PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “DIAGNOSIS, LABORATORY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

[Prevalence of toxoplasmosis and methods for its laboratory diagnosis].

The review presents data on the prevalence of toxoplasmosis in different countries and regions. It gives a comparative assessment of the methods of serodiagnosis of toxoplasmosis, which permit identification of specific immunoglobulins G, M, A, and E. The authors show a role of laboratory diagnostic techniques in the differentiation of the acute form of toxoplasmosis from its chronic form. They provide the currently available modifications of the basic procedure for enzyme immunoassay, molecular genetic methods, and a direct fluorescent antibody test for the detection of Toxoplasma gondii antigens. The current view of a cellular immune response and its role in monitoring the development of toxoplasmosis are considered.

Animals↗

Laboratory diagnosis.

Diagnosis of internal parasitism is based on many factors, including clinical signs, case histories of individual animals and the herds of which they are a part, and, finally, specific laboratory findings. Laboratory methods used can be divided into those associated with the qualitative and quantitative examination of feces for parasite eggs, larvae, and oocysts, and laboratory findings on changes in physiologic status of individuals that may be produced by specific parasites.

Animals↗

Laboratory diagnosis of community-acquired lower respiratory tract infection.

This article has focused on the evaluation of outpatients with lower respiratory illness. In large part, the need for microbiological work-up is host-dependent. Healthy patients usually do well, and laboratory data are often unnecessary. The abnormal host requires a different approach and, in general, the more compromised the host, the more aggressive the laboratory evaluation. A renal transplant patient with respiratory symptoms often follows the dictum that "common things happen commonly;" however, the clinician needs that extra level of assurance in this case. Some transplant patients may have respiratory illness caused by strongyloidiasis. Cystic fibrosis is another example of the need for a more comprehensive laboratory evaluation. Specialized selective media and additional susceptibility studies may be needed to evaluate isolates associated with exacerbation of symptoms in these patients. The clinical laboratory should be forewarned of any materials coming from invasive diagnostic techniques, so they can prepare and offer useful advice regarding specimens, transport, and follow-up. Microbiological laboratories are often most knowledgeable regarding what type of testing is appropriate. Direct communication with the laboratory is essential to assure the best patient care.

Bacterial Infections↗

Improving the laboratory diagnosis of TB in Ghana: the impact of a quality assurance system.

SETTING: Greater Accra region, Ghana. OBJECTIVE: To establish a pilot quality assurance (QA) system in sputum smear microscopy and to evaluate its impact. DESIGN: Quarterly supporting visits were paid to participating laboratories between 2000 and 2002. Fifteen examined slides were selected randomly from each laboratory during the visits and blindly re-assessed. Feedback was given promptly to the various laboratories. Training and stakeholder workshops were organised whenever necessary. RESULTS: General improvements in smear preparation and staining as well as the reading ability of the laboratory personnel included in the study were observed. The average marks for specimen quality, staining ability, smear cleanness, thickness, size and evenness increased from 64%, 79%, 69%, 46%, 67% and 60% in the last quarter of 2000 to 81%, 90%, 86%, 79%, 80% and 74%, respectively, 24 months after the establishment of the QA system. Within the same period, the rate of false-positives and -negatives decreased from respectively 14.8% and 20.5% to 0%, and agreements in positivity grade increased from 74% to 95%. The performance of the participating laboratories in keeping the laboratory registers up to date also improved. CONCLUSION: The QA system needs to be extended to the rest of the country.

Clinical Laboratory Techniques↗

Diagnostic utility of polymerase chain reaction and immunohistochemical techniques for the laboratory diagnosis of intracranial tuberculoma.

In an attempt to establish a tuberculous etiology, polymerase chain reaction (PCR) and immunohistochemical (IHC) methods were undertaken in formalin-fixed paraffin sections of ten surgical specimens of intracranial tuberculoma. The control group included an equal number of intracranial fungal granuloma. Both PCR and IHC methods did not yield false-positive results in fungal granuloma. PCR was found to be less sensitive (60%) than IHC method (80%) in this study. IHC method definitely possesses several operational advantages over PCR and is more suited to laboratories in developing countries for establishing a tuberculous etiology particularly in those patients in whom the conventional bacteriological methods did not confirm the diagnosis of tuberculoma.

Adolescent↗

Is serological testing a reliable tool in laboratory diagnosis of syphilis? Meta-analysis of eight external quality control surveys performed by the german infection serology proficiency testing program.

The accuracy of diagnostic tests is critical for successful control of epidemic outbreaks of syphilis. The reliability of syphilis serology in the nonspecialist laboratory has always been questioned, but actual data dealing with this issue are sparse. Here, the results of eight proficiency testing sentinel surveys for diagnostic laboratories in Germany between 2000 and 2003 were analyzed. Screening tests such as Treponema pallidum hemagglutination assay (mean accuracy, 91.4% [qualitative], 75.4% [quantitative]), Treponema pallidum particle agglutination assay (mean accuracy, 98.1% [qualitative], 82.9% [quantitative]), and enzyme-linked immunosorbent assays (ELISAs) (mean qualitative accuracy, 95%) were more reliable than Venereal Disease Research Laboratory (VDRL) testing (mean accuracy, 89.6% [qualitative], 71.1% [quantitative]), the fluorescent treponemal antibody absorption test (FTA-ABS) (mean accuracy, 88% [qualitative], 65.8% [quantitative]), and immunoblot assays (mean qualitative accuracy, 87.3%). Clearly, immunoglobulin M (IgM) tests were more difficult to manage than IgG tests. False-negative results for samples that have been unambiguously determined to be IgM and anti-lipoid antibody positive accounted for 4.7% of results in the IgM ELISA, 6.9% in the VDRL test, 18.5% in the IgM FTA-ABS, and 23.0% in the IgM immunoblot assay. For negative samples, the mean percentage of false-positive results was 4.1% in the VDRL test, 5.4% in the IgM ELISA, 0.7% in the IgM FTA-ABS, and 1.4% in the IgM immunoblot assay. On average, 18.3% of participants misclassified samples from patients with active syphilis as past infection without indicating the need for further treatment. Moreover, 10.2% of laboratories wrongly reported serological evidence for active infection in samples from patients with past syphilis or in sera from seronegative blood donors. Consequently, the continuous participation of laboratories in proficiency testing and further standardization of tests is strongly recommended to achieve better quality of syphilis serology.

Antibodies, Bacterial↗

Laboratory diagnosis of myocardial ischemia.

The evaluation of myocardial metabolic changes in ischemic heart disease remains centered on the coronary sinus pacing and sampling techniques established over the last 25 years. Lactate remains the marker of choice for most institutions, though centers with more sophisticated laboratories will always be trying to improve on the sensitivity and specificity for ischemia, perhaps using ATP catabolites and nucleotides and measuring coronary sinus flow. The diagnostic value of lactate changes is limited and probably not superior to a well-conducted 12-lead treadmill exercise electrocardiogram test, but it does provide an objective marker for reliable further study and evaluation of interventions. It is almost certainly in the research context that metabolic studies have their place--evaluating drugs, surgery, or angioplasty and perhaps shedding light on obscure entities, such as chest pain with normal coronary arteries and cardiomyopathies. Attention to detail and simplicity of study are more likely to lead to valuable results rather than concentrating on the complexities. Each laboratory should establish the reproducibility of its results before commencing any procedures.

Adrenergic beta-Antagonists↗

Non-invasive laboratory diagnosis of deep venous thrombosis.

Both legs of 52 patients, in whom deep thrombosis was clinically suspected in one leg, were investigated. Out of the 52 legs used as a control, without suspected deep venous thrombosis, two were found to have deep venous thrombosis. Laboratory findings revealed that deep venous thrombosis was not present in 25% of the cases suspected. The patients in this group did not require venogram and were not treated. Nineteen suspected legs (36.5%) were proved negative not only by the laboratory method but also by venography.

Adult↗