PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Nomogram”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

How big is the normal liver?

Ultrasonographic determinations of the craniocaudal dimension of the liver in the right midcalvicular line were performed on 96 healthy subjects. These values were compared to those obtained in the same individuals by two techniques of percussion, as well as the values for hepatic dullness predicted for those individuals using a popular nomogram. It was found that the traditional nomogram values, and both techniques of percussion, tended to underestimate this dimension of the liver as determined by ultrasound.

Female↗

The flow volume curve: normal standards in young subjects.

During epidemiological survey, satisfactory flow-volume data were obtained from 438 young Italian Boy-Scouts. Data from 302 non-smoking subjects (170 males and 132 females, ranging in age from 10 to 20 years) free of symptoms or history of cardiorespiratory disease were used in determining "normal" prediction equations and nomograms for peak expiratory flow (PEF), maximal expiratory flow at 75 percent (V 75%), 50 percent (V 50%), 25 percent (V 25%) of the forced vital capacity. The flow-volume curve showed for the same height and age evident intersubject variability. The prediction equations and nomograms give mean values but no information on scatter.

Adolescent↗

CT scanning phantom for normalization of infant brain attenuation.

The x-ray attenuation values of brain studied with computed tomography (CT) are strikingly affected by the ages of the subjects. Premature neonates, for example, may have brain attenuation values 20-30 H below adult values. These lower attenuation values for developing compared with adult brain can be ascribed partly to machine-related effects (beam-hardening, adult algorithms, scanning geometry, etc.). A scanning phantom made from aluminum was developed that can be used to develop a nomogram for any particular scanner from which normalized brain attenuation may be derived for any small head size. Using this nomogram, predicted neonatal attenuations are still 10-15 H higher than those actually observed in scanning neonates. The model predicts that, at the most, 3-4 H of this discrepancy can be accounted for by less beam-hardening from the lower bone attenuation of the thinner developing skull. Presumably, the rest is from a lower brain density in neonates (higher water content). By normalizing to cerebrospinal fluid (water) with special care to avoid partial-volume artifacts, one can predict attenuation values for developing brain more accurately.

Aluminum↗

Effect of right-to-left shunting on alveolar dead space.

Right-to-left shunting decreases the efficiency of carbon dioxide excretion and increases the alveolar dead space (physiological dead space minus anatomical dead space). The theoretical effects of shunting on alveolar dead space were studied, using a human blood nomogram, for different values of inspired oxygen fraction (FIO2), respiratory quotient (R), and arterial-venous oxygen content difference. An equation developed to define the relationship between alveolar dead space and shunt could be closely fitted to the nomogram data. With high levels of shunt, FIO2 and R, alveolar dead space can substantially increase above normal levels. The conditions needed for this increase are unusual but lie within the range observed in critically ill patients. A rise in dead space of this magnitude can be clinically important in the absence of effective compensatory mechanisms.

Carbon Dioxide↗

The cord blood oxygen affinity from normal human newborns: 1) A methodological approach.

A correct analysis of O2 affinity in neonatal whole blood puts some important, still unsolved problems of methodology, mainly based upon the fact that this kind of blood is a mixture of at least two major hemoglobins, i.e. 2/3 Hb-F and 1/3 Hb-A, having different affinities. Whereas adult blood mainly contains Hb-A. Within such a perspective, the Authors have checked if the empirical Davenport's nomogram, correcting the pO2s of adult blood to the same standard pH of 7.4, can also be used for neonatal blood. The answer is affirmative, and in addition the nomogram can also be replaced, with some advantage, by an only mathematical correction of the measured pO2s, in which pH differences from 7.4 (either positive or negative) are converted in proportional differences of pO2 and either added or subtracted to the values of these latter. Hb-CO level is undoubtedly higher in newborns than in non-smoker adults, but no factor for T50 calculation of neonatal blood has been till now identified. The Authors have determined a factor of -0.36, which can be obtained from the homologous (experimental) "adult" factor of -0.27, by multiplying this latter for 1.35.

Adult↗

Estimating ideal body mass in children.

An equation and nomogram to estimate ideal body mass (IBM) for establishing dosage regimens of certain drugs in children was derived from a large pediatric data base. The data were from more than 20,000 U.S. children (ages 1-17 years) included in two major surveys published by the National Center for Health Statistics. The IBM was defined as the 50th percentile weight for a given height (ht). The equation derived was IBM(kg) = 2.396e0.01863(ht), where height is in cm. The IBMs estimated from this equation were compared with estimates from three other methods, two of which were derived from an adult population. The adult methods were unsuitable for pediatric use. This equation and nomogram for estimating IBM in children should be useful in determining dosage regimens of aminoglycosides and other drugs for obese pediatric patients.

Body Height↗

Individualization of theophylline dosage using a single serum sample following a test dose.

Because formulas for theophylline requirement based on weight alone carry the risk of overdosing and toxicity, this study was designed to test a clearance nomogram for determining daily theophylline requirement after a known initial dose of theophylline. Twenty asthmatic children who had not taken theophylline for at least 36 hours fasted and were given one dose of anhydrous theophylline (5 mg/kg). Six hours later the serum level was measured and the appropriate dosage of sustained-release theophylline to achieve a serum level of 10 micrograms/ml was selected from the clearance nomogram. Three to seven days later a six-hour theophylline level was obtained. Of 20 patients, therapeutic levels of 10 to 30 micrograms/ml were achieved in 15, and the remaining five patients had levels close to this (range 6.2 to 16.0 micrograms/ml). The dosage requirement per 24 hours ranged from 10 to 32 mg/kg/24 hr. This method of determining theophylline requirements for children required measurement of the serum theophylline level only once for the determination of a safe and effective daily dose. It is especially valuable when follow-up is difficult and is a safe way to avoid serious overdosing while being certain of effective dosing.

Asthma↗

Creatinine clearance predictions in acutely ill patients.

In acutely ill patients, predicted creatinine clearance (Clcr) values [obtained using the Siersbaek-Nielsen nomogram (SNN) and ideal body weight (IBW)] were compared with actual Clcr based on measured urine creatinine concentrations. Timed urine collections were obtained from 118 patients (423 collections from 68 men, 400 collections from 50 women) before, during, and after aminoglycoside therapy. Patients were in intensive care units for management of acute exacerbations of sepsis, pneumonia, or abscess; most had other complicating conditions and were chronically ill. Urine was collected for 8 to 24 hours (70% for 24 hours) from Foley-catheterized patients. Patients were divided into low (less than 15 mg/kg/day), normal (15-25 mg/kg/day), and elevated (greater than 25 mg/kg/day) urinary creatinine excretion groups. Actual body weight (ABW) was used in some patient subgroups to explore differences between using IBW and ABW. SNN most accurately predicted Clcr in the 20% of the urine collections characterized by normal urinary creatinine excretion (Ucr). Most study patients excreted significantly less creatinine than the age-matched population tested in developing the SNN. In acutely ill patients with low Ucr, SNN overpredicted Clcr by 10-20 ml/min. SNN also overpredicted Clcr values in obese patients, but use of IBW rather than ABW improved the correlation between measured and predicted values in this subgroup. The SNN nomogram is applicable to critically ill patients if adjustments are made in predicted values. The characteristics of patients with low Ucr and the mechanism responsible for the decreased Ucr deserve further study.

Acute Disease↗

Estimating creatinine clearance in morbidity obese patients.

Estimates of creatinine clearance (Clcr), using five methods, were compared to measured Clcr in morbidity obese patients. Patients whose total body weight (TBW) was greater than or equal to 195% of their ideal body weight (IBW) and who had urinary Clcr measured with 24-hour urine collections were studied. The 12 men weighed an average of 180 kg; the 31 women averaged 138 kg. The methods studied considered a combination of the following factors: weight, age, sex, and serum creatinine. One method was a nomogram; TBW could not be used because of limitations of the nomogram. Both TBW and IBW were used in two methods that considered weight as a variable. Measured Clcr averaged 105.7 ml/min/1.73 sq m body surface area. All estimating methods using IBW significantly underestimated Clcr; all methods using TBW significantly overestimated Clcr. Two methods that did not include body weight as a variable predicted Clcr more accurately than did other methods, but there was still a significant difference between estimated and measured Clcr. None of the Clcr estimation methods is accurate in morbidly obese patients.

Adult↗

Automated and nomographic analysis of exercise tests.

A study was conducted to evaluate the validity and usefulness of a commercially available microprocessor for automated exercise ECG analysis and to develop a nomogram for estimating the severity of coronary artery disease. Results of visual analysis, automated analysis, and coronary arteriography were correlated for the 107 patients studied. Automated analysis was shown to be valid and useful. The ST integrals (area of ST depression) recorded after exercise were superior to those recorded during exercise because they manifested higher specificity and predictive value, even though their sensitivity was slightly lower. Using postexercise integrals, it was possible to differentiate mild and severe disease. From multiple-regression analysis of ST integrals, duration of exercise, and the severity of coronary artery disease, a nomogram was derived to estimate severity of coronary artery disease.

Angiography↗

[Studies of the numerical distribution of microfilariae in foci of lymphatic filariasis (author's transl)].

The frequency distribution of Wuchereria bancrofti microfilariae counts in capillary blood, at a community level, is shown to differ significantly from the log-normal distribution, commonly used (and recommended by WHO). A much better fit is obtained with a truncated negative-binomial distribution, the k exponent of which is estimated to 0.3. This value does not seem to be affected by the endemic level, by microfilaricide mass-treatments or by the blood sample volume. This result has immediate practical interests: 1) it facilitates a posteriori comparisons between surveys in which different volumes of blood were examined; 2) at a given density it allows calculation the change in sensitivity (detection rate) as a function of a change in the volume of blood examined, thus allowing better a priori planning of surveys. The paper provides the formulae required to calculate k, or, given k, to calculate the expected numbers in the various density classes. It also provides nomograms (fig. 4a & b) giving estimates of the true mean M and of the detection rate TD, given any one of the three following observations, made on observed positives: the median Dmf. 50, the mean m, or the percentage Pl having only 1 mf. The effect of changing the volume of blood on the rate of detection can then be read easily from the nomogram. These results, likely to apply to other important parasitic diseases, should instigate more elaborated statistical research in this direction.

Animals↗

The role of urodynamics in the evaluation of voiding dysfunction in men after cerebrovascular accident.

PURPOSE: The etiology of voiding dysfunction was determined in men after a cerebrovascular accident who were at risk for obstructive uropathy to evaluate whether the cause of voiding dysfunction could be predicted by the type (obstructive or irritative) or onset of symptoms. MATERIALS AND METHODS: We evaluated 38 men with complaints of voiding dysfunction following a cerebrovascular accident. All patients were of the age when bladder outlet obstruction secondary to benign prostatic hyperplasia would otherwise be prevalent. After a comprehensive history and physical examination, all patients underwent multichannel urodynamic studies at a medium fill rate (20 to 50 ml. per minute). Findings were classified by the Abrams-Griffiths nomogram as obstruction, no obstruction or equivocal. RESULTS: Mean patient age was 70 years (range 54 to 87). Patients were grouped according to the presenting voiding complaints (purely irritative in 42%, purely obstructive in 34% or mixed in 24%). In 34 patients (89%) the onset of symptoms paralleled the occurrence of the cerebrovascular accident. Detrusor hyperreflexia was noted in 82% of the patients. There was no statistically significant difference in the occurrence of detrusor hyperreflexia among the 3 symptom groups (Fisher's exact test). Pressure-flow analysis clearly showed obstruction in 24 patients (63%), no obstruction in 9 (24%) and equivocal results in 5 (13%) according to the nomogram. There was no statistically significant difference in the incidence of obstruction among the 3 symptom groups (Fisher's exact test). CONCLUSIONS: Presenting symptoms did not predict the urodynamic findings of bladder outlet obstruction or detrusor hyperreflexia. The significant incidence of onset of symptoms after stroke suggests that the cerebrovascular accident induced voiding dysfunction in the face of preexisting bladder outlet obstruction may exacerbate the symptoms of the latter condition or vice versa.

Aged↗

Correlation between urinary flow rate, voided volume, and patient age in a community-based population.

This investigation is unique in that is the first study to use a large number of randomly chosen men from the community to establish the relationship between: 1) urinary flow rate and voided volume, 2) urinary flow rate and patient age, 3) voided volume and patient age, and 4) the time to achieve peak urinary flow rate and patient age. The results clearly indicate that both the peak and mean urinary flow rate decreases with advancing age. The voided volume also diminishes with increasing age. The time required to achieve the peak urinary flow rate, however, appears to be independent of the patient's age. Irrespective of age, approximately 9 seconds are required to achieve the maximum urinary flow rate. Because the urinary flow rate is dependent upon both the quantity of urine voided and the patient's age, it is necessary to account for the influence of both parameters when establishing the "normal range" for peak urinary flow rate. To this end, nomograms estimating the peak urinary flow rate percentile as a function of voided volume and patient age have been generated and are included in this report. These nomograms, based on a large, randomly selected population, should make peak urinary flow rate a more reliable diagnostic modality for assessing bladder outlet obstruction. They also should be most useful to the practicing clinician when interpreting the results of a peak urinary flow rate determination for a patient presenting with symptoms of prostatism.

Adult↗

Life-threatening transurethral resection syndrome despite monitoring of fluid absorption with ethanol.

Ethanol monitoring is a fairly new method for assessing fluid absorption during transurethral resection of the prostate. The volume of irrigant absorbed is usually estimated from a nomogram every 10 min during the operation. We report a case in which a patient developed a transurethral resection syndrome and circulatory shock despite ethanol monitoring and adequate volume replacement. The further course of the operation showed that absorption had occurred by the extravascular route. In these cases, ethanol monitoring can be misleading as the maximum breath ethanol level occurs after a delay of 20 min and the fluid absorption is three times larger than indicated by the nomogram.

Absorption↗

The prediction of restoration of a positive overjet in unilateral cleft lip and palate.

X-ray cephalometric studies were carried out repeatedly in 92 individuals with unilateral cleft lip and palate at the age of 10 and 15 years with investigations of a possible restoration of a positive overjet in relation to the development of sagittal interalveolar relations. On the basis of this analysis was constructed a nomogram which according to the age of the patient allows to use a single easily determined X-ray cephalometric parameter for the estimation of the risk of a failure of the management aimed at the restoration of a positive overjet. The system includes critical boundaries which should be attained in the course of the treatment for the restoration of a positive overjet and it provides the possibility to check the effects of all therapeutic procedures. The simple application of the nomogram and the easy collection of data (the age and sagittal interalveolar relations) allow its use in the clinical practice as a component of the documentation on the management of the patient.

Adolescent↗

[Nomographical determination of brain wet weight of small mammals (albino rats) from weight of brain fixed in different ways].

Some nomograms have been designed, based upon albino rat brains, which are fixated by several liquids (Bouin, Carnoy, formaldehyde, Golgi-Cox according to Ramon-Moliner). These nomograms allow to determine the weight of fresh unfixated brains (HFG) in a simplified manner, if it was possible only to determine the weight of fixated brains (HT) by weighing.

Animals↗

Total porphyrin and coproporphyrin and uroporphyrin fractions in urine measured by second-derivative spectroscopy.

A second-derivative scan of an acidified urine sample allows the amplitude of deflection (delta A) and the minimum wavelength of the trough (lambda min) to determine the correct porphyrin concentration and the coproporphyrin:uroporphyrin (copro:uro) ratio, respectively, from a nomogram constructed from calibrator solutions. We measured 24 urine samples for total porphyrin as coproporphyrin equivalents and adjusted the results with factors from the nomogram. The adjusted results (x) (mean +/- SE, 501 +/- 57 nmol/L) compared favorably with the expected results (y) (514 +/- 57). The regression equation and correlation coefficient were: y = 0.993x - 8.9 (r = 0.998, S(y/x) = 16.2). Results of the copro:uro ratio derived by second-derivative spectroscopy and HPLC showed no significant difference (chi 2-test) from samples with various copro:uro ratios. Recovery studies on four urine samples supplemented with known proportions of coproporphyrins and uroporphyrins gave good agreement between the measured and the expected porphyrin ratios. The overall imprecision (CV) of the assay ranged from 3.6% to 6.0% for coproporphyrin and from 3.2% to 9.1% for uroporphyrin.

Chromatography, High Pressure Liquid↗

The effects of diabetes on penile somato-afferent system.

The direct evaluation of the autonomic nervous system to detect the neurogenic component of erectile dysfunction in men is not possible. Biothesiometry, a vibration perception test, is a simple method for the assessment of the penile somato-afferent system. A nomogram for the evaluation of somato-afferent system has been developed utilizing the biothesiometer in healthy men. This nomogram was used to compare the biothesiometric values of potent and impotent diabetic patients. According to our data, the radix penis is selectively damaged by diabetes mellitus in the first stage of the disease, whereas the glans penis is damaged later on when the disease reaches the stage of impotence.

Adolescent↗