Cost analysis of Turku University Central Hospital PACS in 1998.

Introduction of a picture archiving and communication system (PACS) into an old hospital poses several problems since the system cannot be implemented instantaneously. We analysed the costs of a halfway implemented PACS in Turku University Central Hospital (TUCH) during 1998. Manual and digital archiving in 1998 continued parallel so that only 10% reduction of film usage was achieved. A 21% increase in image manipulation and storage expenses occurred. A calculation based on potential 90% reduction of film usage and changes in the amount of personnel suggest some direct savings. Also, indirect savings due to more efficient patient treatment and the reduction of time spent in the hospital, and overhead costs of information handling are expected to lead to savings. However, these savings were not included in our calculations. When full-scale PACS is installed, equipment investments, network and digital ware maintenance costs will drop from 121 to 116% compared with traditional film archiving activity costs.

Academic Medical Centers↗

PACS developments in Europe.

Although the concept of picture archiving and communications systems (PACS) was developed in Europe during the latter part of the 1970s, no working system was completed at that time. The first PACS implementations took place in the United States in the early 1980s, e.g. at Pennsylvania University, UCLA, and Kansas City University. Some more or less successful PACS developments also took place in Europe in the 1980s, particularly in the Netherlands, Belgium, Austria, the United Kingdom, France, Italy, Scandinavia, and Germany. Most systems could be characterized by their focus on a single department, such as radiology or nuclear medicine. European hospital-wide PACS with high visibility evolved in the early 1990s in London (Hammersmith Hospital) and Vienna (SMZO). These were followed during the latter part of the 1990s by approximately 10-20 PACS installations in each of the major industrialized countries of Europe. Wide-area PACS covering several health care institutions in a region are now in the process of being implemented in a number of European countries. Because of limitations of space, some countries, for i.e. Switzerland, Denmark, Finland, Spain, Greece, as well as Eastern European countries, etc. could not be appropriately represented in this paper.

Diffusion of Innovation↗

New direction in PACS education and training.

The picture archiving and communication system (PACS) is an image information system that has become widely installed. For its successful implementation, training has been found indispensable. A review of PACS training thus far shows major emphasis was placed on the use of display workstations. As an integrated system, the PACS is much broader than the display workstations, having many components that need connectivity and customization. With the many potentials of further development, a more comprehensive education program on PACS is called for and a PACS simulator as a standalone training and research tool is deemed necessary.

Computer Simulation↗

Measurement of image quality in diagnostic radiology.

The aim in radiology is to obtain images which are adequate for the clinical purpose with the minimum radiation dose to the patient. If optimum performance is to be achieved, assessments of image quality must be made to balance against patient dose. The subjective nature of image interpretation makes an objective approach to such assessment difficult. Methods widely applied involve the use of test objects, which although providing a measure of imaging performance may be difficult to link to clinical image formation. The ideal method for evaluation of imaging techniques is through clinical trials and this should be used to address major questions. Scoring of quality criteria, relating to features observed in a normal clinical radiograph, provides a simple method through which image quality can be assessed in every hospital department.

Clinical Trials as Topic↗

Computed radiography X-ray exposure trends.

RATIONALE AND OBJECTIVES: Computed radiography provides correct optical density on film, independent of the incident radiation exposure, but it can result in under- or overexposure of the imaging plate. In the current study, we evaluated the radiation exposure trends of computed radiography over a 2-year period for portable chest examinations to determine and compare the radiographic techniques of the computed radiography system relative to conventional screen-film detectors. METHODS: A Fuji computed radiography system was interfaced to a digital workstation to track system usage and examination demographics, including examination type and sensitivity number. Hard-copy films were used for diagnosis. The sensitivity number, a value inversely related to incident exposure on the imaging plate, was used to determine whether the proper techniques were used by the technologists. RESULTS: The initial use of the computed radiography system revealed a broad distribution of exposures being used; complaints regarding noisy films (e.g., underexposure) resulted in subsequent overexposure for a significant number of films. A quality-control audit indicating excessive exposure resulted in educational feedback and a tighter distribution of exposures within the optimal range as determined by our radiologists. The average technique was approximately equivalent to a 200-speed system. CONCLUSION: Computed radiography provides excellent dynamic range and rescaling capabilities for proper film optical density, and thus fewer repeat examinations. However, underexposure results in suboptimal image quality that is related to excessive quantum mottle. Overexposure requires film audits to limit unnecessary radiation exposure. In general, the optimal exposures are achieved with approximately 1.5-2 times the incident detector exposure of a 400-speed rare-earth system. The ability of computed radiography to reduce radiation exposure is unlikely when compared with a typical rare-earth screen-film combination (400 speed) in terms of adequate image quality for the diagnosis of subtle, low-contrast findings. For certain diagnostic procedures (e.g., nasogastric tube placement verification), lower exposures can be tolerated.

Humans↗

Diagnostic imaging pathways: development, dissemination, implementation, and evaluation.

ISSUE: There are signs of inappropriate application of medical imaging to diagnosis. Inappropriate imaging is a threat to effective diagnosis and effective allocation of resources. The development and deployment of knowledge-based clinical decision support systems is one strategy to reduce inappropriate imaging. DEVELOPMENT OF IMAGING PATHWAYS: A suite of 78 imaging pathways was conceived both as a decision support and educational tool. The pathways were drafted by imaging specialists, but further developed and modified, based on graded evidence and input from requesting clinicians. An electronic environment was developed to contain and deliver the pathways. DISSEMINATION AND IMPLEMENTATION: Imaging pathways were distributed via a hospital local area network and on compact disk. A multifaceted approach was used to raise general awareness of the pathways, followed by intensive 'marketing' activities. Two groups of clinicians were targeted; hospital-based clinicians and general practitioners. EVALUATION: There was increased awareness of imaging pathways. Clinicians judged them to be useful for education and decision support. The method of electronic delivery was adequate. Knowledge of diagnostic imaging and requesting behaviour tended to become more aligned with the pathways. The central objective to reduce inappropriate medical imaging seems to be achievable. LESSONS LEARNED: There is scope to improve the content and the electronic environment, achieve better integration into decision-making processes, and achieve better compliance. A linkage between imaging pathways and electronic requesting could provide alerts to 'non-compliant' requesting. The assignment of a higher cost, or a lower remuneration, to non-authorized and non-compliant imaging would provide tangible incentive to comply, unless there are compelling clinical contraindications.

Attitude of Health Personnel↗

Quality control of equipment used in digital and interventional radiology.

Digital and interventional radiology are increasingly important areas of radiology. Quality control (QC) of such equipment is of particular importance to avoid unnecessary high doses and to help to achieve good image quality. Within the DIMOND III project, equipment requirements and specifications for digital and interventional radiology have been formulated. A protocol for QC tests has been drafted based on various national and international recommendations. Tests are included for various parts of the imaging chain, i.e. X-ray tube and generator, X-ray tube control system, laser printer and display station, and image quality and patient dose. Preliminary tolerance levels have been set for the various tests, after initial measurements. To check the suitability of QC tests and stated tolerance levels, measurements were made at the University Hospital Gasthuisberg in Leuven for equipment used for paediatric radiology and a unit used for chest examinations. The results of the various tests are reported.

Humans↗

Guidelines for establishing a technical support group for the radiation therapy clinic.

During the last decade, radiation therapy has grown to become an important medical treatment in the treatment of cancer. The growth of this field has created a need for an electronic and mechanical support group to service the needs of the treatment centers (clinics). Because of the uniqueness of equipment, the maintenance criteria are somewhat different than that for other types of equipment. The information for this paper was derived from five years of experience that the Mallinckrodt Institute has accumulated through its own technical group plus information gained through discussions with other groups in the therapy field. The technical support group at Mallinckrodt Institute of Radiology (MIR) presently maintains six high-energy therapy machines, two simulators, and a superficial X-ray unit. Topics discussed include the technical personnel required, the duties of the group, working hours, suggested electronic/mechanical equipment, and other pertinent aspects.

Equipment and Supplies, Hospital↗

Digital mobile radiography.

A storage phosphor digital imaging system has been used to perform virtually all of an increasing number of mobile (portable) projectional roentgenographic examinations in a busy hospital. Approximately 130 such studies are done per day, of which about 110 are chest examinations. The processing unit suffices to keep pace with peak activity in the radiology department. This technique has decreased the repeat rate for portable anteroposterior chest radiographic examinations from 4.5% to less than 1% and has resulted in an even more dramatic reduction in the rate for lateral or decubitus chest examinations as well as for studies of the abdomen and those done in the operating room. The diagnostic accuracy and confidence level achieved in interpreting the complementary pair of digital images has been equivalent to or has exceeded that obtained with conventional mobile analog film-screen radiographs.

Equipment Design↗