PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polycarbonates”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Metal salen derivatives as catalysts for the alternating copolymerization of oxetanes and carbon dioxide to afford polycarbonates.

Metal salen derivatives of chromium and aluminum, along with n-Bu4NX (X = Cl or N3) salts, have been shown to be effective catalysts for the selective coupling of CO2 and oxetane (trimethylene oxide) to provide the corresponding polycarbonate with only trace quantities of ether linkages. The formation of copolymer is suggested, based on circumstantial evidence, not to proceed via the intermediacy of trimethylene carbonate, which was observed as a minor product of the coupling reaction. For a reaction catalyzed by (salen)CrCl in the presence of n-Bu4NN3 as the cocatalyst, both matrix-assisted laser desorption ionization time-of-flight mass spectrometry and infrared spectroscopy revealed an azide end group in the copolymer.

Aluminum↗

Synthesis and characterization of a polycarbon organometallic cluster, [PPN]2[Fe6(CO)18C4].

The polycarbon metal cluster [Fe6(CO)18C4]2- is formed by the reaction of CF3SO3SO2CF3 with [Fe3(CO)9(CCO)]2-. Apparently, the SO2CF3 moiety abstracts an oxygen from the ketenylidene (CCO) ligand and C-C coupling occurs to form the C4 ligand. A single-crystal X-ray structure determination reveals that the pattern of C-C bond lengths of the C4 ligand in [Fe6(CO)18C4]2- mimic those in free butadiene.

Journal Article↗

Mechanically linked polycarbonate.

The synthesis, by solid-state copolymerization, and characterization of the first polycatenanes based on a commercial polymer are reported. Various amounts of a benzylic amide [2]catenane, the corresponding macrocycle, and a rigid bisphenol fluorene derivative have been quantitatively and homogeneously incorporated into bisphenol A polycarbonate. The resulting copolymers were characterized by size exclusion chromatography coupled with viscosimetry, (1)H NMR, differential scanning calorimetry, and dynamic mechanical analysis. The unexpectedly small influence of [2]catenane incorporation on the glass transition temperature of the copolymers points to remarkable internal mobility of the catenane comonomer rings. A new relaxation linked to the flexible catenane units is also observed. The studies represent a detailed structural characterization of a polymer containing small amounts of mechanical linkages in its backbone and demonstrate that significant effects can be induced by doping conventional polymers with small percentages (2-6% of repeat units) of flexible catenanes.

Journal Article↗

Effects of housing on consummatory successive negative contrast in rats: wire-bottom cages versus polycarbonate tubs.

In consummatory successive negative contrast, rats that have had experience drinking 32% sucrose solution drink significantly less 4% sucrose solution than rats that have drunk only 4% solution. This contrast effect occurs reliably when rats are housed in wire-bottom cages, but it occurs significantly less frequently when rats are housed in polycarbonate tubs. Although it is unclear what causes these differences among housing conditions, the present study underscores the impact that housing conditions outside the domain of the training environment can have on behavioral outcomes.

Animal Husbandry↗

Simulation of the plastic behavior of amorphous glassy bis-phenol-A-polycarbonate.

A protocol for studying the plastic deformation of amorphous glassy polymers is presented. The protocol is based on a viable computational procedure which combines constant-stress molecular dynamics simulations and fixed-cell energy minimizations, followed by kinetic, configurational, and energy analyses. It is shown that the computational results can be accounted for within a "potential energy landscape" theoretical framework, in which the plastic transition is interpreted as a crossing between and a collapse onto each other of "ideal (thermodynamic) structures." The procedure is applied to bis-phenol-A-polycarbonate (BPA-PC), but is equally valid for a wide variety of polymeric species. Allowing for the limited size of the simulation cell, the high strain rate, and the fact that the simulation are conducted at low temperature, the values of the density, Young's modulus, yield strain, yield stress, activation energy, and activation volume are in fair agreement with the experimental data on BPA-PC. The analysis of the results shows that the plastic relaxation for this polymer has both a collective and cooperative character (as in classical percolation theories), involves a significant fraction of the simulation cell, and can be viewed as a "nanoscopic shear band."

Journal Article↗

Spatial scale-dependent tracer diffusion in bulk polycarbonate studied by holographic relaxation.

The diffusion of a photochromic dye tracer in polycarbonate was studied by a holographic relaxation technique (forced Rayleigh scattering) at temperatures close to the glass transition temperature. By varying the holographic grating period the results could be interpreted via the spatial scale dependence of apparent diffusion coefficients within a two-state diffusion model. This indicates inhomogeneities on the scale of a few micrometers in the polymer glass.

Journal Article↗

Near-infrared optical-absorption behavior in high-beta nonlinear optical chromophore-polymer guest-host materials. II. Dye spacer length effects in an amorphous polycarbonate copolymer host.

In the second of a three-part series, spectral absorption behavior of nonlinear optical (NLO) dyes incorporated into amorphous polycarbonate, comprised of a homologous series of dialkyl spacer groups extending from the midsection of the dye molecule, is characterized by UV-Vis and photothermal deflection spectroscopy. The dyes are structural analogs of the NLO dye FTC [2-(3-cyano-4-{2-[5-(2-{4-[ethyl-(2-methoxyethyl)amino]phenyl}vinyl)-3,4-diethylthiophen-2-yl]vinyl}-5,5-dimethyl-5H-furan-2-ylidene)malononitrile]. Previous Monte Carlo calculations [B. H. Robinson and L. R. Dalton, J. Phys. Chem. A 104, 4785 (2000)] predict a strong dependence of the macroscopic nonlinear optical susceptibility on the chromophore waist: length aspect ratio in electric-field-poled films arising from interactions between chromophores. It is expected that these interactions will play a role in the absorption characteristics of unpoled films, as well. The spacer groups range in length from diethyl to dihexyl, and each dye is studied over a wide range of concentrations. Among the four dyes studied, a universal dependence of near-IR loss on inhomogeneous broadening of the dye main absorption peak is found. The inhomogeneous width and its concentration dependence are seen to vary with spacer length in a manner characteristic of the near-IR loss-concentration slope at transmission wavelengths of 1.06 and 1.3 mum, but not at 1.55 mum. The lower wavelength loss behavior is assigned to purely Gaussian broadening, and is described by classical mixing thermodynamic quantities based on the Marcus theory of inhomogeneous broadening [R. A. Marcus, J. Chem. Phys. 43, 1261 (1965)], modeled as a convolution of dye-dye dipole broadening and dye-polymer van der Waals broadening. The Gaussian dipole interactions follow a Loring dipole-broadening description [R. F. Loring, J. Phys. Chem. 94, 513 (1990)] dominated by the excited-state dipole moment, and have a correlated homogeneous broadening contribution. The long-wavelength loss behavior has a non-Gaussian dye-dye dipole contribution which follows Kador's broadening analysis [L. Kador, J. Chem. Phys. 95, 5574 (1991)], with a net broadening described by a convolution of this term with a Gaussian van der Waals interaction given by Obata et al. [M. Obata, S. Machida, and K. Horie, J. Polym. Sci. B 37, 2173 (1999)], with each term governed by the dye spacer length. A minimum in broadening and loss-concentration slope at a spacer length of four carbons per alkyl at all wavelengths has important consequences for practical waveguide devices, and is of higher aspect ratio than the spherical limit shown by Robinson and Dalton to minimize dipole interactions under a poling field.

Journal Article↗

Sub-Tg dynamics in polycarbonate by neutron scattering and its relation with secondary gamma relaxation.

We have investigated the dynamics of phenylene rings in glassy bisphenol-A (BPA) polycarbonate (PC) by means of quasielastic neutron scattering. Taking advantage of selective deuteration of the samples, we have studied the incoherent scattering of hydrogens in phenylene rings on the one hand, and on the other hand the coherent quasielastic scattering of all the atoms in the sample. Two different types of neutron spectrometers, time of flight and backscattering, were used in order to cover a wide dynamic range, which extends from microscopic (approximately 10(-13) s) to mesoscopic (approximately 10(-9) s) times. Moreover, neutron-diffraction experiments with polarization analysis were carried out in order to characterize the structural features, and the relative coherent and incoherent contributions of the samples investigated. In contrast with previous studies of phenylene ring dynamics in BPA polysulfone performed by us also by neutron scattering, phenylene rings in BPA PC exhibit an "extra" motion in addition to those found for BPA polysulfone's phenylene rings. This extra motion of the rings in PC perfectly correlates with the main carbonate group motion followed by dielectric spectroscopy and allows us to (i) consistently interpret the PC's gamma relaxation in terms of two different motions; and (ii) experimentally confirm the relation between the motion of phenylene rings and carbonate groups within BPA PC formerly predicted by computational methods.

Journal Article↗

A new polycarbonate fast neutron personnel dosimeter.

Registration of fast-neutron-induced recoil and (n,alpha) tracks directly in sensitive polymers especially polycarbonate foils when etched by the electrochemical etching (ECE) method provides a simple, sensitive, and inexpensive means of fast neutron dosimetry. The wide dose range and a dose equivalent response, negligible fading rate, and insensitivity to X, beta, and gamma radiations make such a method feasible for many neutron dosimetry applications, especially personnel dosimetry. Due to very large size of the tracks, even the unaided eye can be used as a reading device.

Carbonates↗

Influence of flavour absorption by food-packaging materials (low-density polyethylene, polycarbonate and polyethylene terephthalate) on taste perception of a model solution and orange juice.

The influence of flavour absorption by low-density polyethylene (LDPE), polycarbonate (PC) and polyethylene terephthalate (PET) on taste perception of a model solution containing seven flavour compounds and orange juice in glass bottles was studied with and without pieces of the respective plastic films after dark storage at 20 degrees C. Owing to absorption, the amount of flavour compounds in the model solution exposed to LDPE decreased substantially. From the model flavour solution valencene was almost completely absorbed by LDPE, followed to a lesser extent by decanal, hexyl acetate, octanal and nonanone. Less flavour compounds were absorbed from the model solution by PC and PET. In contrast to LDPE, valencene was absorbed in the lowest amounts and decanal in the highest. Limonene was readily absorbed from orange juice by LDPE, while myrcene, valencene, pinene and decanal were absorbed in smaller quantities. Only three flavour compounds were absorbed from orange juice by PC and PET in very small amounts: limonene, myrcene and decanal. Although the flavour content between controls and polymer-treated samples differed substantially, the loss of flavour compounds due to absorption by LDPE, PC and PET did not influence taste perception of a model solution and orange juice significantly up to 29 days of dark storage at 20 degrees C as determined by triangular taste panel tests.

Absorption↗

Dietary exposure assessment of infants to bisphenol A from the use of polycarbonate baby milk bottles.

The residual bisphenol A (BPA) levels in 28 different brands of polycarbonate (PC) baby milk bottles available in the Singapore market were measured. With a detection limit of 3 mg/kg, BPA residues were detected in 19 out of the 28 PC baby milk bottles at levels between 4.01 and 141 mg/kg, with a mean of 28.1 +/- 31.4 mg/kg and a median of 17.2 mg/kg. The potential migration of BPA from each of the 28 PC milk bottles was also measured using food-simulating solvents and time conditions recommended by the US Food and Drug Administration (US FDA), but using temperatures more severe than actual use. The highest upper-bound mean BPA migration levels of 0.64 +/- 0.48 microg/in2 in 10% ethanol at 70 degrees C and 0.43 +/- 1.25 microg/in2 in corn oil at 100 degrees C were observed after incubating cut portions of the milk bottles for 240 h. With this migration data and using US FDA's procedure for estimation of dietary exposure, the worst-case dietary exposure assessment for the intake of BPA by infants between birth and three months of age was below the oral Reference Dose of 0.05 mg/kg bw/day established by the US Environmental Protection Agency. This study showed that the dietary exposure to BPA from actual uses of PC milk bottles is unlikely to pose a health risk in infants.

Benzhydryl Compounds↗

Investigations into the potential degradation of polycarbonate baby bottles during sterilization with consequent release of bisphenol A.

Twenty-four brands of plastic baby feeding bottles were purchased and all were found to be made of polycarbonate. Taking a batch of one representative sample, the polymer was tested for stability and possible release of bisphenol A following domestic practice of sterilization. Sterilization was by alkaline hypochlorite, steam, or washing in an automatic dishwasher at 65 degrees C with detergent. A total of 20 cycles of sterilization and subsequent food use were performed for each of the three procedures. Bisphenol A migration was in all cases not detectable in infant feed using a very sensitive method of liquid chromatography with fluorescence detection with a 0.03 mg/kg detection limit.

Benzhydryl Compounds↗

Development of emission factors for polycarbonate processing.

Emission factors for selected volatile organic compounds (VOCs) and particulate emissions were developed while processing eight commercial grades of polycarbonate (PC) and one grade of a PC/acrylonitrile-butadiene-styrene (ABS) blend. A small commercial-type extruder was used, and the extrusion temperature was held constant at 304 degrees C. An emission factor was calculated for each substance measured and is reported as pounds released to the atmosphere/million pounds of polymer resin processed [ppm (wt/wt)]. Scaled to production volumes, these emission factors can be used by processors to estimate emission quantities from similar PC processing operations.

Air Pollutants↗

Development of a high efficiency personal/environmental radon dosimeter using polycarbonate detectors.

Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the assessment of radon exposure. These methods are often applied in radon dosimetry for long periods of time. In this research work, we have developed a highly efficient method of personal/environmental radon dosimetry that is based upon the detection of alpha particles from radon daughters, (218)Po and (214)Po, using a polycarbonate detector (PC). The radon daughters are collected on the filter surface by passing a fixed flow of air through it and the PC detector, placed at a specified distance from the filter, is simultaneously exposed to alpha particles. After exposure, the latent tracks on the detector are made to appear by means of an electrochemical etching process; these are proportional to the radon dose. The air flow rate and the detector-filter distance are the major factors that can affect the performance of the dosimeter. The results obtained in our experimental investigations have shown that a distance of 1.5 cm between the detector and the filter, an absorber layer of Al with a thickness of 12 microm and an air flow rate of 4 l min(-1) offer the best design parameters for a high efficiency radon dosimeter. Then, the designed dosimeter was calibrated against different values of radon exposures and the obtained sensitivity was found to be 2.1 (tracks cm(-2)) (kBq h m(-3))(-1). The most important advantages of this method are that it is reliable, fast and convenient when used for radon dose assessment. In this paper, the optimized parameters of the dosimeter structure and its calibration procedure are presented and discussed.

Dose-Response Relationship, Radiation↗

Measurement of low neutron fluences with polycarbonate foils electrochemically etched with methyl alcohol-KOH solution.

Electrochemical etching of polycarbonate foils was performed using a KOH solution with a high concentration of methyl alcohol under different conditions of field strength, frequency, temperature and etching time. these studies showed that the highest neutron sensitivity relative to the inherent background in the foil was obtained under the following etching conditions: 52 kV/cm, 1 kHz, 30 degrees C, 30 min in a solution of 45 gm KOH + 80 cc CH3OH + 20 cc H2O. Under these conditions, 100 mrem of neutrons from a Ra-Be source gave 70 pits per cm2 while background was 7 +/- 3 pits per cm2 (10 +/- 5 mrem). The pit diameters were about 90 micrometers. This sensitivity (giving lowest measurable dose of 15 mrem) is quite sufficient for personnel neutron dosimetry applications and the size of the pits is large enough for easy counting using a microscope at a magnification of 40 X.

Electrochemistry↗

Measurement of natural neutron background using electrochemically etched polycarbonate foils and boron-10 radiators.

Electrochemical etching of polycarbonate foils was performed using a KOH solution with various concentrations of ethyl alcohol under different conditions of field strength, frequency, temperature and etching time to register alpha-particles from a 10B radiator positioned in the center of a 25-cm diameter polyethylene sphere. These studies showed that the highest neutron sensitivity relative to the inherent background in the foil was obtained under the following etching conditions: 32 kV/cm, 1 kHz, 30 degrees C, 2 hr in a solution of 35 gm KOH + 25 cm3 C2H5OH + 75 cm3 H20. Under these conditions, 1 mrem of neutrons from a Ra-Be source gave 155 pits per cm2 while background was 1-3 pits per cm2. The pit diameters were about 75 microns. The dose can be measured to an uncertainty of +/- 100% at 0.1 mrem and +/- 10% at 1 mrem. This method was used to measure the natural neutron background and gave 17 pits per cm2 (0.1 mrem +/- 0.1 mrem) per month in a building.

Background Radiation↗

A polycarbonate ophthalmic-prescription lens series.

Improvements in polycarbonate material, production techniques, and scratch-resistant coatings, combined with a process-oriented design, have resulted in a precision lens series. Surface quality is comparable to that of untreated glass ophthalmic lenses. The repeatability of the process results in closely controlled axial power and off-axis performance. For most lens prescriptions, the ANSI Z80.1 optical-center specifications for prescription accuracy are maintained through a total field of view of 40 deg for an 8-mm range of center-of-rotation distances. Off-axis astigmatism is controlled for near-point seeing. The lenses are both lighter and thinner than those of crown glass. A scratch-resistant coating reduces the reflections normally associated with high-index (1.586) materials. Impact resistance exceeds that required by ANSI Z80.7 and is many times that required by ANSI Z80.1.

Carbonates↗

Dual-resolution coarse-grained simulation of the bisphenol-A-polycarbonate/nickel interface.

We present a dual-resolution coarse-graining scheme for efficient molecular dynamics simulations of bisphenol-A-polycarbonate (BP-A-PC) liquids in contact with a (111) nickel surface. The essential feature of this model is the strong adsorption of phenoxy chain ends, and the absence of adsorption by other parts of the chains. Details of how phenoxy chain ends interact with the nickel surface were extracted from Car-Parrinello molecular dynamics calculations of adsorption of phenol on nickel. These calculations show that phenol adsorption on nickel is short ranged (<3 A) and strongly dependent on the C1-C4 orientation of the ring. The structure of BP-A-PC prevents internal phenylene groups from interacting with the surface, due to steric hindrances from the noninteracting isopropylidenes. These dependencies are incorporated in the coarse-grained model of the BP-A-PC chain by resolving chain-terminating carbonate groups with atomistic detail, while the rest of the chain is represented by coarsened "beads." This allows specification of the C1-C4 orientation of the terminal phenoxy groups, while overall allowing for system equilibration with reasonable computer time. We simulate liquids of up to 240 chains of ten chemical repeat units, confined in a slit pore formed by two frozen (111) planes of atoms with the lattice spacing of nickel. We find that the strong adsorption of chain ends has a large effect on the liquid structure through a distance of more than two bulk radii of gyration from the surface. These effects are explained by a competition among single- and double-end adsorption, and dense packing. The structure of the interface less than 10 A from the wall is greatly sensitive to the orientational dependence of the phenoxy adsorption.

Journal Article↗