Urinary benzene as a biomarker of exposure among occupationally exposed and unexposed subjects.

Urinary benzene (UB) was investigated as a biomarker of exposure among benzene-exposed workers and unexposed subjects in Shanghai, China. Measurements were performed via headspace solid phase microextraction of 0.5 ml of urine specimens followed by gas chromatography-mass spectrometry. This assay is simple and more sensitive than other methods (detection limit 0.016 microg benzene/l urine). The median daily benzene exposure was 31 p.p.m. (range 1.65-329 p.p.m.). When subjects were divided into controls (n = 41), those exposed to < or =31 p.p.m. benzene (n = 22) and >31 p.p.m. benzene (n = 20), the median UB levels were 0.069, 4.95 and 46.1 microg/l, respectively (Spearman r = 0.879, P < 0.0001). A linear relationship was observed between the logarithm of UB and the logarithm of benzene exposure in exposed subjects according to the following equation: ln(UB, microg/l) = 0.196 + 0.709 ln (exposure, p.p.m.) (r = 0.717, P < 0.0001). Considering all subjects, linear relationships were also observed between the logarithm of UB and the corresponding logarithms of four urinary metabolites of benzene, namely t,t-muconic acid (r = 0.938, P < 0.0001), phenol (r = 0.826, P < 0.0001), catechol (r = 0.812, P < 0.0001) and hydroquinone (r = 0.898, P: < 0.0001). Ratios of individual metabolite levels to total metabolites versus UB provide evidence of competitive inhibition of CYP450 enzymes leading to increased production of phenol and catechol at the expense of hydroquinone and muconic acid. Among control subjects UB was readily detected with a mean level of 0.145 microg/l (range 0.027-2.06 microg/l), compared with 5.63 microg/l (range 0.837-26.38 microg/l) in workers exposed to benzene below 10 p.p.m. (P < 0.0001). This suggests that UB is a good biomarker for exposure to low levels of benzene.

Benzene↗

Source and cyclic release pattern of (Z)-7-dodecenyl acetate, the pre-ovulatory pheromone of the female Asian elephant.

Female Asian elephants (Elephas maximus) release a pre-ovulatory urinary pheromone, (Z)-7-dodecenyl acetate (Z7--12:Ac), to signal males of their readiness to mate. Z7--12:Ac is quantitatively elevated during the follicular stage of estrus, reaching maximum concentrations just prior to ovulation, as demonstrated by two complementary headspace techniques: (i) evacuated canister capture followed by cryogenic trapping; (ii) solid phase microextraction (SPME), used prior to gas chromatography/ mass spectrometry (GC/MS). These patterns were coincident with observed male behaviors and were consistent with biochemical and binding properties of the active ligand, including optimal binding pH. To release maximum amounts of Z7--12:Ac for quantitation, serum and urine samples from three mature female Asian elephants in their luteal and follicular stages of several estrous cycles were subjected to heat and pH changes and were then treated with protease prior to SPME-GC/MS analyses. When the post-luteal serum progesterone concentrations declined to baseline levels, Z7--12:Ac became detectable in the female urine. Throughout the follicular stage pheromone concentrations increased linearly with no apparent relationship to the two serum luteinizing hormone peaks. Pre-ovulatory urine also contained related compounds, including (Z)-7--12-dodecenol. The relative amount of this alcohol increased relative to acetate during long-term storage, with a proportional reduction in bioactivity. Z7--12:Ac was not detected in mucus samples from the urogenital tract. A potential precursor of Z7--12:Ac was identified in liver homogenates from female elephants in the follicular stage.

Acetates↗

Semiquantitative determination of short-chain fatty acids in cane and beet sugars.

Some sugars, specifically white beet sugar and raw cane sugars, possess off-flavors and off-odors. Although not necessarily the source, the presence of short-chain fatty acids serves as an indicator of an off-odor problem in sugar. Solid-phase microextraction (SPME) is used to collect the volatile compounds from the headspace of sugar. The temperature, moisture, and type of SPME fiber are varied to optimize recovery. Sugars analyzed in the absence of water using an incubation temperature of 70 degrees C with a divinylbenzene-carboxen-polydimethylsiloxane fiber yield the most reproducible results. Data from depletion analyses report a recovery level of 38% for the first injection. The semiquantitative analysis of butyric acid is accomplished using injected standards to develop a calibration curve.

Calibration↗

Determination of lamotrigine simultaneously with carbamazepine, carbamazepine epoxide, phenytoin, phenobarbital, and primidone in human plasma by SPME-GC-TSD.

A simple and rapid analytical method is presented for the determination of lamotrigine simultaneously with primidone, carbamazepine, carbamazepine epoxide, phenobarbital, and phenytoin in human plasma using solid-phase microextraction (SPME) and gas chromatography with thermionic specific detection. The best conditions for the SPME procedure is established as following: direct extraction on a 65-microm Carbowax-divinylbenzene fiber; 1.0 mL of a sample plasma matrix modified with 15% NaCl and 3 mL of a potassium phosphate buffer (pH 7.0); extraction temperature at 30 degrees C; and stirring at a rate of 2500 rpm for 15 min. The method shows good linearity between 0.05 and 40.0 microg/mL with regression coefficients ranging between 0.9965 and 0.9995 and a coefficient of variation of the points of the calibration curve lower than 10%. The lowest limit of quantitation for the plasma-investigated drugs varies from 0.05 to 0.20 microg/mL, according to the drug. The proposed method is sensitive enough to work into subtherapeutic and therapeutic concentrations, being that it is applied in pharmacokinetic studies and patient routine therapeutic drug monitoring.

Anticonvulsants↗

Fast temperature-programmed gas chromatography-mass spectrometry for food analysis.

Fast temperature-programmed gas chromatography (FTGC) is evaluated. A modified capillary column allowing temperature-program rates as high as 20 degrees C/s is operated with mass spectrometric detection (MSD). FTGC methods are developed for the analysis of off-flavors in water, derivatized sugars, and fatty acid methyl esters. Liquid injection and solid-phase microextraction are evaluated. Although the resolution can be somewhat lower than analysis with a traditional column, time savings are significant. Analysis times range from 2 to 4.5 min compared with 20 to 60 min for conventional methods. MSD allows for the analysis of some coeluting peaks, which allows for quantitation even when peaks coelute.

Food Analysis↗

Determination of limonene oxidation products using SPME and GC-MS.

Limonene is a common component found in consumer goods ranging from beverages to cleaning compounds. Limonene oxidation products, however, have a less desirable flavor and fragrance. Early detection of limonene oxide formation would aid quality control. A method is developed to determine the concentration of limonene oxide in essential oils and beverages using solid-phase microextraction (SPME). A headspace sampling technique is used to reduce or eliminate the presence of less volatile components. Several different SPME fibers are tested, varying in polymer thickness, polymer cross-linking and bonding, and polarity of the polymer. For each fiber tested, the sampling time is optimized for reproducible results. The 7-microm-thick bonded poly(dimethylsiloxane) fiber provides the best results. External standards are used for quantitation.

Chromatography, Liquid↗

Field sampling with a polydimethylsiloxane thin-film.

In this research, field samplers are developed using polydimethylsiloxane (PDMS) thin-film as the extraction phase. This technique is based on a similar theory, the solid-phase microextraction (SPME) technique. More specifically, the development of the field sampler involves cutting a section of PDMS thin-film into a specific size and shape, and mounting it onto a stainless steel wire (the handle). The thin-film is then placed into a protective copper cage prior to deployment to prevent biofouling. Kinetic calibration or equilibrium calibration with the standards in the extraction phase is used to introduce an isotopically labeled internal standard for on-site calibration. The initial loading of the standard onto the thin-film and the amount of standard remaining on the thin-film are determined using gas chromatography-mass spectrometry and subsequently used to estimate the concentration of the target analytes. In addition, the field samplers are deployed in the field at two locations (the Meuse River in Eijsden, The Netherlands from April to May, 2005 and Hamilton Harbour located at the western tip of Lake Ontario, ON, Canada from September to December, 2006). Polycyclic aromatic hydrocarbons are identified, and concentrations of fluoranthene and pyrene are estimated in the low ng/L range. The results from both sampling sites are within the expected ranges for environmental samples. This polymeric extraction phase has a high surface-to-volume ratio compared with SPME, which results in higher sensitivity and mass uptake, leading to the detection of lower levels of analytes that many other techniques are unable to achieve.

Journal Article↗

SPME in environmental analysis: biotransformation pathways.

Solid-phase microextraction (SPME) is an organic solvent-free sample preparation tool suitable for direct adsorption of analytes from the headspace or the aqueous phase of a matrix followed by desorption into a gas chromatograph (GC) or high-performance liquid chromatograph (HPLC) for subsequent analysis. The SPME technique is designed to accommodate the use of fibers coated with different polymers suitable for the extraction of chemicals with varied hydrophobic and polar properties. Also, the technique can minimize interference from other artefacts associated with complex samples, such as those encountered in biological matrices or reaction mixtures. The preceding characteristics of SPME make the technique suitable for real-time measurements of intermediate reaction products and, thus, able to provide insight into the fate of target chemicals and their degradation pathways. In the present article, the current state of knowledge on the use of SPME-GC and SPME-HPLC in the determination of frequently encountered environmental chemicals and their (bio)transformation pathways are critically reviewed. Future opportunities of SPME in real time in situ process monitoring such as the use of agricultural feed stocks to bio-based industrial products termed henceforth "process analytical chemistry" are also discussed.

Biotransformation↗

Analysis of the lidocaine metabolite 2,6-dimethylaniline in bovine and human milk.

2,6-Dimethylaniline (2,6-xylidine; 2,6-DMA) is a nasal carcinogen in rats. Humans may be exposed to this compound via several routes: 2,6-DMA is found in cigarette smoke; it is a pharmacologically inactive metabolite of some drugs (e.g., the local anesthetic lidocaine) and pesticides (e.g., metalaxyl); and it is an impurity in technical grade metalaxyl. The potential transfer of 2,6-DMA from mother to nursing infant via milk is of toxicological concern. Solid-phase microextraction with separation and detection using gas chromatography-mass spectrometry was optimized and used for the analysis of 2,6-DMA in milk. 2,6-DMA-d9 was synthesized and used for quantitation by the isotope ratio method. At a concentration of 5 ppb 2,6-DMA, the method detection limit was 0.20 ppb, and the relative standard deviation was 3.6%. Samples of milk were obtained from bovines administered lidocaine (2.9-3.9 mg/kg) during surgery. A breast milk sample was also obtained from a human donor who received 36 mg lidocaine during dental work. 2,6-DMA was present at levels ranging from 14.5 to 66.0 ppb in bovine milk and was detected at 1.6 ppb in the human milk sample. Our results demonstrate that 2,6-DMA, formed by the metabolism of lidocaine, is transferable to bovine and human milk.

Adult↗

A fatal human intoxication with the herbicide allyl alcohol (2-propen-1-ol).

Oral ingestion of allyl alcohol by a 55-year-old man resulted in death within 100 min. At autopsy, bloody, reddish fluid was found in mouth, larynx, esophagus, and trachea. The mucous membranes of the trachea, stomach, and duodenum were congested and inflamed. The stomach contained a pungent green-black fluid, and all internal organs exhibited a strong pungent odor. Toxicological analysis of blood identified allyl alcohol using solid-phase microextraction and gas chromatography-mass spectrometry. Quantitative determination of allyl alcohol and its toxic metabolite, acrolein, was performed using headspace gas chromatography with flame-ionization detection. Total amounts of allyl alcohol in gastric content, bile, and urine were 3.6 g, 15 mg, and 0.5 mg, respectively. The concentration in blood was 309 mg/L. Acrolein was not detected in gastric contents and only in small amounts in bile and urine. The concentration of acrolein in blood was 7.2 mg/L. Death was attributed to acrolein-induced acute cardiotoxicity, similar to that previously documented in animal experiments.

Acrolein↗

Measurement of trihalomethanes and methyl tert-butyl ether in whole blood using gas chromatography with high-resolution mass spectrometry.

The prevalence of disinfection by-products in drinking water supplies has raised concerns about possible adverse health effects from chronic exposure to these compounds. To support studies exploring the relation between exposure to trihalomethanes (THMs) and adverse health effects, an automated analytical method was developed using capillary gas chromatography (GC) and high-resolution mass spectrometry (MS) with selected ion mass detection and isotope-dilution techniques. This method quantified trace levels of THMs (including chloroform, bromodichloromethane, dibromochloromethane, and bromoform) and methyl tert-butyl ether (MTBE) in human blood. Analyte responses were adequate for measuring background levels after extraction of these volatile organic compounds with either purge-and-trap extraction or headspace solid-phase microextraction (SPME). The SPME method was chosen because of its ease of use and higher throughput. Detection limits for the SPME GC-MS method ranged from 0.3 to 2.4 ng/L, with linear ranges of three orders of magnitude. This method proved adequate for measuring the THMs and MTBE in most blood samples tested from a diverse U.S. reference population.

Environmental Monitoring↗

Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

Adult↗

Attraction of Culex pipiens pipiens (Diptera: Culicidae) to flower volatiles.

Methylene chloride extracts of flowers from 4 plants (common milkweed, Asclepias syriaca L; ox-eye daisy, Leucanthemum vulgare Lamarck; Canada goldenrod, Solidago canadensis L.; and yarrow, Achillea millefolium L.) were tested in a dual-port olfactometer for attractiveness to female northern house mosquitoes, Culex pipiens pipiens L. Fifty milligrams of extract was used for each test, which was equivalent to the amount of extract from flowers of 0.58 common milkweed inflorescences, 1.75 ox-eye daisy flower heads, 0.33 Canada goldenrod plants, or 3.14 yarrow plants. Significantly more Cx. pipiens responded to the common milkweed flower extract than to a control. Ox-eye daisy, Canada goldenrod and yarrow flower extracts were not significantly attractive to this species. A headspace sample of the common milkweed extract was collected by solid phase microextraction and analyzed by gas chromatography-mass spectrometry. The most abundant compounds in the headspace sample were 2-phenylethanol and benzyl alcohol. Analysis of the common milkweed extract and standards of 2-phenylethanol and benzyl alcohol by gas chromatography-flame ionization detection confirmed that these compounds were present in the extract. Cx. pipiens did not respond to synthetic blends of these 2 compounds when tested in a dual-port olfactometer.

Animals↗

Evaluation of extracts and oils of mosquito (Diptera: Culicidae) repellent plants from Sweden and Guinea-Bissau.

In laboratory tests, ethyl acetate extracts of Hyptis suaveolens Poit. from Guinea-Bissau and Rhododendon tomentosum (Stokes) H. Harmaja (formerly Ledum palustre L.) and Myrica gale L. significantly reduced probing activity of Aedes aegypti (L.). In the field in southern Sweden, extracts of leaves of R. tomentosum, M. gale, and Achillea millefolium L. significantly reduced biting by Aedes mosquitoes. Volatile compounds from M. gale, R. tomentosum, A. millefolium, and H. suaveolens were collected by solid phase microextraction (SPME). Alternatively, compounds in the plants were subjected to extraction by organic solvents of different polarities or by steam distillation and collection by SPME. Compounds collected were identified by gas chromatography-mass spectrometry. Leaves of H. suaveolens contained mainly beta-caryophyllene, bergamotene, and terpinolene. The volatile fraction of an ethyl acetate extract of H. suaveolens was collected by SPME and included beta-caryophyllene, (-) -sabinene, beta-pinene, limonene, alpha-pinene, and bergamotene. The main volatiles detected were alpha-pinene, alpha-phellandrene, myrcene, and limonene from M. gale leaves or inflorescences; pcymene, sabinene, and terpinyl acetate from leaves of R. tomentosum; and (-)-germacrene D, beta-pinene, sabinene, and alpha-pinene from A. millefolium leaves or inflorescences. The selected plant species contained numerous volatiles known to have insecticidal, acaricidal, "pesticidal," and/ or insect repellent properties.

Acetates↗

Xenoestrogenicity in in vitro assays is not caused by displacement of endogenous estradiol from serum proteins.

The possibility that compounds tested for estrogenicity can compete for binding places on serum proteins and cause an increase of available and very potent endogenous estrogens is of great interest for both the in vitro assay results and the prediction of risk for humans. In in vitro assays, small amounts of estradiol remaining after the charcoal stripping of serum applied in the culture medium could be displaced by the tested compounds, leading to an estrogenic response that might be falsely attributed to the test compound. We have studied the stripping efficiency of charcoal and measured whether reported xenoestrogens can displace estradiol from serum in an in vitro assay using negligible depletion-solid phase microextraction (nd-SPME). Possible competition was also studied with a mathematical exposure model, from which the predictions were compared to the measurements. We found that the common charcoal stripping procedure removed 99% of initially present estradiol. Additionally, our results with charcoal adsorption indicate that charcoal is not useful for serum protein binding assays, as it adsorbs more than the free fraction of ligand. Although the competition model predicted a displacement of estradiol from the serum proteins at the higher applied doses of xenoestrogen, the measurements showed no displacement. Therefore, we conclude that estrogenic responses in the in vitro assay applied here are not caused by displacement of remaining estradiol in the stripped serum. The possibility remains, however, that our displacement hypothesis does apply for estrogen sulfates, as these are present in much higher concentrations than estradiol in stripped serum.

Adsorption↗

A simple method for detecting plasma propofol.

IMPLICATIONS: We measured plasma propofol levels by head space-gas chromatography analysis using solid-phase microextraction. This method saves time, and does not require elimination of interfering substances in the plasma. The coefficient variation was +/-5% to +/-30%. The detection limit was 10 ng/mL.

Anesthetics, Intravenous↗

Toxicology and evaluation of microcystins.

This paper reviews the toxicity and tumor-promoting properties of microcystins. Methods for screening and/or identification of microcystins in environmental samples are discussed and compared. Specific emphasis is placed on newly developed extraction/detection methods, e.g., solid phase microextraction (SPME) technique, and capillary electrophoresis coupled with laser-induced fluorescence detection. The results of a kinetic analysis of the effects of microcystins on phosphorylase-a binding to phosphatase-2A using a surface plasmon resonance biosensor are also presented.

Animals↗

Accidental autoerotic death by volatile substance abuse or nonsexually motivated accidents?

In contrast to typical autoerotic fatalities, when death is due to asphyxia mostly by mechanical compression of the neck, atypical autoerotic accidental deaths (AADs) involve sexual self-stimulation by other means such as electrocution or inhalation of chemical agents. Especially in lethal cases of volatile substance abuse (VSA), a differentiation between suicide or sexually or nonsexually motivated accident is often complicated in practical casework. Considering the small number of AADs involving chemical substance abuse reported in the literature, the number of unreported cases seems to be very high. We report about 5 lethal cases of VSA; analysis was performed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC/MS). When headspace sampling is not performed at autopsy, the analysis of volatile substances can be very complicated. In 2 cases, an AAD was diagnosed considering findings at the scene, reconstruction of the event, and discussion of the circumstances of the death. These findings demonstrate the importance of VSA in atypical autoerotic asphyxia. Therefore, in cases of suspected lethal inhalational intoxications, as a matter of principle, headspace asservation should be performed at autopsy and an autoerotic motivational background should be taken into consideration for differential diagnosis.

Accidents↗