At least 145 records · Page 8Linked to original sources

The study of TSP, PM(2.5-10) and PM2.5 during Taiwan Chi-Chi Earthquake in the traffic site of central Taiwan, Taichung.

Ambient particle concentration was taken on the traffic sampling site over the Chung-Chi Road over bridge (CCROB) in front of Hungkuang Institute of Technology (HKIT). The sampling time was from August 1999 to December 1999. During the sampling period, Taiwan's biggest earthquake in more than a century registered 7.3 on the Richter scale (Taiwan Chi-Chi Earthquake). Besides, there were more than 20,000 aftershocks that followed the Taiwan Chi-Chi Earthquake within three months. Thus, the PM2.5, PM(2.5-10) particle concentrations were also collected then and compared with total suspended particle (TSP) in this study. The average PM(2.5-10), PM2.5 and TSP concentrations are 24.6, 58.0 and 106 microg/m3, respectively, after the Taiwan Chi-Chi Earthquake. The average TSP concentrations before and after Taiwan Chi-Chi Earthquake were 70 and 127 microg/m3, respectively. It is clearly shown that the average concentration of TSP after Taiwan Chi-Chi Earthquake was about 1.8 times as that of TSP concentration before Taiwan Chi-Chi Earthquake in the traffic site of central Taiwan. And the ratios of PM2.5/PM(2.5-10), PM2.5/PM10 and PM2.5/TSP are 2.2%, 67.2%, 38.9%, respectively. The results also indicated about Chi-Chi fine particle concentration (PM25) and the TSP increases in the traffic site of central Taiwan after Taiwan Chi-Chi Earthquake.

Air Pollutants↗

Source apportionment of PM2.5 at an urban IMPROVE site in Seattle, Washington.

The multivariate receptor models Positive Matrix Factorization (PMF) and Unmix were used along with the EPA's Chemical Mass Balance model to deduce the sources of PM2.5 at a centrally located urban site in Seattle, WA. A total of 289 filter samples were obtained with an IMPROVE sampler from 1996 through 1999 and were analyzed for 31 particulate elements including temperature-resolved fractions of the particulate organic and elemental carbon. All three receptor models predicted that the major sources of PM2.5 were vegetative burning (including wood stoves), mobile sources, and secondary particle formation with lesser contributions from resuspended soil and sea spray. The PMF and Unmix models were able to resolve a fuel oil combustion source as well as distinguish between diesel emissions and other mobile sources. In addition, the average source contribution estimates via PMF and Unmix agreed well with an existing emissions inventory. Using the temperature-resolved organic and elemental carbon fractions provided in the IMPROVE protocol, rather than the total organic and elemental carbon, allowed the Unmix model to separate diesel from other mobile sources. The PMF model was able to do this without the additional carbon species, relying on selected trace elements to distinguish the various combustion sources.

Air Pollutants↗

Nonderivatization analytical method of fatty acids and cis pinonic acid and its application in ambient PM2.5 aerosols in the greater Vancouver area in Canada.

A nonderivatization analytical method has been developed to analyze C6-C20 fatty acids and cis-pinonic acid on a GC/ FID and a GC/MSD using a polar DB-FFAP capillary column. On the GC/FID, the response was highly linear over concentration ranges >2 orders of magnitude (R2 = 1.00). Using a mixed solvent of dichloromethane (DCM): methanol (3:1, v/v) and an extraction temperature of 40 degrees C, the method recoveries of the acids from spiked filters were 81-115% based on deuterated surrogates, and the relative standard deviations were <12%. The recoveries were mainly controlled by the extraction temperature. At 40 degrees C the acids in sample extracts were stable for at least 12 months, while at 80 degrees C, unintended esterization of the acids by methanol was found that reduces their stability in the sample extracts. The analysis of the acids in PM2.5 samples from NIST using this nonderivatization method showed that the efficiency and accuracy were comparable to the derivatization method. Compared with existing derivatization methods, the method is accurate and sensitive, yet simple to use. This method was applied to PM2.5 ambient aerosols collected from a forest site and at a traffic tunnel outlet in the greater Vancouver area in Canada. Total fatty acids (sum of C6-C20) in the aerosols were measured as 20.2-138.7 ng/m3 at the forest site and 100.2-264.6 ng/m3 at the tunnel site. The cis-pinonic acid concentrations were 1.6-44.2 ng/m3 in the forest and from below detection to 6.5 ng/m3 at the tunnel outlet.

Air Pollutants↗

Investigation of the microcharacteristics of PM2.5 in residual oil fly ash by analytical transmission electron microscopy.

Atmospheric emissions from combustion of residual oils often consist of carbonaceous material and metal compounds, both of which are of concern for health and environmental issues. In this study, particulate matter fractions with aerodynamic diameters nominally less than 2.5 microm (PM2.5) in two residual oil fly ash (ROFA) samples generated from combustion experiments were investigated by analytical transmission electron microscopy (TEM) techniques, including energy-dispersive X-ray spectroscopy, selected area electron diffraction (SAED), high-resolution TEM, and electron energy loss spectroscopy (EELS). Carbonaceous particles, which dominate both samples, exist in two distinctive forms: as soot aggregates with spherical primary particles of size 10-80 nm that exhibit a concentric arrangement of graphitic layers around the particle center and as larger spherical or irregular-shaped porous residual char particles of size 1-20 microm that usually have anisotropic microtextures and contain organic sulfur species. Such carbon-rich particles were often observed to be coated with inorganic species, notably transition metals (V, Ni, Fe, Zn) in the form of sulfates, oxides, vanadates, and phosphates. In this respect, they therefore differ from similar carbonaceous particles generated in combustion of diesel fuels that lack significant inorganic species. Crystalline phases of vanadium, nickel, and iron oxides and multi-element oxides were identified by the SAED technique. The valence state of V in some V-rich oxide particles probed by EELS was found to vary from +2 to +5. Individual transition metal sulfate, oxide, and phosphate particles are typically compositionally complex, containing multiple metallic elements. These microcharacteristics of individual PM2.5 particles revealed by electron microscopy techniques should be important parameters to include in future toxicological investigations of ROFA PM.

Air Pollutants↗

Distributions of PM2.5 source strengths for cooking from the Research Triangle Park particulate matter panel study.

Emission rates, decay rates, and cooking durations are reported from continuous PM2.5 (particulate matter less than 2.5 microm) concentrations measured using personal DataRam nephelometers (1-min time resolution) from the Research Triangle Park (RTP) PM panel study. The study (n = 37 participants) included monitoring for 7 consecutive days in each of four consecutive seasons (summer 2000 through spring 2001). Cooking episodes (n = 411) were selected using time-activity diaries and criteria for cooking event duration, peak concentration level, and decay curve quality. Averaged across all cooking events, mean source strengths were 36 mg/min (median = 12 mg/min), mean decay rates were 0.27 h(-1) (0.17 h(-1)), and mean cooking durations were 11 min (7 min). Cooking events were further separated into one of seven categories representing cooking method: burned food (oven cooking, toaster, or stovetop cooking), grilling, microwave, toaster oven, frying, oven cooking, and stovetop cooking. The highest mean source strengths were identified from burned food (mean = 470 mg/min), grilling (173 mg/min), and frying (60 mg/ min); differences between both burned food and grilling compared with all remaining cooking methods were statistically significant. Source strengths, decay rates, and cooking durations were also compared by season and typical meal times (8:00 a.m., 12:00 p.m., and 6:00 p.m.); differences were generally not statistically significant for these cases. Mean source strengths using electric appliances were typically a factor of 2 greater than those using gas appliances for identical cooking methods (frying, oven cooking, or stovetop cooking), although in all cases the difference was not statistically significant. Distributions of source strengths and decay rates for cooking events were also compared among study subjects to assess both within- and between-subject variability. Each subject's distribution of source strengths during the study tended to be either lower than the overall study average (and with lower variability) or higher than the overall study average (and with higher variability). No relationships could be found between source strength and either subject characteristics (age, gender, employment status) or home characteristic (daily air exchange rate). The large number of cooking events and the broad range of cooking activities included in this analysis makes the reported distributions of PM2.5 source strengths useful for probabilistic exposure modeling even though the study population was limited.

Air Pollutants↗

Analysis of secondary organic aerosol compounds from the photooxidation of d-limonene in the presence of NOx and their detection in ambient PM2.5.

Chemical analysis of secondary organic aerosol (SOA) from the photooxidation of a d-limonene/NOx/air mixture was carried out. SOA, generated in a smog chamber, was collected on Zefluor filters. To determine the structural characteristics of the compounds, the filter samples were solvent extracted and derivatized using analytical techniques that characterize functional groups contained in the compound: BF3-methanol derivatization was used for carboxylic groups, BSTFA for acidic and nonacidic hydroxyl groups, and PFBHA for ketone and aldehyde groups. The resulting derivative compounds were analyzed by GC-MS in the methane Cl and El modes. GC-MS analysis showed the occurrence of 103 oxygenated organic compounds in the filter extracts, 28 of which were identified. The major components include five tracer compounds previously identified from the photooxidation of alpha-pinene/NOx or beta-pinene/NOx systems, C4-C6 linear dicarboxylic acids, ketolimononaldehyde, limonic acid, and ketolimonic acid. Time profiles, yields, and proposed reaction schemes are provided for selected compounds. The laboratory SOA yield was 0.51 at a SOA concentration of 1470 microg m(-3). To determine the contributions of SOA products from d-limonene to ambient PM2.5, an analysis was performed for eight ambient PM2.5 samples collected in the southeastern United States in summer 2003. GC-MS analysis showed the occurrence of 21 d-limonene SOA compounds, indicating the impact of d-limonene on the regional aerosol burden. Based on our analysis, two compounds (nos. 55 and 69), not observed from the photooxidation of alpha-pinene or beta-pinene, are candidate tracers for d-limonene in atmospheric particulate matter.

Aerosols↗

Design and validation of a high-flow personal sampler for PM2.5.

A high-flow personal sampler (HFPS) for airborne particulate matter has been developed and fully characterised, and validation tests have been carried out. The sampler is a low-cost gravimetric instrument designed to collect particulate matter with a 50% cut point at 2.5 microm aerodynamic equivalent diameter (PM2.5), where size selection is achieved by the use of porous polyurethane foam. Development of a porous foam selector was chosen over a cyclone or impactor due to the lightweight, low-cost, and compact design that could be achieved. The sampler flow rate of 16 1/min is achieved using a portable, flow-controlled pump; this flow rate is far higher than that of conventional personal samplers and the HFPS can therefore be used for personal sampling in the ambient environment over short sampling periods of much less than 24 h. The HFPS is currently being used in a study of particle exposure of urban transport users (cyclists, car drivers, bus and Underground rail passengers) where personal sampling over short time periods representing typical commuter journey times is required. The HFPS was fully characterised in chamber studies with a TSI aerodynamic particle sizer (APS). The sampler was then validated against a co-located U.S. EPA Federal Reference PM2.5 Well Impactor Ninety Six (WINS) and a KTL cyclone, and parallel testing was performed. Initial testing showed some penetration of particles through the porous foam structure; applying an oil coating to the foam eliminated this problem. Chamber testing was carried out on a number of different selector prototypes, with the final design giving a 50% penetration diameter (i.e., d50) of 2.4 microm at 16 1/min. The new sampler exhibited good agreement in three sets of co-located tests with established samplers, and parallel testing showed excellent agreement between paired HFPS samplers.

Air Movements↗

PM2.5 constituents and related air quality variables as predictors of survival in a cohort of U.S. military veterans.

Air quality data on trace metals, other constituents of PM2.5, and criteria air pollutants were used to examine relationships with long-term mortality in a cohort of male U.S. military veterans, along with data on vehicular traffic density (annual vehicle-miles traveled per unit of land area). The analysis used county-level environmental data for the period 1997-2002 and cohort mortality for 1997-2001. The proportional hazards model included individual data on age, race, smoking, body mass index, height, blood pressure, and selected interactions; contextual variables also controlled for climate, education, and income. In single-pollutant models, traffic density appears to be the most important predictor of survival, but potential contributions are also seen for NO2, NO3-, elemental carbon, nickel, and vanadium. The effects of the other main constituents of PM2.5, of crustal particles, and of peak levels of CO, O3, or SO2 appear to be less important. Traffic density is also consistently the most important environmental predictor in multiple-pollutant models, with combined relative risks up to about 1.2. However, from these findings it is not possible to discern which aspects of traffic (pollution, noise, stress) may be the most relevant to public health or whether an area-based predictor such as traffic density may have an inherent advantage over localized measures of ambient air quality. It is also possible that traffic density could be a marker for unmeasured pollutants or for geographic gradients per se. Pending resolution of these issues, including replication in other cohorts, it will be difficult to formulate additional cost-effective pollution control strategies that are likely to benefit public health.

Air Pollutants↗

Method comparisons for particulate nitrate, elemental carbon, and PM2.5 mass in seven U.S. cities.

Methods that measure PM2.5 mass, total particulate NO3-, and elemental carbon (EC) were evaluated in seven U.S. cities from 1997 to 1999. Sampling was performed in Bakersfield, CA; Boston, MA; Chicago, IL; Dallas, TX; Philadelphia, PA; Phoenix, AZ; and Riverside, CA. Evaluating and validating methods that measure the components of fine mass are important to the effort of establishing a speciation-monitoring network. The Harvard Impactor (HI), which measures fine particle mass, showed excellent agreement (r2 = 0.99) with the PM2.5 Federal Reference Method (FRM) for 81 24-hr samples in Riverside and Bakersfield. The HI also showed good precision (4.8%) for 243 24-hr collocated samples over eight studies. The Aethalometer was employed in six of the sampling locations to measure black carbon (BC). These values were compared to EC as measured from a quartz filter using thermal analysis. For the six cities combined, the two methods were highly correlated (r2 = 0.94; 187 24-hr samples); however, the BC values were approximately 24% less than the EC measurements consistently across all six cites. This compares well to results observed for EC/BC measurements observed in other semi-urban areas. Particulate NO3- was measured using the Harvard-EPA Annular Denuder System (HEADS). This was compared to the NO3- measured from the HI Teflon (DuPont) filter to assess NO3- artifacts. Significant NO3- losses (approximately 50% of total NO3-) were found in Riverside, Philadelphia, and Boston, while minimal artifacts were observed in the other sites. Two types of HEADS configurations were employed in five cities. One system used a Na2CO3-coated glass fiber filter, and the other type used a nylon filter to collect volatilized NO3- from the Teflon filter. The HEADS with the Na2CO3-coated filter consistently underestimated the total particulate NO3- by approximately 20% compared to the nylon HEADS.

Air Pollution↗

Comparison and evaluation of chemically speciated mobile source PM2.5 particulate matter profiles.

Mobile sources are significant contributors to ambient PM2.5, accounting for 50% or more of the total observed levels in some locations. One of the important methods for resolving the mobile source contribution is through chemical mass balance (CMB) receptor modeling. CMB requires chemically speciated source profiles with known uncertainty to ensure accurate source contribution estimates. Mobile source PM profiles are available from various sources and are generally in the form of weight fraction by chemical species. The weight fraction format is commonly used, since it is required for input into the CMB receptor model. This paper examines the similarities and differences in mobile source PM2.5 profiles that contain data for elements, ions, elemental carbon (EC) and organic carbon (OC), and in some cases speciated organics (e.g., polycyclic aromatic hydrocarbons [PAHs]), drawn from four different sources. Notable characteristics of the mass fraction data include variability (relative contributions of elements and ions) among supposedly similar sources and a wide range of average EC:OC ratios (0.60 +/- 0.53 to 1.42 +/- 2.99) for light-duty gasoline vehicles (LDGVs), indicating significant EC emissions from LDGVs in some cases. For diesel vehicles, average EC:OC ratios range from 1.09 +/- 2.66 to 3.54 +/- 3.07. That different populations of the same class of emitters can show considerable variability suggests caution should be exercised when selecting and using profiles in source apportionment studies.

Air Pollution↗

Development and evaluation of an impactor for a PM2.5 speciation sampler.

A conventional impactor for a particle speciation sampler was developed and validated through laboratory and field tests. The speciation sampler consists of the following components: a PM2.5 conventional impactor that removes particles larger than 2.5 microns, an all-glass, coated honeycomb diffusion denuder, and a 47-mm filter pack. The speciation sampler can operate at two different sampling rates: 10 and 16.7 L/min. An experimental characterization of the impactor's performance was conducted. The impactor's collection efficiency was examined as a function of critical design parameters such as Reynolds number, the distance from the nozzle exit to the impaction plate, and the impaction substrate coating method. The bounce of particles larger than the cut point was successfully minimized by using a greased surface as the impaction substrate. Additionally, a series of field intercomparison experiments were conducted at both 10 and 16.7 L/min airflow. PM2.5 mass and SO4(2-) concentrations were measured and compared with the Federal Reference Method (FRM) and found to be in good agreement. Results of the laboratory chamber tests also indicated that the impactor's performance was in good agreement with the FRM.

Air Pollution↗

Using continuous PM2.5 monitoring data to report an air quality index.

As stated in 40 CFR 58, Appendix G (2000), statistical linear regression models can be applied to relate PM2.5 continuous monitoring (CM) measurements with federal reference method (FRM) measurements, collocated or otherwise, for the purpose of reporting the air quality index (AQI). The CM measurements can then be transformed via the model to remove any bias relative to FRM measurements. The resulting FRM-like modeled measurements may be used to provide more timely reporting of a metropolitan statistical area's (MSA's) AQI. Of considerable importance is the quality of the model used to relate the CM and FRM measurements. The use of a poor model could result in misleading AQI reporting in the form of incorrectly claiming either good or bad air quality. This paper describes a measure of adequacy for deciding whether a statistical linear regression model that relates FRM and continuous PM2.5 measurements is sufficient for use in AQI reporting. The approach is the U.S. Environmental Protection Agency's (EPA's) data quality objectives (DQO) process, a seven-step strategic planning approach to determine the most appropriate data type, quality, quantity, and synthesis for a given activity. The chosen measure of model adequacy is r2, the square of the correlation coefficient between FRM measurements and their modeled counterparts. The paper concludes by developing regression models that meet this desired level of adequacy for the MSAs of Greensboro/Winston-Salem/High Point, NC; and Davenport/Moline/Rock Island, IA/IL. In both cases, a log transformation of the data appeared most appropriate. For the data from the Greensboro/Winston-Salem/High Point MSA, a simple linear regression model of the FRM and CM measurements had an r2 of 0.96, based on 227 paired observations. For the data from the Davenport/Moline/Rock Island MSA, due to seasonal differences between CM and FRM measurements, the simple linear regression model had to be expanded to include a temperature dependency, resulting in an r2 of 0.86, based on 214 paired observations.

Air Pollutants↗

Evaluation of the RAMS continuous monitor for determination of PM2.5 mass including semi-volatile material in Philadelphia, PA.

The real-time ambient mass sampler (RAMS) is a continuous monitor based on particle concentrator, denuder, drier, and tapered element oscillating microbalance (TEOM) monitor technology. It is designed to measure PM2.5 mass, including the semi-volatile species NH4NO3 and semi-volatile organic material, but not to measure PM2.5 water content. The performance of the RAMS in an urban environment with high humidity was evaluated during the July 1999 NARSTO-Northeast Oxidant and Particles Study (NEOPS) intensive study at the Baxter water treatment plant in Philadelphia, PA. The results obtained with the RAMS were compared to mass measurements made with a TEOM monitor and to constructed mass obtained with a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) sampler designed to determine the chemical composition of fine particles, including the semi-volatile species. An average of 28% of the fine particulate material present during the study was semi-volatile organic material lost from a filter during particle collection, and 1% was NH4NO3 that was also lost from the particles during sampling. The remaining mass was dominantly nonvolatile (NH4)2SO4 (31%) and organic material (37%), with minor amounts of soot, crustal material, and nonvolatile NH4NO3. Comparison of the RAMS and PC-BOSS results indicated that the RAMS correctly monitored for fine particulate mass, including the semivolatile material. In contrast, the heated filter of the TEOM monitor did not measure the semi-volatile material. The comparison of the RAMS and PC-BOSS data had a precision of +/-4.1 microg/m3 (+/-9.6%). The precision of the RAMS data was limited by the uncertainty in the blank correction for the reversible adsorption of water by the charcoal-impregnated cellulose sorbent filter of the RAMS monitor. The precision of the measurement of fine particulate components by the PC-BOSS was +/-6-8%.

Air Pollutants↗

Adjusting tapered element oscillating microbalance data for comparison with Federal Reference Method PM2.5 measurements in region 5.

Continuous monitoring of particulate matter (PM) with a diameter less than 2.5 microm (PM2.5) is quickly gaining acceptance as an alternative means of measuring fine PM in the United States. For this project, data were taken from all monitoring sites within Region 5 that used the tapered element oscillating microbalance (TEOM) for PM2.5 and had a collocated Federal Reference Method (FRM) monitor. Scatter plots of TEOM versus FRM show that for a significant fraction of the observations, an independent factor causes the TEOM to underestimate the FRM value. This underestimation appears to increase as temperature decreases. For this analysis, a linear relationship was fit to the TEOM versus FRM data, allowing a break or knot in the relationship, modeled as a change of slope, at a site-specific temperature. To test whether the models are adequate for adjusting future measurements, models were also developed using the first year of data only, and the remaining observations were used to test the durability of the relationships. For all but one monitor in Minnesota, the models developed for each site had consistently high R2s, were predictive of future measurements, and could be used to derive "FRM-like" results from the TEOM measurements. The temperature knots fitted by the model for individual sites ranged from 12.9 to 20.6 degrees C. Data from all six sites in the state of Michigan were also combined to determine if a single model could be developed for the entire state. While the single model for the state of Michigan worked reasonably well, some of the predicted concentrations at individual sites were systematically underestimating the observed concentrations on more polluted days. The same conclusion was drawn for a Region 5-wide model. This approach was also found to work very well for six individual TEOM monitors in New York State.

Air Pollutants↗

Semicontinuous PM2.5 sulfate and nitrate measurements at an urban and a rural location in New York: PMTACS-NY summer 2001 and 2002 campaigns.

Several collocated semicontinuous instruments measuring particulate matter with particle sizes < or =2.5 microm (PM2.5) sulfate (SO4(2-)) and nitrate (NO3-) were intercompared during two intensive field campaigns as part of the PM2.5 Technology Assessment and Characterization Study. The summer 2001 urban campaign in Queens, NY, and the summer 2002 rural campaign in upstate New York (Whiteface Mountain) hosted an operation of an Aerosol Mass Spectrometer, Ambient Particulate Sulfate and Nitrate Monitors, a Continuous Ambient Sulfate Monitor, and a Particle-Into-Liquid Sampler with Ion Chromatographs (PILS-IC). These instruments provided near real-time particulate SO4(2-) and NO3- mass concentration data, allowing the study of particulate SO4(2-)/NO3- diurnal patterns and detection of short-term events. Typical particulate SO4(2-) concentrations were comparable at both sites (ranging from 0 to 20 microg/m3), while ambient urban particulate NO3- concentrations ranged from 0 to 11 microg/m3 and rural NO3- concentration was typically less than 1 microg/m3. Results of the intercomparisons of the semicontinuous measurements are presented, as are results of the comparisons between the semicontinuous and time-integrated filter-based measurements. The comparisons at both sites, in most cases, indicated similar performance characteristics. In addition, charge balance calculations, based on major soluble ionic components of atmospheric aerosol from the PILS-IC and the filter measurements, indicated slightly acidic aerosol at both locations.

Air Pollutants↗

Traffic-related occupational exposures to PM2.5, CO, and VOCs in Trujillo, Peru.

A traffic-related exposure study was conducted among 58 workers (drivers, vendors, traffic police, and gas station attendants) and 10 office workers as controls in Trujillo, Peru, in July 2002. PM2.5 was collected, carbon monoxide (CO) was measured, volatile organic compounds (VOCs) were sampled and analyzed. Newspaper vendors had the highest full-shift CO exposures (mean +/- SD: 11.4 +/- 8.9 ppm), while office workers had the lowest (2.0 +/- 1.7 ppm). Bus drivers had the highest full-shift PM2.5 exposures (161 +/- 8.9 microg/m3), while gas station attendants (64 +/- 26.5 microg/m3) and office workers (65 +/- 8.5 microg/m3) were the lowest. Full-shift benzene/toluene/ethylbenzene/xylene exposures (BTEX) among gas station attendants (111/254/43/214 microg/m3) were much higher than those among van and taxi drivers. Several of the traffic-related occupational exposures studied were elevated and are of occupational health concern.

Air Pollutants, Occupational↗

Comparison of oxidative properties, light absorbance, total and elemental mass concentration of ambient PM2.5 collected at 20 European sites.

OBJECTIVE: It has been proposed that the redox activity of particles may represent a major determinant of their toxicity. We measured the in vitro ability of ambient fine particles [particulate matter with aerodynamic diameters<or=2.5 microm (PM2.5)] to form hydroxyl radicals (.OH) in an oxidant environment, as well as to deplete physiologic antioxidants (ascorbic acid, glutathione) in the naturally reducing environment of the respiratory tract lining fluid (RTLF). The objective was to examine how these toxicologically relevant measures were related to other PM characteristics, such as total and elemental mass concentration and light absorbance. DESIGN: Gravimetric PM2.5 samples (n=716) collected over 1 year from 20 centers participating in the European Community Respiratory Health Survey were available. Light absorbance of these filters was measured with reflectometry. PM suspensions were recovered from filters by vortexing and sonication before dilution to a standard concentration. The oxidative activity of these particle suspensions was then assessed by measuring their ability to generate .OH in the presence of hydrogen peroxide, using electron spin resonance and 5,5-dimethyl-1-pyrroline-N-oxide as spin trap, or by establishing their capacity to deplete antioxidants from a synthetic model of the RTLF. RESULTS AND CONCLUSION: PM oxidative activity varied significantly among European sampling sites. Correlations between oxidative activity and all other characteristics of PM were low, both within centers (temporal correlation) and across communities (annual mean). Thus, no single surrogate measure of PM redox activity could be identified. Because these novel measures are suggested to reflect crucial biologic mechanisms of PM, their use may be pertinent in epidemiologic studies. Therefore, it is important to define the appropriate methods to determine oxidative activity of PM.

Air Pollutants↗

Assessment of public health risks associated with atmospheric exposure to PM2.5 in Washington, DC, USA.

In this research, we investigated the public health risks associated with atmospheric exposure to PM2.5 for different subpopulations (black, white, Hispanic, youth, adults, and elderly) in the Washington, DC area. Washington, DC has long been considered a non-healthy place to live according to the American Lung Association due to its poor air quality. This recognition clearly includes the negative PM-related human health effects within the region. Specifically, DC fine particulate matter (PM2.5) [or particulate matter with an aerodynamic diameter less than 2.5 microm] poses notable health risks to subpopulations having an annual mean value of 16.70 microg/m(3) during the years 1999-2004, exceeding the EPA National Ambient Air Quality Standard (NAAQS) of 15 microg/m(3). Incessant exposure to significant levels of PM has previously been linked to deleterious health effects, such as heart and lung diseases. The environmental quality and public health statistics of Washington, DC indicate the need for higher-resolution measurements of emissions, both spatially and temporally, and increased analysis of PM-related health effects. Our findings show that there are significant risks of ward-specific pediatric asthma emergency room visits (ERV). Results also illustrate lifetime excess lung cancer risks, exceeding the 1 x 10(-6) threshold for the measured levels of particulate matter and heavy metals (chromium and arsenic) on behalf of numerous subpopulations in the DC selected wards.

Air Pollutants↗