PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

Effect of window size on detection acuity and resolution acuity for sinusoidal gratings in central and peripheral vision.

Detection and resolution of square patches of sinusoidal gratings were measured in central and peripheral vision (30 degrees horizontal temporal visual field) for high-contrast gratings as a function of the number of cycles in the stimulus. We determined performance in a forced-choice paradigm for a fixed number of stimulus cycles by arranging for stimulus diameter to vary inversely with spatial frequency. For both psychophysical tasks and for both target locations, the psychometric function relating performance to log spatial frequency shifted to higher frequencies without changing slope significantly as the number of cycles in the stimulus was increased. Thus the entire effect could be captured by an analysis of spatial acuity, which increased with increasing number of grating cycles over the range 0.5-6 cycles but remained constant over the range 6-14 cycles. In the central field, resolution acuity and detection acuity were equal regardless of the number of cycles in the stimulus. In the peripheral field, detection acuity exceeded resolution acuity and perceptual aliasing occurred for stimuli in the range 1-14 cycles. From this result we conclude that resolution acuity is sampling limited in the periphery, provided that the stimulus contains at least one full cycle of the grating. Essential features of the results could be accounted for by Fourier analysis of the stimulus.

Fovea Centralis↗

Coherent use of opposing lenses for axial resolution increase in fluorescence microscopy. I. Comparative study of concepts.

We study the use of coherent counterpropagating interfering waves to increase threefold to sevenfold the optical bandwidth and the resolution of fluorescence microscopy along the optic axis. Systematic comparison of the point-spread function and the optical transfer function (OTF) for the standing-wave microscope (SWM), the incoherent illumination interference image interference microscope (I5M), and the 4Pi confocal microscope reveals essential differences among their resolution capabilities. It is shown that the OTF's of these microscopes differ strongly in contiguity and amplitude within the enlarged range of transferred frequencies, and therefore they also differ in their ability to provide data from which interference artifacts can be removed. We demonstrate that for practical aperture angles the production of an interference pattern is insufficient for improving the axial resolution by the expected factor of 3-7. Conditions of the OTF for unambiguous improvement of axial resolution of arbitrary objects are fulfilled not at all in the SWM, partially in the I5M, and fully in the two-photon 4Pi confocal microscope.

Journal Article↗

Resolution enhancement in standing-wave total internal reflection microscopy: a point-spread-function engineering approach.

The theoretical basis for resolution enhancement in standing-wave total internal reflection microscopy (SW-TIRM) is examined. This technique relies on the formation of an excitation field containing super-diffraction-limited spatial-frequency components. Although the fluorescence generated at the object planes contains high-frequency information of the object distribution, this information is lost at the image plane, where the detection optics acts as a low-pass filter. From the perspective of point-spread-function (PSF) engineering, one can show that if this excitation field is translatable experimentally, the high-frequency information can be extracted from a set of images where the excitation fields have different displacement vectors. We have developed algorithms to combine this image set to generate a composite image with an effective PSF that is equal to the product of the excitation field and the Fraunhofer PSF. This approach can easily be extended to incorporate nonlinear excitation modalities into SW-TIRM for further resolution improvement. We theoretically examine high-resolution imaging based on the addition of two-photon, pump-probe, and stimulated-emission depletion methods to SW-TIRM and show that resolution better than 1/20 of the emission wavelength may be achievable.

Journal Article↗

Saturated patterned excitation microscopy--a concept for optical resolution improvement.

The resolution of optical microscopy is limited by the numerical aperture and the wavelength of light. Many strategies for improving resolution such as 4Pi and I5M have focused on an increase of the numerical aperture. Other approaches have based resolution improvement in fluorescence microscopy on the establishment of a nonlinear relationship between local excitation light intensity in the sample and in the emitted light. However, despite their innovative character, current techniques such as stimulated emission depletion (STED) and ground-state depletion (GSD) microscopy require complex optical configurations and instrumentation to narrow the point-spread function. We develop the theory of nonlinear patterned excitation microscopy for achieving a substantial improvement in resolution by deliberate saturation of the fluorophore excited state. The postacquisition manipulation of the acquired data is computationally more complex than in STED or GSD, but the experimental requirements are simple. Simulations comparing saturated patterned excitation microscopy with linear patterned excitation microscopy (also referred to in the literature as structured illumination or harmonic excitation light microscopy) and ordinary widefield microscopy are presented and discussed. The effects of photon noise are included in the simulations.

Computer Simulation↗

Optimal pupil size in the human eye for axial resolution.

A computer model that incorporates the monochromatic aberrations of the eye is used to determine the optimal pupil size for axial and lateral resolution as it applies to retinal imaging instruments such as the confocal scanning laser ophthalmoscope. The optimal pupil size for axial resolution, based on the aberrations of 15 subjects, is 4.30 mm +/- 1.19 mm standard deviation (sd), which is larger than that for lateral resolution [2.46 mm +/- 0.66 mm (sd)]. When small confocal pinholes are used, the maximum detected light is obtained with a pupil size of 4.90 mm +/- 1.04 mm sd. It is recommended to use larger pupil sizes in imaging applications where axial resolution is desired.

Humans↗

Increasing the lateral resolution of 4Pi fluorescence microscopes.

The axial resolution of fluorescence microscopes can be considerably improved by superposing two illumination beams and by adding coherently the two wavefronts emitted by the luminescent sample. This solution has been implemented in 4Pi microscopes. Theoretical and experimental results have shown that a considerable improvement of the axial resolution can be obtained with these microscopes. However, the lateral resolution remains limited by diffraction. We propose a configuration of a 4Pi microscope in which the lateral displacement of the source modifies the collection efficiency function (CEF). Numerical calculations based on an approximate scalar theory and on exact vector-wave-optics results of the field distribution of the electromagnetic field in image space show that the lateral extent of the CEF can be reduced by a factor greater than 2 with respect to the diffraction limit. We show that, with this solution, the resolution in the transverse plane of 4Pi type B and 4Pi type C microscopes can be improved significantly.

Computer Simulation↗

Improved-resolution digital holography using the generalized sampling theorem for locally band-limited fields.

We describe the recording conditions that, together with the appropriate numerical reconstruction process, permit high-lateral-resolution reconstruction of in-line digital holograms. By high resolution, we mean a resolution that is beyond the Nyquist frequency, which is achieved by common methods. The proposed method is based on a previously reported generalized sampling theory that presents the conditions to precisely reconstruct fields that in certain cases may be sampled with a sampling rate lower than the Nyquist rate. We examine the hologram-recording process in the Wigner space. On the basis of this analysis, we demonstrate a simple high-resolution numerical reconstruction method.

Journal Article↗

Quantitative characterization of the limiting resolution of a microscanning imager.

A method to determine the limiting resolution of a microscanning imager is proposed. Specifically, both the sample-scene phase effects and aliasing effects due to microscanning are modeled in this method by combining the pixel transfer function and the squeeze modulation transfer function. Further, this model is used to calculate the amount of improvement from typical microscanning modes to the limiting resolution of the imager focusing on various blur factors. Analytical results show that the limiting resolution of the microscanning imager is closely related to microscanning modes. The amount of improvement from different microscanning modes to the limiting resolution is different and is closely associated with the fill factor and the blur factors. The conclusion obtained will be helpful in choosing the optimum microscanning mode according to the fill factor of the detector and system blur factors.

Journal Article↗

Retinal limits to the detection and resolution of gratings.

The maximum spatial frequency for the detection and resolution of sinusoidal gratings was determined as a function of stimulus location across the visual field. Stimuli were produced directly on the retina as interference fringes, thus avoiding possible loss of image quality, which may occur when the optical system of the eye is used to form the retinal image. Contrary to earlier reports, we found that subjects could detect gratings with spatial frequencies much higher than the resolution limit. At 5 degrees of eccentricity from the fovea, the detection limit was about three times the resolution limit, and this factor increased to about 10 as the test stimulus was moved 35 degrees into the periphery. Quantitative comparison of the data with retinal anatomy and physiology suggests that pattern resolution is limited by the spacing of primate beta (midget) retinal ganglion cells, whereas pattern detection is limited by the size of individual cones.

Humans↗

Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber.

We have developed an ultrahigh-resolution optical coherence tomographic system in which broadband continuum generation from a photonic crystal fiber is used to produce high longitudinal resolution. Longitudinal resolution of 1.3-microm has been achieved in a biological tissue by use of continuum light from 800 to 1400 nm. The system employed a dynamic-focusing tracking method to maintain high lateral resolution over a large imaging depth. Subcellular imaging is demonstrated.

Animals↗

Dual-axis confocal microscope for high-resolution in vivo imaging.

We describe a novel confocal microscope that uses separate low-numerical-aperture objectives with the illumination and collection axes crossed at angle theta from the midline. This architecture collects images in scattering media with high transverse and axial resolution, long working distance, large field of view, and reduced noise from scattered light. We measured transverse and axial (FWHM) resolution of 1.3 and 2.1 microm, respectively, in free space, and confirm subcellular resolution in excised esophageal mucosa. The optics may be scaled to millimeter dimensions and fiber coupled for collection of high-resolution images in vivo.

Humans↗

Compact, low-cost Ti:Al2O3 laser for in vivo ultrahigh-resolution optical coherence tomography.

A compact, low-cost, prismless Ti:Al2O3 laser with 176-nm bandwidth (FWHM) and 20-mW output power was developed. Ultrahigh-resolution ophthalmic optical coherence tomography (OCT) ex vivo imaging in an animal model with approximately 1.2-microm axial resolution and in vivo imaging in patients with macular pathologies with approximately 3-microm axial resolution were demonstrated. Owing to the pump laser, this light source significantly reduces the cost of broadband OCT systems. Furthermore, the source has great potential for clinical application of spectroscopic and ultrahigh-resolution OCT because of its small footprint (500 mm x 180 mm including the pump laser), user friendliness, stability, and reproducibility.

Aluminum Oxide↗

Effects of device resolution on three-dimensional integral imaging.

We present the effects of a finite number of pixels in elemental images on the resolution and the depth of focus in three-dimensional integral imaging (II). We show that the number of pixels in elemental images determines not only the lateral resolution but also the depth resolution. The minimum number of pixels required in each elemental image is calculated to avoid depth-of-focus degradation. We evaluate how II system performance degrades as the number of pixels in each elemental image changes. The product of the depth of focus and the lateral resolution squared is used as the performance metric.

Journal Article↗

Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography.

A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-microm axial resolution by use of a femtosecond Cr:forsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

Animals↗

Improving the spectral resolution of wedged etalons and linear variable filters with incidence angle.

Compact spectrometers fabricated by placing a wedged etalon or a linear variable filter in front of a linear photodiode array typically do not exhibit the spectral resolution of a parallel filter of the same finesse. A theoretical analysis of the beam emerging from a wedged etalon is shown to predict a comalike aberration, explaining the loss in resolution. This analysis also predicts a focused beam waist whose axial position depends on the incidence angle, indicating that resolution can be improved by placing this waist on the detector. These results are experimentally confirmed in a multicavity linear variable filter to achieve 0.09 nm spectral resolution at 1550 nm.

Journal Article↗

Determination of the resolution of a multichannel Raman spectrometer using Fourier transform Raman spectra.

The resolution of a grating polychromator for Raman spectroscopy has been simulated by measuring spectra on a Fourier transform (FT) Raman spectrometer and selecting the FT of the apodization function so that the instrument line shape function mimics the triangular spectral slit function of the polychromator. To this end, FT-Raman spectra measured with a nominal resolution of 0.5 cm-1 were modified through the application of sinc2 apodization functions of various widths to simulate spectra measured on a polychromator at lower resolution. The success of this approach was validated using the 1085 cm-1 band of calcite. When the modified FT-Raman spectra were compared with spectra measured on a grating polychromator equipped with slits of widths 100 and 150 microns, the resolution of the polychromator was estimated to be 6.3 and 7.8 cm-1, respectively. This conclusion was verified experimentally by measuring the separation of two bands in the Raman spectrum of BaSO4 at approximately 460 cm-1.

Algorithms↗

New opportunities in micro- and macro-attenuated total reflection infrared spectroscopic imaging: spatial resolution and sampling versatility.

New opportunities exist to obtain chemical images using attenuated total reflection infrared (ATR-IR) spectroscopy. This paper shows the feasibility of obtaining FT-IR images with a spatial resolution of at least 3-4 microm using a Ge ATR objective coupled with an infrared microscope. The improved spatial resolution compared to FT-IR images obtained by the transmission method is due to the high refractive index of the ATR crystal, which gives a high numerical aperture and hence, a higher spatial resolution. FT-IR imaging with a conventional diamond ATR accessory has been investigated. This is the first time that FT-IR imaging is reported using such a versatile accessory based on a diamond ATR crystal. These results showed that a spatial resolution up to 13 microm can be achieved without the use of infrared microscope objectives. One advantage of the diamond element is that it allows pressure to be applied and hence, good contact to be obtained over the whole field of view.

Crystallography↗

Mutation scanning the GJB1 gene with high-resolution melting analysis: implications for mutation scanning of genes for Charcot-Marie-Tooth disease.

BACKGROUND: X-linked Charcot-Marie-Tooth type 1 disease has been associated with 280 mutations in the GJB1 [gap junction protein, beta 1, 32 kDa (connexin 32, Charcot-Marie-Tooth neuropathy, X-linked)] gene. High-resolution melting analysis with an automated instrument can be used to scan DNA for alterations, but its use in X-linked disorders has not been described. METHODS: A 96-well LightScanner for high resolution melting analysis was used to scan amplicons of the GJB1 gene. All mutations reported in this study had been confirmed previously by sequence analysis. DNA samples were amplified with the double-stranded DNA-binding dye LC Green Plus. Melting curves were analyzed as fluorescence difference plots. The shift and curve shapes of melting profiles were used to distinguish controls from patient samples. RESULTS: The method detected each of the 23 mutations used in this study. Eighteen known mutations provided validation of the high-resolution melting method and a further 5 mutations were identified in a blind study. Altered fluorescence difference curves for all the mutations were easily distinguished from the wild-type melting profile. CONCLUSION: High-resolution melting analysis is a simple, sensitive, and cost-efficient alternative method to scan for gene mutations in the GJB1 gene. The technology has the potential to reduce sequencing burden and would be suitable for mutation screening of exons of large multiexon genes that have been discovered to be associated with Charcot Marie Tooth neuropathy.

Charcot-Marie-Tooth Disease↗