PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83Linked to original sources

Genetic Models in Applied Physiology. Merosin deficiency leads to alterations in passive and active skeletal muscle mechanics.

The role of extracellular elements on the mechanical properties of skeletal muscles is unknown. Merosin is an essential extracellular matrix protein that forms a mechanical junction between the sarcolemma and collagen. Therefore, it is possible that merosin plays a role in force transmission between muscle fibers and collagen. We hypothesized that deficiency in merosin may alter passive muscle stiffness, viscoelastic properties, and contractile muscle force in skeletal muscles. We used the dy/dy mouse, a merosin-deficient mouse model, to examine changes in passive and active muscle mechanics. After mice were anesthetized and the diaphragm or the biceps femoris hindlimb muscle was excised, passive length-tension relationships, stress-relaxation curves, or isometric contractile properties were determined with an in vitro biaxial mechanical testing apparatus. Compared with controls, extensibility was smaller in the muscle fiber direction and the transverse fiber direction of the mutant mice. The relaxed elastic modulus was smaller in merosin-deficient diaphragms compared with controls. Interestingly, maximal muscle tetanic stress was depressed in muscles from the mutant mice during uniaxial loading but not during biaxial loading. However, presence of transverse passive stretch increases maximal contractile stress in both the mutant and normal mice. Our data suggest that merosin contributes to muscle passive stiffness, viscoelasticity, and contractility and that the mechanism by which force is transmitted between adjacent myofibers via merosin possibly in shear.

Animals↗

Viscoelastic properties of red cell membrane in hereditary elliptocytosis.

The viscoelastic properties of the RBC membrane are in part determined by a submembrane network of proteins consisting of spectrin alpha beta heterodimers (SpD) assembled head-to-head to form spectrin tetramers (SpT) and spectrin oligomers (SpO). SpT, in turn, are connected into a two-dimensional network by the linkage of distal ends of SpT to protein 4.1 and actin. With the micropipette technique, we determined the membrane viscoelastic properties of RBCs from a subset of patients with hereditary elliptocytosis (HE); these RBCs exhibit membrane skeletal instability, defective SpD self-association, and a molecular defect in the alpha I domain of spectrin, which is involved in the SpD-SpD contact (HE SpD alpha-SpD). The elastic modulus and viscosity of the membrane were significantly higher for the HE RBCs than for the control cells. Incubation of normal cells with N-ethyl-maleimide (NEM) produced a similar defective SpD self-association and a significant increase in the viscoelastic parameters of the membrane. The data provide evidence that the mode of assembly of membrane spectrin in the cytoskeletal protein network plays a major role in determining the rheologic behavior of erythrocyte membrane.

Elasticity↗

Photopolymerization of developmental monomers for dental cationically initiated matrix resins.

OBJECTIVES: The objectives were to investigate the structure and selected physical properties of products resulting from the photopolymerization of a binary mixture containing an aliphatic dioxirane, 3,4-epoxycyclohexylmethyl-3,4-epoxycyclohexane carboxylate (ECHM-ECHC) and a potential expanding monomer, 3,9-bis(oxiranylcyclohexylmethyl)-1,5,7,11-tetraoxaspiro[5.5]undecane (BOCHM-TOSU). METHODS: Reaction mixtures were irradiated with a dental curing lamp at room temperature. Some reactions were quenched prior to gel point. Oligomeric products were separated from unreacted monomers by column chromatography, and analyzed by NMR. Physical properties of polymeric solids were measured using accepted standard methods. Protonation energies for monomers were calculated using semi-empirical quantum mechanical methods. RESULTS: Types of oligomers found included poly(ether)s and poly(carbonate)s. Quantum mechanical calculations indicated preferential attack at the more nucleophilic oxaspirocyclic ring sites. For cured solid polymer samples, the elastic modulus was 2.39 +/- 0.24 GPa and the fracture toughness was 0.73 +/- 0.10 MPa m(1/2). These values were similar to those measured for a cured conventional BISGMA/TEGDMA matrix resin. SIGNIFICANCE: The room-temperature photopolymerization of an aliphatic dioxirane and a potential expanding monomer demonstrates the possibility of making cross-linked copolymer resins with improved polymerization shrinkage characteristics for use in dental composites.

Alkanes↗

Nanoindentation and storage of teeth.

This study determined changes in nanomechanical properties of dentin and enamel during storage in deionized water, calcium chloride buffered saline solution and Hank's balanced salts solution (HBSS). Atomic force microscopy based nanoindentation showed that storing teeth in deionized water or CaCl(2)-solution resulted in a large decrease in elastic modulus and hardness. At 1 day a decrease in the mechanical properties values of up to 20% and 30% was observed for enamel and dentin, respectively. After 1 week, mechanical properties dropped below 50% of their starting values, which is attributed to a demineralization process during storage. In contrast, storing teeth in HBSS did not significantly alter the mechanical properties for a time interval of 2 weeks. The use of HBSS for storage of samples from teeth is recommended.

Biomechanical Phenomena↗

Dromedary milk lactic acid fermentation: microbiological and rheological characteristics.

The ability of dromedary skim milk to form an acid curd during a lactic acid starter fermentation was investigated. The activity of the starter in dromedary milk was characterized by a longer lag phase ( approximately 5 vs. approximately 1 h) and by an earlier decline phase. This suggests the presence of inhibiting factors. The maximum buffering capacity of dromedary milk as well as its minimum apparent viscosity were obtained at lower pH values. Similarly, its elastic modulus appeared later (pH 5.7 vs. 6.3). Because these rheological and biochemical events took place at lower pH values, dromedary skim milk seems to present a higher physical stability toward the increase of acidity. Determination of the rheological and microscopic characteristics of the dromedary milk coagulum (pH 4.4) did not reveal curd formation but indicated a fragile and heterogeneous structure. This coagulum, which is very different from that of cows' milk, seems to be made up of dispersed casein flakes.

Animals↗

Nanomechanical properties and mineral concentration in articular calcified cartilage and subchondral bone.

We studied articular calcified cartilage (ACC) and the immediately subchondral bone (SCB) in normal and osteoarthritic human femoral heads. Thick slices of human normal reference post mortem (PM) and osteoarthritic (OA) femoral heads (age 55-89 years) were embedded in PMMA, micromilled, carbon coated and studied using quantitative backscattered electron (qBSE) imaging to determine variations in degree of mineralization. With exact microanatomical location, nanoindentation was performed on the same block faces in representative superior (more highly loaded) and medial regions of the joint surface. Using a partial unloading method, elastic modulus as a function of indenter penetration depth was determined using a spherical tipped diamond indenter. A pointed indenter was used to determine the tissue hardness in selected locations. The relationship between mineralization and indentation modulus was more distinct in ACC than in SCB, the latter having a higher matrix concentration with variable collagen orientation. In OA, the bulk of the measurements were coincident with those in the PM samples, although there was a greater range in the levels of mineralization and modulus in ACC. In OA, extremely hypermineralized ACC was found in ACC proper, especially in superior regions, and translocated into SCB and hyaline cartilage. The very highly mineralized cartilage fragments may function as a hard grinding abrasive, accelerating wear rates whether attached to or fragmented from the eburnated surfaces of OA ACC. Highly mineralized regions would also alter loading patterns and thereby contribute to further destruction of the joint tissues.

Aged↗

Cytoskeletal polymer networks: the molecular structure of cross-linkers determines macroscopic properties.

In living cells the mechanical properties of the actin cytoskeleton are defined by the local activation of different actin cross-linking proteins. These proteins consist of actin-binding domains that are separated and geometrically organized by different numbers of rod domains. The detailed molecular structure of the cross-linking molecules determines the structural and mechanical properties of actin networks in vivo. In this study, we systematically investigate the impact of the length of the spacing unit between two actin-binding domains on in vitro actin networks. Such synthetic cross-linkers reveal that the shorter the constructs are, the greater the elastic modulus changes in the linear response regime. Because the same binding domains are used in all constructs, only the differences in the number of rod domains determine their mechanical effectiveness. Structural rearrangements of the networks show that bundling propensity is highest for the shortest construct. The nonlinear mechanical response is affected by the molecular structure of the cross-linker molecules, and the observed critical strains and fracture stress increase proportional to the length of the spacing unit.

Actins↗

The effects of topical estriol and vehicle cream on the mechanical and histological properties of normal rat skin.

BACKGROUND: The biomechanical and histological effects of topical estriol in normal rat skin are not clearly defined, although several favourable effects of estrogens have been suggested, especially in the postmenopausal period. Our goal was to determine whether estrogens have any such effects on skin histology and biomechanical properties in an experimental rat model. MATERIAL/METHODS: Estriol cream or vehicle cream was topically applied to the dorsum of Sprague Dawley rats of both genders in three separate groups for two weeks, and the results of the estriol and vehicle groups, as well as the non-treated control groups, were compared in terms of mechanical tensometric test results and histopathological evaluation. RESULTS: After the application of topical estriol, histologically, subcutis thinned (p<0.01), the thickness of collagen fibrils increased (p<0.01), and elastic fibrils and dermal connective tissue cells appeared denser in female estriol group rats; mechanically, the elasticity modulus increased in the estriol groups of both sexes (p<0.05), whereas breaking strength, tensile strength and strain decreased in female estriol group rats (p<0.05). CONCLUSIONS: Estrogens can change the mechanical and histological features of normal skin, and these changes are observed differently in female and male rats. Further studies to investigate the collagen structure and its interaction with ground substance, as well as effects of estriol on rat skin without a vehicle cream, are necessary to better understand the effects of estriol on skin mechanics.

Animals↗

Are corneocytes elastic?

By using a microhandling system, we have recorded the force necessary to elongate isolated corneocytes. According to certain hypothesis, it appears that the elastic modulus of corneocyte is far higher than that of stratum corneum itself. Aggregates of corneocytes are disassembled by forces with a wide range of intensity. In the light of these experiments, stratum corneum appears as a very supple material where the deformations occur more by a plastification of the intercellular medium and an unfolding of the microrelief lines than an elongation of the corneocytes themselves. Moreover, desmosomes remnants could play a certain role in the corneocytes cohesiveness.

Cell Adhesion↗

Biomechanical properties of the human umbilical cord.

The umbilical cord is a complex and fascinating structure that connects the fetus to the placenta and encases the umbilical vessels. The response of its tissues to mechanical loading due to fetal movements and uterine contractions is not well understood. The aim of this study is the evaluation of the mechanical properties of the main components of the human umbilical cord. Fresh umbilical cord specimens were collected from neonates born at term of the gestation and submitted to compliance tests. Furthermore, uniaxial tensile and stress-relaxation tests were performed on samples of umbilical vein and Wharton's jelly. Both materials exhibited nonlinear stress-strain response with increasing strain, increasing the elastic modulus (E(high) about 10-20 times E(low)) and significant viscoelastic behavior. In addition, anisotropy of the vein was observed. Although the circumferential properties of the vein (mean E(high) about 2.4 MPa) were similar to those after birth, the longitudinal stiffness of both materials was higher (mean E(high) over 10 MPa) and comparable to that of the ligaments. These findings suggest a mechanism of protection acting against excessive elongations of the cord, which could cause undue restriction of the umbilical vessel area and interference with the fetal blood circulation.

Compliance↗

Mechanics of interstitial-lymphatic fluid transport: theoretical foundation and experimental validation.

Interstitial fluid movement is intrinsically linked to lymphatic drainage. However, their relationship is poorly understood, and associated pathologies are mostly untreatable. In this work we test the hypothesis that bulk tissue fluid movement can be evaluated in situ and described by a linear biphasic theory which integrates the regulatory function of the lymphatics with the mechanical stresses of the tissue. To accomplish this, we develop a novel experimental and theoretical model using the skin of the mouse tail. We then use the model to demonstrate how interstitial-lymphatic fluid movement depends on a balance between the elasticity, hydraulic conductivity, and lymphatic conductance as well as to demonstrate how chronic swelling (edema) alters the equipoise between tissue fluid balance parameters. Specifically, tissue fluid equilibrium is perturbed with a continuous interstitial infusion of saline into the tip of the tail. The resulting gradients in tissue stress are measured in terms of interstitial fluid pressure using a servo-null system. These measurements are then fit to the theory to provide in vivo estimates of the tissue hydraulic conductivity, elastic modulus, and overall resistance to lymphatic drainage. Additional experiments are performed on edematous tails to show that although chronic swelling causes an increase in the hydraulic conductivity, its greatly increased distensibility (due to matrix remodeling) dampens the driving forces for fluid movement and leads to fluid stagnation. This model is useful for examining potential treatments for edema and lymphatic disorders as well as substances which may alter tissue fluid balance and/or lymphatic drainage.

Animals↗

Transient and residual stress in a porcelain-metal strip.

Porcelain-fused-to-metal (PFM) restorations may develop cracks during processing or in-mouth service if the relative physico-mechanical properties of the porcelain and metal are highly mismatched. Precise conditions when this might occur are not known. Many processing and property variations can affect the stresses developed throughout a porcelain-metal system. To understand this, we conducted a computer simulation of stress developed in a PFM beam. The simulation considers cooling from temperatures higher than the porcelain sagpoint. The following temperature-dependent factors were incorporated: the elastic modulus, shear viscosity (porcelain), and coefficients of thermal expansion. The cooling rate dependencies of the glass transition temperature, (Tg), and the temperature distribution during cooling were also included. The results suggest that transient tensile stress at the porcelain alloy interface may result in cracks in the porcelain during cooling. Occlusal forces may set up stresses to cause cracking at the surface of the porcelain if the compressive residual stress is not high enough. PFM restorations with an alloy of high thermal expansion coefficient require rapid cooling; on the contrary, PFM restorations with the alloys of lower coefficients require slow cooling. A high cooling rate can make up for thermal expansion mismatches between the alloy and the porcelain up to 2 x 10(-6)/degrees C. Finally, the results indicated that curvature was not a sensitive indication of stress for a multimaterial beam when visco-elastic relaxation and high cooling rates are involved. For the case modeled here, curvature varied inversely with a 1/2 to 1/7th power of the stress.

Computer Simulation↗

Strain-rate dependent material properties of the porcine and human kidney capsule.

This study was performed to characterize the mechanical properties of the kidney capsular membrane at strain-rates associated with blunt abdominal trauma. Uniaxial quasi-static and dynamic tensile experiments were performed on fresh, unfrozen porcine and human renal capsules at deformation rates ranging from 0.0001 to 7 m/s (strain-rates of 0.005-250 s(-1)). Single stroke, dynamic tests were performed on samples of porcine renal capsule at strain-rates of 0.005 s(-1) (n = 33), 0.05 s(-1) (n = 17), 0.5 s(-1) (n = 38), 2 s(-1) (n = 10), 4 s(-1) (n = 10), 50 s(-1) (n = 21), 100 s(-1) (n = 18), 150 s(-1) (n = 17), 200 s(-1) (n = 10), and 250 s(-1) (n = 17). Due to limited availability of human tissues, only quasi-static tests were performed (0.005 s(-1), n = 25). Porcine renal capsule properties were found to match the material properties of human capsular tissue sufficiently well such that porcine tissue material can be used as a human test surrogate. The apparent elastic modulus and breaking stress of the porcine renal capsule were observed to increase significantly with increasing strain-rate (p < 0.01). Breaking strain was inversely related to strain-rate (p < 0.01). The effect of increasing strain-rate on material properties diminished appreciably at rates exceeding 150 s(-1). Empirically derived mathematical models of constitutive behavior were developed using a hyperelastic/viscoelastic Ogden formulation, as well as a Cowper-Symonds law material curve multiplication.

Animals↗

Viscoelasticity of packed erythrocyte suspensions subjected to low amplitude oscillatory deformation.

Concentrated adult erythrocyte suspensions were subjected to low amplitude oscillatory shear in a Weissenberg rheogoniometer equipped with a cone-and-plate assembly. The dynamic viscoelastic properties of the suspension were measured over a broad range of frequency by a numerical solution that accounted for fluid inertia. Variation of shear amplitude and cell volume percent, and comparison of buffered saline, plasma, and dextran as suspending media showed that the cellular elements had undergone small bending and shearing deformations. Studies of normal adult erythrocytes, hypotonically swollen cells, temperature-altered cells, and erythrocyte ghosts suggested that the method was evaluating membrane material properties. The normal membrane was found to exhibit a shear rate dependent elastic modulus that increased by more than a factor of 20 over a frequency range from 0.0076 Hz to 60 Hz. The membrane viscosity showed a substantial drop with frequency indicative of a frequency thinning phenomenon. At high frequency of deformation the viscous response of normal erythrocytes was no longer indicative of a membrane property due to the dominant influence of the internal hemoglobin solution. The studies generally supported the ability of the method to quantify relative membrane material properties and detect changes in membrane structure.

Adult↗

Continuous-fiber preform reinforcement of dental resin composite restorations.

OBJECTIVES: Direct-filling resin composites are used in relatively small restorations and are not recommended for large restorations with severe occlusal-stresses. The aim of this study was to reinforce composites with fiber preforms, and to investigate the effects of layer thickness and configurations on composite properties. It was hypothesized that fiber preforms would significantly increase the composite's flexural strength, work-of-fracture (toughness) and elastic modulus. METHODS: Glass fibers were silanized, impregnated with a resin, cured, and cut to form inserts for tooth cavity restorations. Also fabricated were three groups of specimens of 2mm x 2mm x 25 mm: a fiber preform rod in the center of a hybrid composite; a thin fiber layer on the tensile side of the specimens; and a thin fiber layer sandwiched in between layers of a hybrid composite. These specimens were tested in three-point flexure to measure strength, work-of-fracture and modulus. Optical and scanning electron microscopy were used to examine the restorations and the fiber distributions. RESULTS: Microscopic examinations of insert-filled tooth cavities showed that the fibers were relatively uniform in distribution within the preform, and the inserts were well bonded with the surrounding hybrid composite. Specimens consisting of a fiber preform rod in the center of a hybrid composite had a flexural strength (mean (SD); n=6) of 313 (19)MPa, significantly higher than 120 (16)MPa of the hybrid composite without fibers (Tukey's at family confidence of 0.95). The work-of-fracture was increased by nearly seven times, and the modulus was doubled, due to fiber preform reinforcement. Similar improvements were obtained for the other two groups of specimens. SIGNIFICANCE: Substantial improvements in flexural strength, toughness and stiffness were achieved for dental resin composites reinforced with fiber preforms. The method of embedding a fiber preform insert imparts superior reinforcement to restorations and should improve the performance of direct-filling resin composites in large restorations with high occlusal-loads.

Composite Resins↗

Multiaxial mechanical characteristics of carotid plaque: analysis by multiarray echotracking system.

BACKGROUND AND PURPOSE: Carotid plaque rupture depends on the various types of mechanical stresses. Our objective was to determine the multiaxial mechanical characteristics of atherosclerotic plaque and adjacent segment of the common carotid artery. METHODS: A novel noninvasive echotracking system was used to measure intima-media thickness, diameter, pulsatile strain, and distensibility at 128 sites on a 4-cm long common carotid artery segment. The study included 62 patients with recent cerebrovascular ischemic event and either a plaque on the far wall of common carotid artery (n=25) or no plaque (n=37). RESULTS: The mechanical characteristics of the carotid segment devoid of plaque did not differ between the two groups. Among patients with plaque, 16 had a larger radial strain at the level of plaque than at the level of adjacent common carotid artery (pattern A: outward-bending strain). The eight patients who had an opposite pattern (inward-bending strain) were more often dyslipidemic (100% versus 56% P=0.03) and type 2 diabetic (63% versus 12%, P=0.04) than pattern A patients. Strain gradient significantly decreased in parallel with the presence of dyslipidemia and/or type 2 diabetes. Longitudinal gradients of distensibility and Young's elastic modulus were consistent with strain gradients. CONCLUSIONS: Type 2 diabetes and dyslipidemia were associated with a stiffer carotid at the level of the plaque than in the adjacent common carotid artery leading to an inward-bending stress. The analysis of plaque mechanics along the longitudinal axis may afford useful information, because repetitive bending strain of an atherosclerotic plaque may fatigue the wall material and result in plaque rupture.

Aged↗

A study of the relationship between mass and physical strength of keratin bars in vivo.

A study was undertaken of the changes in the mass and physical properties of keratin bars implanted subcutaneously in adult rats. A very gradual decrease occurred in vivo in the dry weight of the bars over the period of the study (up to 18 weeks). The elastic modulus of the bars decreased abruptly when present in vivo between 3 and 6 weeks. At the same time there was an increase in the number of cavitations and fissures at the surface of the bars, and an increase in a central internal region of the bars where there was a disorganisation in structure of the polymer. A biocompatible material showing such changes in vivo is likely to be suitable for a variety of medical and surgical applications in which it provides a framework for cell invasion.

Absorbable Implants↗

Mechanisms of uniformity of yield strains for trabecular bone.

Variations in yield strains for trabecular bone within a specific anatomic site are only a small fraction of the substantial variations that exist for elastic modulus and strength, and yet the source of this uniformity is not known. Our goal was to investigate the underlying mechanisms by using high-resolution, materially nonlinear finite element models of 12 human femoral neck trabecular bone specimens. The finite element models, used to obtain apparent yield strains in both tension and compression, assumed that the tissue-level yield strains were the same across all specimens. Comparison of the model predictions with the experimental data therefore enabled us to isolate the combined roles of volume fraction and architecture from the role of tissue material properties. Results indicated that, for both tensile and compressive loading, natural variations in volume fraction and architecture produced a negligible coefficient of variation (less than 3%) in apparent yield strains. Analysis of tissue-level strains showed that while bending of individual trabeculae played only a minor role in the apparent elastic behavior, the combined effects of this bending and tissue-level strength asymmetry produced apparent-level failure strains in compression that were 14% lower than those at the tissue level. By contrast, tissue and apparent-level yield strains were equivalent for tensile loading. We conclude that the uniformity of apparent yield strains is primarily the result of the highly oriented architecture that minimizes bending. Most of the variation that does occur is the result of the non-uniformity of the tissue-level yield strains.

Aged↗