limit, permitting the determination of drug substances in low dosage and possibly of by-products or breakdown products. Ion-pair chromatography of tropane and ergot alkaloids has been investigated using picrate as counter-ion. Alumina, Kieselguhr and various grades of silica gel have been tested as supports. Partition properties studied in a batch procedure have been compared with the actual chromatographic conditions. Columns (10 cm) filled with silical gel (particle size, 5 mum; pore size, 1000 A) show the best performance in the separation of hyoscyamine, scopolamine and ergotamine as picrate ion-pairs. Close control of pH and temperature is essential for reproducible separations. Improvements in detection limits between 100 and 300 times have been observed with these systems. Ion-pair extractions of these alkaloids from dosage forms can be used for sample preparation prior to injection on the the column. This provides an added degree of selectivity and sensitivity.

Atropine↗

Determination of incorporated amounts of poly(ethylene glycol)-derivatized lipids in liposomes for the physicochemical characterization of stealth liposomes.

We describe a method for determining incorporated amounts of poly(ethylene glycol) (PEG)-derivatized lipids in liposomes for the physicochemical characterization of PEG-coated liposomes. This method is based on the spectrophotometric determination of complexes of polyethers with sodium ions after their extraction as picrates into 1,2-dichloroethane, developed by Favretto for measuring levels of polyoxyethylene alkylphenyl-ether non-ionic surfactants in waste water. The same assay was applied to the estimation of PEG-derivatized lipids in liposomes and percent incorporation of PEG-derivatized lipids into liposomes was successfully determined. To prevent the interference from liposomal lipids other than PEG-derivatized lipids in this assay, liposomal samples were diluted at least to a concentration of less than 0.2 mM. The percent incorporation of PEG-lipids varied, depending on the molecular weight of PEG and anchor acyl chain length in PEG-lipids and it was suggested that the percent incorporation of PEG-lipids into liposomes would be a good parameter of quality control of PEG-liposomes in manufacturing facility and the picrate method used in the present study allows for the determination of this parameter without the need for hazardous radioisotopes.

Calibration↗

Enhanced selectivity for actinides over lanthanides with CMPO ligands secured to a C(3)-symmetric triphenoxymethane platform.

A ligand system containing three preorganized carbamoylmethylphosphine oxide (CMPO) moieties anchored onto a rigid C(3)-symmetric triphenoxymethane platform has been developed for facile metal complexation and subsequent extraction from aqueous acidic nuclear waste streams. Intended to mimic the 3:1 CMPO-actinide stoichiometry of the extracted species in the TRUEX nuclear waste treatment process, the CMPO arms on this ligand are oriented such that all three CMPO moieties can cooperatively bind a metal ion. Extractions of simulated nuclear waste streams (10(-4) M metal in 1 M nitric acid) with solutions of this ligand in methylene chloride (10(-3) M) reveal a high affinity for the actinide thorium and a very low, but constant, affinity for the lanthanides across the series. Thorium and five lanthanide (lanthanum, cerium, neodymium, europium, and ytterbium) nitrate complexes of this ligand have been synthesized and fully characterized by X-ray crystallography, (1)H and (31)P NMR spectra, and FT-ICR-MS to elucidate the mechanism of this unique actinide selectivity. All six oxygen donors from the three CMPO arms of the ligand and one or two nitrate counterions coordinate these metals to afford 2+ cationic complexes in every case. Because of the large size of the ligand, both the thorium and lanthanide complexes present similarly charged and sized surfaces to the extraction solvents, but the thorium complex is extracted quantitatively over the lanthanide complexes. A possible rationale for this extraction behavior difference is presented and further illustrated by the extraction properties of this ligand system for the alkali metals (lithium, sodium, potassium, rubidium, and cesium) as picrate salts and by the solid- and solution-state structures of its lithium picrate complex.

Journal Article↗

Anion partitioning and ion-pairing behavior of anions in the extraction of cesium salts by 4,5' '-Bis(tert-octylbenzo)dibenzo-24-crown-8 in 1,2-dichloroethane.

A systematic study of anion partitioning and ion pairing was performed for an extraction of individual cesium salts into 1,2-dichloroethane (1,2-DCE) using 4,5' '-bis(tert-octylbenzo)dibenzo-24-crown-8 as the cesium receptor. Equilibrium constants corresponding to the extraction of ion pairs and dissociated ions, formation of the 1:1 cesium/crown complex (confirmed by electrospray mass spectrometry), and dissociation of the ion pairs in water-saturated 1,2-DCE at 25 degrees C were obtained from equilibrium modeling using the SXLSQI program. The standard Gibbs energy of partitioning between water and water-saturated 1,2-DCE was determined for picrate, permanganate, trifluoromethanesulfonate, methanesulfonate, trifluoroacetate, and acetate anions. The dissociation of the organic-phase complex ion pair [Cs(4,4' '-bis(tert-octylbenzo)dibenzo-24-crown-8]+NO3- observed in the extraction experiments was shown to be consistent with the dissociation constant determined independently by conductance measurements. As attributed to the large effective radius of the complex cation, the evident anion discrimination due to ion pairing in the 1,2-DCE phase was relatively small, by comparison only a tenth of the discrimination exhibited by the anion partitioning. Only chloride and picrate exhibit evidence for significantly greater-than-expected ion-pairing tendency. These results provide insight into the inclusion properties of the clefts formed by opposing arene rings of the crown ether upon encapsulation of the Cs+ ion, whose weak anion recognition likely reflects the preferential inclusion of 1,2-DCE molecules in the clefts. Observed anion extraction selectivity in this system, which may be ascribed predominantly to solvent-induced Hofmeister bias selectivity toward large charge-diffuse anions, was nearly the same whether cesium salts were extracted as dissociated ions or ion pairs.

Journal Article↗

5-Organyl-5-phosphaspiro[4.4]nonanes: a contribution to the structural chemistry of spirocyclic tetraalkylphosphonium salts and pentaalkylphosphoranes.

Spirocyclic phosphonium salts of the type [(CH(2))(4)P(CH(2))(4)](+) X(-) with X = I(3) (1a), I (1b), picrate (1c), benzoate (1d), and Cl (1e) were prepared from 1,4-diiodobutane and elemental phosphorus followed by metathesis reactions. The crystal structures of 1b and 1c and of 1d(H(2)O) have been determined by X-ray diffraction methods. In the cations of these salts the phosphorus atoms are shared by two five-membered rings in envelop conformations. In the picrate 1c the cations show an unsymmetrical ring folding pattern (point group C(1)), while the geometry of the cations of the iodide 1b and the benzoate hydrate [1d(H(2)O)] approaches the symmetry of point group C(2). These structures can be taken as models for the as yet unknown molecular geometries of the corresponding hydrocarbon (CH(2))(4)C(CH(2))(4) and silane (CH(2))(4)Si(CH(2))(4). Treatment of 1e with organolithium reagents RLi affords spirocyclic pentaorganophosphoranes RP[(CH(2))(4)](2) with R = Me, Et, n-Bu, Vi, and Ph (2a-e) in good (R = Me, Et, n-Bu) to low yields (R = Vi, Ph). The products are isolated as colorless liquids, of which only 2a, 2b, and 2d can be distilled without decomposition. Single crystals of 2a were obtained by low-temperature in situ crystal growth. The molecule has a trigonal bipyramidal configuration with the methyl group in an equatorial position and the two five-membered rings spanning axial/equatorial positions of the polyhedron. Deviations from the standard trigonal bipyramidal geometry are small. The compounds 2a-e are fluctional in solution as demonstrated by NMR spectroscopy.

Journal Article↗

Conformational studies of muscarone analogues: X-ray analysis and molecular mechanics calculations.

The X-ray structure of muscarone analogues 3 and 4 was determined and compared with that of muscarone (1, iodide and picrate salts), muscarine 2, dioxolane 5, oxathiolane 6, and tetrahydrofuran 7. In order to better define the pharmacological stereoselectivity of muscarone, the conformational profiles of compounds 1, 2, 3, and 5 were analyzed using Allinger's MM2(85) program or, in the case of 4, by 1H NMR spectroscopy. The conformation of the ring in 1 proved similar to that of the other derivatives. MM2 calculations predicted a preferred gauche arrangement of the side chain for 1 and its analogues; such an arrangement was also observed in the solid state of muscarone picrate. Thus, the antiperiplanar arrangement reported for crystalline muscarone iodide appears to be due to crystallographic packing forces. As a consequence, the rationalization of the pharmacological profile of 1 based on the antiperiplanar arrangement is now highly questionable. The lack of stereoselectivity of 4 can be attributed to the absence of a stereocenter at C-2 whereas, in our opinion, there are currently no sound explanations for the low values of eudismic ratios for the muscarone enantiomers.

Molecular Conformation↗

Anion allosteric effect in the recognition of tetramethylammonium salts by calix[4]arene cone conformers.

Rigid calix[4]arene cone conformers, which are efficient receptors for quaternary ammonium salts, are usually obtained through the functionalization of their lower rim with suitable groups. Using flexible cone conformer of calix[4]arene, bearing four 4-hydroxybenzyl groups as cooperative and rigidifying structural elements at the upper rim of the calix, which act as anion binding groups, a new heteroditopic cavitand, 7, was synthesized. Whereas the tetramethoxy derivative 8 does not show any complexing ability, its tetrahydroxy analogue 7 recognizes tetramethylammonium salts with high efficiency. The binding abilities of this new receptor toward a series of tetramethylammonium salts (tosylate, chloride, acetate, trifluoroacetate, and picrate) have been investigated in CDCl(3) solution and compared to the monotopic and rigidified, through the lower rim, cone biscrown-3-calix[4]arene 9. The results obtained confirmed that in CDCl(3) ion pairing strongly affects binding. In particular, the rigid monotopic receptor 9 experiences good efficiency toward tetramethylammonium salts having anions with low ion-pairing ability such as trifluoroacetate or picrate. On the contrary, for the new heteroditopic cavitand 7, a reverse order of efficiency was found. In the latter case a different complexation mode was hypothesized in which the tetramethylammonium cation is deeply entrapped into the host cavity and its counteranion participates to the recognition process by coordination via hydrogen bonding by the four OH groups. To further support the role of the anion in the recognition process, a "dual host" approach, employing 7 or 9 in the presence of a specific receptor for chloride anion (10), was utilized. Molecular modeling studies confirmed that in the complexes formed by 7 and TMA salts the counteranion is involved in hydrogen bonding with the host OH groups and that the guests are bound as ligand-separated ion pairs.

Allosteric Regulation↗

Synthesis, conformation, and complexation of novel 25,26,27,28- tetrahydroxy-5,11:17,23-bis[[2,2'-thioxydi(o-phenylene)dithioxy]- diphenylthio]calix[4]arene.

Calix[4]arenes 1a,b having an electron-donating group, i.e., OH and OMe, at the lower rim reacted with thianthrene cation radical perchlorate in CH3CN at room temperature to give the corresponding thianthrenium perchlorates 3a,b in excellent yields. Treatment of 3a,b comprising a mixture of conformational isomers with NaSH.xH2O in DMF at reflux afforded the sulfur-containing cyclized compounds 4a,b, respectively. Compound 4a having a cone conformation consisted of two conformational isomers in a ratio of 0.077:1. Temperature-dependent 1H NMR study in DMF showed that conformational isomerization between the two isomers occurred with energy barriers of 14.97 and 14.10 kcal/mol at 100 and 110 degrees C, respectively. The Jobs plot of 4a against Ag+ picrate indicated that compound 4a strongly produced a 1:2 complex with Ag+ ions. Molecular mechanics calculations indicated that the conformation of the energy-minimized 4a-2Ag+ picrate complex had two crushed pyramidal geometries made up of Ag+ ion and four sulfur atoms, i.e., S1, S2, S4, S5 and S6, S7, S9, S10, respectively.

Journal Article↗

Silver(I) complexation of linked 2,2'-dipyridylamine derivatives. Synthetic, solvent extraction, membrane transport and X-ray structural studies.

Synthesis of the 2,2'-dipyridylamine derivatives di-2-pyridylaminomethylbenzene 1, 1,2-bis(di-2-pyridylaminomethyl)benzene 2, 1,3-bis(di-2-pyridylaminomethyl)benzene 3, 2,6-bis(di-2-pyridylaminomethyl)pyridine 4, 1,4-bis(di-2-pyridylaminomethyl)benzene 5, and 1,3,5-tris(di-2-pyridylaminomethyl)benzene 6 are reported together with the single-crystal X-ray structures of 2, 3, and 5. Reaction of individual salts of the type AgX (where X = NO(3)(-), PF(6)(-), ClO(4)(-), or BF(4)(-)) with the above ligands has led to the isolation of thirteen Ag(I) complexes, nine of which have also been characterised by X-ray diffraction. In part, the inherent flexibility of the respective ligands has resulted in the adoption of a range of coordination arrangements. A series of liquid-liquid (H(2)O/CHCl(3)) extraction experiments of Ag(I) with varying concentrations of 1-6 in the organic phase have been undertaken, with the counter ion in the aqueous phase being respectively picrate, perchlorate and nitrate. In general, extraction efficiencies for a given ionophore followed the Hofmeister order of picrate > perchlorate > nitrate; in each case the tris-dpa derivative 6 acting as the most efficient extractant of the six systems investigated. Competitive seven-metal bulk membrane transport experiments (H(2)O/CHCl(3)/H(2)O) employing the above ligands as the ionophore in the organic phase and equimolar concentrations of Co(II), Ni(II), Zn(II), Cu(II), Cd(II), Pb(II) and Ag(I) in the aqueous source phase were also undertaken, with transport occurring against a pH gradient. Under the conditions employed 1 and 5 yielded negligible transport of any of the metals present in the source phase while sole transport selectivity for Ag(I) was observed for 2-4 and 6.

Journal Article↗

The influence of ketoacids on plasma creatinine assays in diabetic ketoacidosis.

OBJECTIVE: Analysis of the interference of ketoacids on various routine plasma creatinine assays during a clinical episode of diabetic ketoacidosis (DKA). DESIGN: Observational study. Blood samples were drawn before, during and after standard in-hospital treatment. Plasma creatinine was measured with two dissimilar enzymatic assays (creatininase PAP + and creatinine iminohydrolase Serapak), a kinetic alkaline picrate method (Jaffé) and a high-performance liquid chromatography (HPLC) procedure. Acetoacetate and beta-hydroxybutyrate were analysed by enzymatic methods. SETTING: Department of Medicine, University Hospital. SUBJECTS: Nine patients who experienced 10 episodes of DKA. MAIN OUTCOME MEASURES: Agreement of the routine plasma creatinine assays with HPLC and analysis of possible interferents. RESULTS: At presentation, the Jaffé assay gave falsely high values of plasma creatinine (median 99 micromol L(-1)), in contrast to the PAP+ (median 60.5 micromol L(-1)) and HPLC assays (median 67.5 micromol L(-1)). This positive error decreased during treatment. This was due to a decrease in acetoacetate, as the positive error by the Jaffé method correlated with the acetoacetate concentration (r = 0.79, P < 0.0001). In the multiple regression analysis, beta-hydroxybutyrate caused no additional interference by the Jaffé assay, confirmed by in vitro experiments. Analysis of agreement showed that the difference between PAP+ and HPLC creatinine was -4.6 +/- 3.0 micromol L(-1) (mean +/- SD), and 2.0 +/- 5.3 micromol L(-1) between Serapak and HPLC. This was statistically significant, but clinically negligible. CONCLUSION: Acetoacetate caused severe interference of the alkaline picrate (Jaffé) assay, which might influence therapeutic decisions at the start of diabetic ketoacidosis. Enzymatic assays lack this interference.

Adult↗

Elimination of bilirubin interference in creatinine assays by routine techniques: comparisons with a high performance liquid chromatography method.

The aim of this study was to find a method for creatinine analysis unaffected by jaundice by comparing four different methods with high performance liquid chromatography (HPLC) as a reference method. The methods investigated were Kodak DTSC single slide, Boehringer alkaline picrate with and without blank correction and a Boehringer enzymatic method, the last three using the Hitachi 737 analyser. HPLC results were compared with the results of the methods studied. In addition, graphs plotting the difference from the HPLC result against the bilirubin concentration were made; the ideal method would yield a slope and intercept of zero. While all methods showed a positive bias compared with HPLC, the Kodak slide and the Boehringer alkaline picrate with blank correction methods eliminated bilirubin interference and we have changed to the latter method as a consequence of this work.

Artifacts↗

Candidate reference method for determining creatinine in serum: method development and interlaboratory validation.

We describe a "high-performance" liquid chromatographic (HPLC) method for accurately determining creatinine in serum. After prechromatographic precipitation of protein, we performed isocratic ion-exchange chromatography with ultraviolet detection (234 nm). Analytical results showed linearity up to 1770 mumol/L, a detection limit of 22 mumol/L, an average analytical recovery of 101%, and a CV ranging from 3% to 11%. We used certified human serum (National Institute of Standards and Technology), and additional lyophilized serum pools also assayed by definitive isotope-dilution mass spectrometry, to validate the accuracy of the HPLC method. In addition, the isocratic HPLC results showed close agreement with those obtained with a step-gradient HPLC method. We also compared the isocratic HPLC method with alkaline picrate and enzymatic methods. Our findings with samples from nonuremic, uremic, and diabetic ketoacidotic patients confirmed the positive bias previously reported with the alkaline picrate method. Interlaboratory transferability of the method was demonstrated with various commercial instruments and analytical columns. We evaluated column stability and possible interference from endogenous or exogenous compounds. On the basis of our analytical findings, we recommend the isocratic HPLC method as a candidate Reference Method for determining creatinine in serum.

Chemistry, Clinical↗

[A kinetic method of determining creatinine using the Jaffé reaction].

The authors suggest a kinetic method for measuring the blood serum and urine creatinine by Jaffe's test. The method is highly specific, requires little biologic material, and rules out the deproteinization procedure. The specificity of the measurement is effected by selecting the period of time when it is creatinine that reacts with alkaline picrate. A thorough selection of the reaction mixture components and of the order of their addition helps minimize the interference of the substances reacting with alkaline picrate during the same period. The method is adapted to biochemical analyzers.

Creatinine↗

Accuracy of creatinine results reported by participants in the CAP Chemistry Survey Program.

This report summarizes the creatinine data reported by over 6,000 participants in the 1982 to 1983 College of American Pathologists Chemistry Survey Program. Participants analyzed lyophilized serum samples on a quarterly basis. The most widely used methods employed the kinetic alkaline picrate reaction. Selected samples also were analyzed at the National Bureau of Standards using an isotope dilution-mass spectrometry definitive method. The participant mean results of each method principle group showed positive biases to the definitive values. The kinetic alkaline picrate and enzymatic method groups had the least biases to the definitive values. Excellent correlations between these two method groups and the definitive values were demonstrated. The consensus mean values of these two method groups would provide reliable target values for creatinine in survey samples. Interlaboratory precision improved significantly in each method group as the creatinine concentration increased.

Creatine Kinase↗