PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Alpha Particles”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Radon exhalation rate from various building materials.

Solid-state alpha-track detectors using cellulose nitrate films were used to measure the radon exhalation rates from building materials. The radon flux emitted from the surface of the building material was measured by placing an inverted cup on the top of the building material. Cellulose nitrate film was placed within the cup. Tracks due to alpha particles from radon that migrate from the building material into the air space in the cup were registered on the cellulose nitrate film. The films were etched in a solution consisting of 10(-3) m3 2.5 N NaOH solution. A spark counter or microscope was used to record the tracks appearing on the cellulose nitrate film. The average exhalation rate of radon was obtained by means of a simple mathematical approach that can be used to estimate the maximum possible radon concentration in a closed room due to building materials alone. Infiltration and ventilation effects were excluded in this work. This new technique and simple approach can be used to establish the data base for average radon exhalation rates from all available building materials and walls or floors. The maximum indoor radon concentration can be estimated from the measured average radon exhalation rate by using this simplified model.

Air Pollution, Indoor↗

The significance of dose rate in assessing the hazards of domestic radon exposure.

Both miner-based epidemiological data and animal studies suggest that lung cancer induction from radon-progeny alpha-particle exposure depends on the exposure rate, and increases as the exposure rate decreases. This phenomenon has been interpreted to imply that radon risks per unit dose from domestic exposure (which occur at low exposure rates) will be underestimated by risk estimates derived from miner studies (which are at higher exposure rates). There is, however, another variable affecting this phenomenon, namely the absolute cumulative exposure to radon progeny. On basic biophysical grounds, it is argued that when the cumulative exposure is sufficiently low that multiple traversals of target cells are rare, the exposure rate effect disappears. This is the case for typical domestic radon exposures but not for most miner exposures; thus, although risk estimates from miner data refer to higher dose rates, based on dose rate consideration alone they may well overestimate, rather than underestimate, domestic radon risks. Although the data are limited, both miner-based epidemiological data and animal studies appear to follow the trend described here.

Air Pollution, Indoor↗

The Auger electron effect in radiation dosimetry.

The Auger electron effect is of importance in radiation protection related to work in radiobiology, radiophysics, and nuclear medicine. Radionuclides that emit Auger electrons are widely used in nuclear medicine (99mTc, 123I, and 201Tl) and in biomedical research (51Cr and 125I). They are also present in the environment (40K). Therefore, calculation of the absorbed dose and equivalent dose to tissues from these incorporated radionuclides is important for risk assessment. Depending on the subcellular distribution of the radionuclide, the biological effects caused by cell-incorporated Auger emitters can be as severe as those from high-linear energy transfer (LET) alpha particles. However, the recently adopted recommendations of the International Commission on Radiological Protection in Publication No. 60 do not provide guidance on calculating the equivalent dose for these radionuclides. A better understanding of the effects of Auger electrons is required to estimate the equivalent doses, and further research in this field is appropriate. There are good reasons to consider the Auger electron effect not only in medical radiation protection of patients but also in the context of annual limits of intake for workers and the public.

Animals↗

State-of-the-art instruments for measuring radon/thoron and their progeny in dwellings--a review.

Radon and radon progeny measurements are conducted world-wide for the assessment of the radiation dose to workers and the general public. In the last 10 years, a variety of instruments have been developed that utilize different principles of detection for different measurement applications. The various instruments and methods used today depend on whether radon or radon/thoron progeny are being measured, the type of radiation being detected, and also the duration of the measurement. Other important design criteria are applicability, portability, convenience, reliability, and cost considerations. The instruments under consideration use the following detection systems: pulse ionization chambers, electret ionization chambers, scintillation detectors with zinc sulfide ZnS(Ag), alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, registration of nuclear tracks in solid-state materials, and gamma-ray spectometry with NaI(TI) scintillation crystals or germanium lithium (GeLi) semiconductors. Discussed in this paper are the advantages and disadvantages of the various portable instrumentation used for measuring radon, thoron, and their progeny. Also provided is guidance for their application in the field.

Housing↗

The present system of quantities and units for radiation protection.

The International Commission on Radiation Units and Measurements has over the last decade developed operational quantities, the ambient, directional and personal dose equivalent, suitable for the measurement of radiation fields in a variety of circumstances. Experience with the use of these quantities to represent the dose limitation quantities defined by the International Commission on Radiological Protection in 1977 has been an important part of recent radiation protection metrology. The definition by International Commission on Radiological Protection in 1991 of new limitation quantities, the equivalent dose and the effective dose has necessitated a redirection of this work. The metrology field has made good progress, however. It has found that for photons, at least above 50 keV, the effective dose can be measured by the ambient dose equivalent about as well as the former effective dose equivalent. Unfortunately, for neutrons the existing and already quite severe complications have been made somewhat worse by the new quantities although not any worse in the important region between 0.1 and 1 MeV. Neutron measurements over a broad energy range are the subject of extensive evaluation and some new suggestions as the metrology field wrestles with these problems. Values of wR constitute an important part of the International Commission on Radiological Protection recommendations. A brief history of the development of higher relative biological effectiveness values for fission neutrons and alpha particles leading to the selection of 20 for wR in each case, is provided.

Dose-Response Relationship, Radiation↗

Carcinogenic risk coefficients at environmental levels of radon exposures: a microdosimetric approach.

We report a microdosimetric-based evaluation of the effects of domestic exposure to radon. The risk coefficients obtained here are based on the microdosimetry of radon progeny alpha particles, on a function q(y) for in vivo radiogenic neoplasia, and on scaling A-bomb results (epidemiology + microdosimetry) to radon exposure. We do not use miner data, nor do we invoke such notions as quality factors, dose equivalent or equivalent dose. With basal cells as targets our estimated risk coefficients are in good agreement with the miner data, and thus a quality factor of about 20 (as suggested by ICRP 60) is not unreasonable. However, if we take as targets the secretory cells our risk coefficients are twice as large as those reported by BEIR-IV. The main uncertainty in these estimates remains the dosimetric model.

Carcinoma, Bronchogenic↗

A nuclear mass spectrometer for studying radon progeny clusters.

A Nuclear Mass Spectrometer (NMS) system was developed and used to investigate the cluster formation of radon progeny (218Po) in gaseous H2O and H2O-SO2 environments. This NMS combines the mass-separation ability of a mass spectrometer and the low detection limit of a surface barrier detector for alpha particles and enables the detection of individual radon progeny cluster ions of defined mass at the molecular level. Clusters in the form of 218Po+(H2O)n were experimentally observed for 218Po at a relative humidity of 0.1%. The number n ranged from 1 to 7 with 4 being the most abundant peak under these conditions. No charged cluster of 218Po was detected when the relative humidity was 90%, possibly due to a neutralization process. On addition of SO2 at a low relative humidity, 218Po+(H2O)n (H2SO4)m clusters were experimentally detected for the first time by the NMS system in this study with n from 0-4 and m from 0-3. The maximum distribution occurs at a radius of about 3.65 angstrom or a mobility of about 2.00 cm2 V-1 s-1. These maximum clusters correspond to a composition of 218Po+(H2SO4)2 or 218Po+(H20)2 (H2SO4)1.

Mass Spectrometry↗

Relative performance of different types of passive dosimeters employing solid state nuclear track detectors.

Radon and its progeny, known to be carcinogenic, are a matter of great concern in underground mines and energy conserved air-tight houses. Different shapes of dosimeters using solid state nuclear track detectors (SSNTDs) have been devised to measure radon concentrations in mines and dwellings. Sometimes intercomparison of results is required by various laboratories working with solid state nuclear track detector-based passive dosimeters. The present work includes the determination of various parameters for a set of dosimeters consisting of (1) box-type, (2) pen-type, (3) tube-type, (4) Karlsruhe Diffusion Chamber, and (5) bare-type dosimeters. In this research two types of plastics, allyl-diglycol-carbonate (C12H18O7) and cellulose nitrate (C6H8O8N2) known as CR-39 and CN-85, respectively, have been employed. The detection efficiency for alpha particles from radon and its progeny for CR-39 and CN-85 have been compared. All experiments have been carried out in a custom-designed exposure chamber connected to a radon source. The calibration factors, in terms of Bq m(-3) per unit track density (1.0 cm(-2)) with respect to box-type dosimeter, have been determined for intercomparison and standardization of measured radon concentrations by a set of passive radon dosimeters used in various laboratories of the world.

Collodion↗

An instrument for measuring equilibrium-equivalent 222Rn and 220Rn concentrations with etched track detectors.

To simultaneously measure both 222Rn and 220Rn progeny concentrations, a new type of portable integrating monitor with allyl diglycol carbonate (CR-39) plastic detectors was developed. The monitor gives the average equilibrium-equivalent 222Rn and 220Rn concentrations (EEC(RN) and EEC(Tn)) during sampling intervals. The detection efficiencies of the alpha particles were calculated by Monte Carlo method. The lower limits of detection for EEC(Rn) and EEC(Tn) are estimated to be 0.57 Bq m(-3) and 0.07 Bq m(-3) for 24 h continuously sampling at a flow rate of 0.8 L min(-1). The measuring results with the new type monitors were confirmed through intercomparison experiments. In a small survey, a rather high 220Rn progeny concentration with an average of 1.73 Bq m(-3) was observed in traditional Japanese dwellings with soil/mud plastered walls. On the other hand, a very high 232Th concentration in soil was reported in China. They suggested that there is a possibility of high 220Rn progeny concentration in both Japan and China.

Air Pollution, Indoor↗

Monte Carlo calculations of LR115 detector response to 222Rn in the presence of 220Rn.

The sensitivities (in m) of bare LR115 detectors and detectors in diffusion chambers to 222Rn and 220Rn chains are calculated by the Monte Carlo method. The partial sensitivities of bare detectors to the 222Rn chain are larger than those to the 220Rn chain, which is due to the higher energies of alpha particles in the 220Rn chain and the upper energy limit for detection for the LR115 detector. However, the total sensitivities are approximately equal because 220Rn is always in equilibrium with its first progeny, which is not the case for the 222Rn chain. The total sensitivity of bare LR115 detectors to 222Rn chain depends linearly on the equilibrium factor. The overestimation in 222Rn measurements with bare detectors caused by 220Rn in air can reach 10% in normal environmental conditions. An analytical relationship between the equilibrium factor and the ratio between track densities on the bare detector and the detector enclosed in chamber is given in the last part of the paper. This ratio is also affected by 220Rn, which can disturb the determination of the equilibrium factor.

Environmental Monitoring↗

Influences of parameter uncertainties within the ICRP-66 respiratory tract model: regional tissue doses for 239PuO2 and 238UO2/238U3O8.

This paper extends an examination of the influence of parameter uncertainties on regional doses to respiratory tract tissues for short-ranged alpha particles using the ICRP-66 respiratory tract model. Previous papers examined uncertainties in the deposition and clearance aspects of the model. The critical parameters examined in this study included target tissue depths, thicknesses, and masses, particularly within the thoracic or lung regions of the respiratory tract. Probability density functions were assigned for the parameters based on published data. The probabilistic computer code LUDUC (Lung Dose Uncertainty Code) was used to assess regional and total lung doses from inhaled aerosols of 239PuO2 and 238UO2/238U3O8. Dose uncertainty was noted to depend on the particle aerodynamic diameter. Additionally, dose distributions were found to follow a lognormal distribution pattern. For 239PuO2 and 238UO2/238U3O8, this study showed that the uncertainty in lung dose increases by factors of approximately 50 and approximately 70 for plutonium and uranium oxides, respectively, over the particle size range from 0.1 to 20 microm. For typical exposure scenarios involving both radionuclides, the ratio of the 95% dose fractile to the 5% dose fractile ranged from approximately 8-10 (corresponding to a geometric standard deviation, or GSD, of about 1.7-2) for particle diameters of 0.1 to 1 microm. This ratio increased to about 370 for plutonium oxide (GSD approximately 4.5) and to about 600 for uranium oxide (GSD approximately 5) as the particle diameter approached 20 microm. However, thoracic tissue doses were quite low at larger particle sizes because most of the deposition occurred in the extrathoracic airways. For 239PuO2, median doses from LUDUC were found be in general agreement with those for Reference Man (via deterministic LUDEP 2.0 calculations) in the particle range of 0.1 to 5 microm. However, median doses to the basal cell nuclei of the bronchial airways (BB(bas)) calculated by LUDUC were found to be approximately 6 times higher than LUDEP reference doses. The higher BB(bas) doses were directly attributed to discrepancies between the ICRP default thickness for the bronchial epithelium (55 microm) and the probability density function assumed within LUDUC (uniform distribution from 20 to 60 microm based upon detailed literature reviews).

Adolescent↗

Chronic diffuse interstitial fibrosis of the lung in uranium miners.

Many uranium miners have been disabled by and died of pulmonary fibrosis that was not recognized as an occupational disease. A review of animal studies, complications from whole body irradiation, pulmonary function, and mortality studies of uranium miners led us to suspect radiation-induced chronic diffuse interstitial fibrosis in miners who had inhaled excessive radon progeny. A selected group of uranium miners (22) with severe respiratory disease (but no rounded nodules in chest films) were studied. Lung tissue from five disclosed severe diffuse interstitial fibrosis, with "honeycomb lung" in all. Some also had small anthrasilicotic nodules and birefringent crystals. Although quartz crystals probably contributed, we concluded that the predominant injurious agent in these cases was alpha particles from radon progeny. This disease, after a long latent period, usually results in pulmonary hypertension, shortness of breath, and death by cardiopulmonary failure.

Adult↗

Advances in immunotherapy of hematologic malignancies: cellular and humoral approaches.

Monoclonal antibodies have become an important modality for cancer therapy. Genetically engineered chimeric and humanized antibodies have demonstrated activity against overt lymphoma and leukemia, as well as minimal residual disease. Radioimmunotherapy in both nonmyeloablative and myeloablative regimens has produced significant responses and also minimized radiation exposure to normal tissues. Targeted alpha-particle therapy offers the possibility of selective tumor cell kill. Antibody-drug conjugates have produced remissions in acute leukemia. Many proteins potentially act as leukemia or lymphoma-specific antigens for major histocompatibility complex-restricted T cell cytotoxicity. These include the idiotype proteins, breakpoint cluster region (bcr)-abl and other fusion oncoproteins, myeloid-specific differentiation antigens and minor histocompatibility antigens. Clinical trials exploiting the new understanding of the T cell immunology are underway.

Antibodies, Monoclonal↗

Coherent bremsstrahlung in the alpha + p system at 50 MeV/nucleon

Photons originating from coherent bremsstrahlung have been measured over a large dynamic range for the reaction of 200 MeV alpha particles with protons. At low photon energies the bremsstrahlung spectrum exhibits the classical behavior with an approximate 1/E(gamma) shape. At higher photon energies there is a pronounced contribution from capture into the unbound ground state and first excited state of 5Li. These results allow one, for the first time, to test theoretical models for a consistent description of bremsstrahlung and radiative capture in a complex system. Calculations predict both features qualitatively but fail to account for their relative importance.

Journal Article↗

Low-energy measurement of the 7Be(p,gamma)8B cross section.

We have measured the cross section of the 7Be(p,gamma)8B reaction for E(c.m.) = 185.8, 134.7, and 111.7 keV using a radioactive 7Be target (132 mCi). Single and coincidence spectra of beta+ and alpha particles from 8B and 8Be* decay, respectively, were measured using a large acceptance spectrometer. The zero energy S factor inferred from these data is 18.5+/-2.4 eV b and a weighted mean value of 18.8+/-1.7 eV b (theoretical uncertainty included) is deduced when combining this value with our previous results at higher energies.

Journal Article↗

Control of neoclassical tearing modes by sawtooth control.

The onset of a neoclassical tearing mode (NTM) depends on the existence of a large enough seed island. It is shown in the Joint European Torus that NTMs can be readily destabilized by long-period sawteeth, such as obtained by sawtooth stabilization from ion-cyclotron heating or current drive. This has important implications for burning plasma scenarios, as alpha particles strongly stabilize the sawteeth. It is also shown that, by adding heating and current drive just outside the inversion radius, sawteeth are destabilized, resulting in shorter sawtooth periods and larger beta values being obtained without NTMs.

Journal Article↗

r-Process nucleosynthesis without excess neutrons.

Matter expanding sufficiently rapidly and at high enough entropy per nucleon can enter a heavy-element synthesis regime heretofore unexplored. In this extreme regime, more similar to nucleosynthesis in the early universe than to that typical in stellar explosive environments, there is a persistent disequilibrium between free nucleons and abundant alpha particles, which allows heavy r-process nucleus production even in matter with more protons than neutrons. This observation bears on the issue of the site of the r process, on the variability of abundance yields from r-process events, and on constraints on neutrino physics derived from nucleosynthesis.

Journal Article↗

Demonstration of fusion-evaporation and direct-interaction nuclear reactions using high-intensity laser-plasma-accelerated ion beams.

Heavy-ion induced nuclear reactions in materials exposed to energetic ions produced from high-intensity (approximately 5 x 10(19) W/cm(2)) laser-solid interactions have been experimentally investigated for the first time. Many of the radionuclides produced result from the creation of "compound nuclei" with the subsequent evaporation of proton, neutron, and alpha particles. Results are compared with previous measurements with monochromatic ion beams from a conventional accelerator. Measured nuclide yields are used to diagnose the acceleration of ions from laser-ablated plasma to energies greater than 100 MeV.

Journal Article↗