PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Isometric”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Sarcomere length behaviour along single frog muscle fibres at different lengths during isometric tetani.

A detailed investigation of sarcomere lengthening and shortening during fixed-end tetani has been made along frog muscle fibres stretched over a large range of sarcomere lengths. A variety of sources of error common in such measurements are quantitated and give an uncertainty in sarcomere length of about 53-62 nm. The difference in sarcomere length calculated from the left and right first orders at rest was 21 nm +/- 16 nm and this is suggested to be a measure of 'Bragg artefact'. The laser diffraction measurements showed that the shortening end regions decrease in size during contraction and that the magnitude of shortening is increased at greater fibre extensions. The average length change and sarcomere length of the central and end regions was 0.10 microns (2.85 microns) and 0.37 microns (2.66 microns), respectively. The sarcomere length of the end regions at the end of creep was regularly observed to be less than 2.1 microns. An unexpected finding was the occasional observation of striations in the transition zone between lengthening and shortening regions which remained nearly isometric during a period of tension rise during creep. Measurements of diffraction order linewidth do not suggest increased sarcomere length dispersion in these areas. A smooth transition from shortening to lengthening was always observed. Although our data are in general agreement with the models proposed by Morgan, Mochon and Julian (Biophys. J. 39 (1982) 189-96) and Edman and Reggiani (J. Physiol. (Lond.) 351 (1984) 169-98), specific differences which do exist are discussed.

Animals↗

A method for recording isometric tension development by isolated cardiac myocytes: transducer attachment with fibrin glue.

The purpose of this study was to develop a method for attachment of single isolated cardiac myocytes to a transducer for recording isometric tension development. Cardiac myocytes were isolated from the hearts of the toad, Bufo marinus or ferrets by enzymatic digestion with collagenase. The method that we used provided a 60-80% yield of Ca++-tolerant cells. A suspension of cells was placed into a superfusion chamber coated with bovine thrombin. Two glass microtools - each attached to a micromanipulator - were brought into proximity with the ends of a single myocyte; one of the microtools was attached to the element of a low-level force transducer. Human fibrinogen was loaded into a fine-tipped glass micropipette mounted on a micromanipulator. Small amounts of fibrinogen were pressure-ejected from the pipette at each junction between the microtool and the end of the myocyte. The fibrin that formed produced a stable attachment of the ends of the myocyte to the microtools. The myocyte could subsequently be stretched and a length-tension curve recorded. We have used this method to record concentration-dependent tension development in response to the Ca++-ionophore, A23187, and potassium depolarization. Our results indicate that fibrin glue may facilitate the study of the mechanical properties of isolated myocytes.

Animals↗

Muscular sound and force relationship during isometric contraction in man.

The contracting muscle generates a low frequency sound detectable at the belly surface, ranging from 11 to 40 Hz. To study the relationship between the muscular sound and the intensity of the contraction a sound myogram (SMG) was recorded by a contact sensor from the biceps brachii of seven young healthy males performing 4-s isometric contractions from 10% to 100% of the maximal voluntary contraction (MVC), in 10% steps. Simultaneously, the electromyogram (EMG) was recorded as an index of muscle activity. SMG and EMG were integrated by conventional methods (iSMG and iEMG). The relationship between iSMG and iEMG vs MVC% is described by parabolic functions up to 80% and 100% MVC respectively. Beyond 80% MVC the iSMG decreases, being about half of its maximal value at 100% MVC. Our results indicate that the motor unit recruitment and firing rate affect the iSMG and iEMG in the same way up to 80% MVC. From 80% to 100% MVC the high motor units' discharge rate and the muscular stiffness together limit the pressure waves generated by the dimensional changes of the active fibres. The muscular sound seems to reflect the intramuscular visco-elastic characteristics and the motor unit activation pattern of a contracting muscle.

Adult↗

Changes in R-R variability before and after endurance training measured by power spectral analysis and by the effect of isometric muscle contraction.

The long-term conditioning effects of physical training on cardiorespiratory interaction in 11 young healthy males were studied. Significant increases in maximum oxygen uptake (VO2max) (P < 0.05) and decreases in heart rate (P < 0.05) were achieved in all subjects following a 6-week training programme consisting of cycling for 25 min each day at a work level that increased heart rate to 85% of maximum. Heart rate variability, measured as the differences between the maximum and minimum R-R interval in a respiratory cycle, increased in nine of the subjects and decreased in two. The respiratory-cycle-related high-frequency peak in the power spectral plot of R-R variability also showed significant increases in the same nine subjects and decreases in two. The latter result was similar after normalisation of the data for changes in heart rate by calculating the common coefficient of variance [symbol: see text], where HF is the high-frequency component of the power spectral plots, using a further measure of vagal tone it was shown that, for all subjects, the R-R interval change in response to isometric contractions of the arm flexors in one respiratory cycle were significantly greater after training. These data suggest that cardiac vagal tone is increased by aerobic training for all subjects and that this is accompanied by a respiratory sinus arrhythmia (RSA) in most, but may be associated with a decrease in RSA in subjects with a very low (< 50 beats.min-1 heart rate.

Adult↗

Gradual potentiation of isometric muscle force during constant electrical stimulation.

An investigation was carried out into how stimulation frequency and stimulation history affect the potentiation of muscle force during 20s of constant stimulation of the two knee extensors in isometric conditions. Stimulation frequency significantly affected the potentiation pattern: low-frequency (2.5-10 Hz) stimulation showed a reduction and subsequent enhancement of force, and high-frequency (14.3-25 Hz) stimulation showed only enhancement of force. The degree of enhancement in force and time-to-peak decreased with the stimulation frequency. Whereas 40 Hz conditioning stimulation enhanced the muscle force, 14 Hz stimulation after 10s of rest induced little force enhancement (8% in both muscles). When the frequency of the conditioning stimulation was 14 Hz and the main 14 Hz stimulation was applied after 50s of rest, the initial force at the main stimulation was similar to the final force value of the conditioning stimulation (above 90% similarity). The potentiated twitch force slowly decayed during rest, with an average time constant of 2.4 min. These observations indicate that muscle potentiation depends on the stimulation frequency and stimulation history, and therefore a computer model of potentiation can play an important role in predicting muscle force and body movement induced by electrical stimulation.

Adult↗

Analysis of hand forces in health and disease during maximum isometric grasping of cylinders.

An analysis of force distribution in the hand during maximum isometric grasping actions is reported in a detailed and accurate manner. A microcomputer-controlled instrument which measures all 12 phalangeal forces of fingers simultaneously, in a single attempt at squeezing a cylindrical object, is described. The study involved 20 normal subjects of different weights and age groups grasping tubes of 50 mm, 75 mm, 90 mm and 110 mm diameters. Normal grasp forces decreased significantly with the increase in tube diameter, with the force being concentrated more on the distal segments of the fingers on the proximal and middle segments. The mean percentage contributions of finger forces to total grip strength, from index to little fingers, were 31, 33, 22 and 14 per cent, respectively. The study was extended to cover leprotic and paralytic hands to assess their functional capabilities. In the case of leprosy subjects, the grip strength decreased with the severity of the disease and was only about 50 per cent of that of normal subjects. In hemiplegics, the grip strength was only about one-eighth of the normal values. The above assessment procedure provides baseline data which could serve as guidelines to a clinician in assessing the severity of the disease and observing the patient's recovery following the treatment. It would also be useful in the design of hand-operated controls and prosthetic arms.

Fingers↗

Apparatus to measure simultaneously 14 isometric leg joint moments. Part 1: Design and calibration of six-axis transducers for the forces and moments at the ankle.

An apparatus has been developed for making isometric measurements of the joint moments corresponding to the 14 degrees of freedom of the legs, in postures ranging between sitting and near full extension. The apparatus is called the multi-moment chair system (MMCS) and is described in the companion paper. This paper describes the most critical components of the MMCS, which are the six-axis transducers for measuring the force and moment components on the plantar-flexion axis of each ankle while the feet are laced into fixed shoes. The transducers are made of steel bars, on which strain gauges are mounted, joined by clamps. The design of the transducer and methods of calibration and error estimation are described. The RMS errors are less than 2 N for the forces and 1 Nm for the moments, but these may be correlated. A method for error reduction that compensates for the finite compliance of the transducer does not reduce the measured errors.

Ankle Joint↗

Apparatus to measure simultaneously 14 isometric leg joint moments. Part 2: Multi-moment chair system.

An apparatus has been developed that measures isometrically the 14 lower limb joint moments corresponding to the degrees of freedom of the hips, knees and ankles. This is the second of two papers describing the development of the multi-moment chair system (MMCS). It presents the overall design and changes that were implemented to compensate for problems. These were primarily to improve the accuracy of hip joint moments; a compromise between accuracy and practicalities, because of force-moment responses being measured at the ankles. All joint moment errors have been calculated to be of the order of a few newton metres. Since these represent errors of less than 10% when considering peak joint moment responses, this is considered sufficiently accurate for the proposed application. The MMCS is being used in a programme to investigate the restoration of lower limb functions, principally standing, in paraplegics by electrical stimulation of the lumbosacral anterior roots.

Electronics, Medical↗

Discrete and continuous planning of hand movements and isometric force trajectories.

We have previously demonstrated that, in preparing themselves to aim voluntary impulses of isometric elbow force to unpredictable targets, subjects selected default values for amplitude and direction according the range of targets that they expected. Once a specific target appeared, subjects specified amplitude and direction through parallel processes. Amplitude was specified continuously from an average or central default; direction was specified stochastically from one of the target directions. Using the same timed response paradigm, we now report three experiments to examine how the time available for processing target information influences trajectory characteristics in two-degree-of-freedom forces and multijoint movements. We first sought to determine whether the specification of force direction could also take the form of a discrete stochastic process in pulses of wrist muscle force, where direction can vary continuously. With four equiprobable targets (two force amplitudes in each of two directions separated by 22 degrees or 90 degrees), amplitude was specified from a central default value for both narrow and wide target separations as a continuous variable. Direction, however, remained specified as a discrete variable for wide target separations. For narrow target separations, the directional distribution of default responses suggested the presence of both discrete and central values. We next examined point-to-point movements in a multijoint planar hand movement task with targets at two distances and two directions but at five directional separations (from 30 degrees to 150 degrees separation). We found that extent was again specified continuously from a central default. Direction was specified discretely from alternative default directions when target separation was wide and continuously from a central default when separation was narrow. The specification of both extent and direction evolved over a 200-ms time period beginning about 100 ms after target presentation. As in elbow force pulses, extent was specified progressively in both correct and wrong direction responses through a progressive improvement in the scaling of acceleration and velocity peaks to the target. On the other hand, movement time and hand path straightness did not change significantly in the course of specification. Thus, the specification of movement time and linearity, global features of the trajectories, are given priority over the specific values of extent and direction. In a third experiment, we varied the distances between unidirectional target pairs and found that movement extent is specified discretely, like direction, when the disparity in distances is large. The implications of these findings for contextual effects on trajectory planning are discussed. The independence of extent and direction specification and the prior setting of response duration and straightness provide critical support for the hypothesis that point-to-point movements are planned vectorially.

Adult↗

Matching different levels of isometric torque in elbow flexor muscles after eccentric exercise.

Human subjects generated a specified level of isometric torque with elbow flexor muscles of one arm, the reference arm, under visual feedback. They were then asked to generate what they perceived to be the same level, with the other arm, the indicator, but with no visual feedback. A number of torque levels, between 2% and 30% of maximum were used in the matching trials. Elbow flexors of one arm were then exercised eccentrically on a dynamometer. Immediately after the exercise, there was a large (40%) drop in maximum voluntary torque, as well as some soreness and swelling 24 h later, indicative of muscle damage. When the torque-matching experiment was repeated after the indicator arm had been exercised, the indicator signalled torque levels significantly below the reference level (P<0.05). When the reference arm was exercised, errors were in the opposite direction. Over the 4 days of testing post-exercise, errors became less as torque levels returned to normal. When errors were expressed in terms of maximum torque post-exercise, they were significantly reduced. This suggested that subjects were using as a matching cue the perceived effort required to generate a given level of torque rather than the level of torque itself. Persisting matching errors, from 24 h onwards after the eccentric contractions, were proposed to include a component attributable to the muscle soreness. Changes in electromyogram recorded after eccentric exercise were consistent with the effort-matching hypothesis. The muscle's torque-angle relationship was used to estimate matching ability in the absence of fatigue. One forearm was placed at various angles and its reference torque was matched by the other, the indicator, always at 90 degrees. Again, matching errors were consistent with an interpretation based on a match of effort rather than torque.

Adolescent↗

On the relations between single cell activity in the motor cortex and the direction and magnitude of three-dimensional dynamic isometric force.

The role of the motor cortex in the control of both the direction and magnitude of dynamic force, when both are allowed to vary in 3D, is not known. We recorded the activity of 504 cells in the motor cortex of two monkeys during a behavioral task in which the subjects used a manipulandum to vary both the direction and magnitude of isometric force in 3D space. The majority (86%) of cells active in the task related to the direction, a tiny number (2.5%) to the magnitude, and a moderate number (11.5%) to both the direction and magnitude of dynamic force output. Finally, we compared neural activity in the same population of neurons during dynamic and static force output and found that the relations to direction and magnitude were very similar in both epochs. Our results indicate that during dynamic force production, cells in the motor cortex are primarily concerned with specifying the direction of force. The magnitude signal is not prominent in motor cortex neurons, and in general, magnitude and direction of force are specified together. Furthermore, the data suggest that the control of static and dynamic motor systems is based, to a great extent, on a common control process.

Action Potentials↗

Periodontal anaesthesia reduces common 8 Hz input to masseters during isometric biting.

During isometric contractions of the jaw muscles, oscillations in the rectified masseteric EMG record that are coherent with the mandibular force output are evident at ~8 Hz. We have investigated the load dependence of these oscillations under both force and EMG feedback conditions and the extent to which these oscillations are coupled bilaterally in the jaw muscles. We further investigated the extent to which afferent information arising from the periodontium during biting influenced the extent of ~8 Hz EMG tremor and the bilateral coupling between masseters at this frequency. Using coherence analysis we have shown that a significant load-independent coupling of EMG between the closing muscles of the jaw occurs at ~8 Hz as a result of common ~8 Hz input to the masseters. This common input is significantly reduced when afferent information from the periodontium is blocked. These results suggest that afferent information arising from the periodontium enhances the expression of peripheral tremulous activity, which may be important for optimising the response of the jaw to changes in forces occurring between the teeth.

Adolescent↗

Information processing limitations with aging in the visual scaling of isometric force.

The experiment examined if age-related increases in force variability were due to decreases in visual acuity and/or visual-motor information processing deficits. Visual information scale was manipulated over a 250-fold range as young (20-29 years old) and old (60-79 years old) participants produced isometric force output to a visually presented target. Older adults were found to have a very small decrement in visual acuity, but there was no relation between visual acuity and force variability. Force variability exhibited a U-shaped trend as a function of visual information scale. Young adults had less relative variability and higher visual information transfer than the oldest old and these age differences increased with visual information scale. It is concluded that the age-related declines in visual-motor information processing influence changes in neuromuscular function and the emergent differences in force variability at the behavioral level.

Adult↗

Movement-related parameters modulate cortical activity during imaginary isometric plantar-flexions.

A multitude of studies have demonstrated a clear activation of the motor cortex during imagination of various motor tasks; however, it is still unclear if movement-related parameters (movement direction, range of motion, speed, force level and rate of force development) specifically modulate cortical activation as they do during the execution of actual motor tasks. Accordingly, this study examined whether the rate of torque development (RTD) and/or the torque amplitude modulates cortical potentials generated during imaginary motor tasks. Fifteen subjects imagined four different left-sided isometric plantar-flexion tasks, while EEG and EMG recordings were being performed. The averaged EEG activity was analyzed in terms of movement-related potentials (MRPs), consisting of readiness potential (RP), motor potential (MP) and movement-monitoring potential (MMP). It was demonstrated that RTD and torque amplitude indeed modulate cortical activity during imaginary motor tasks. Information concerning movement-related parameters for imaginary plantar-flexion tasks seems to be encoded in the supplementary motor area (SMA) and the primary motor cortex (M1). A comparison between MRPs of imaginary and actual motor tasks revealed that early MRPs were morphologically similar, but differed significantly in amplitude. One of the possible suggestions to explain such a difference may be an "abortion" of ongoing motor programs.

Adolescent↗

Limits of the dual-strategy hypothesis in an isometric plantar flexion contraction.

Movements have been described as being governed by a speed-sensitive (SS) or speed-insensitive (SI) strategy. The SS strategy is used when the subject controls, either explicitly or implicitly, movement speed or time. In contrast, the SI strategy is utilized when there is no intention or requirement to control movement speed. The different strategies demonstrate a specific relationship between torque trajectories and muscle activity. The purpose of this study was to determine the effect of accuracy and force level on strategy selection. Ten healthy adults were instructed to generate isometric pulse contractions of the right soleus at 20%, 40%, and 60% of maximum voluntary contraction (MVC) to reach five target sizes of percentage MVC (4%, 8%, 12%, 16%, 20%). The following results were observed: (1) there was no difference in time to peak force, peak dF/dt, slope of force, and electromyographic (EMG) measures between the 12%, 16%, and 20% target sizes; (2) differences were noted, however, between the 12%, 16%, and 20% targets and the smaller targets; (3) for the dependent measures there were significant differences between each force level. No difference between the larger targets implies that subjects do not need to implement a strategy and suggests an upper limit to the dual-strategy hypothesis. The difference between the smaller and larger targets and the difference between the force levels is indicative of an SS strategy. When asked to use different force levels, subjects controlled the rate of rise of force and regulated time to peak force. Between target sizes, force and time were modulated equally.

Adult↗

Isometric force kinetics upon rapid activation and relaxation of mouse, guinea pig and human heart muscle studied on the subcellular myofibrillar level.

The kinetics of force development and relaxation upon rapid application and removal of Ca2+ was measured in bundles of few myofibrils isolated from triton X-100 skinned left ventricular trabeculae of mice (M), guinea pigs (G) and humans (H). Upon rapidly switching from relaxing solution (pCa 7.5) to activating solution (pCa 4.5) at 10 degrees C, force rose by a single exponential with a rate constant k(act) of 5.2 s(-1) (M), 1.7 s(-1) (G) and 0.3 s(-1) (H) to a plateau of 0.14 microN/microm2 (M), 0.16 microN/microm2 (G) and 0.15 microN/microm2 (H). A rapid release followed by a rapid restretch to the original length applied during steady-state Ca2+ activation at pCa 4.5 induced an exponential force redevelopment with a rate constant k(redev) that was indistinguishable from k(act), indicating that k(act) is limited by cross-bridge turnover kinetics rather than by the Ca2+-induced activation of the regulatory system. Upon rapidly switching from pCa 4.5 to pCa 7.5, force decayed in a pronounced biphasic manner. Thus a slow initial, almost linear decay with a rate constant k(lin) of 1.8 s(-1) (M), 0.6 s(-1) (G) and 0.15 s(-1) (H) and a duration t(lin) of 0.06 s (M), 0.11 s (G) and 0.3 s (H) was followed by a rapid exponential decay with a rate constant k(rel) of 18 s(-1) (M), 11 s(-1) (G) and 4.6 s(-1) (H). The pronounced biphasic shapes of the force decays determined here for the first time in cardiac myofibrils differs from the force decays that had been reported for multicellular skinned trabeculae in which relaxation was induced by rapid removal of Ca2+ by flash photolysis of caged Ca2+ chelators. In the skinned trabeculae, no pronounced initial slow phase was observed. The force decays shown here are much more similar to those reported for single skeletal myofibrils. The kinetics of isometric relaxation of skinned trabeculae (i.e., multicellular preparations), therefore, do not reflect the kinetics of force relaxation at the cardiac myofibrillar level.

Animals↗

Early recovery of isometric shoulder muscle strength after open acromioplasty in stage II impingement syndrome.

The recovery of shoulder muscle strength after open acromioplasty was evaluated in 48 patients (27 male, 21 female, mean age 44.3 years) who had undergone open acromioplasty because of stage II impingement syndrome. The isometric strengths of flexion, abduction and external rotation were measured before the operation and at 3, 6 and 12 months postoperatively. The mean preoperative flexion strength of the involved shoulder was 72.6% of that of the uninvolved shoulder, and this increased to 77.1% by 3 months post operation, to 88.3% at 6 and to 88.3% at 12 months. Corresponding abduction strengths were 68.4%, 80.4%, 88.7% and 91.0% and the external rotation strengths were 75.1%, 77.4%, 95.1% and 93.5%, respectively. These recoveries were markedly improved when the cases with poor subjective results at 1 year were not considered. The low preoperative strengths were more pronounced in women than in men, but recovery was better in women. It is concluded that shoulder muscle strengths recover to near normal in 1 year after open acromioplasty.

Acromion↗

Differences in strength and surface electromyogram characteristics between pre-pubertal gymnasts and untrained boys during brief and maintained maximal isometric voluntary contractions.

The present study was aimed at investigating differences of maximal strength (F(max)) of the elbow flexors and characteristics of the surface electromyogram (EMG) between six gymnasts (G) and six untrained (UT) 10-year-old boys during brief and maintained maximal voluntary isometric contraction (MVC). The F(max) was estimated during 5 s MVC (maximal test, MT) and normalized to the cross sectional area (CSA) of the arm. The EMG signal of the biceps brachii was recorded during MT and during a 25 s maintained MVC (fatigue test). Values were calculated for root-mean-square (rms(MT)) and mean power frequency (MPF(MT)) of the EMG signal for the duration of the MT. For the fatigue test, MPF were normalized to the initial value (MPF(n)) and kinetics were expressed by the slope coefficient of linear regression. Although F(max) and F(max)/CSA tended to be higher for G than UT, the differences did not reach significance. The MPF(MT) was significantly higher for G [mean (SD)][136 (8) Hz] than for UT [125 (9) Hz]. The MPF(n) slope coefficients were significantly greater for G than for UT [-1.0 (0.2) and -0.5 (0.3), respectively]. When all the children were considered, F(max) was significantly correlated to MPF(MT) (r = 0.61). These results showed that gymnasts tend to have higher F(max) and F(max)/CSA accompanied by a significantly higher MPF(MT) and a steeper MPF downshift. Moreover, children with greater strength tended to have higher MPF(MT). It is suggested that spatial and/or temporal recruitment of more fatigable fast motor units could have been enhanced in G and more generally, that it could be a mechanism that would explains, in part, the level of force production in children.

Child↗