PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

Formation and removal of alkylthiolate self-assembled monolayers on gold in aqueous solutions.

We report the development of novel reagents and approaches for generating recyclable biosensors. The use of aqueous media for the formation of protein binding alkylthiolate monolayers on Au surfaces results in accelerated alkylthiolate monolayer formation and improvement in monolayer integrity as visualized by fluorescence microscopy and CV techniques. We have also developed an electrocleaning protocol that is compatible with microfluidics devices, and this technique serves as an on-chip method for cleaning Au substrates both before and after monolayer formation. The techniques for the formation and dissociation of biotinylated SAMs from aqueous solvents reported here may be applied towards the development of Au-based sensor devices and microfluidics chips in the future. A potential use of these devices includes the specific capture and triggered release of target cells, proteins, or small molecules from liquid samples.

Biosensing Techniques↗

On-chip magnetic bead microarray using hydrodynamic focusing in a passive magnetic separator.

Implementing DNA and protein microarrays into lab-on-a-chip systems can be problematic since these are sensitive to heat and strong chemicals. Here, we describe the functionalization of a microchannel with two types of magnetic beads using hydrodynamic focusing combined with a passive magnetic separator with arrays of soft magnetic elements. The soft magnetic elements placed on both sides of the channel are magnetized by a relatively weak applied external magnetic field (21 mT) and provide magnetic field gradients attracting magnetic beads. Flows with two differently functionalized magnetic beads and a separating barrier flow are introduced simultaneously at the two channel sides and the centre of the microfluidic channel, respectively. On-chip experiments with fluorescence labeled beads demonstrate that the two types of beads are captured at each of the channel sidewalls. On-chip hybridization experiments show that the microfluidic systems can be functionalized with two sets of beads carrying different probes that selectively recognize a single base pair mismatch in target DNA. By switching the places of the two types of beads it is shown that the microsystem can be cleaned and functionalized repeatedly with different beads with no cross-talk between experiments.

Magnetics↗

Methods to electrophoretically stretch DNA: microcontractions, gels, and hybrid gel-microcontraction devices.

The ability to controllably and continuously stretch large DNA molecules in a microfluidic format is important for gene mapping technologies such as Direct Linear Analysis (DLA). We have recently shown that electric field gradients can be readily generated in a microfluidic device and the resulting field is purely elongational. We present a single molecule fluorescence microscopy analysis of T4 DNA (169 kbp) stretching in the electric field gradients in a hyperbolic contraction microchannel. In addition, we are able to selectively pattern a crosslinked gel anywhere inside the microchannel. With an applied electric field, DNA molecules are forced to reptate through the gel and they moderately stretch as they exit the gel. By placing a gel immediately in front of the hyperbolic contraction, we bypass "molecular individualism" and achieve highly uniform and complete stretching of T4 DNA.

Bacteriophage T4↗

The effect of photomask resolution on separation efficiency on microfabricated devices.

Separation quality on glass microfluidic devices fabricated from photomasks of different optical resolutions was compared by measuring the dispersion (apparent diffusion) coefficients of a set of standard compounds separated on these devices. Currently, the channel manifolds of most microfluidic devices are patterned using chrome photomasks. A much cheaper, more robust alternative to chrome photomasks are laser photoplotted masks. The primary disadvantage to using laser photoplots is that the optical resolution of these masks is not as high as that of chrome masks, and this feature increases the side-wall roughness of etched channel manifolds patterned using such masks. The increased wall roughness may affect the fluid flow within the channels and, therefore, the separation quality. To determine the effect of increased sidewall channel roughness, microchip channel manifolds were patterned in soda lime glass using a chrome photomask and laser photoplots printed at resolutions of 620, 1240, 3100 and 6200 dots per centimetre (dpc). Separations were performed on these devices using dilute solutions of fluorescently labeled amino acids. The peak variances of the amino acids were calculated at increasing distances down the separation channel and plotted as a function of migration time. From this plot, dispersion coefficients of the analytes were measured. This allowed for a reliable, relatively easy, direct separation analysis among microchips fabricated from the various photomasks. After multiple separations using microchips fabricated from each resolution mask, we found that the change in sidewall surface roughness did not significantly affect the dispersion coefficients measured, and thus the separation quality. The lower mask resolution limit, rather, was governed by the fidelity to which the mask could capture the original CAD design.

Journal Article↗

Microfabricated polymer analysis chip for optical detection.

A coupling between multimode polymer waveguides and microfluidic channels on a polymethylmethacrylate (PMMA) capillary electrophoresis (CE)-chip for optical analytical applications has been successfully realised. This technology allows the integration of polymer optical waveguides together with hermetically sealed fluidic channels. The microchannels and waveguides are made in PMMA by the approved hot-embossing technology. The technology developed for the fabrication of polymer waveguides on the microfluidic chip offers the possibility of great flexibility in the choice of core materials, design and alignment of the polymer waveguides. The integration of polymer waveguides on an analysis chip enables highly spatially resolved optical detection without the large and expensive conventionally used apparatus. The optical properties of the analytical system developed are verified by transmission and propagation loss measurements. The results of measurements prove the suitability of the presented device for optical applications between 440 and 800 nm. This was shown with absorbance measurements of the dye Sulfanilazochromotrop (SPADNS) within 50 microm fluidic channels.

Journal Article↗

Fabrication of aligned microstructures with a single elastomeric stamp.

The fabrication of complex patterns of aligned microstructures has required the use of multiple applications of lithography. Here we describe an approach for microfabrication that encodes the two-dimensional spatial information of several photomasks onto a single elastomeric stamp by mapping each photomask onto distinct heights on the surface of the stamp. Pressing the stamp against a surface collapses the topography of the stamp such that each recessed layer contacts the surface in stepwise sequence; the greater the applied pressure, the larger the area of the stamp that contacts the surface. After contact of each new layer with the surface, we use techniques of soft lithography (microcontact printing, microfluidics, and patterning through membranes) to pattern the surfaces that contact the stamp and those that do not with inorganic, organic, or living materials. Microfabrication through the use of multilevel stamps provides a promising alternative to conventional lithography for the construction of multicomponent, aligned surfaces; these structures may find use as components of microfluidic devices or biological patterns.

Animals↗

Modular chemical mechanism predicts spatiotemporal dynamics of initiation in the complex network of hemostasis.

This article demonstrates that a simple chemical model system, built by using a modular approach, may be used to predict the spatiotemporal dynamics of initiation of blood clotting in the complex network of hemostasis. Microfluidics was used to create in vitro environments that expose both the complex network and the model system to surfaces patterned with patches presenting clotting stimuli. Both systems displayed a threshold response, with clotting initiating only on isolated patches larger than a threshold size. The magnitude of the threshold patch size for both systems was described by the Damköhler number, measuring competition of reaction and diffusion. Reaction produces activators at the patch, and diffusion removes activators from the patch. The chemical model made additional predictions that were validated experimentally with human blood plasma. These experiments show that blood can be exposed to significant amounts of clot-inducing stimuli, such as tissue factor, without initiating clotting. Overall, these results demonstrate that such chemical model systems, implemented with microfluidics, may be used to predict spatiotemporal dynamics of complex biochemical networks.

Blood Coagulation↗

Mechanistic study of solubility enhancement of nifedipine using vitamin E TPGS or solutol HS-15.

The objective of our study was to find mechanisms responsible for solubility enhancement of nifedipine in solid dispersions of vitamin E TPGS and/or solutol HS-15. Solid dispersions of nifedipine with selected polymers such as vitamin E TPGS, solutol HS-15, PEG(1,000), and lipocol C-10 of varying drug/polymer ratios were prepared by a fusion method. The solubility enhancement was found to be in the order of vitamin E TPGS > solutol HS-15 > lipocol C-10 > PEG(1,000). Lipocol C-10, with a similar hydrophilic-lipophilic value as vitamin E TPGS, showed a comparable retained solubility enhancement during saturation solubility studies but had lower dissolution profile. Overall, vitamin E TPGS showed the best solubility and dissolution performance, while solutol HS-15 and lipocol C-10 demonstrated moderate solubility enhancements. Solid dispersions of vitamin E TPGS as prepared by microfluidization technique initially showed slightly higher solubility compared with samples prepared by fusion method, but eventually it became the same as the study progressed. However, solid dispersion of solutol HS-15 as prepared by microfluidization demonstrated a significant, sustained increased in solubility over its sample when prepared by fusion method. Based on these results, we concluded that enhanced solubility using vitamin E TPGS and solutol HS-15 resulted from a partial conversion of crystalline drug to the amorphous form, increase in wettability of the drug by water soluble polymers, better separation of drug particles, micellar solubilization of drug by high concentrations of surfactant polymers, and interaction between polymer and drug at the molecular level.

Calcium Channel Blockers↗

Evaluation of the dehydration-rehydration method for production of contrast-carrying liposomes.

We measured the amounts of three types of radiographic contrast media (RCM) that could be entrapped in liposomes prepared by the dehydration-rehydration vesicle (DRV) technique. To make DRVs, one initially makes water-containing, small unilamellar vesicles, adds contrast media and lyophilizes the mixture. Upon rehydration, the DRVs re-form, passively entrapping RCM. Diatrizoate, iohexol and iotrolan proved to be entrappable in similar amounts (diatrizoate was best), but all of these amounts were less than for other small molecules, such as carboxyfluorescein (P less than 0.05). Entrapment was directly proportional to lipid concentration (r = 0.76; P less than 0.002), and inversely related to iodine concentration (r = 0.86; P less than 0.002). Under ideal conditions with neutral lipids, 19.45 +/- 9.9% of diatrizoate was entrapped, corresponding to 1.05 +/- 0.50 g I per g lipid. These values are close to those achievable for large unilamellar vesicles. Use of an automated mixing device (the Microfluidizer) in place of sonication, facilitated production of large liposome batches and improved entrapment (P less than 0.05). Computed tomography (CT) scans of rats showed 30 and 218 HU of liver and spleen enhancement, respectively, per g I/kg injected DRVs. These studies showed this method (possible augmented by the Microfluidizer) allows efficient production of contrast-carrying liposomes.

Animals↗

Production and characterization of improved liposomes containing radiographic contrast media.

The authors have investigated liposomes prepared by the reverse-phase evaporation method (REVs) and a modification of this technique that employs a microemulsifier (MREVs), for the delivery of radiographic contrast media (RCM) to the liver and spleen. The modification entailed substituting a Microfluidizer (Microfluidics Inc., Newton, MA) for the sonication step of the REV technique. The MREV procedure is amenable to large-scale production and continuous-flow operation and yields products with high RCM encapsulation. Efficiently entrapped are ionic, high-osmolar diatrizoate (24.38 +/- 2.62% versus 8.35 +/- 0.55%; MREV versus REV), and nonionic, low osmolar Iotrolan (Schering AG, Berlin, FRG) (24.84 +/- 2.13% versus 7.25 +/- 1.19%) RCM with iodine-to-lipid ratio of 1.5:1. The MREV procedure, therefore, has practical advantages over the REV method. High liver and spleen uptakes of Iotrolan-containing vesicles were noted in normal rats. The diatrizoate MREVs lost their contents on contact with serum, resulting in urinary excretion of this agent. Computed tomography values of splenic and hepatic sections, 1 hour after intravenous injection of Iotrolan MREV (500 mgI/kg), are 0.78, and 0.08 Hounsfield Units (HU)/mgI/kg, respectively (versus 0.01, and 0.006 HU/mgI/kg for free Iotrolan).

Animals↗

Monolithic microfabricated valves and pumps by multilayer soft lithography.

Soft lithography is an alternative to silicon-based micromachining that uses replica molding of nontraditional elastomeric materials to fabricate stamps and microfluidic channels. We describe here an extension to the soft lithography paradigm, multilayer soft lithography, with which devices consisting of multiple layers may be fabricated from soft materials. We used this technique to build active microfluidic systems containing on-off valves, switching valves, and pumps entirely out of elastomer. The softness of these materials allows the device areas to be reduced by more than two orders of magnitude compared with silicon-based devices. The other advantages of soft lithography, such as rapid prototyping, ease of fabrication, and biocompatibility, are retained.

Adhesiveness↗

From micro- to nanofabrication with soft materials.

Soft materials are finding applications in areas ranging from microfluidic device technology to nanofabrication. We review recent work in these areas, discuss the motivation for device fabrication with soft materials, and describe applications of soft materials. In particular, we discuss active microfluidic devices for cell sorting and biochemical assays, replication-molded optics with subdiffraction limit features, and nanometer-scale resonators and wires formed from single-molecule DNA templates as examples of how the special properties of soft materials address outstanding problems in device fabrication.

Biomedical Engineering↗

Chondrocyte intracellular calcium, cytoskeletal organization, and gene expression responses to dynamic osmotic loading.

While chondrocytes in articular cartilage experience dynamic stimuli from joint loading activities, few studies have examined the effects of dynamic osmotic loading on their signaling and biosynthetic activities. We hypothesize that dynamic osmotic loading modulates chondrocyte signaling and gene expression differently than static osmotic loading. With the use of a novel microfluidic device developed in our laboratory, dynamic hypotonic loading (-200 mosM) was applied up to 0.1 Hz and chondrocyte calcium signaling, cytoskeleton organization, and gene expression responses were examined. Chondrocytes exhibited decreasing volume and calcium responses with increasing loading frequency. Phalloidin staining showed osmotic loading-induced changes to the actin cytoskeleton in chondrocytes. Real-time PCR analysis revealed a stimulatory effect of dynamic osmotic loading compared with static osmotic loading. These studies illustrate the utility of the microfluidic device in cell signaling investigations, and their potential role in helping to elucidate mechanisms that mediate chondrocyte mechanotransduction to dynamic stimuli.

Actins↗

QPatch: the past, present and future of automated patch clamp.

The QPatch 16 significantly increases throughput for gigaseal patch clamp experiments, making direct measurements in ion channel drug discovery and safety testing feasible. Released to the market in the Autumn of 2004 by Sophion Bioscience, the QPatch originated from work done at NeuroSearch (Denmark) in the early days of automated patch clamp. Today, the QPatch provides many unique features. For example, only the QPatch includes an automated cell preparation station making several hours of unattended operation possible. The 16-channel electrode array, called the QPlate, includes glass-coated microfluidic channels for less compound absorption and, hence, more accurate IC(50) values. The microfluidic pathways also allow for very small amounts of compound used for each experiment ( approximately 5 microl per addition). Only the QPatch has four independent pipetting heads for more efficient liquid handling (especially for ligand-gated ion channel experiments). Patch clamp recordings with the QPatch match the high quality of conventional patch clamp and in some cases the results are even better. For example, only the QPatch includes 100% series resistance compensation for the elimination of false positives due to voltage errors. Finally, the modular QPatch 16 was designed with more channels in mind. The upgrade pathway to 48-channels (the QPatch HT) will be discussed.

Animals↗

Optical deformability as an inherent cell marker for testing malignant transformation and metastatic competence.

The relationship between the mechanical properties of cells and their molecular architecture has been the focus of extensive research for decades. The cytoskeleton, an internal polymer network, in particular determines a cell's mechanical strength and morphology. This cytoskeleton evolves during the normal differentiation of cells, is involved in many cellular functions, and is characteristically altered in many diseases, including cancer. Here we examine this hypothesized link between function and elasticity, enabling the distinction between different cells, by using a microfluidic optical stretcher, a two-beam laser trap optimized to serially deform single suspended cells by optically induced surface forces. In contrast to previous cell elasticity measurement techniques, statistically relevant numbers of single cells can be measured in rapid succession through microfluidic delivery, without any modification or contact. We find that optical deformability is sensitive enough to monitor the subtle changes during the progression of mouse fibroblasts and human breast epithelial cells from normal to cancerous and even metastatic state. The surprisingly low numbers of cells required for this distinction reflect the tight regulation of the cytoskeleton by the cell. This suggests using optical deformability as an inherent cell marker for basic cell biological investigation and diagnosis of disease.

3T3 Cells↗

Single particle confocal fluorescence spectroscopy in microchannels: dependence of burst width and burst area distributions on particle size and flow rate.

This article presents a non-invasive, optical technique for measuring particulate flow within microfluidic channels. Confocal fluorescence detection is used to probe single fluorescently labeled microspheres (200-930 nm diameter) passing through a focused laser beam at a variety of flow rates (100 - 1000 nL/min). Simple statistical methods are subsequently used to investigate the resulting fluorescence bursts and generate single-particle burst width and burst area distributions. Analysis of such distributions demonstrates that the average burst width and burst area decrease as particle size increases. In addition, both burst width and burst area (for a given particle size) are observed to decrease as volumetric flow rate is increased. The dependence of such distributions on particle size is proposed as a potential route to sizing single particles and molecules in microfluidic systems.

Journal Article↗

Preparation of the capillary-based microchips for solid phase extraction by using the monolithic frits prepared by UV-initiated polymerization.

A microfluidic solid phase extraction (SPE) array for sample enrichment was prepared by a simple method, a hot embossing technique. Five fused-silica capillaries (250 microm i.d., 380 microm o.d.) were partly embedded parallel in a polymethyl methacrylate (PMMA) microchip to serve as the extraction channels. Within each of the channels, a 2-mm-long monolithic porous polymer was prepared by in-situ photoinitiated polymerization. This then acted as the frit for packing of the extraction materials (octadecylsilica beads, ODS). By defining the light-exposure window on the channels, one can easily control the length and location of the polymer frits and the ODS beads can be packed at the desired location. With this method, solid phase extraction channels for microfluidic use can be easily prepared without complex fabrication of microstructures. Several SPE channels can be conveniently made in one microchip since the frits can be prepared in different channels through one polymerization; packing of the different channels can also be performed simultaneously. With the use of dilute ephedrine solutions, the sample loading capacity, linearity, and reproducibility were characterized. Coupled with the fast capillary electrophoresis separation, this microchip SPE array was applied for the detection of ephedrines in human urine.

Calibration↗