PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Color Perception Tests”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86Linked to original sources

Changes in colour appearance following post-receptoral adaptation.

Current models of colour vision assume that colour is represented by activity in three independent post-receptoral channels: two encoding chromatic information and one encoding luminance. An important feature of these models is that variations in certain directions in colour space modulate the response of only one of the channels. We have tested whether such models can predict how colour appearance is altered by adaptation-induced changes in post-receptoral sensitivity. In contrast to the changes predicted by three independent channels, colour appearance is always distorted away from the direction in colour space to which the observer has adapted. This suggests that at the level at which the adaptation effects occur, there is no colour direction that invariably isolates only a single post-receptoral channel.

Adaptation, Physiological↗

[Color vision in relation to age: a study of normal values].

BACKGROUND: It is difficult to quantify thresholds in most colour vision tests, and this is especially the case for tritan hues, where a strong age-related increase of threshold has been reported. With the development of computer-graphic methods it is possible to remove brightness clues caused by lens absorption. This study attempts to give normative values for colour contrast thresholds and assess the age related changes therein. PATIENTS AND METHODS: 115 patients aged between 6 & 71 years were tested for central and peripheral colour contrast sensitivity. No patient had any systemic or eye disease. As a preliminary, heterochromatic flicker balance between the luminosities of the R and G and B and G phosphors was established, so that all colours subsequently generated were isoluminant for the person tested. Then, using a modified binary search technique, colour contrast thresholds were established using both 2 degree optotypes, for central vision, and a ring, 12.5 degrees in radius for peripheral vision. In the latter case, the observer had to name the position of the missing quadrant in the ring. Stimuli were presented for 200 msec at 1 Hz. Colours were modulated on protan, deutan or tritan colour axis. RESULTS: No correlation between age and central colour vision thresholds was observed. By contrast a significant but only minor increase of peripheral colour vision threshold was observed for the peripheral protan and tritan axis. DISCUSSION: The present system removes luminance clues from colour vision tests and permits both central and peripheral retina to be tested. The results are simple in that the influence of age can be neglected. The variability of threshold results is small, and it is easy to detect the relatively large changes associated with disease. Since high-quality monitors are standardised and calibrated, providing the stimulus parameters described are adhered to, the results given here for upper limits of normal may be used for other similar systems.

Adolescent↗

[The chromatic characteristics of neuronal receptor fields in the visual cortex of the baronduki].

39 orientation-selective neurons and 25 neurons responding to total illumination of the receptive field were investigated by exposing to achromatic and chromatic stimuli. Switching on and off of the bar stationary stimuli has revealed that orientation-selective neurons were not chromatically opponent. But when they were tested by moving chromatic bars, pronounced maximum responses were found either to green (520-540 nm) or to blue (449-458 nm) colours. 7 neurons of 39 were either not activated by exposure to achromatic stimuli of any brightness or were slightly activated. Among 25 neurons responding to total illumination of receptive field, 5 neurons were chromatically opponent. They responded by prolonged tonic activation to the switching on of the green and switching off of the blue stimuli.

Animals↗

Optic nerve sheath decompression for nonarteritic ischemic optic neuropathy improves multiple visual function measurements.

Optic nerve sheath decompression was performed in seven patients with nonarteritic anterior ischemic optic neuropathy. Visual function was evaluated by measurement of visual acuity with standardized Early Treatment Diabetic Retinopathy Study charts, color vision testing, quantitation of relative afferent pupillary defects with neutral-density filters, and Goldmann and Humphrey perimetry. Visual acuity improved markedly in all patients (at least doubling of the visual angle); the peripheral visual field expanded by at least 20 degrees (as measured by Goldmann perimetry) in six patients. Three patients also experienced marked improvement in color vision, relative afferent pupillary defect, and foveal sensitivity. Our experience supports the possible beneficial effect of optic nerve sheath decompression in patients with nonarteritic anterior ischemic optic neuropathy.

Aged↗

A double-blind placebo-controlled evaluation of the acute effects of sildenafil citrate (Viagra) on visual function in subjects with early-stage age-related macular degeneration.

PURPOSE: To assess the effects of a single 100-mg dose of sildenafil citrate on visual function in men with early-stage age-related macular degeneration. DESIGN: Randomized double-blind placebo-controlled clinical trial. METHODS: Nine men (mean age 71 years, range 59-85 years) with early-stage (minimal visual impairment and large drusen in the macula) age-related macular degeneration and 20/40 or better-corrected visual acuity in at least one eye were prospectively randomized to receive either placebo or sildenafil citrate (Viagra; Pfizer Inc, New York, New York) 100 mg as a single oral dose. After 7-14 days, they received the alternate treatment. Subjects underwent visual acuity, Amsler grid, color discrimination (D15), traffic light, Humphrey perimetry, and photo-stress testing in each eye before and at specific intervals within 8 hours after dosing. RESULTS: Compared with placebo, no pattern of errors were evident in any visual function test following sildenafil administration. No statistically or clinically relevant changes from baseline were observed in visual acuity, Humphrey perimetry (corrected pattern standard deviation), D15 color discrimination, or photo-stress tests. No clinically relevant changes were observed in the Amsler grid or traffic light tests. Sildenafil treatment was associated with transient mild or moderate headache, flushing, and rhinitis. There were no visual adverse events spontaneously reported to the investigator. CONCLUSION: A single 100-mg dose of sildenafil was well tolerated and produced no acute visual effects or exacerbation of preexisting visual impairment in nine men with early-stage age-related macular degeneration.

3',5'-Cyclic-GMP Phosphodiesterases↗

Color appearance depends on the variance of surround colors.

BACKGROUND: The perceived color at each point in a visual scene depends on the relationship between light signals from that point, and light signals from surrounding areas of the scene. In the well known phenomenon of simultaneous color contrast, changing the overall brightness or hue of an object's surround induces a complementary shift in the perceived brightness or hue of the object's color. Color contrast is thought to contribute to color constancy with changes in illumination. RESULTS: We report a new type of simultaneous color contrast, in which changing only the variance (i.e. contrasts and saturations), but not the mean, of colors in a test spot's surround induces a complementary shift in the perceived contrast and saturation of the test spot's color. Objects appear much more vivid and richly colored against low-contrast, gray surrounds than against high-contrast, multicolored surrounds. CONCLUSIONS: Color appearance depends not just on the mean color of the surround, but also on the distribution of surround colors about the mean. This novel form of simultaneous color contrast is inconsistent with a variety of models of color appearance, including those based on sensitivity regulation at the receptor level, and those in which the effects of complex surrounds on color appearance can be reduced to adaptation to the illuminant or induction from a homogeneous 'equivalent surround'. It tends to normalize the gamut of perceived colors in each visual scene and may also contribute to color constancy under viewing conditions that affect contrast.

Color Perception↗

Contrast sensitivity in diabetics with retinopathy and cataract.

Contrast sensitivity responses were determined in diabetic subjects with retinopathy, macular disease and cataract. The test proved reliable in discriminating between different degrees of cataract and between diabetics with no retinopathy, mild background retinopathy and early maculopathy. Background retinopathy was shown to produce a loss of contrast sensitivity particularly at the low and medium frequencies. These thresholds increased with macular involvement. Mild cataract was correlated with loss at the low and medium spatial frequencies, whilst moderate cataract suppressed sensitivity to all frequencies. Results are compared to colour discrimination in each patient.

Adolescent↗

Lüscher color preferences of Arctic Inuit and of southern Canadians.

A comparison of color preferences based on the Lüscher Color Test was made for 21 Inuit residing within the Arctic circle and those of 49 residents of Southern Canada. These two groups have been raised in radically different physical and cultural environments. We expected that such factors could influence color preferences; however, no statistically significant differences were found in relative preferences for blue, green, red, yellow, purple, brown, grey, and black for our data based on Lüscher's scoring and those on our own scoring system independent of Lüscher's theory and scoring.

Adult↗

Visual dysfunction in Alzheimer's disease: relation to normal aging.

In patients with Alzheimer's disease (AD), compared with age-matched and young healthy control subjects, visual deficits in the following functions were observed: color, stereoacuity, contrast sensitivity, and backward masking (homogeneous and pattern). Critical flicker fusion thresholds were normal, relative to age-matched healthy subjects. For color, the majority of the errors were tritanomalous (blue axis). Color and stereoacuity deficits were unrelated to severity of dementia, in accordance with models of vision that describe these functions as modular rather than diffuse for cortical localization. Although contrast sensitivity was depressed throughout the frequency range in AD, more patients were impaired at low than at high spatial frequencies, contrasting with the observed normal aging pattern of high-frequency loss. Healthy elderly subjects showed depressed critical flicker fusion thresholds and reduced contrast sensitivity at high frequencies, relative to the young group; differences between these groups were not found for the other vision tests. A subset of the AD group received detailed neuro-ophthalmological examination, and no abnormalities were found. This finding, taken together with normal thresholds for critical flicker fusion, suggests that the widespread visual dysfunction reported here is more likely to be related to known pathological changes in primary visual and association cortex in AD than to changes in the retina or optic nerve.

Adolescent↗

Colour matching of isoluminant samples and backgrounds: a model.

A cone-opponent-based vector model is used to derive the activity in the red-green, yellow-blue, and achromatic channels during a sequential asymmetric colour-matching experiment. Forty Munsell samples, simulated under illuminant C, were matched with their appearance under eight test illuminants. The test samples and backgrounds were photometrically isoluminant with each other. According to the model, the orthogonality of the channels is revealed when test illuminants lie along either red-green or yellow blue cardinal axes. The red green and yellow-blue outputs of the channels are described in terms of the hue of the sample. The fact that the three-channel model explains the data in a colour-matching experiment indicates that an early form of colour processing is mediated at a site where the three channels converge, probably the input layer of V1.

Case-Control Studies↗

Retinopathy in systemic lupus erythematosus: relationship to disease activity.

Forty-three patients taking chloroquine for systemic lupus erythematosus were followed by one ophthalmologist over a 5-year period. Visual field testing, color vision testing, and fluorescein angiography were performed. Retinopathy was detected in 7 patients (16%), none of whom had hypertension or diabetes mellitus. Retinal abnormalities included cotton-wool spots in 4 patients, microaneurysms in 3, and vascular tortuosity in 4. In 4 patients, these abnormalities were associated with retinal dysfunction, measured in terms of abnormal hue discrimination. In 6 of the 7 patients, the finding of retinopathy coincided with a flare of lupus activity. In 5 patients, retinopathy improved when the disease was controlled.

Adult↗

Influence of rod adaptation upon cone responses to light offset in humans: II. Results in an observer with exaggerated suppressive rod-cone interaction.

In normal observers, sensitivity of cones to rapid sinusoidal flicker decreases by about 0.7 log units as rods progressively dark adapt. However, Arden and Hogg (1985) described a night-vision disorder characterized by normal rod sensitivity but exaggerated suppressive rod-cone interaction (SRCI). We refer to this condition as the exaggerated SRCI syndrome (ESS). The present paper examines the influence of rod-adaptation upon cone-mediated responses to light onset and offset in an observer with ESS. Under all conditions of adaptation examined, sensitivity of cones to rapid-on waveforms is indistinguishable to that of a normal observer tested under identical circumstances; rod sensitivity is also normal. However, the sensitivity of cones to transient decreases in illumination is clearly subnormal under light-adapted conditions. This deficit in cone responsiveness to light offset becomes increasingly subnormal as rods dark adapt and, when completely dark adapted, the ESS observer is nearly blind to 1 Hz rapid-off sawtooth waveforms. These results strongly bolster previous results that suggest that suppressive rod-cone interaction is restricted to the response to transient decreases in illumination.

Adaptation, Ocular↗

Colour matching of isoluminant samples and backgrounds: a dimming effect.

Sequential asymmetrical colour matching of forty Munsell samples simulated under illuminant C and one of eight test illuminants was carried out. The subjects matched the appearance of each sample under illuminant C with its appearance under the test illuminant. Samples and background (N7) were presented for 1 s under the test illuminant and were isoluminant with each other. Subjects adjusted hue, chroma, and value under illuminant C. The experiments distinguished two groups of subjects; some observers needed to reduce the luminance of the sample to make a match while others did not. This 'dimming' occurred when the matches were close to cardinal axes, especially the tritanopic confusion line. A model of luminance and cone-opponent mechanisms contributing to brightness can account for the dimming effect. Details of analysis in cone-opponent space (L - M, L + M - S, L + M) are presented in the companion paper (Stanikunas et al, 2005 Perception 34 this issue).

Adaptation, Ocular↗

Colour contrast thresholds are normal in functional amblyopia.

We evaluated colour contrast thresholds in patients with unilateral functional amblyopia. A computer-controlled colour vision test was used to determine colour contrast thresholds along a blue-yellow tritan axis. Prior to the threshold measurement, a heterochromatic flicker brightness test was performed to ensure isoluminance between the test stimulus and the background for every subject individually. Luminance contrast thresholds were also measured using the same computer-based system. Twenty amblyopic patients were tested. All showed normal tritan colour contrast thresholds both for their amblyopic eye and non-amblyopic fellow eye. Luminance contrast thresholds were elevated in all 6 refractive amblyopic eyes, in 4 of 9 strabismic eyes and in 2 of 5 mixed amblyopic eyes. Colour contrast thresholds are normal in functional amblyopia (with central fixation). Whenever elevated tritan colour contrast thresholds are found in patients with a decreased visual acuity, other causes of visual impairment are to be evaluated.

Adolescent↗

Visual losses in early age-related maculopathy.

Age-related maculopathy (ARM) can be considered a transition from normal retinal changes to pathological processes. It is important to recognize patients who have progressed beyond a normal state in order to provide appropriate clinical management. This pilot study considers the clinical dilemma of diagnosing and monitoring early ARM. We carried out a controlled study and tested the visual functions of 11 pre-ARM (PARM) and 11 early ARM subjects. Apart from compromised visual acuity, losses in central visual field, color vision, and visual adaptation were also recorded in our ARM subjects. We found a low contrast (LC) Amsler grid to be most sensitive to central field defects and that the desaturated panel D-15 gave too many false positives among normal elderly subjects. Our results indicate foveal sparing in early ARM and question the capacity of acuity assessment to reflect early functional changes adequately. A clinical battery is recommended to detect and monitor ARM.

Adaptation, Ocular↗

Delayed regeneration of foveal cone photopigments in Vogt-Koyanagi-Harada disease at the convalescent stage.

PURPOSE: To evaluate the physiological characteristics of the macula in patients with Vogt-Koyanagi-Harada disease during the convalescent stage with specific reference to the kinetics of foveal cone photopigment regeneration. METHODS: Six eyes of three patients at the convalescent stage of Vogt-Koyanagi-Harada disease were studied. All the eyes had best corrected visual acuity of 1.0 or better and had had no recurrence of inflammation for at least 12 months after the last episode. Foveal cone densitometry (FCD), focal macular electroretinograms, color vision tests, two-color perimetry, and optical coherence tomography (OCT) were performed. RESULTS: No regeneration of cone photopigments was detected within the 7-minute testing time by FCD in all eyes at the first examination after the last episode. However, the other functional tests were normal, and the OCT-determined macular morphology was also normal. The regeneration kinetics of the foveal cone photopigment improved in three of six eyes at 36, 37, and 19 months after the last episode, whereas the other three remained delayed at 18, 18, and 49 months. CONCLUSIONS: These findings suggest that a disorder of the foveal cone photopigment regeneration, and its recovery, requires a significantly longer time than that of other macular functions in some patients with Vogt-Koyanagi-Harada disease.

Adult↗

Effects of low-level occupational exposure to styrene on color vision: dose relation with a urinary metabolite.

To investigate the threshold effects of chronic low-level occupational exposure to styrene on color vision, we examined color discrimination in 105 male workers exposed to styrene (mean age 37.7 years; mean length of exposure 6.2 years; mean urinary concentration of mandelic acid 0.21 g/L) and in 117 referents (mean age 37.7 years). We also assessed the effects of styrene by examination of the nature of the relation between disorders of nervous function and age, alcohol consumption, and other variables. A standardized questionnaire was adopted to collect information about work history, occupational or nonoccupational solvent exposure, alcohol consumption, and drug use. Color vision was evaluated by the Lanthony desaturated panel D-15 test. The results of the test were expressed as the color confusion index (CCI). There was a dose-dependent relationship between the urinary concentration of mandelic acid and color vision loss. The CCIs of the subgroups whose urinary mandelic acid levels were 0.1-0.2 and >0.2 g/L were significantly higher than those of each referent group (P<0.05 and P<0.01, respectively), but not in the subgroup whose urinary mandelic acid level was lower than 0.1 g/L. Our study suggests that a low level of styrene, presumably 0.1-0.2 g/L, involves the risk of inducing adverse effects on color vision. After confounding factors were adjusted for, the urinary mandelic acid level had a significant positive relationship with color vision.

Adult↗

Blue-yellow perimetry in the detection of early glaucomatous damage.

A perimetric method using blue stimuli on a yellow background was compared with perimetry using white stimuli on a white background as a method of detecting glaucomatous damage. Meridian perimetry was used with an adapted Tübinger perimeter. The difference between the blue-on-yellow meridian and the white-on-white meridian was subdivided into two parts: the general blue sensitivity loss (GBSL), probably due to optical factors, and the corrected blue sensitivity loss (CBSL), probably due to glaucoma. Nine normals, fourteen primary open angle glaucoma (POAG) patients and nine ocular hypertensives (OHT) were tested. All POAG patients and some of the OHT group showed higher CBSL values than the controls. The blue-yellow meridian showed broader and deeper defects than the white-white meridian in all of the POAG group; some of the OHT group had defects in the blue-yellow meridian that were not present in the white-white meridian. In conclusion, blue on yellow perimetry shows promise as a method for more sensitive detection of early glaucomatous damage.

Adult↗