PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

Basic study of a new denture base resin applying hydrophobic methacrylate monomer.

To improve the water sorption of poly(methyl methacrylate), new hydrophobic monomers, such as norbonyl and phenyl methacrylate, were studied to determine the resin with lower water sorption with no decrease in mechanical property. Water sorption of the copolymers of the hydrophobic monomers and MMA decreased with the increase in the concentration of the monomers. Compressive and bending strength of the copolymers were higher than that of PMMA, and the elastic modulus in bending was the same as that of PMMA. In addition, the transverse-deflection values satisfied ADA specifications. Dynamic mechanical thermal analysis of the copolymers showed a similar tendency to that of PMMA in spite of the introduction of bulky groups, such as norbonyl and phenyl, in the polymer molecule. The polymerization shrinkage in volume was in the following order: norbonyl < phenyl < methyl methacrylate.

Compressive Strength↗

The effects of cadmium on the structure and elastic properties of carotid arteries from rats.

Cadmium chloride (0.6 mg/kg) was injected intraperitoneally into seventy-five rats to determine if this material altered the static elastic properties of the carotid arteries. Control rats were either injected with saline or left untreated. The elastic properties were determined from cylindrical segments of artery which were distended with water of known volume. The pressure and length were measured. Experiments were done either at constant in vivo length or with the artery untethered so the length altered with pressure. Comparison of the methods allowed analysis of the role of elastin and collagen oriented circumferentially, longitudinally, of helically. The major changes occurred in the longitudinal direction. The initial part of the curve has previously been shown to be due to elastin, and the final part to collagen. Collagen increased more than elastin and muscle (as determined from point counting of trichrome-stained sections), but appeared to have the same elastic modulus as normal collagen. The major change was in the "cross-linking" between collagen fibres. This increased with time on the CdCl2 in a manner comparable to that seen with age in humans. Many of the changes were biphasic, and changes that occurred between one and four weeks on the CdCl2 were often recovered with continued treatment. The reason for this is obscure.

Animals↗

Restoring forces in cardiac myocytes. Insight from relaxations induced by photolysis of caged ATP.

Concentration jumps of intracellular ATP were produced by photolysis of P3-1-(2-nitrophenyl)ethyl (NPE)-caged ATP and were used to investigate the passive relengthening properties in unloaded cardiac myocytes. Patch-clamp pipettes in the whole-cell mode were used to voltage-clamp the myocytes and to load the cells with caged ATP while optical methods were applied to record sarcomere length or cell length simultaneously. Cell length was varied using energy deprivation contractures while intracellular Ca2+ was controlled with EGTA. At sarcomere lengths between 1.8 and 1.4 microns cellular relengthening after photolysis of caged ATP was rapid (t1/2 approximately 100 ms) and could be well described by a simple mechanical model. However, ATP jumps made at sarcomere lengths approximately 1.1 microns led to slow relengthening (t1/2 approximately seconds), comparable to the slow reextensions observed in skinned myocytes after bulk solution changes. We attribute the slow and incomplete relengthening of intact and skinned myocytes after severe rigor shortening to deformation and alteration of structural elements inside the cell. Relengthening from intermediate sarcomere lengths in intact cells is elastic and provides information about the underlying relengthening forces inside the cell. The data do not support the presence of a significant discontinuity in elastic modulus at a sarcomere length of approximately 1.6 microns expected from ultrastructural features of the sarcomeres and from observations in skinned myocytes. Our results suggest that the cell length measurements usually performed in this preparation provide an adequate description of the force produced by the unloaded cell in the steady state. The results also provide a way to estimate the error arising from viscous forces during rapid shortening.

Adenosine Triphosphate↗

Mechanical property characterization of mouse zona pellucida.

Previous intracytoplasmic sperm injection (ICSI) studies have indicated significant variation in ICSI success rates among different species. In mouse ICSI, the zona pellucida (ZP) undergoes a "hardening" process at fertilization in order to prevent subsequent sperm from penetrating. There have been few studies investigating changes in the mechanical properties of mouse ZP post fertilization. To characterize mouse ZP mechanical properties and quantitate the mechanical property differences of the ZP before and after fertilization, a microelectromechanical systems-based multiaxis cellular force sensor has been developed. A microrobotic cell manipulation system employing the multiaxis cellular force sensor is used to conduct mouse ZP force sensing, establishing a quantitative relationship between applied forces and biomembrane structural deformations on both mouse oocytes and embryos. An analytical biomembrane elastic model is constructed to describe biomembrane mechanical properties. The characterized elastic modulus of embryos is 2.3 times that of oocytes, and the measured forces for puncturing embryo ZP are 1.7 times those for oocyte ZP. The technique and model presented in this paper can be applied to investigations into the mechanical properties of other biomembranes, such as the plasma membrane of oocytes or other cell types.

Animals↗

Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus.

The long-term clinical performance of a dental implant is dependent upon the preservation of good quality bone surrounding the implant and a sound interface between the bone and the biomaterial. Good quality bone is itself dependent upon the appropriate level of bone remodelling necessary to maintain the bone density and the avoidance of bone microfracture and failure. Both processes are governed by the stress and strain distribution in the bone. In this study, a dental implant which had the same geometry as the Branemark system, but with a bioactive surface coating added to produce a direct bond to the bone, was analysed. A finite element stress and strain analysis has been carried out for a range of bone density distributions under axial and lateral loading. The predictions indicated that there was no evidence of strain shielding around the neck of the implant. With lateral loading, high values of von Mises stresses (18 M Pa) were predicted around the neck of the implant. A reduction in the elastic modulus of the bone around the neck of the implant by a factor of 16 only produced a twofold reduction in the peak stress. This resulted in stress levels capable of inducing fatigue failure in this much weaker bone. This analysis has demonstrated that it is extremely important to have good quality dense bone around the neck of the implant to withstand the predicted peak stresses of between 9 and 18 M Pa. Failure to achieve this after implantation and subsequent healing may result in local fatigue failure and resorption at the neck upon resumption of physiological loading.

Bone Density↗

[Structure and function of the arteries of very elderly people. The PROTEGER Study (Cardiovascular Prognosis and Therapeutic Optimization in Geriatrics)].

The purpose of PROTEGER, a multicenter prospective observational study, was to determine the contribution of hemodynamic, arterial, echocardiographic and biological parameters to the evaluation of individual cardiovascular risk in the elderly. The study included patients aged over 70 years hospitalized in geriatric units with overt cardiovascular disease. Cross sectional analysis of the first 194 subjects included in the study demonstrated a high rate of arterial alterations involving both structure and function. The principal alterations observed were: high pulse pressure despite normal mean systolic and diastolic pressures, frequent and diffuse arterial calcifications, reduced compliance and distensibility, increased thickness, diameter and incremental elastic modulus of the carotid and increased pulse wave velocity. Analysis of monitoring results in the PROTEGER study will demonstrate the role of hemodynamic measurements and arterial alterations in the prediction of cardiovascular risk in hospitalized elderly.

Aged↗

Steady flow and viscoelastic properties of lubricating grease containing various thickener concentrations.

The flow and viscoelastic properties of a lubricating grease formed from a thickener composed of lithium hydroxystearate and a high-boiling-point mineral oil were investigated as a function of thickener concentration. The flow properties of grease were measured using continuous shear rheometry, while the viscoelastic properties were measured using oscillatory shear measurements. The flow properties show that grease is a shear-thinning fluid with a yield stress that increases with thickener concentration. At concentrations of lithium hydroxystearate greater than 5% by volume, the storage modulus, G', was found to be greater than the loss modulus, G", with both moduli increasing with increasing thickener concentration, below this critical concentration G" was greater than G'. Slip at the wall of the measuring platens was a major problem encountered during the rheological measurement of grease, this is hardly surprising, and greases are designed to slip in their lubricating functions. Therefore the measuring platens were roughened by sandblasting and significantly higher yield values were recorded with the roughened geometries. Creep experiments were also performed. In the creep test, yield stresses of greases could be obtained. Zero shear viscosity was also calculated from the creep experiment and as a result viscosities over nine orders of magnitude were obtained. The power law index of the scaling law of the elastic modulus and yield stress with increasing volume fraction was found to be 4.7+/-0.2 suggesting that the flocculation of the particles that compose the grease is likely to be of the chemically limited aggregation variety.

Journal Article↗

Detection of early atherosclerosis in M. fascicularis with transcutaneous ultrasonic measurement of the elastic properties of the common carotid artery.

The elastic properties of 22 common carotid arteries from 13 male cynomolgus monkeys (M. fascicularis) that were fed either a high cholesterol (test) diet or a standard monkey chow (control) diet for 18 months were measured noninvasively with 5 MHz ultrasound. A B-mode image of the artery was obtained with a 32-element linear array transducer, and a single line of video ultrasonic information was selected for tracking the echoes from the adventitial side of the near wall to the lumen-intima interface of the far wall. This technique measured lumen diameter plus anterior wall thickness. The diastolic diameter (Dd) (mean +/- SEM) of the test arteries was slightly larger than controls (2.9 +/- 0.1 vs 2.5 +/- 0.1 mm), whereas the fractional diameter change from diastole to systole (DeltaD/Dd, where DeltaD = diameter change) was slightly less (0.062 +/- 0.010 vs 0.082 +/- 0.011). Direct subclavian artery pulse pressure (DeltaP) in the test animals (63 +/- 4 mm Hg) was significantly greater than in the controls (41 +/- 2 mm Hg), whereas there was no difference in diastolic pressure (85 +/- 3 vs 81 +/- 2), respectively. The pressure-strain elastic modulus Ep = (DeltaP/DeltaD) Dd was significantly greater in the test monkeys (182 +/- 33 kPa) than in the controls (73 +/- 9 kPa). Morphometric analysis of atherosclerosis revealed more connective tissue and intra- and extracellular lipids in the test arteries than in the controls. Based on the average of three cross-sections equally spaced along each common carotid artery, the intimal area and the maximal intimal thickness averaged 0.89 +/- 0.16 mm2 and 0.26 +/- 0.04 mm for the test monkeys compared to negligible intimae from the controls. Medial area also was significantly greater in the test monkeys (0.71 +/- 0.03 mm2) compared to controls (0.57 +/- 0.04 mm2). Percentage stenosis defined as intimal area/IEL area, where IEL area is that within the internal elastic lamina, showed the test arteries to have 30 +/- 5% stenosis compared to 0% for the controls. However, dilatation appeared to compensate for any loss in lumen area due to intimal thickening. In this study, significant carotid artery stiffening associated with diet-induced atherosclerosis is demonstrated. This noninvasive technique may be useful in pediatrics and in preventive medicine for the detection of arterial stiffening associated with early progressive atherosclerotic lesions.

Journal Article↗

Clearance of viscoelastic mucus simulant with airflow in a rectangular channel, an experimental study.

Interaction of mucus simulant with airflow in a rectangular channel is investigated experimentally. Two different viscoelastic gel mucus simulants are prepared by cross linking Borax with Locust Bean Gum (LBG) solution; liquid-like (LM) with lower storage modulus and semi-solid (SM). The rheological difference between LM and SM represent the qualitative change from liquid-like healthy mucus to the one with higher storage modulus found in a person with lung disease. The study concentrates on the effect of viscoelastic layer thickness and rheology on the wave formation and clearance due to its interaction with airflow. The results indicate that the onset air velocity for wave initiation reduces by increasing layer thickness. This effect is more pronounced for SM. Slowly propagating waves initiate at a lower air velocity for LM compared to SM for thinner layer thickness and this behavior reverses for a thicker layer. Although SM clears at a critical air velocity, LM does not show clearance behavior, defined as separation of layer section from rest and movement in the downstream flow direction. This seems to suggest that thicker mucus with higher elastic modulus, similar to the mucus for a person with lung disease, may clear easier with a two-phase air-liquid flow, as in cough.

Airway Resistance↗

Soft-tissue "flaws" are associated with the material properties of the healing rabbit medial collateral ligament.

This study evaluated microscopic flaws in the healing rabbit medial collateral ligament and their significance in terms of the material properties of this ligament during healing. A gap injury was created in the midsubstance of the medial collateral ligament in the right hindlimb of 15 skeletally mature (12 months old) New Zealand White rabbits. At postoperative intervals of 3, 6, or 14 weeks, histomorphometric analysis of the flaws was carried out in subgroups of animals. The medial collateral ligaments from four of the left hindlimbs (randomly selected) were used as uninjured contralateral controls. In one histologic section of each area of scar tissue and the analogous area in the controls, specified tissue flaws (blood vessels, fat cells, hypercellular areas, loose matrix, disorganized matrix, or a combination of these) were measured by four independent and blinded observers. The results showed that the mean total area of the flaws, as a percentage of the total section, and the mean area of the largest flaw decreased with healing time in each healing group but did not achieve control values by 14 weeks. Because it was not possible to test the healing medial collateral ligaments mechanically prior to measurement of the flaws (due to the destructive nature of failure testing), the data on the flaws were compared with the material strength and stiffness of a separate series of similarly injured and mechanically tested medial collateral ligaments (data published previously). A maximum likelihood statistical analysis showed a very strong functional association between the mean area of the largest flaw and the stress at failure (p < 0.004) and between the mean flaw area as a percentage of the total section area and the elastic modulus (p < 0.001). This study therefore demonstrates that it is possible to quantify material flaws in scar tissue in rabbit medial collateral ligaments, that these flaws become smaller with healing time as the scar remodels, and that flaws are functionally associated with the material properties of the ligament in this model (larger flaws with less tensile strength and more flaws with less stiffness).

Analysis of Variance↗

Mechanical properties and strength retention of carbon fibre-reinforced liquid crystalline polymer (LCP/CF) composite: an experimental study on rabbits.

A novel composite material with ultra-high flexural strength and cortical-bone-matched elastic modulus made of liquid crystalline polymer reinforced with carbon fibres (LCP/CF) is described. Cylindrical rods of 3.2 mm diameter and 50 mm length were fabricated by a preimpregnation/pultrusion method. The initial mechanical properties of the LCP/CF rods were as follows: flexural strength 448 MPa, flexural modulus 43 GPa, shear strength 164 MPa, and interlaminar shear strength 15.3 MPa. In the in vitro study the LCP/CF rods were immersed in phosphate-buffered saline of 37 degrees C for 12, 24, and 52 weeks. In the in vivo study the LCP/CF rods were implanted into the medullary cavity of both femora and subcutaneous tissue of the New Zealand White rabbits for 12, 24, and 52 weeks. The flexural strength of the LCP/CF rods at 52 weeks was 463 MPa in saline, 467 MPa in the subcutaneous tissue and 466 MPa in the medullary cavity of the femur. The flexural modulus was 44.6, 48.9 and 46.2 GPa, respectively. The corresponding shear strength values were 160, 178 and 181 MPa. We conclude that the LCP/CF is a promising material for high-load applications and the LCP/CF rods retain their initial mechanical properties in one-year follow-up in vivo and in vitro.

Animals↗

Effects of muscarinic and beta-adrenergic blockade on the aortic elastic response to epinephrine induced acute hypertension in conscious dogs.

To determine the effects of parasympathetic blockade and beta-blockade on the elastic response of aortic stiffness to vasopressive interventions, we studied 5 unanesthetised adult mongrel dogs by means of a pressure microtransducer and two ultrasonic crystals positioned at opposing sites in the proximal descending thoracic aorta which were used for diameter measurements. Systolic and diastolic changes in pressure and diameter were used to calculate Peterson and incremental elastic moduli. Acute hypertension was induced using infusions of epinephrine during the control period and later propranolol (1.5 mg/kg) plus atropine (0.2 mg/kg). Percent variations of mean aortic diameter were correlated to percent variations in mean aortic pressure in the control period and after autonomic blockade (P less than .001). The slopes of these correlations in the control group were higher than after autonomic blockade (P less than .05). Correlations were also found between Peterson and incremental elastic moduli and mean pressure in the control group and after autonomic blockade (P less than .001). The slopes of the correlations of incremental elastic modulus and Peterson's modulus versus mean aortic pressure were lower in the control group than after blockade (P less than .001). We conclude that in conscious dogs, autonomic blockade with propranolol and atropine decreased the distension and increased the stiffness of the aortic wall in response to acute hypertension mediated by epinephrine.

Acute Disease↗

On the stiffness of the natural actin filament decorated with alexa fluor tropomyosin.

Natural, phalloidin-free, actin filaments were decorated with tropomyosin made fluorescent by reaction with alexa fluor (R) 488 C(5) maleimide. The elastic modulus by stretching of these filaments was then determined and found to span between 38.2 MPa and 61.48 MPa. We tried also to determine the yield strength of the same filaments in the laser light trap operated at 920 mW, the maximum power of the apparatus. Only two out of the 10 filaments tested were broken under these conditions, yield strength being 50.5 and 55 pN, respectively.

Actin Cytoskeleton↗

Identification of the wheat seed protein CM3 as a highly active emulsifier using a novel functional screen.

Lyophilized albumin protein fractions were prepared from flour of four varieties of wheat: Triticum aestivum cvs. Mercia and Riband, Triticum aestivum var. spelta, and Triticum turgidum var. durum (Kamut). The dry powders were redissolved in sodium phosphate buffers at pH 3.0, 6.5, or 8.0 and at ionic strengths of 0.1 or 1.0 M to a concentration of 0.1% (w/v). Emulsions formed by sonication of protein solutions with n-hexadecane were aged at room temperature and separated into aqueous, interstitial, and interfacial phases. The distinct emulsion components were lyophilized and analyzed by RP-HPLC. A protein was observed to be preferentially located in the interfacial component and subsequently purified from a total albumin fraction and identified by N-terminal sequencing as CM3, an alpha-amylase inhibitor subunit. Measurement of the equilibrium surface tension of CM3 as a function of protein concentration demonstrated that it was at least as active as bovine beta-lactoglobulin, an established protein emulsifier. Furthermore, measurement of the surface dilational elastic modulus at an air/water interface demonstrated the formation of a viscoelastic film, while fluorescence and FT-IR spectroscopic measurements on adsorbed and nonadsorbed CM3 suggest that the secondary structure is essentially unchanged upon adsorption to an oil/water interface. It is concluded that functional screening is a valid approach to identify novel protein emulsifiers in complex mixtures.

Adsorption↗

Role of alcohol in the fracture resistance of teeth.

Healthy dentin, the mineralized tissue that makes up the bulk of the tooth, is naturally hydrated in vivo; however, it is known that various chemical reagents, including acetone and ethanol, can induce dehydration and thereby affect its properties. Here, we sought to investigate this in light of the effect of alcohol on the mechanical properties of dentin, specifically by measuring the stiffness, strength, and toughness of dentin in simulated body fluid and Scotch whisky. Results indicated that chemical dehydration induced by the whisky had a significant beneficial effect on the elastic modulus, strength, and fracture toughness of dentin. Although this made teeth more resistant to fracture, the change in properties was fully reversible upon rehydration. This effect is considered to be associated with increased cross-linking of the collagen molecules from intermolecular hydrogen-bonding, where water is replaced with weaker hydrogen-bond-forming solvents such as alcohol.

Acetone↗

Theoretical considerations of contraction stress.

Polymerization shrinkage of composite restorative materials causes clinical concerns because it introduces residual stresses in restored teeth. These stresses can, among other things, propagate enamel cracks, bring about microleakage, and cause postoperative sensitivity. The amount of shrinkage stress does not depend only on how much a composite contracts, but also on the elastic modulus ("stiffness") of the composite, the shape of the cavity, the established bonding between the tooth and restoration, etc. The relationships between these many factors can be described by universal physical laws. To analyze shrinkage stresses, theoretical models must be used that relate the various shrinkage properties and clinical conditions via physical laws. Models will assist us to rethink and optimize established paths to clinical success.

Composite Resins↗

Materials design in the performance of all-ceramic crowns.

Results from a systematic study of damage in material structures representing the basic elements of dental crowns are reported. Tests are made on model flat-layer specimens fabricated from various dental ceramic combinations bonded to dentin-like polymer substrates, in bilayer (ceramic/polymer) and trilayer (ceramic/ceramic/polymer) configurations. The specimens are loaded at their top surfaces with spherical indenters, in simulation of occlusal function. The onset of fracture is observed in situ using a video camera system mounted beneath the transparent polymer substrate. Critical loads to induce fracture and deformation at the ceramic top and bottom surfaces are measured as functions of layer thickness and contact duration. Radial cracking at the ceramic undersurface occurs at relatively low loads, especially in thinner layers. Fracture mechanics relations are used to confirm the experimental data trends, and to provide explicit dependencies of critical loads in terms of key variables: material-elastic modulus, hardness, strength and toughness; geometric-layer thicknesses and contact radius. Tougher, harder and (especially) stronger materials show superior damage resistance. Critical loads depend strongly (quadratically) on crown net thickness. The analytic relations provide a sound basis for the materials design of next-generation dental crowns.

Biocompatible Materials↗

Heat-induced gel formation by soy proteins at neutral pH.

Heat-induced gel formation by soy protein isolate at pH 7 is discussed. Different heating and cooling rates, heating times, and heating temperatures were used to elucidate the various processes that occur and to study the relative role of covalent and noncovalent protein interactions therein. Gel formation was followed by dynamic rheological measurements. Heat denaturation was a prerequisite for gel formation. The gelation temperature (84 degrees C) was just above the onset denaturation temperature of glycinin. The stiffness of the gels, measured as the elastic modulus, G', increased with the proportion of denatured protein. An increase in G' was also observed during prolonged heating at 90 degrees C. This increase is explained by the occurrence of rearrangements in the network structure and probably also by further incorporation of protein in the network. The increase in G' upon cooling was thermoreversible indicating that disulfide bond formation and rearrangements do not occur upon cooling.

Calorimetry, Differential Scanning↗