PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Isometric”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Accurate assessment of in situ isometric contractile properties of hindlimb plantar and dorsal flexor muscle complex of intact mice.

An isometric torque sensor for measuring in situ contractions of plantar or dorsal flexors of intact mouse hindlimb has been developed and evaluated. With this device, muscle torque can be accurately measured within the range of -14 mN.m to +14 mN.m. Special attention was paid to fixation of the mouse hindlimb to the measurement device. Halothane-anaesthetized Swiss wild-type mice were positioned on the thermostatic measurement platform, and fixated with a hip and foot fixation system. The novel fixation unit was evaluated by measuring knee and ankle displacements during a contraction. A mathematical muscle model was used to quantify the effects of these displacements on the contractile parameters. Measured ankle and knee displacement, due to non-absolute fixation. resulted in a calculated muscle fibre shortening of 2.5%. Simulations of a contraction with this degree of fibre shortening, using the mathematical muscle model, showed only minor effects on maximal torque generation and the temporal parameters (half-relaxation time and 10-50% rise time). Furthermore, we showed that muscle torque in our set-up is hardly affected by eccentricity between ankle and measurement axis. Measured tetanic muscle torques of intact dorsal and plantar flexors were 3.2+/-0.4 mN.m and 11.8+/-1.6 mN.m, respectively. The half-relaxation time of plantar flexors was significantly higher than that of dorsal flexors (12.9+/-2.7 ms versus 8.8+/-1.2 ms), whereas the 10-50% rise time was longer in plantar (14.9+/-0.6 ms) than in dorsal (11.8+/-2.0 ms) flexors.

Animals↗

Intramuscular pressure, tissue oxygenation and EMG fatigue measured during isometric fatigue-inducing contraction of the multifidus muscle.

Simultaneous measurement of intramuscular pressure (IMP), tissue oxygen partial pressure (pO(2)) and EMG fatigue parameters in the multifidus muscle during a fatigue-inducing sustained muscular contraction. The study investigated the following hypotheses: (1) Increases in IMP result in tissue hypoxia; (2) Tissue hypoxia is responsible for loss of function in the musculature. The nutrient supply to muscle during muscle contraction is still not fully understood. It is assumed that muscle contraction causes increased tissue pressure resulting in compromised perfusion and tissue hypoxia. This tissue hypoxia, in turn, leads to muscle fatigue and therefore to loss of function. To the authors' knowledge, no study has addressed IMP, pO(2) and EMG fatigue parameters in the same muscle to gain a deeper sight into muscle perfusion during contraction. As back muscles need to have a constant muscular tension to maintain trunk stability during stance and locomotion, muscle fatigue due to prolonged contraction-induced hypoxia could be an explanation for low back pain. Sixteen healthy subjects performed an isometric muscular contraction exercise at 60% of maximum force until the point of localized muscular fatigue. During this exercise, the individual changes of IMP, pO(2) and the median frequency (MF) of the surface EMG signal of the multifidus muscle were recorded simultaneously. In 12 subjects with a documented increase in intramuscular pressure, only five showed a decrease in tissue oxygen partial pressure, while this parameter remained unchanged in six other subjects and even increased in one. A fall in tissue pO(2) was associated with a drop in MF in only five subjects, while there was no correlation between these parameters in the other 11 subjects. To summarize, an increase in IMP correlated with a decrease in pO(2) and a drop in MF in only five out of 16 subjects. High intramuscular pressure values are not always associated with a hypoxia in muscle tissue. Tissue hypoxia is not automatically associated with a median frequency shift in the EMG signal's power spectrum.

Adult↗

Maximal isometric muscle strength: normative values and gender-specific relation to age.

To date, there have been very few studies on the age dependence of maximal isometric muscle strength (MIMS) in healthy subjects aged 20-80 years, based upon measurements of a large number of functional muscle groups (FMGs). Using a hand-held pull gauge it is possible to measure MIMS of nearly every FMG. The objectives of this study were to obtain normative values for MIMS, to evaluate differences in MIMS in relation to gender and body side and to compare the age dependence of muscle strength between women and men. In a convenience sample of 290 healthy women (aged 20-82 years) and 253 men (aged 21-79 years), MIMS of 51 FMGs was measured. For each FMG the age dependence of MIMS was depicted, side and gender specific, as percentile curves and was analysed using linear quantile regression analysis. MIMS was found to be significantly higher in men than in women and higher on the right than on the left side. A biphasic model with linear equations for strength medians was derived for each gender. The age at transition from phase 1 to phase 2 was 55 years (SD 8) for women and 49 years (SD 13) for men. During phase 1, MIMS did not decrease significantly. During phase 2, MIMS decreased in all FMGs in both genders with a steeper slope in women (-0.92) than in men (-0.63). The age dependence of MIMS differed significantly between women and men. The present study gives gender-specific equations which enable one to calculate normative values for MIMS, as measured with a pull gauge, based upon age. These normative values will allow an objective assessment of patients with diminished muscle strength as, for example, in myositis, rheumatoid arthritis and nerve root compression syndromes or in the elderly.

Adult↗

Norepinephrine levels in the coronary sinus in patients with cardiovascular diseases at rest and during isometric handgrip exercise.

In order to evaluate cardiac sympathetic nerve activity, plasma norepinephrine levels in the coronary sinus (NECS) and in the artery (NEA) were determined in 24 subjects with cardiovascular diseases and in six with functional murmur. The resting NECS was greater than NEA in 14 subjects with normal left ventricular end-diastolic pressure (LVEDP) (p < 0.001) and/or in 22 with normal cardiac index (p < 0.04), whereas NECS was not significantly different from NEA in the remaining patients with elevated LVEDP and/or with reduced cardiac index. Isometric handgrip exercise increased both NECS and NEA (p < 0.001). When subjects were divided into two groups according to the slope of the ventricular function curve (delta stroke work index/delta LVEDP), NECS during exercise was greater then NEA in the group having slopes of 1.0 or more (p < 0.01), but neither values significantly differed in the group with slopes of less than 1.0. In the latter group, cardiac NE overflow rat calculated from the difference between NECS and NEA multiplied by coronary sinus plasma flow, was significantly less than that of the former group before and during handgrip (p < 0.05 and p < 0.01, respectively). These results suggest that cardiac norepinephrine release into the coronary sinus is reduced in patients with impaired cardiac function.

Adolescent↗

Effects of nifedipine and verapamil on isometric and dynamic exercise in normal subjects.

Effects of single- and multiple-dose nifedipine and verapamil in 10 healthy men were compared with the effect of placebo during static and dynamic physical activity. Blood pressure (BP), heart rate (HR), and plasma catecholamine and plasma potassium levels were assessed and quantified at rest and at peak levels of 50% handgrip and at rest and peak treadmill activity during placebo, single- and at 2 multiple-dose levels of each of the drugs. Peak BP responses were blunted by a maximal dosage of 120 mg of verapamil administered twice daily during static activity. No blunting of HR response was observed. BP and HR did not change significantly at any dosage level of nifedipine during static exercise. During isotonic exercise the only significant alteration was a progressive decrease in the peak exercise HR with both verapamil and nifedipine. The plasma potassium level increased with both static and dynamic activity but to no greater level than that seen with placebo. Plasma norepinephrine concentration increased at rest after administration of maximal dosage of nifedipine during both isometric and isotonic phases of the study. This is probably related to the underlying mild to moderate increase in sympathetic tone induced by nifedipine. Overall, the hemodynamic responses to exercise are not blunted with calcium-channel antagonists at the dosages studied.

Blood Pressure↗

Abnormal left ventricular response to isometric exercise in pure, isolated aortic regurgitation: beneficial effects of nifedipine.

To examine the effects of nifedipine on the left ventricular (LV) functional response to isometric exercise in patients with aortic regurgitation (AR), 20 patients with isolated, moderate to severe AR performed 3 minutes of handgrip exercise at 33% of their maximal voluntary contraction, before and after administration of 20 mg of sublingual nifedipine. Although handgrip exercise produced similar increases in heart rate and systolic blood pressure before and after nifedipine treatment, heart rate was higher and systolic blood pressure lower with handgrip exercise during nifedipine treatment. LV end-diastolic volume index was not different during the control period and nifedipine handgrip exercise, but the increase in end-systolic volume index was smaller and the ejection fraction was higher during nifedipine handgrip exercise. Nifedipine reduces afterload and ameliorates handgrip exercise-induced LV dysfunction in patients with AR.

Adult↗

Estimation of blood flow by 133Xe clearance in human masseter muscle during rest, endurance of isometric contraction, and recovery.

Sixty-four measurements of 133Xe clearance from the masseters of 9 individuals, who had no facial or oral pain, were used to evaluate changes in intramuscular blood flow (IMBF) caused by endurance of isometric contraction at approx. 50 per cent of maximum voluntary EMG activity. On average, the IMBF during endurance increased by 4.2 times in 6 individuals and decreased 62 per cent of the rest flow in 3 individuals. Overall, the group average of endurance flow was 2.5 times higher than the initial rest flow. The group average of post-endurance hyperaemia was 27 times higher than the initial rest flow and 11 times higher than the endurance flow. IMBF during the final rest was 1.7 times higher than the initial rest flow. The relative IMBF during endurance was negatively correlated to muscle effort, and the post-endurance flow in relation to the endurance flow presented a compensatory positive correlation to the muscle effort. Although the average IMBF tended to increase during endurance, it was insufficient to meet the demand of the much higher relative increase in muscle activity, as indicated by the pronounced post-endurance hyperaemia, especially after long endurance.

Adult↗

Measurements of the isometric contractile forces generated by dog periodontal ligament fibroblasts in vitro.

One hypothesis for the mechanism of tooth eruption is that the periodontal ligament fibroblasts generate the eruptive force. To assess the force generated, these fibroblasts were obtained by explant culture of ligament from mandibular premolars of a dog and were cultured in collagen gel matrices. The forces generated by them under isometric conditions were continuously measured for 120 h with a strain gauge. At the same time the number of cells in the gel was counted and the force measured was calculated as the force generated by 10(4) cells. Shortly after the start of culture, the force per 10(4) cells increased rapidly; it reached 5.2 X 10(-4) N at 8 h, and then remained at the same level for about 48 h. Our findings suggest that fibroblasts of the periodontal ligament may generate sufficient force for tooth eruption.

Animals↗

The precision of motor control in human jaw and limb muscles during isometric contraction in the presence of visual feedback.

Experiments showed that the human capacity to maintain a particular isometric force in the presence of visual feedback during a force-level, pursuit-tracking experiment is less developed for the jaw-closing muscles than for the limb muscles. This finding may indicate that the projection on the trigeminal motoneurone pool from visual inputs is poor, or that the trigeminal effector system itself is less finely tuned.

Adult↗

Influence of visual feedback on human isometric bite-force tremor.

In contrast to recent reports, during an isometric short forceful bite, visual feedback had a significant influence on the force tremor spectrum. The value of a 'half-value frequency', being the frequency f1/2 at which, with increasing frequency, the amplitude of the spectrum for the first time drops to half its initial value, was used as an indicator for the spectral behavior. Under visual feedback, the amplitude contribution to the force spectrum in the 3-5 Hz frequency range was much larger than after deprivation of visual feedback. Elevations in the frequency range between 3 and 5 Hz in the force spectrum are interpreted as an expression of a visual feedback loop with a tau between 100 and 200 ms. This is supported by the visual/oral reaction times recorded, which were between 110 and 190 ms.

Adult↗

An analysis of frequency response of motor units during voluntary isometric contractions at various speeds.

To ascertain the differences in discharge properties of a hand muscle between ramp and ballistic contractions, firing frequencies of 48 motor units of adductor pollicis muscle were analyzed during 3-kg isometric voluntary contractions at various force speeds. The force exertions were classified into 3 degrees: slow ramp, fast ramp, and ballistic contractions. The instantaneous frequencies (IFs) of motor units increased gradually when the force exertions were progressed to the target in slow and fast ramp contractions. The slopes of the linear regression equations between IFs and force levels were almost all constant during slow ramp contractions and were scattered slightly during fast ramp contractions. However, the slopes during ballistic contractions scattered widely. The y-intercepts of the same regression lines increased slightly with respect to the increment of force speed when slow and fast ramp contractions were performed. However, a remarkably wide variation of the y-intercepts was observed during ballistic contractions. Motor units could be fired at high frequencies at the beginning of discharge when ballistic contractions were performed as compared with slow and fast ramp contractions.

Adult↗

Modulation of cutaneous cortical evoked potentials during isometric and isotonic contractions in the monkey.

The effects of the direction of movement (flexion vs extension) and the nature of the motor task (isotonic vs isometric) on the modulation of sensory cortical evoked responses to cutaneous stimulation were investigated in one monkey. Sensory responses were assessed by measuring the magnitude of the short latency component of air puff-evoked potentials recorded intracortically in the arm representation of areas 3b and 1 in the primary somatosensory cortex. At most recording sites, it was found that the amplitude of the air puff-evoked potential was decreased in a non-specific manner by motor activity. Neither the timing nor the depth of the modulation were found to vary with either the direction or the type of contraction. The effects were widespread since inputs from practically the entire forelimb (hairy skin) were diminished during the motor tasks. These results thus show that the modulation was more closely linked to the central motor output than to the peripheral input generated by muscle force and/or limb displacement. It is suggested that signals originating from central motor structures, acting in a feedforward manner, play a major role in 'gating' cutaneous inputs during movement. It is further suggested that the centrally mediated effects are exerted via a final common pathway upon which the 'gating' signals converge.

Animals↗

Instability of motor unit firing rates during prolonged isometric contractions in human masseter.

The firing patterns of up to 4 concurrently active masseter motor units were studied with intramuscular electrodes during a continuous isometric contraction of 15 min duration, in which the subject maintained the mean firing rate of one selected unit at 10 Hz. With this paradigm the net excitation (i.e. mean firing rate) of one unit in the muscle was controlled. This served as the reference for the functional state of other active units during the prolonged contraction. With the mean firing rate of one unit in the muscle fixed, 58% of other active units showed a slow, statistically-significant change in mean firing rate over the 15 min. The initial firing rate of the units did not influence the change in rate. The original firing rate hierarchy, which in short-term contractions reflects the recruitment order, was altered during the prolonged contraction. The explanation for these differential changes in motoneuron net excitation is not clear; they could be intrinsic to the motoneurons or perhaps mediated by reflex pathways. The selective facilitation or suppression of some motor units with continuous activation means that the original size-structured combination of motor units can be modified during a prolonged contraction.

Adolescent↗

Isometric and isokinetic back and arm lifting strengths: device and measurement.

This study was conducted to measure isometric (static) and isokinetic (dynamic) back and arm lifting strengths at 20, 60 and 100 cm s-1 of young adults. Ten male and ten female volunteers without a history of back pain participated. The isokinetic lifting task was achieved by controlled motorized dynamic strength tester (DST). A regression analysis and analysis of variance was carried out on the strength data. The peak static strength values were significantly greater from the peak dynamic strength values. The peak dynamic strength was inversely related to the speed of motion. There were significant differences between the dynamic strengths at different stages of lift.

Adult↗

A comparison of three muscle pennation assumptions and their effect on isometric and isotonic force.

Three different pennation angle assumptions are compared to experimental data from Huijing and Woittiez (Neth. J. Zool. 34, 21-32, 1984) that relate fibre length to angle of pennation changes. The assumptions tested are: (1) neglecting pennation; (2) assuming a fixed pennation; and (3) assuming a constant muscle volume and thickness resulting in pennation angle being dependent on fibre length. Each assumption is compared by transforming fibre force/length and force/velocity characteristics to muscle properties. In general, the fixed pennation assumption provides the worst estimate of muscle force output with a peak error of 0.31 Fo during isometric contractions at small muscle lengths. A better estimate of muscle force output was provided by neglecting pennation entirely. The assumption that the pennation angle changed with fibre length maintained an error of less than 0.05 Fo for most lengths and velocities tested and provided the best estimate of muscle force output.

Elasticity↗

The isometric length-force models of nine different skeletal muscles.

The length-force relations of nine different skeletal muscles in the hindlimb of the cat were determined experimentally, with electrical stimulation of the sciatic nerve as the activation mode. It was shown that the active-, passive-, and total-force patterns varied widely among the muscles. The tibialis posterior (TP), medial and lateral gastrocnemius (MG, LG) and flexor digitorum longus (FDL) had a symmetric active-force curve, whereas the tibialis anterior (TA), peroneus brevis (PB), peroneus longus (PL), extensor digitorum longus (EDL), and soleus (SOL) had an asymmetric curve which exhibits about 25% of the maximal isometric force at extreme lengths. The SOL, EDL, and LG had a low-level passive force which appeared at short muscle length, whereas all other muscles exhibited initial passive force just before the optimal length. The total force was rising quasi-linearly for the SOL, whereas the other muscles exhibited an intermediate plateau about the optimal length. The LG and FDL had a substantial but temporary intermediate dip in the total force as the muscle was elongated past the optimal length. The elongation range of the various muscles also varied, ranging from +/- 15 to +/- 30% of the optimal length. The elongation range was symmetric for the FDL, LG, MG, TP, SOL, and EDL, and asymmetric for the PL, PB, and TA, being -12 to + 17%, -12 to + 17%, and -35 to + 12%, respectively. Two different models which incorporate muscle architecture were successfully fitted to the experimental data of the muscles except for the MG and TA. The architecture of these two muscles is highly nonhomogeneous and contains compartments with two pennation patterns or two different optimal lengths. New models, which add spatially and temporally the individual characteristics of each compartment of the muscles, were constructed for these two muscles. The new models demonstrated high correlation to the experimental data obtained from the MG and TA. It was concluded that the length-force relation varies widely among various skeletal muscles and is probably dependent on the primary function of the muscle in the context of integrated movement; this is a manifestation of architectural factors such as fiber pennation pattern and angle, cross-sectional area, ratio of muscle to tendon length, distribution of the fiber length within the muscle and compartmental pennation.

Animals↗

Effect of initial upper-limb alignment on muscle contributions to isometric strength curves.

Male and female isometric strength curves for elbow fixation, shoulder flexion, and wrist supination-pronation are obtained during systematic variation in arm configuration. The shape of a given moment-angle curve is found to be a function of the orientations of joints kinematically coupled to the primary joint. It is also found that female elbow strength curves are shifted toward flexion with respect to male elbow-strength curves, suggesting that the in situ rest length of upper-limb muscles relative to joint angle may be longer for males than for females. Experimental results were contrasted with simulation results obtained using a three-dimensional musculoskeletal model which estimates the relationships between initial joint orientations, muscle tension-length behavior, and joint moments. In most of the cases, simulation results complimented experimental data and provided insights into likely in situ muscle rest lengths and moments arms, especially for the multiarticular biceps brachii muscle. Where inconsistencies exist between simulated and experimental data, subtle biomechanical complexities within the forearm and the shoulder girdle complex are identified that require future investigation.

Adult↗

Load-sharing patterns in the shoulder during isometric flexion tasks.

Patterns of load-sharing between the shoulder muscles during isometric flexion tasks were studied by using both a biomechanical shoulder model and electromyographic (EMG) recordings of ten subjects. The effect of changes in several model parameters and shoulder stiffness constraints on the predicted load-sharing patterns were studied, while the arm position, hand load and precision requirements of the tasks were varied. The results calculated using the model were, when compared to the EMG recordings, plausible predicting a high level of synergistic contraction of muscles of the shoulder muscles during flexion tasks. The trends of the model-predicted muscle forces corresponded well to the EMG recordings. At low hand load levels the increasing of the shoulder stiffness strongly increased the muscle force levels, thus increasing also the level of synergistic contraction of muscles. At higher load levels the increase in the muscle forces was not so high, because the model predicted a high level of simultaneous contraction of muscles already at a low level of shoulder stiffness. Cluster analysis of the EMG recordings revealed large inter-individual differences in the load distribution patterns during flexion tasks. The constraint angle of the glenohumeral joint contact force direction was found to be an important model parameter affecting both the predicted forces and the maximum force production ability of the shoulder.

Adult↗