[The effect of repeated adrenaline application on intraocular pressure and pupil in the rabbit (author's transl)].

The effect of single and repeated topical application of adrenaline on the intraocular pressure and pupil in the rabbit eye was studied using a 2% adrenaline borate and a commercial preparation of 2% adrenaline hydrochloride. On the first day, the hydrochloride gave a more pronounced pressure reduction and pupil diladation than the borate. This was found to be due to the benzalkonium chloride in the chloride preparation causing a better permeability of the adrenaline into the eye. From the second to the fifth day of adrenaline treatment a marked pressure decrease was found from the previous application of the day before. The following adrenaline application gave a hypertensive phase of intraocular pressure lasting two or three hours and a subsequent hypotensive phase lasting more than 24 hrs. The pupil diladation on the second and following days of treatment was not essentially different from the first day considering the observation period of two hours. The hypertensive phase could not be influenced by intravenous or intramuscular propranolol, however, the topical application of propranolol inhibited it completely. Some aspects of adrenergic regulation of the intraocular pressure are discussed.

Animals↗

Quantitative evaluation of peer review of program project and center applications in allergy and immunology.

We compared the review patterns of applications for program projects and centers in allergy and immunology, reviewed by the National Institute of Allergy and Infectious Diseases review committee, with those of individual research projects in immunology, reviewed by three Division of Research Grants study sections. A high concordance between these review groups was obtained with respect to the application approval rate, mean score, and distribution of applications in various priority score ranges. Furthermore, we observed a high degree of consensus among reviewers on the quality of many program project and center applications, especially those with priority scores between 100 and 200.

Allergy and Immunology↗

Practical applications of the microphotometric quantification of histoenzyme reactions.

There are many histochemical reactions which can be used for the accurate topographic detection of enzymes in tissues. There are also many reports of applications of these techniques in which the results have been evaluated subjectively. However, only a few of these methods have been the subject of quantification, using different methodologies, most of them based on microphotometry. A critical analysis of these procedures has generally shown that they are valid either relatively or at an absolute level. Nevertheless, the routine application of these methods is not as widespread as one might expect. In this paper, the methodological developments that have taken place in the histochemical assay of some enzymes by microspectrophotometry are reviewed briefly. The enzymes include acid phosphatase, non-specific esterase, succinate dehydrogenase and cytochrome oxidase. These methods have given consistent and useful results when applied to our experimental models of irradiated skin, and thus seem useful for various other applications. The reasons why there have been so few applications for quantitative histochemistry are also discussed together with possible ways of making its use more general.

Acid Phosphatase↗

Safety effectiveness of pesticide mixing-loading and application equipment used in 1976.

The effectiveness of currently used pesticide mixing-loading and application equipment in preventing workers from being exposed to cholinesterase (ChE) inhibiting pesticides was measured. Blood samples from workers involved in the application of pesticides in Monterey and Imperial counties of California were analyzed for ChE activity. The analyses indicated that only the mean red cell activity of mixer-loaders was significantly less than controls. Seasonal variations in ChE activity were noted for workers in Imperial County between January and August. These variations were apparently related to the toxicity of the pesticides used. A prototype, closed-transfer system used in Imperial County did not substantially reduce pesticide residues in the air around mixing-loading sites or prevent a reduction in ChE activity over that of open-transfer systems. This was attributed to inadequate training in the use of the new equipment on the part of the mixer-loaders and improperly maintained equipment. A protytype closed-transfer system used in Monterey County appeared to give some protection to mixer-loader applicators during the application season; however, the blood ChE activities of two mixer-loaders using another prototype closed system in Monterey County were severely depressed.

Agricultural Workers' Diseases↗

Safety effectiveness of closed-transfer, mixing-loading, and application equipment in preventing exposure to pesticides.

Blood cholinesterase (CHE) activities and urinary dialkyl phosphate levels of five mixer-loaders and four mixer-loader applicators, using a closed-transfer system in conjunction with mixing-loading and application equipment, were monitored over a period of 18 weeks. Airborne pesticide residues in the breathing zone during mixing-loading and the transfer of concentrated liquid pesticide from their original container to mix and spray tanks were determined along with airborne residues during ground application. Blood ChE activities of the majority of the workers increased slightly during the study with increased use of toxic organophosphates and carbamates. Urinary dialkyl phosphate levels varied between 0.02 and 2.4 ppm. During the study, the blood ChE activities of two mixer-loaders decreased and dialkyl phosphate levels of 2.4 ppm were found in the urine of one worker. An investigation indicated that the workers had failed to use the provided closed-transfer system. Airborne residues from liquid pesticides during closed transfer and mixing-loading averaged 5.8 microgram/m3, while residues from dusty powders averaged 152 microgram/m3. Airborne residues during ground application averaged 3.7 microgram/m3 during the workday. Mevinphos residues on cloth patches averaged 0.2 microgram/cm2.

Agricultural Workers' Diseases↗

Exposure of pesticide applicators to arsenic acid.

The arsenic content of long-sleeved coveralls worn by ground rig drivers, pilots, and ground crew members averaged 430, 260 and 348 mg of arsenic, respectively after being worn during the normal pursuit of the application of arsenic acid as a desiccant on cotton in Texas and Oklahoma. The average arsenic content in breathing zone air for ground rig applicators was 7.8 microgram As/m3 during the application. The applicators coveralls received only about 0.1 to 50 ml of the applied spray. The results will aid in the determination of preliminary hazards of exposure to arsenic acid spray when the expected absorption percentage of arsenic from clothing and bare skin is determined at some future date.

Agricultural Workers' Diseases↗

Parenteral application of NADH in Parkinson's disease: clinical improvement partially due to stimulation of endogenous levodopa biosynthesis.

Exogenous application of levodopa is conventionally used to equalize the striatal dopamine deficit in idiopathic Parkinson's disease (PD). The stimulation of endogenous biosynthesis of levodopa via activation of tyrosine hydroxylase (TH) has been proposed as new therapeutic concept in PD. This may be achieved by exogenous supply with the reduced coenzyme nicotinamide adenine dinucleotide (NADH). Aim of this open prospective study was to investigate (1) the efficacy of a new developed, parenteral application form of NADH on Parkinsonian symptoms and (2) the influence of bioavailability of levodopa. 15 patients, suffering from idiopathic PD (11 male, 4 female, age: 61.40[mean] +/- 10.27[SD] range: 44-74 years, Hoehn and Yahr stage: 3.03 +/- 0.69, range 2-4) received intravenous infusions of NADH (10 mg a' 30 min) over a period of 7 days in addition to conventional Parkinsonian pharmacotherapy. Parkinsonian symptoms were scored before (day 1) and after NADH treatment (day 8). Levodopa plasma levels were estimated over a period of four hours on the day before and on the first day of NADH application by HPLC. Parkinsonian patients showed a significant response, evaluated by the Unified Parkinson's Disease Rating Scale Version 3.0 (p = 0.025; Wilcoxon test). Moreover application of NADH significantly increased bioavailability of plasma levodopa (AUC, p = 0.035; Cmax p = 0.025). In conclusion NADH in used galenic form may be a potent stimulator of endogenous levodopa biosynthesis with clinical benefit for Parkinsonian patients.

Adult↗

Effects on locomotor activity after local application of D3 preferring compounds in discrete areas of the rat brain.

Compounds showing an in vitro binding preference for the dopamine D3 vs. D2 receptors were tested for effects on locomotor activity after local application in the nucleus accumbens (N Acc) and the ventral tegmental area (VTA) of the rat brain. R-(+)-7-OH-DPAT, a dopamine D3 preferring agonist, inhibited spontaneous locomotor activity over a wide dose range after injection into the N Acc. A decrease in activity over a wide dose range was also seen after local application into the VTA of both R-(+)-7-OH-DPAT and the dopamine D2 preferring agonist (+)-3-PPP. Furthermore, (+)-3-PPP produced a dose dependent increase in activity after local application into the N Acc. The putative D3 antagonist, U99194A, with a 30 fold preference for the dopamine D3 vs. D2 receptor, produced an increase in activity when injected into the N Acc. A similar pattern were seen after infusion into the lateral ventricle. Local application into the VTA did, however, not produce any significant effects. The present results support the hypothesis that dopamine D3 receptors (in contrast to the D2 receptors) are mainly postsynaptically located where they display an inhibitory action on locomotor activity.

Animals↗

[Drugs and their way of application in juvenile drug abuse. A dimension-analytical study of consumption habits].

In a sample of 382 heavy users mode and extent of drug abuse were inquired. Factor analysis of the data gave three factors named "i.v. applicated illegal drugs", "oral applicated illegal drugs" and "oral applicated medicaments" for short. Results show that attitudes of the drug users towards their drug uses are strongly influenced by the mode of application and the definitions of the drug laws, whereas pharmacological aspects and subjective effects have hardly any demonstrable importance.

Adolescent↗

Expandable metal stent application in obstructing carcinoma of the proximal colon: report of a case.

PURPOSE: The increased mortality of emergency vs. elective colonic surgery applies equally to the right and left colon. Recent interest has surrounded the application of expandable metal stenting in acute obstruction but has been confined to the left colon. We describe successful application of stenting in the right colon, allowing postponement of a particularly high-risk laparotomy. METHODS: A patient with acute bilateral iliofemoral thromboses simultaneously developed complete obstruction of the proximal transverse colon. After heparinization and under fluoroscopic control, a 10-cm-long, self-expanding Wall-stent (Schneider, Bulach, Switzerland), 22 mm in diameter, was manipulated across the obstruction. RESULTS: Immediate decompression with symptomatic relief ensued. The stent prevented obstruction during a 10-week period of anticoagulation, and repeat duplex scanning showed resolution of iliac thrombus. An elective right hemicolectomy was then performed. Postoperative course was uncomplicated, and histopathology confirmed a Dukes B carcinoma. CONCLUSIONS: This case, in which a potentially hazardous laparotomy was delayed until the operative risk improved, defines a new role for stenting in colonic obstruction and demonstrates an extension of its applicability to the right colon. Literature review found no other report of stent application in the right colon.

Acute Disease↗

Percutaneous caffeine application in the treatment of neonatal apnoea.

Topical application of caffeine for the treatment of neonatal apnoea was considered in 57 low birth weight infants (less than 1500 g birth weight). The rationale for the study was that transdermal absorption of drugs and chemical agents has been demonstrated in neonates depending on anatomical and functional immaturity of the epidermal barrier. Considering these issues we studied the efficacy of percutaneous application of caffeine using high pressure liquid chromatography (HPLC) for evaluation of its plasma levels. 2 x 7.5 mg (babies less than 1000 g, extremely low birth weight [ELBW] or 2 x 10 mg (babies greater than 1000 g, very low birth weight [VLBW]) of caffeine were applied transcutaneously in form of a gel to the abdominal skin (Standard dose = 0.06 g of gel equivalent to 10 mg of caffeine citrate). Gestational age of our patients was 29.4 +/- 1.7 weeks, mean birth weight 1025 +/- 240 g. Mean postnatal age at beginning of treatment was 25.5 +/- 18 h. Of the treated babies, 73% had serum levels in therapeutic range about 48 h after the first dose of caffeine application. After 10 doses 97% of patients had serum levels in the therapeutic range. We conclude that percutaneous caffeine application is a safe and useful approach for treatment of apnoea in VLBW and ELBW infants.

Administration, Cutaneous↗

The acceptability of computer applications to group practices.

Of the 72 identified group practices in a midwest urban environment, 39 were found to use computers. The practices had been influenced strongly by vendors in their selection of an automated system or service, and had usually spent less than a work-month analyzing their needs and reviewing alternate ways in which those needs could be met. Ninety-seven percent of the practices had some financial applications and 64% had administrative applications, but only 2.5% had medical applications. For half the practices at least 2 months elapsed from the time the automated applications were put into operation until they were considered to be integrated into the office routine. Advantages experienced by at least a third of the practices using computers were that the work was done faster, information was more readily available, and costs were reduced. The most common disadvantage was inflexibility. Most (89%) of the practices believed that automation was preferable to their previous manual system.

Computers↗

Applicability of a mobile accelerator for intraoperative radiation therapy to colorectal cancer.

PURPOSE: Intraoperative radiation therapy is reportedly effective for local control and pain relief in colorectal cancer. However, this treatment requires a large number of medical personnel, which hinders expanded use of this method. A mobile electron linear accelerator for intraoperative radiation therapy has been developed and is now commercially available. This report analyzes the applicability of this accelerator to colorectal cancer. The applicability of the mobile accelerator is analyzed based on its specifications by simulating the intraoperative radiation therapy delivered to these patients with a conventional intraoperative radiation therapy unit. METHODS: From 1987 to 1999, 49 colorectal cancer patients underwent 54 surgical resections and received intraoperative radiation therapy to 75 sites. RESULTS: The mean intraoperative radiation therapy dose for colorectal cancer with the conventional unit was 22 (range, 10-30) Gy. The mean electron energy level was 10 (range, 3-30) MEV. Applicator size ranged from 4 to 10 cm in diameter. The mobile accelerator can achieve a dose rate of 10 Gy/min and an applicator unit size range of 3 to 10 cm in diameter, facilitating intraoperative radiation therapy for colorectal cancer. The electron energy limitation (12 MEV at maximum) suggests that the indications for this machine are limited. In our experience, 30 percent of patients received intraoperative radiation therapy with electron energy levels exceeding 12 MEV. Of these cases, 81 percent had macroscopic residual tumor and 69 percent had pain. CONCLUSION: An intraoperative radiation therapy mobile accelerator can cover 72 percent of the irradiation sites covered using our conventional unit. This accelerator is useful for intraoperative radiation therapy with curative intent for patients with no or slight residual tumor. Patients with gross residual tumor and pain may not be suitable.

Adult↗

Selective suppression of forward and recurrent "rapid" inhibition by local application of picrotoxin in area CA1 of rat hippocampal slices.

Living slices of rat hippocampus were used to study the possibility of suppressing forward and recurrent "rapid" inhibition in area CA1 by local application of picrotoxin, an antagonist of ionotropic gamma-aminobutyric acid (GABAA) receptors. Application of picrotoxin to the apical dendrites increased the duration of focal potentials recorded in the radial layer (143.0 +/- 7.5%, n = 5; here and subsequently, results are presented as mean +/- error of the mean and n is the number of experiments) but had no effect on the population peak in the pyramidal layer (103.0 +/- 19.6%, n = 5). This is evidence for the existence of suppression of direct, but not of recurrent inhibition. Application of picrotoxin to the cell body layer, on the other hand, significantly increased the population peak (654.5 +/- 245.1%, n = 4) and provoked convulsive activity in neurons, demonstrating suppression of recurrent inhibition. Local application of picrotoxin was further used to study the question of how completely antagonists of glutamate ionotropic receptors sensitive to alpha-amino-3-hydroxy-S-methyl-4-isoxazole propionic acid (AMPA) suppress inhibition in solutions with low magnesium contents. This question is important for interpreting experimental data obtained from measurements of the components of excitatory postsynaptic potentials (EPSP), which depend on activation of ionotropic glutamate receptors sensitive to N-methyl-d-aspartic acid (NMDA). A number of studies have suggested that even at low concentrations, AMPA receptor antagonists suppress forward inhibition to such an extent that it has no significant effect on measurements of the NMDA component of EPSP. Our data do not contradict this suggestion.

Animals↗

An experimental study of conductive heating using a concentric double-electrode applicator.

With hyperthermia for treatment of superficial tumors in mind, a prototype applicator with two electrodes arranged concentrically on a disk was designed for efficient local heating, and a basic heating test was carried out. Frequencies as low as 200 kHz were used in order to simplify the configuration of the power device. The applicator consists of two electrodes, a circular inner electrode and another looped outer electrode, arranged concentrically. Water was passed through the applicator as a cooling mechanism; it was placed in direct contact with the target tissue to be heated and then charged with electricity. In the heating test using a phantom, oval hot spots were noted below the inner electrode. Using cooling water at 3 degrees C and 8.2 W, an isothermal line of 45 degrees C was located at a 5-mm radius circle around the central axis with 9 mm depth. A similar temperature distribution map was obtained in heating tests on the thigh muscle of a mongrel adult dog. The temperature distribution maps obtained from these tests corresponded closely with the results of theoretical analysis carried out according to the finite-element method. Since a comparatively low frequency was employed for this applicator the power device was simplified, which made adequate heating possible with low electric power. The temperature distribution map indicated that efficient local heating of superficial tumors could be achieved.

Electrodes↗

Two applications of wavelets and related techniques in medical imaging.

We present two applications of wavelet and related techniques to problems arising in medical imaging. Both make considerable use of the edge detection and classification properties of wavelet-type representations. First we describe simple and effective techniques for image denoising and contrast enhancement based on the multiscale edge representation of images. These techniques are sufficiently flexible to successfully address the varying requirements posed by several different medical imaging modalities in common use today. Experimental results are presented to illustrate the application of these techniques to various types of medical images. Next we describe adapted waveform encoding, a technique for magnetic resonance imaging. One advantage of this technique is that it can be used to efficiently encode edge features of the object being imaged. This has a particular diagnostic application in tracking heart wall thickness during the cardiac cycle, which we present along with some experimental results along this line. We also present an analysis of the signal-to-noise ratios of images formed with this technique, as this is a factor of paramount importance in MRI. The fact that wavelet schemes tend to concentrate energy near edge features makes the result rather different than that found in standard Fourier based approaches. We indicate an exciting potential application of our technique: reducing spectral leakage in phosphorus spectroscopy.

Algorithms↗

The application of insulin using the jet injector DG-77.

UNLABELLED: To avoid soreness and psychic stress following insulin injections by needle and syringe, the new jet injector DG-77 was used. It is a portable percutaneous pressure device with a spring, simple to operate which can be used to apply two different types of insulin. Thirty type 1 and type 2a diabetic patients participated in the study (10 females, 20 males). Insulin was applied using a needle and the DG-77 device in the same region of the body. A standardized questionnaire was compiled concerning simplicity of application, soreness, wish to possess the device and the possibility of acquiring it. The results obtained regarding the type of application were as follows: traditional way: glycemia: at 07(00)-8.5, 10(00)-10.5, 13(00)-7.4 mmol/l; insulinemia: at 07(00)-7.5, 10(00)-20.2, 13(00)-21.0 mU/l; jet injector: glycemia - at 07(00)-8.4, 10(00)-10.4, 13(00)-8.4 mmol/l; insulinemia: at 07(00)-2.8, 10(00)-12.3, 13(00)-20.0 mU/l, which was not statistically significant; for glycemia: at 10(00), t = 0.110, p greater than 0.05, at 13(00), t = 1.88, p greater than 0.05, and for insulinemia at 10(00), t = 0.82, p greater than 0.05, and at 13(00), t = 1.23, p greater than 0.05. IN CONCLUSION: 1) blood glucose and insulin control with the jet injector administration of insulin was equally successful as with the standard insulin application; 2) incidence of hematoma was not significant; 3) eighty-five percent of patients prefer the injector due to its simplicity of application, reduced soreness and would wish to possess the device.

Adult↗

Glycoalkaloid and nitrate content of potatoes as affected by method of selenium application.

A comparison of two methods of selenium application, banding and foliar spray, of sodium selenite (Na2SeO3) on total glycoalkaloid (TGA) and nitrate nitrogen (NO3-N) was studied during each of two consecutive years. The levels of application used were 0.0, 1.6 (0.75), 3.36 (1.5), and 5.6 (2.5) kg/ha (ppm soil). Both TGA and NO3-N were significantly reduced by application of 1.5 and 2.5 ppm of sodium selenite. Tuber selenium levels were significantly increased at all levels of application, using either banding or foliar spray, but were well below the toxic range for human consumption. Banding resulted in greater uptake of Se, and greater decreases in TGA and NO3-N as compared to foliar spray.

Alkaloids↗