Termination of ventricular tachycardia by carotid sinus stimulation.

A 56-year-old white male developed sustained ventricular tachycardia which was terminated by carotid sinus stimulation. Intracardiac electrophysiologic study reproduced the tachycardia which was repeatedly terminated by carotid massage. This report, together with others reviewed here, suggests that tachycardia termination by simple carotid stimulation does not always prove a supraventricular origin.

Carotid Sinus↗

Development of a flow injection analysis (FIA) immunosensor for the detection of Escherichia coli.

A flow injection immunoanalysis (FIA) system has been developed for the detection of Escherichia coli in artificially contaminated food samples. Anti-E. coli antibodies were covalently immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immunoreactor. After adsorption of the cells onto anti-E. coli antibody bound glass beads, 4-methylumbelliferyl-beta-D-glucuronide was injected into the system which was then hydrolyzed by the adsorbed E. coli cells containing beta-D-glucuronidase, an enzyme which is very specific to E. coli and to a few other strains of Shigella. Fluorescent 4-methylumbelliferone released from the enzymatic reaction was then detected by a fluorometer. Owing to the specificity of the antibody towards E. coli, the FIA system was very selective for detection of E. coli whereas Shigella boydii, another GUD-positive bacterium, did not give any response. The FIA system was successfully used for detecting as low as 5 x 10(7) CFU/ml E. coli in less than 30 min and was reusable for at least 300 repeated assays. The immunoreactor yielded reproducible results during 3 months of experimentation if stored overnight at 4 degrees C in carrier buffer containing 0.05 to 0.25% Tween 20.

Escherichia coli↗

Age-dependent decline in motor evoked potential (MEP) amplitude: with a comment on changes in Parkinson's disease.

Peak-to-peak measurement of the maximum amplitude motor evoked potential (MAXMEP) elicited by 20 consecutive transcranial magnetic stimuli recorded from the contracting thenar and hypothenar muscles measured 9.8 +/- 2.0 mV and 7.25 +/- 2.9 mV respectively (P less than 0.01). The ratio of MAXMEP/CMAP measured 92.6 +/- 25.8% and 54.8 +/- 12.3% respectively (P less than 0.001). Repeat studies showed good individual reproducibility. Amplitudes declined linearly with age (r = -0.836 for thenar MAXMEP P less than 0.001). It is argued that MAXMEP related to age is more meaningful than the MEP/CMAP wave ratio and is proportional to the number of fast conducting cortical motor neurons excited. In 7/18 patients with Parkinson's disease (PD) MAXMEP was increased; in 2 other patients MAXMEP was decreased for their age.

Adult↗

Voltage sum of filtered ECG signal--a sensitive parameter of ventricular activation.

On the basis of the signal averaged ECG (SA ECG) principle the authors analyse the gradually filtered ECG signal (in ranges of 0-120 Hz with increments of 10 Hz). The voltage sums are determined in eight segments of the QRS complex. The described VSF-ECG method (Voltage Sum of Filtered ECG) was applied in a group of healthy probands and in groups of selected patients. The measurements in healthy probands were used to determine the value of standard in healthy subjects. Repeated measurements confirmed a good reproducibility of the VSF-ECG method. The method enables a precise quantification of heart activation progression. VSF-ECG is a method revealing the changes of heart activation progression being not reflected as late potentials. Parameters of the method are indicators of activation splitting upon the infarction area and also an indicator of the electric milieu of the entire heart.

Action Potentials↗

An investigation of test-house variability in the mechanical testing of dental materials and the statistical treatment of results.

The suitability of a test for standard specification testing depends inter alia on the ability to repeat the tests in a reproducible manner at a number of test centres. This work involved the investigation of three tests currently proposed as standard specification tests for dental materials. It was found that one test (compressive strength of cements) is inappropriate for inclusion in standards due to an unacceptable variation in test results between test centres. The treatment of results suggested in standards should place less emphasis on the mean value of a relatively small number of test specimens and the use of a simple form of probability theory in which, say, 80 per cent of specimens are required to achieve a certain pass level. In some standards there may be a need to increase the numbers of test specimens significantly in order to achieve a more meaningful and reliable result. The use of Weibull statistics can be adopted as a means of identifying tests which are suitable for inclusion in standard specifications, although it is doubtful that a test at this level of sophistication is required or desirable for inclusion in the standards themselves.

Composite Resins↗

Actions of acetylcholine and nicotine on rat locus coeruleus neurons in vitro.

Intracellular recordings were made from neurons of the rat locus coeruleus in a slice of tissue cut from the pons and superfused in vitro at 37 degrees C. Both acetylcholine, in the presence of a muscarinic antagonist, and nicotine depolarized locus coeruleus neurons and increased the rate of action potential discharge. These effects persisted in a superfusing solution that contained no calcium ions and a raised magnesium ion concentration; because such solutions block synaptic potentials in the locus coeruleus, it was concluded that the acetylcholine and nicotine acted directly on the cell from which the recording was made. Acetylcholine-evoked depolarizations were blocked by hexamethonium or dihydro-beta-erythroidine, but not by alpha-bungarotoxin. Recordings of membrane current showed that acetylcholine and nicotine caused a net inward current, the amplitude of which increased linearly as the membrane potential was changed from -40 to -90 mV; the extrapolated reversal potential was about -20 mV (extracellular potassium concentration was 2.5 mmol/l). Depolarizations caused by nicotine declined during the presence of the agonist when the period of superfusion was continued for more than 2 min; repeated applications of nicotine evoked reproducible depolarizations only when the interval between them was at least 1 h. It is concluded that neurons of the rat locus coeruleus have nicotinic receptors with properties similar to those in peripheral ganglia with respect to reversal potential for the ion channel, insensitivity to alpha-bungarotoxin and propensity to desensitize.

Acetylcholine↗

The reproducibility of natural head posture: a methodological study.

Current clinical interest in natural head posture (NHP) derives from studies correlating NHP to craniofacial morphology, future growth trends, and to respiratory needs. It has also been argued that NHP is the logical reference and orientation position for craniofacial analysis and the publication of illustrations. The individual or group is presented as they naturally appear in life. Hence, lateral cephalometric radiographs recorded routinely in NHP would be more meaningful for the clinician. Underpinning all these potential clinical benefits is the incompletely answered question of the clinical reproducibility of NHP. In this study a natural head posture, the orthoposition, was defined and standardized for clinical use. The effects of ear posts, an external source of eye reference (a wall mirror), sex and time were evaluated in relation to the reproducibility of recording lateral cephalometric radiographs in this natural head posture. The sample comprised 217 randomly selected 12-year-old Chinese children in Hong Kong. Boys looked up more when changing from the self-balance position to the mirror eye reference position (mean change 2 degrees, P less than or equal to 0.001). No other significant male-versus-female differences were detected. NHP reproducibility was better with a mirror (with mirror, method error = 1.9 degrees, without mirror, method error = 2.7 degrees). No significant differences in reproducibility were detected between NHP recordings taken with and without ear posts. However, without ear posts the radiographs tended to be of poor quality. The reproducibility of same-day repeat radiographs recorded with ear posts and with a mirror (after 4 to 10 minutes and 1 to 2 hours) was 1.9 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)

Cephalometry↗

A simple and fast method for the simultaneous determination of polychlorinated biphenyls and polybrominated diphenyl ethers in small volumes of human serum.

A fast extraction and clean-up method for the simultaneous determination of PCBs and PBDEs has been developed. The procedure consisted of a solid-phase extraction (SPE) of the analytes on an Oasis HLB cartridge and the subsequent on-line fat elimination by directly dropping the eluate from the SPE cartridge onto a second cartridge containing layers of activated neutral silica gel and sulphuric acid modified silica gel. Detection limits using a gas chromatography coupled with an ion trap detector in the tandem mass spectrometry mode were from 0.03 to 0.3 pg/microL for PCBs and from 0.07 to 1.3 pg/microL for PBDEs. Repeatability (lower than 11%) and reproducibility (lower than 17%), expressed as relative standard deviation (RSD, n=4), were satisfactory. The feasibility of the method developed for the determination of the target compounds was evaluated by participation in several rounds of interlaboratory exercises involving human serum with a wide range of PBDE and PCB concentrations. The method has been applied to the evaluation of PBDEs and PCBs in human serum samples of up to 1 mL.

Chromatography, Gas↗

Release property of temperature-sensitive alginate beads containing poly(N-isopropylacrylamide).

The graft copolymer (APN) of alginate and poly(N-isopropylacrylamide) (PNIPAM) were synthesized and APN beads were prepared by dropping the aqueous solution of the copolymer into an aqueous solution of Ca(2+) solution. Alginate chains were employed to play a role in forming beads by electrostatic interactions with a multivalent ion, Ca(2+). Grafted PNIPAM segments were adopted to act as a valve for the pores of the beads, since they exhibit the properties of thermal contraction and expansion. The percent of release of blue dextran from APN beads was higher at 40 degrees C than at 25 degrees C. The difference in the release between two temperatures became more distinguishable when the content of PNIPAM in APN beads is higher. Below lower critical solution temperature (LCST), the expanded PNIPAM would close the pores of the beads, resulting in a lower release rate. Above LCST, the thermally contracted polymer would open the pores, resulting in a higher release rate. The percent of release from APN beads were investigated when the temperature of the release medium is altered. The release rate was relatively low at 25 degrees C. The temperature, however, changed up to 40 degrees C, a marked increase in the release rate was observed. These trends were found to be reproducible when the temperature was repeatedly altered between 25 and 40 degrees C. As a result, a stepwise response to the temperature alteration was obtained.

Acrylic Resins↗

Elemental analysis of soil samples for forensic purposes by inductively coupled plasma spectrometry--precision considerations.

Major and trace elemental composition provides a powerful basis for forensic comparison of soils, sediments and rocks. However, it is important that the potential 'errors' associated with the procedures are fully understood and quantified, and that standard protocols are applied for sample preparation and analysis. This paper describes such a standard procedure and reports results both for instrumental measurement precision (repeatability) and overall 'method' precision (reproducibility). Results obtained both for certified reference materials and example soils show that the instrumental measurement precision (defined by the coefficient of variation, CV) for most elements is better than 2-3%. When different solutions were prepared from the same sample powder, and from different sub-sample powders prepared from the same parent sample, the CV increased to c. 5-6% for many elements. The largest variation was found in results for certified reference materials generated from 23 instrument runs over an 18 month period (mean CV=c. 11%). Some elements were more variable than others. W was found to be the most variable and the elements V, Cr, Co, Cu, Ni and Pb also showed higher than average variability. SiO2, CaO, Al2O3 and Fe2O3, Rb, Sr, La, Ce, Nd and Sm generally showed lower than average variability, and therefore provided the most reliable basis for inter-sample comparison. It is recommended that, whenever possible, samples relating to the same investigation should be analysed in the same sample run, or at least sequential runs.

Forensic Medicine↗

Quantification of urinary etheno-DNA adducts by column-switching LC/APCI-MS/MS.

Lipid peroxidation induced etheno-DNA adducts are promutagenic and have been suggested to play a causal role in the development of human cancers. Therefore, human biomonitoring of etheno-DNA adducts in urine has been suggested as a potential marker for oxidative stress-related DNA damage. For quantitative determination, a column-switching LC/APCI-MS/MS method was developed for simultaneous analysis of epsilonAde, epsilondC, and epsilondA in human urine. Quantitative validation parameters (precision, within-day repeatability, and between-day reproducibility) yielded satisfactory results below 10%. Limit of quantification for epsilonAde, epsilondC, and epsilondA was 5.3 fmol, 7.5 fmol, and 1.3 fmol on column, respectively. Mean urinary excretion rates of a six healthy volunteers were 45.8 pmol epsilonAde/24 h, 96.8 pmol epsilondC/24 h, and 18.1 pmol epsilondA/24 h. The demonstrated levels of performance suggest a future applicability of this method to studies of cancer and other diseases related to oxidative stress in humans. To our knowledge, this is the first method described that allows simultaneous determination of epsilonAde, epsilondC, and epsilondA in human urine samples.

Biomarkers↗

Simultaneous analysis of several antiretroviral nucleosides in rat-plasma by high-performance liquid chromatography with UV using acetic acid/hydroxylamine buffer Test of this new volatile medium-pH for HPLC-ESI-MS/MS.

Zalcitabine (ddC), lamivudine (3TC), didanosine (ddI), stavudine (d4T), carbovir (CBV), zidovudine (AZT), tenofovir (PMPA) and its administrated form (tenofovir diisoproxyl fumarate, TDF), are nucleosides currently approved in HIV therapy. To facilitate pharmacokinetics studies, a specific reversed-phase high-performance liquid chromatography (HPLC) method was developed for their analysis in rat plasma. The method involved a quantitative recovery of these drugs from rat plasma by solid-phase extraction on Oasis HLB Waters cartridges followed by optimised HPLC separation on an Atlantis dC18 column with acetic acid-hydroxylamine buffer (ionic strength 5mM, pH 7)-acetonitrile elution gradient. Quantitation was performed by HPLC/UV at 260 nm. Linear calibration curves were obtained within a 30-10,000 ng/mL plasma concentration range. Correlation coefficients (r2) greater than 0.992 were obtained by least-squares regression and limits of quantification were in 30-90 ng/mL concentration range. Quantitative parameters (accuracy, intra-day repeatability and inter-day reproducibility) yielded satisfactory results. Finally, a new buffer, obtained with acetic acid and hydroxylamine, has been tested in HPLC/ESI-MS/MS and appears to be an efficient volatile buffer in the medium 5-7 pH range. Indeed, at pH 7 and low ionic strength (5 mM), its buffer capacity is one hundred times higher to that obtained for the usual acetic acid/ammonia buffer.

Acetic Acid↗

A structural model of the tetrodotoxin and saxitoxin binding site of the Na+ channel.

Biophysical evidence has placed the binding site for the naturally occurring marine toxins tetrodotoxin (TTX) and saxitoxin (STX) in the external mouth of the Na+ channel ion permeation pathway. We developed a molecular model of the binding pocket for TTX and STX, composed of antiparallel beta-hairpins formed from peptide segments of the four S5-S6 loops of the voltage-gated Na+ channel. For TTX the guanidinium moiety formed salt bridges with three carboxyls, while two toxin hydroxyls (C9-OH and C10-OH) interacted with a fourth carboxyl on repeats I and II. This alignment also resulted in a hydrophobic interaction with an aromatic ring of phenylalanine or tyrosine residues for the brainII and skeletal Na+ channel isoforms, but not with the cysteine found in the cardiac isoform. In comparison to TTX, there was an additional interaction site for STX through its second guanidinium group with a carboxyl on repeat IV. This model satisfactorily reproduced the effects of mutations in the S5-S6 regions and the differences in affinity by various toxin analogs. However, this model differed in important ways from previously published models for the outer vestibule and the selectivity region of the Na+ channel pore. Removal of the toxins from the pocket formed by the four beta-hairpins revealed a structure resembling a funnel that terminated in a narrowed region suitable as a candidate for the selectivity filter of the channel. This region contained two carboxyls (Asp384 and Glu942) that substituted for molecules of water from the hydrated Na+ ion. Simulation of mutations in this region that have produced Ca2+ permeation of the Na+ channel created a site with three carboxyls (Asp384, Glu942, and Glu1714) in proximity.

Amino Acid Sequence↗

Thy-1 immunolabeled thymocyte microdomains studied with the atomic force microscope and the electron microscope.

The atomic force microscope (AFM) and the transmission electron microscope (TEM) have been used to study the morphology of isolated mouse thymocyte microdomains and Thy-1 antigen distribution at the surface of these structures. AFM images were recorded in air in the contact mode on membrane vesicles deposited on previously heated tissue culture plastic sheets and indirectly immunolabeled for Thy-1 expression with colloidal gold-conjugated secondary antibodies. AFM images of untreated plastic plates showed a very characteristic network of streaks 20-200 nm wide. Heating the plastic removed the streaks and provided flat surfaces (r.m.s. 1 nm). This substrate allowed strong adsorption and homogeneous spreading of the vesicles and easy manipulations during immunolabeling experiments. Vesicles flattened on the substrate without losing their morphology. The 10-nm membrane-bound gold beads were reproducibly imaged without degradation by repeated tip scanning. The observed microdomains had a mean diameter of 184 +/- 76 nm, and 65% of them were specifically labeled. Images obtained with the TEM on the same vesicles, deposited on carbon-coated grids and negatively stained, confirmed the AFM observations. The size distribution of the microdomains was quite similar, but the number of beads per vesicle was significantly higher, and 76% of the vesicles were labeled. The difference may be explained 1) by removal of beads from the vesicles in the additional washing step with water, which was necessary for the AFM; 2) by tip-sample convolution; and 3) by statistical fluctuations.

Animals↗

Development and validation of a liquid chromatographic-electrospray tandem mass spectrometric multiresidue method for anthelmintics in milk.

A liquid chromatographic-tandem mass spectrometric multiresidue method for the simultaneous quantitative determination of the tetrahydroimidazole, levamisole and the benzimidazoles thiabendazole, oxfendazole, oxibendazole, albendazole, fenbendazole, febantel and triclabendazole in milk has been developed and validated. The anthelmintic residues were extracted with ethyl acetate. The liquid chromatographic separation was performed on a reversed-phase C18 column with gradient elution. The analytes were detected by tandem quadrupole mass spectrometry after positive electrospray ionisation by multiple reaction monitoring. The confirmatory method is very sensitive and each component can be detected at a residue level lower than 1 microgram/l. The method is validated according to the revised European Union requirements and all parameters were found conform the criteria. The evaluated parameters were linearity, specificity, stability, recovery, precision (repeatability and within-laboratory reproducibility) and analytical limits (detection limit, decision limit and detection capability). This analytical method is applied in the Belgian monitoring programme for classical anthelmintic veterinary drugs in raw farm cow's milk.

Animals↗

Determination of the antibiotic chloramphenicol in meat and seafood products by liquid chromatography-electrospray ionization tandem mass spectrometry.

A confirmatory method based on isotope dilution liquid chromatography-electrospray ionization tandem mass spectrometry is described for the determination of the antibiotic chloramphenicol (CAP) in foods. The method is quantitative and entails liquid-liquid extraction followed by a clean-up step on a silica gel solid-phase extraction cartridge. Mass spectral acquisition is done in the negative ion mode applying multiple reaction monitoring of two diagnostic transition reactions for CAP (m/z 321 --> 257 and m/z 321--> 152). In addition, the presence of two chlorine atoms in the CAP molecule provides further analyte certainty by assessing the 37Cl/35Cl ratio using the transition reactions m/z 323 --> 257 and m/z 323 --> 152. Validation of the method in chicken meat is conducted according to the latest European Union criteria for the analysis of veterinary drug residues at levels of 0.05, 0.10, and 0.20 microg/kg, employing [2H5]-chloramphenicol as internal standard. The decision limit and the detection capability were calculated at 0.01 microg/kg and 0.02 microg/kg, respectively. At the lowest fortification level (i.e. 0.05 microg/kg), precision values below 14 and 17% were achieved under repeatability and within-laboratory reproducibility conditions, respectively. The accuracy of the method was within 20, 15, and 5% of the target values at the 0.05, 0.10, and 0.20 microg/kg fortification levels, respectively. The applicability of this procedure was demonstrated by the analysis of other meat (turkey, pork, beef) and seafood (fish, shrimps) products. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.

Anti-Bacterial Agents↗

Continuous ultrasound-assisted extraction coupled to on line filtration-solid-phase extraction-column liquid chromatography--post column derivatisation-fluorescence detection for the determination of N-methylcarbamates in soil and food.

A dynamic ultrasound-assisted method for the extraction of N-methylcarbamates (oxamyl, dioxacarb, metolcarb, carbofuran, carbaryl and isoprocarb) from soils and foods is proposed. The main factors affecting the extraction efficiency have been optimised by means of a central composite design. Pure water can be used as leaching agent. A flow injection manifold coupled to the extractor allows automation of the several steps involved in the analytical process. The method allows extraction of the carbamates from soil and food at 1 microg/g spiked level, with recoveries similar to those provided by the EPA 8318 method, without degradation of the target compounds during the extraction and with drastic shortening of the time required for this step (2 min vs. 4 h). Recoveries of the target analytes were 77-95% for spiked soil and 85-101% for spiked food. The detection and quantification limits were 12 and 40 ng/g, respectively, for all analytes, except carbaryl (detection and quantification limits 3 and 10 ng/ng, respectively). The relative standard deviations for repeatability and within-laboratory reproducibility were 3.1 and 7.5%, respectively.

Carbamates↗

Comparison of different chloroformates for the derivatisation of seleno amino acids for gas chromatographic analysis.

Three chloroformate reagents, ethyl chloroformate (ECF), methyl chloroformate (MCF) and menthyl chloroformate (MenCF), have been used for the derivatisation of seleno amino acids and their performance was compared. Chromatographic parameters and the inertness of the different instrumental configurations used (gas chromatography-atomic emission detection (GC-AED), and GC-MS) were shown to have a significant influence on the detection of various seleno amino acids (selenomethione, selenoethione and selenocysteine) and some sulphur-containing amino acids (methionine, cysteine, cystine and methylcysteine) which were included in the experiments for comparison. Methyl chloroformate was the preferred derivatisation reagent, since it generally performed best in terms of derivatisation yield and reproducibility and also showed less significant conditioning effects than ethyl chloroformate. Methyl and ethyl chloroformate derivatives of selenomethionine, selenoethionine, cysteine and methionine were detectable, while the detection of the menthyl chloroformate derivatives of selenocystine and cystine was not reproducible. Overall efficiencies for the determination of selenomethionine and selenoethionine from aqueous extracts ranged from 40 to 100% for methyl chloroformate, over 30-75% for ethyl chloroformate to 15-70% for menthyl chloroformate for different series measured over a period of months. The relative standard deviation of the method for the methyl and menthyl chloroformate derivatisation ranged from 7 to 13% without internal standard and was improved to 2% for the determination of selenomethionine using selenoethionine as internal standard. This indicates that, despite the limited reproducibility of the method, its repeatability is good enough to allow accurate determination of seleno amino acids, which was also demonstrated by the analysis of selenium supplementation tablets for human diet that contained selenomethionine.

Amino Acids↗