PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tooth Preparation, Prosthodontic”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Dentin exposure in tooth preparations for porcelain veneers: a pilot study.

STATEMENT OF PROBLEM: The various clinical techniques available for even reduction of a tooth surface to receive a porcelain veneer restoration do not produce a consistently even conservative reduction. In addition, it is not known which technique is most conservative of enamel. PURPOSE: The purpose of this pilot study was to assess the effectiveness of 3 clinical techniques, namely, dimple, depth groove, and freehand, in producing an intraenamel preparation. The relation between overpreparation beyond the commonly accepted depth of preparation of 0.5 mm and dentin exposure was also examined. MATERIAL AND METHODS: A single operator prepared 3 groups of 5 extracted maxillary central incisors to a depth of 0.5 mm using dimple, depth-groove, and freehand methods of tooth preparation. The prepared teeth were scanned using an x-ray microtomography scanner. The reconstructed images were studied using software that provided a volume-rendering routine so that, by choosing suitable x-ray linear attenuation coefficient thresholds, enamel (2.78 cm(-1) at 40 keV) and dentin (1.63 cm(-1) at 40 keV) surfaces could be viewed. The percentage area of enamel conserved was analyzed from these images. Coordinate metrology was used to produce color-coded images depicting the depth of preparation. The Kruskal-Wallis test was used to determine the statistical significance (alpha=.05) in the difference between the mean percentage area of enamel conserved in the 3 technique groups. The coordinate metrology and x-ray microtomography images were visually compared to study the correlation between overpreparation and dentin exposure. RESULTS: The Kruskal-Wallis test did not demonstrate significant difference (P=.07) between the 3 techniques in conserving enamel. However, the dimple technique showed a greater trend to retaining a larger mean percentage area of enamel (77.5% +/- 14.2) compared to depth-groove (50.1% +/- 17.5) and freehand (76.8% +/- 24.4) techniques. Preparation depth in the range of 0.4 to 0.6 mm was largely seen to be intraenamel, except in the cervical region. CONCLUSION: Within the limitations of this pilot study, the 3 different techniques tested did not differ significantly in conserving enamel.

Dental Porcelain↗

The use of a resin-bonded prosthesis while maintaining the diastemata: a clinical report.

A dental arch with diastemata and missing lateral incisors represents a challenge because of discrepancies in tooth size. If an implant-supported prosthesis is not possible or not selected as a treatment option, a modified resin-bonded fixed partial denture may be a treatment option to eliminate the esthetic problems of conventional fixed partial dentures. This clinical report describes the procedures to replace congenitally missing lateral incisors with a resin-bonded prosthesis, while maintaining diastemata.

Adult↗

A three-dimensional evaluation of a laser scanner and a touch-probe scanner.

STATEMENT OF PROBLEM: The fit of a dental restoration depends on quality throughout the entire manufacturing process. There is difficulty in assessing the surface topography of an object with a complex form, such as teeth, since there is no exact reference form. PURPOSE: The purpose of this study was to determine the repeatability and relative accuracy of 2 dental surface digitization devices. A computer-aided design (CAD) technique was used for evaluation to calculate and present the deviations 3-dimensionally. MATERIAL AND METHODS: Ten dies of teeth prepared for complete crowns were fabricated in presintered yttria-stabilized tetragonal zirconia (Y-TZP). The surfaces were digitized 3 times each with an optical or mechanical digitizer. The number of points in the point clouds from each reading were calculated and used as the CAD reference model (CRM). Alignments were performed by registration software that works by minimizing a distance criterion. In color-difference maps, the distribution of the discrepancies between the surfaces in the CRM and the 3-dimensional surface models was identified and located. RESULTS: The repeatability of both scanners was within 10 microm, based on SD and absolute mean values. The qualitative evaluation resulted in an even distribution of the deviations in the optical digitizer, whereas the dominating part of the surfaces in the mechanical digitizer showed no deviations. The relative accuracy of the 2 surface digitization devices was within +/- 6 microm, based on median values. CONCLUSION: The repeatability of the optical digitizer was comparable with the mechanical digitization device, and the relative accuracy was similar.

Computer-Aided Design↗

Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowns.

STATEMENT OF PROBLEM: Gold electroformed metal-ceramic restorations have been promoted as alternatives to conventional metal-ceramic restorations. However, little is known about the relationship between tooth preparation design and marginal adaptation for this type of crown. PURPOSE: This study evaluated the influence of 3 different finish line designs on the marginal adaptation of electroformed metal copings and metal-ceramic crowns. MATERIAL AND METHODS: Three steel dies were prepared for maxillary central incisor crowns with 3 finish line designs: shoulder, rounded shoulder, and deep chamfer preparations. Eight standardized electroformed metal-ceramic crowns were fabricated for each group. Marginal discrepancies were measured at 60 points for each specimen along the circumferential margin at 4 sites (labial, mesial, lingual, and distal surfaces, with 15 points for each site) before and after firing procedures using a laser microscope. Data among the 3 different groups were statistically analyzed using the Kruskal-Wallis test and the Mann-Whitney U test with the Bonferroni correction. Marginal discrepancies between prefiring and postfiring procedures were evaluated using the Wilcoxon signed-ranks test (alpha = .05). RESULTS: Significant differences in the marginal discrepancies of electroformed metal copings without porcelain and metal-ceramic crowns were found among all groups. The lowest range of median marginal discrepancy values (P < .05) at 4 sites, both before and after firing, occurred with the deep chamfer preparation (17.64-21.78 microm and 23.96-25.72 microm, respectively). The highest range values were observed in the shoulder preparation (38.13-49.89 microm and 73.87-89.44 microm, respectively). In all situations, the marginal discrepancies of the postfiring procedures were significantly greater (P = .02 or less) than those of the prefiring procedures. CONCLUSION: Within the limitations of this study, the marginal adaptation of electroformed metal copings or metal-ceramic crowns is affected by finish line design and sequentially diminished by porcelain firing procedures.

Aluminum Silicates↗

Effect of dentin bonding and ferrule preparation on the fracture strength of crowned teeth restored with dowels and amalgam cores.

STATEMENT OF PROBLEM: It is necessary to obtain an adequate bond at the core/dentin junction where the majority of failures occur. The effect of recently developed dentin bonding agents on the fracture resistance of endodontically treated teeth at the amalgam core/dentin junction is unclear. PURPOSE: The purpose of this study was to evaluate the effects of 2 dentin bonding agents and a ferrule preparation on the fracture resistance of crowned mandibular premolars incorporating prefabricated dowel and silver amalgam cores. MATERIAL AND METHODS: Sixty extracted mandibular second premolars were divided into 6 groups of 10 each. The coronal portion of each tooth was removed at the cemento-enamel junction (CEJ) in the first 3 groups. In the other groups, teeth were sectioned 1 mm above the CEJ to create a ferrule. After root canal preparations, prefabricated dowels (ParaPost) were placed. The first group served as a control and was tested without application of bonding agents and without incorporation of a ferrule design. In the second and third groups, respectively, an autopolymerizing adhesive (Superbond D-Liner) and a dual-polymerizing adhesive (Panavia F) were applied to tooth surfaces before restorative procedures. For the fourth (ferrule) group, no bonding agent was applied, but a 1-mm ferrule preparation was used. In the fifth (ferrule+D-Liner) and sixth (ferrule+Panavia F) groups, respectively, autopolymerizing and dual-polymerizing bonding agents were used in conjunction with the ferrule preparation. After amalgam core fabrication, Ni-Cr full cast crowns for each group were prepared and cemented. All specimens were stored in water for 1 week and thermal cycled 1000 times between 5 degrees and 55 degrees C. A compressive shear load was applied at an angle of 135 degrees to the crown, and the maximum load at fracture (N) was recorded. The data were analyzed with 1-way ANOVA and Tukey Honestly Significant Difference tests (alpha=.05). RESULTS: Significantly higher fracture strength values were demonstrated for the ferrule+Panavia F (652.5 N), ferrule+D-liner (649.1 N) and ferrule (592.4 N) groups, respectively, than for the other groups. The next highest fracture strength values were found for the D-Liner (485.0 N) and Panavia F (486.3 N) groups. The control group (376.6 N) demonstrated the lowest fracture strength in all test groups (P<.001). CONCLUSION: A ferrule preparation or a bonding agent designed for silver amalgam core-dentin bonding can each increase the fracture strength for teeth receiving cast crowns after endodontic therapy and dowel and amalgam core restorations.

Analysis of Variance↗

The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading.

STATEMENT OF PROBLEM: Clinicians have used resistance form as a basis for determining guidelines for preparation design to ensure clinical success of cemented cast restorations. Disagreement on whether clinical success follows the on-off or linear nature of resistance form continues. PURPOSE: The purpose of this study was to evaluate the number of cycles required to dislodge a cemented complete crown casting under a cyclic lateral load as a function of taper and to compare this relationship for the resistive and nonresistive ranges of taper. MATERIAL AND METHODS: Three dies were milled from stainless steel at each of the following tapers: 4, 8, 12, 16, 20, 24, 28, and 32 degrees. A gold-palladium metal-ceramic alloy crown was fabricated for each die, cemented, and subjected to lateral cyclic loading until failure or 1,000,000 cycles. The limiting taper for the dies with their given height and base was 26.6 degrees. Dies with taper less than 26.6 degrees had resistance form, whereas dies with taper larger than 26.6 degrees did not. A linear regression (alpha=.05) was used to evaluate the relation of cycles at dislodgement to taper. RESULTS: The average number of cycles to crown dislodgement or completion for each taper (SD), in units of 10,000, was as follows: 4 degrees, 100 (0); 8 degrees, 100 (0); 12 degrees, 93.54 (16.56); 16 degrees, 61.33 (38.47); 20 degrees, 25.73 (34.67); 24 degrees, 4.33 (7.36); 28 degrees, 0.06 (0.08); and 32 degrees, 0.05 (0.09). The crowns in the resistive area less than 26.6 degrees that demonstrated failure showed a linear regression with a correlation coefficient of -0.995 between the average number of cycles to dislodge the crown and the taper. The slope was significantly different from zero (P=.0048), with a value of -7.58 and a standard error of 0.53. CONCLUSION: The number of cycles required to cause crown dislodgement was linear after 12 degrees in the resistive area and nearly zero for preparations in the nonresistive area. The limiting taper concept closely predicted the transition point where the slope of the graph of cycles to dislodgement as a function of taper abruptly changed.

Cementation↗

The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study.

STATEMENT OF PROBLEM: Although zirconium-oxide-based restorations for fixed partial denture prostheses (FPDPs) are available for use, clinical studies evaluating their longevity and related complications have not been published. PURPOSE: The aim of this pilot clinical study was to assess the efficacy of zirconia-based posterior 3-unit FPDPs. MATERIAL AND METHODS: Twenty 3-unit posterior FPDPs (Lava) were placed in 16 subjects who were missing a second premolar or a first molar, met specific inclusion and exclusion criteria, and provided informed consent. All teeth were prepared in a standardized manner: occlusal reduction of 1.5 to 2 mm; axial reduction of 1 to 1.5 mm; a 1.0-mm, 360-degree rounded shoulder placed 0.5 mm subgingivally on the facial aspect and supragingivally on the lingual aspect on sound tooth structure; and rounded internal line angles. Impressions were made with vinyl polysiloxane (Express) impression material. Frameworks were fabricated using a computer-aided design/computer-assisted manufacturing technique with a retainer thickness of 0.6 mm, and a minimal connector surface area of 9 mm(2). Restorations were luted with resin-modified glass-ionomer cement (Rely X luting). Recall appointments were made after 2 weeks and 6, 12, 18, 24, and 36 months. Clinical fracture resistance, marginal discoloration, marginal adaptation, radiographic proximal recurrent decay, and periapical pathoses were assessed over time using modified Ryge criteria. The probability distributions of these variables were calculated for the baseline data as well as for recall data. RESULTS: Mean follow-up was 31.2 months. Fifteen restorations were rated Alpha in all measured parameters. Minor chipping of veneering porcelain was detected in 5 restorations rated Bravo for clinical fracture resistance and Alpha for all other assessed parameters. One restoration was rated Bravo in terms of marginal integrity at 36 months. CONCLUSIONS: Zirconia-based posterior 3-unit FPDPs performed well after short-term service.

Adult↗

Long-term clinical results of galvano-ceramic and glass-ceramic individual crowns.

STATEMENT OF PROBLEM: Alternatives to metal-ceramic restorations should possess clinical durability before being recommended to the dentist. Longitudinal clinical studies are required for evaluation so innovative types of restorations can meet the expectations of dentists and patients. PURPOSE: This study compared the performance of galvano-ceramic restorations (Auvo Galvano Crown [ACG]) and glass-ceramic individual crowns (Dicor) based on longitudinal clinical trials. MATERIAL AND METHODS: A total of 769 galvano-ceramic single crowns (AGC) in 322 patients and 173 glass-ceramic individual crowns (Dicor) in 88 patients were reviewed for 8 years and a maximum of 11 years, respectively, after cementation. Risk of fracture was determined with use of a survival analysis (Kaplan and Meier). RESULTS: Partial ceramic cracking was observed at the time of the last recording of data in 11 galvano-ceramic crowns, 8 of the units remained in place. Two crowns became dislodged and 1 tooth exhibited a fractured root, despite an intact crown. One restoration was removed because of hypersensitivity and 1 with partial ceramic fracture. Forty-two of the glass-ceramic crowns were completely fractured. After a comparable 7 years under risk, 96.5% (+/-3.4; 95% confidence interval) of the galvano-ceramic premolar and molar crowns and 92% (+/- 8.5) of crowns placed on incisors and canines crowns were intact. The corresponding data for the glass-ceramic restorations were only 70% (+/- 10.6) in posterior and 82.7% (+/- 8. 1) in anterior quadrants. CONCLUSION: Long-term results of electroformed individual crown restorations were superior to glass-ceramic restorations.

Adult↗

Method for marginal measurements of restorations: accessory device for toolmakers microscope.

Standardization of measurements for marginal fit of castings is critical. This study describes the fabrication of a device that allowed fixation of specimens on a Toolmakers microscope with identical conditions according to tri-dimensional positioning of specimens, measuring location, and seating force. The device also allows mapping of the marginal discrepancies on the entire marginal perimeter of the tooth preparation.

Calibration↗

Fracture load and mode of failure of ceramic veneers with different preparations.

STATEMENT OF PROBLEM: Fracture is a clinical failure modality for ceramic veneers. Whether design of tooth preparation can affect the strength of ceramic veneers remains controversial. PURPOSE: This in vitro study evaluated fracture load and mode of failure of ceramic veneers, with 4 tooth preparation designs, that were bonded on extracted human maxillary central incisors. Identical parameters were also measured on unrestored intact teeth for comparison. MATERIAL AND METHODS: Fifty maxillary central incisors were randomly divided into 5 equal groups. Each group was assigned a different tooth preparation design: (1) no incisal reduction, (2) 2 mm incisal reduction without palatal chamfer (butt joint), (3) 1 mm incisal reduction and 1 mm height palatal chamfer, (4) 4 mm incisal reduction and 1 mm height palatal chamfer, and (5) unrestored (control). Forty teeth were prepared to accommodate ceramic veneers of equal thickness and incisocervical length. Stone dies were fabricated and veneers made from IPS Empress ceramic. Ceramic veneers were bonded and all teeth mounted in phenolic rings with epoxy resin. Fracture loads were recorded with a mechanical testing machine. RESULTS: Mean fracture loads (SD) in kgf were as follows: group 1, 23.7 (6.11); group 2, 27.4 (9.63); group 3, 16.4 (3.44); group 4, 19.2 (6.18); and group 5, 31.0 (10.38). Modes of failure were also analyzed for both ceramic veneers and teeth. One-way ANOVA with multiple comparisons revealed 3 significant subsets: groups 1-2-5, groups 4-1, and groups 3-4 (P <.05). Groups 1 and 2 had no ceramic veneer fractures; group 3 had 3 ceramic veneer fractures, and group 4 had 6 ceramic veneer fractures. CONCLUSION: Groups 1 and 2 recorded the greatest fracture loads that were comparable to an unrestored control.

Aluminum Silicates↗

Geographic distribution of porcelain veneer preparation depth with various clinical techniques.

STATEMENT OF PROBLEM: Various clinical techniques have been advocated for uniform reduction of the tooth surface before a porcelain veneer restoration. Often these techniques do not produce a consistently uniform labial reduction. PURPOSE: The purpose of this study was to identify the degree of inconsistency on a geographic scale in the depth of labial reduction for porcelain veneers, resulting from the use of 3 clinical techniques. The technique of co-ordinate metrology was used to map the variations in the depth of the preparation. MATERIAL AND METHODS: A single operator using 3 techniques (dimples as depth guides, freehand, or depth grooves as depth guides) prepared 90 noncarious, unrestored extracted teeth to receive porcelain veneers (n=30). Impressions of the prepared and unprepared teeth were scanned with a co-ordinate measuring machine. In-house software was used to color-code the plotted images on the basis of the depth of preparation. Profile measurements were also made along the mid-labial sagital plane at the mid-labial, incisal, and cervical regions, as well as along the mesial proximal and distal proximal areas along the mid-labial horizontal plane. The ideal depth range for the labial reduction was chosen to be 0.4 to 0.6 mm. One-way analysis of variance and the Bonferroni test were performed to determine the significance (P<.05) in the difference between the means of reductions achieved with the 3 techniques. RESULTS: There was no statistically significant difference in the mean percentage area prepared to the ideal depth range (0.4 mm-0.6 mm), between dimple (44.59%), freehand (36.35%), and depth groove (38.43%) techniques. The difference in the mean percentage area of reduction greater than 0.6 mm between dimple (12.98%), freehand (29.66%), and dimple and depth groove (37.32%) techniques were statistically significant (P=.0000), but not between freehand and depth groove techniques. With the profile measurements it was seen that there were statistically significant differences in the mean depth between dimple (0.45 mm) and depth groove (0.63 mm), and freehand (0.51 mm) and depth groove in the mid-buccal (P<.0004) and cervical (dimple = 0.48 mm, freehand = 0.52 mm, depth groove = 0.63 mm) (P<.0005) regions. There was statistically significant difference (P<.0000) in the mean depth between the dimple (0.39 mm) and freehand (0.30 mm), dimple and depth groove (0.50 mm), and freehand and depth groove techniques in the incisal area. In the mesial proximal region statistically significant difference (P<.0034) in the mean depth was found between the dimple (0.52 mm) and freehand (0.68 mm), and dimple and depth groove (0.64 mm) techniques only. In the distal proximal region, there was no statistically significant difference in the mean depth between dimple (0.55 mm), freehand (0.66 mm), and depth groove (0.64 mm) techniques. CONCLUSION: The use of dimple technique showed a trend to greater consistency and fidelity in labial reduction to a depth of 0.4 to 0.6 mm. The 3 techniques for veneer preparations studied were associated with varying degrees of inconsistency in the distribution of depth of preparation within a tooth and between teeth in the same technique group.

Analysis of Variance↗

Effects of two preparation designs and pontic distance on bending and fracture strength of fiber-reinforced composite inlay fixed partial dentures.

STATEMENT OF PROBLEM: Joint fractures observed in Targis/Vectris inlay adhesive fixed restorations may be related to the preparation design. PURPOSE: This in vitro study investigated the effects of the proximal tooth preparation design and the pontic distance on the fracture strength and the amount of bending of fiber-reinforced inlay adhesive fixed partial dentures. MATERIALS AND METHODS: Forty extracted premolars and 40 molars were embedded in a PMMA resin to represent a premolar and molar mesiodistal separation distance of 7 mm and 11 mm, respectively. Two preparation designs were used (proximal box and tub-shaped). The sample size was 10 for each group. Fiber-reinforced inlay adhesive fixed partial dentures were fabricated by use of the Targis/Vectris system and luted adhesively to the teeth with Variolink luting agent. A vertical force was loaded to the center of the fixed partial dentures at a crosshead speed of 1 mm/min. The initial bending (mm) prior to fracture was evaluated by measuring the distance the test rod moved from a 10 N preload to fracture. The differences in the mean fracture strength and the average amount of bending as a function of the preparation designs and pontic distances were compared by use of a 2-way analysis of variance (alpha=.05). The specimens were examined optically for the type of failure with a stereomicroscope. The fracture surface of the specimens was examined by scanning electron microscopy, and radiography was used to investigate the surface morphological features at the failure sites and to determine the fracture mode. A chi-square test was used to identify the differences in the debonding rates between the types of preparation designs and the pontic distance (alpha=.05). RESULTS: The mean fracture strength and the standard deviation of the fiber-reinforced inlay retained adhesive fixed partial denture group was 1368+/-212 N for the 7-mm tub group, 885+/-109 N for the 11-mm tub group, 1779+/-317 N for the 7-mm box group, and 1336+/-281 N for the 11-mm box group. The fracture strength was significantly higher in the 7-mm pontic distance (P<.001) and for the box-shaped tooth preparation (P<.001). The amount of bending was significantly greater in the 7-mm pontic distance (P=.025) and the box-shaped tooth preparation (P=.002). Debonding was observed only in premolar teeth and tub-shaped design groups. CONCLUSION: The box-shaped tooth preparation may be considered for restoration of a missing single posterior tooth with fiber-reinforced inlay adhesive fixed partial dentures.

Adhesiveness↗

A technique to determine a desired preparation axial inclination.

The guidelines recommended in the literature for the convergence angle of a crown preparation vary from 3 to 24 degrees. There is a lack of guidelines on techniques to achieve a specific axial inclination. The purpose of this article was to present a practical technique, with a diamond rotary cutting instrument of known axial inclination, to determine the diamond rotary cutting instrument angulations required to achieve the desired axial inclination of a preparation.

Crowns↗

Effects of relining on long-term marginal stability of provisional crowns.

Provisional resins crowns are commonly placed to protect prepared teeth, but the marginal adaptation of interim crowns has always been a problem. These experiments examined the effects of thermocycling and occlusal loading on relined and unrelined polymethyl methacrylate resin transitional crowns. Three groups of interim crowns were made on a cast metal die tooth preparation; unrelined, relined correction, and paint-on correction. After thermocycling and occlusal loading of the specimens, the change in mean marginal gap was significantly greater for the unrelined group. Axial changes were greatest for relined group and least for the unrelined group. These results suggested that relining of polymethyl methacrylate interim crowns can be useful to prevent increases in marginal gap width during extended intraoral periods.

Analysis of Variance↗

Clinical performance of resin-retained fixed partial dentures bonded with a chemically active luting cement.

A clinical study was undertaken to review resin-retained fixed partial dentures bonded with a chemically active luting cement during a 4-year period. One hundred thirty-seven fixed partial dentures were reviewed of which five had failed because of a nonbonding failure (esthetics, trauma, fracture) and 47 (36%) had failed after a bonding failure, of which 72% were rebonded. The mean time of failure was 10.9 months (SD 9.8). The failure rate appeared to be affected by position, use of a rubber dam, and the fixed partial denture design, although no one factor reached conventional statistical significance.

Chi-Square Distribution↗

Smear layer instability caused by hemostatic agents.

The effect of hemostatic agents, other than a 15.5% Fe2(SO4)3 solution, on prepared tooth structure is unknown. The purpose of this study was to (1) compare the effect of six commonly used hemostatic solutions and two nondental astringents on the dentinal smear layer and (2) determine whether different responses caused by product and/or time could be established. Standardized dentinal smear layers were exposed to eight astringent solutions for 30, 120, and 300 seconds (n = 6). A total of 144 SEM photographs at x2400 magnification were ranked according to predetermined criteria for five categories of smear layer removal and etching of underlying tooth structure. There were significant differences (p < 0.001) caused by the solution, exposure time, and their interaction. Greatest smear layer removal was observed with 21.3% AlCl3-6 hydrate, 8% racemic epinephrine HCl, and 15.5% Fe2(SO4)3 solutions at longer exposures. These caused significantly more removal than did almost pH neutral tetrahydrozoline or oxymetazoline (p < 0.05).

Acid Etching, Dental↗

Retention of metal ceramic crowns cemented with resin cements: effects of preparation taper and height.

This study investigated the effect of varying crown preparation taper and height on the retention of metal ceramic crowns cemented with resin cements. In part 1, 32 extracted molars were divided into four groups. All groups received complete-veneer crown preparations, two with a 12-degree wall angle and two with a 35-degree wall angle. Crowns were cemented with zinc phosphate and dentin-bonded resin cements. After 24 hour water storage at 37 degrees C, the crowns were separated in tension. Crowns cemented with zinc phosphate were cleaned and recemented with another dentin-bonded resin cement and after similar storage, the crowns were separated. Mean separation forces of resin-cemented crowns were higher than those of crowns cemented with zinc phosphate cement. Mean separation force of 35-degree crowns cemented with one dentin-bonded resin cement was found to be significantly higher than for the 12-degree crowns cemented with zinc phosphate cement. In part II, 32 extracted molars were divided into two groups of complete-veneer crown preparations (group I preparations were 3 mm high and group II were 5 mm high). Crowns for all teeth were cast and cemented with zinc phosphate. After 48 hours' water storage at 37 degrees C, the crowns were separated in tension. Crowns and teeth were then cleaned and each group was subdivided into 2 equal subgroups. In one subgroup of teeth with 3 mm and in one with 5 mm high preparations, the crowns were recemented with one of the two resin cement systems and the other two subgroups were recemented with the other resin cement. After 48-hour water storage, the crowns were separated. Mean separation forces of the resin-cemented crowns were greater than those of crowns cemented with zinc phosphate. Also, mean separation force of 3 mm crowns cemented with one resin cement was significantly greater than the 5 mm crowns cemented with zinc phosphate. Cohesive dentin fracture on separation was observed with some resin-cemented crowns but never with crowns cemented with zinc phosphate.

Analysis of Variance↗