PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microbubbles”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86Linked to original sources

Perfusion imaging of the brain by B-mode ultrasonography. An experimental study in rabbits.

BACKGROUND AND PURPOSE: The purpose of this study was to assess the ultrasonic imaging of normal rabbit brain by using echocontrast enhancer to identify the brain tissue perfusion. METHODS: A solution of SH/TA-508 (containing microbubbles of mean size 2 to 4 microns; n = 4) was used for contrast enhancement of rabbit brain tissue and was administered through the left internal carotid artery. Contrast enhancement in the ipsilateral parietal area was examined by placing a 7.5-MHz transducer on the dura after a craniectomy. Throughout the experiment, we measured parameters including arterial blood pressure, arterial blood gases, and serum glucose and hematocrit levels. We investigated whether the administration of an echocontrast enhancer would be safe for the brain tissue (n = 4). RESULTS: After injection of 100 mg/mL SH/TA-508, contrast enhancement was clearly observed within approximately 1 second in the left hemisphere (especially in the left cerebral cortex) in all animals and disappeared within 3 seconds after the end of injection. All physiological parameters remained within the normal range throughout the experiment. No focal abnormalities were observed on hematoxylin-eosin staining of the brain tissue. CONCLUSIONS: Contrast enhancement was observed in the ipsilateral hemisphere with the administration of SH/TA-508. Contrast enhancement on B-mode brain imaging would be useful for real-time identification of brain tissue perfusion and should become a promising method for bedside clinical assessment of brain tissue perfusion.

Animals↗

Contrast-enhanced transcranial imaging. Results of an American phase-two study.

BACKGROUND AND PURPOSE: Pulsed color Doppler imaging of cerebrovascular structures permits rapid visual identification of the intracranial vessels. In some patients, however, the clinical utility of transcranial ultrasound examinations is limited by poor tissue penetration and inadequate imaging of vessels. This phase-two clinical trial evaluates whether administration of an echocontrast agent in such ultrasound-refractory patients enhances image acquisition enough to yield meaningful diagnostic impressions. METHODS: This is a phase-two clinical trial of safety and efficacy of the "galactose/palmitic acid-based microbubble preparation" Levovist injection (Berlex Laboratories). Thirty subjects with clinical indications for cerebrovascular imaging but refractory to transcranial Doppler studies were enrolled in a nonrandomized, single-center study. Echocontrast agent was administered intravenously in a tiered-dose protocol. Safety was determined by clinical and laboratory monitoring for 18 to 24 hours. Efficacy of contrast enhancement was determined by comparisons between each patient's precontrast (control) and postcontrast images. RESULTS: No significant patient discomfort, side effects, or adverse reactions occurred that were due to the intravenous administration of the echocontrast agent. Optimal image enhancement was obtained using the 300-mg/mL concentration (3 g bolus) of contrast. Visualization of both individual arterial segments and/or the entire circle of Willis was demonstrated. Clinical confidence of diagnostic impressions was achieved in 77% (23/30) of subjects. CONCLUSIONS: The transpulmonary ultrasound contrast agent (Levovist injection) was easily administered and found to be safe in the 30 patients studied and increased the diagnostic utility of transcranial ultrasound in 77% of the patients studied.

Adult↗

Microemboli in cerebral circulation and alteration of cognitive abilities in patients with mechanical prosthetic heart valves.

BACKGROUND AND PURPOSE: It has been shown previously that cerebral microemboli may occur frequently in patients with a normal mechanical heart valve (MHV) without prior history of stroke. Some arguments strongly suggest that these microemboli have a gaseous origin. In other circumstances such as extracorporeal circulation or decompression in divers, it has been demonstrated that cerebral microbubbles could lead to some deterioration in cognitive functions. Therefore, we have studied attention and memory, which are among the most impaired cognitive functions as demonstrated in previous studies, in patients with an MHV. METHODS: Three groups of 12 volunteers each were composed of patients with an MHV and embolic signals in the cerebral circulation (group 1), patients with biological prostheses (group 2), and healthy subjects (group 3). Groups were carefully matched for age and verbal intellectual abilities. For each group, a transcranial Doppler examination was performed and a set of cognitive tests assessing sustained and selective attention and episodic and working memory was administered. RESULTS: The mean embolic rate was 29 per hour in patients with an MHV. No embolus was detected in the other 2 groups. Episodic memory was significantly modified in both groups 1 and 2 compared with the control group for tasks that required high-processing resources. Working memory performance was significantly decreased in MHV patients. No between-groups differences were observed for the other parameters. CONCLUSIONS: Alteration of episodic memory can be attributed to a long-term effect of the surgical procedure. Deterioration of working memory can be related to the presence of cerebral microemboli in MHV patients.

Aged↗

Transient response harmonic imaging: an ultrasound technique related to brain perfusion.

BACKGROUND AND PURPOSE: Gray-scale harmonic imaging is the first method to visualize blood perfusion and capillary blood flow with ultrasound after intravenous contrast agent application. The purpose of the present study was to evaluate the potential of transient response second harmonic imaging (TRsHI) to assess normal echo contrast characteristics in different brain areas by transcranial ultrasound. METHODS: In 18 patients without cerebrovascular diseases, TRsHI examinations were performed bilaterally with the use of the transtemporal approach after application of 6.5 mL of a galactose-based microbubble suspension (400 mg/mL). The transmission rate was once every 4 cardiac cycles. Regional cerebral contrast was visually assessed and then quantified off-line with the use of time-intensity curves. In 4 different regions of interest (ROI) (posterior part of the thalamus [ROIa], anterior part of the thalamus [ROIb], lentiform nucleus [ROIc], and white matter [ROId]), the following parameters were evaluated: peak intensity, area under the curve (AUC), and time to peak intensity. AUC ratios for ROIc/a, d/a, c/b, and d/b were calculated. RESULTS: In all patients parenchymal contrast enhancement was visually detectable. One hundred thirty-one characteristic time-intensity curves (baseline phase, peak contrast intensity, slow washout phase) were demonstrable in 144 ROIs. In ROIc and ROId, characteristic contrast curves could be observed most frequently (68/72 examinations), whereas time-intensity curves in ROIa and ROIb could not be evaluated because of inadequate contrast enhancement in 9 of 72 examinations. Time to peak intensity varied between 20 and 52 cardiac cycles; in 1 patient it was 88 cardiac cycles. In all individuals AUCs and in 16 of 18 subjects peak intensity in ROIc and ROId showed a 2- to 10-fold increase compared with ROIa and ROIb. In no examination did AUC ratios show a >2-fold side difference irrespective of the ROI. CONCLUSIONS: The present study demonstrates for the first time that TRsHI produces accurate contrast in different brain areas and represents an ultrasonic tool related to brain perfusion. Absolute values of quantitative parameters show high variations caused by different temporal bone thicknesses and a complex relationship between echo contrast concentrations and measurements of optic intensities. Ratios between different ROIs help to compare contrast enhancement in different brain areas. Furthermore, because of the fact that attenuation of contrast enhancement in TRsHI depends strictly on the insonation depth, harmonic imaging studies of brain perfusion cannot be compared directly with other imaging techniques such as positron emission tomography.

Adult↗

Perfusion versus function: the ischemic cascade in demand ischemia: implications of single-vessel versus multivessel stenosis.

BACKGROUND: We hypothesized that during demand ischemia, abnormal perfusion will precede abnormal function, the spatial extent of perfusion abnormality will be greater than that of functional abnormality, and the spatiotemporal disparity between abnormal perfusion and abnormal function will be more marked in the presence of single-vessel stenosis (SVS) versus multivessel stenosis (MVS). METHODS AND RESULTS: Nine dogs each underwent either SVS or MVS placement. These noncritical stenoses were classified as mild, moderate, or severe on the basis of the transstenotic pressure gradient (10 to 14, 15 to 20, or >20 mm Hg). Dobutamine was infused starting at 10 and reaching 40 microg/kg(-1) x min(-1). Wall thickening (WT) and myocardial perfusion (myocardial contrast echocardiography) were assessed at each stage. Resting perfusion and function were normal in all dogs. In SVS, abnormal perfusion (delayed rate of microbubble replenishment) was seen at the lowest dose of dobutamine irrespective of the stenosis severity, whereas WT abnormality was seen only at high doses of dobutamine and was influenced by the stenosis severity. The spatial extent of abnormal perfusion exceeded that of WT abnormality at all but the highest dobutamine dose. This spatiotemporal discordance between abnormal perfusion and function was significantly less in MVS, where it was possible to identify separate regions with abnormal function at lower doses of dobutamine. CONCLUSIONS: These data support the occurrence of the ischemic cascade during demand ischemia. They also explain the higher sensitivity of abnormal perfusion compared with abnormal function for the detection of coronary stenosis as well as the higher sensitivity of dobutamine echocardiography for MVS compared with SVS.

Animals↗

Local delivery of plasmid DNA into rat carotid artery using ultrasound.

BACKGROUND: Although viral vector systems are efficient to transfect foreign genes into blood vessels, safety issues remain in relation to human gene therapy. In this study, we examined the feasibility of a novel nonviral vector system by using high-frequency, low-intensity ultrasound irradiation for transfection into blood vessels. METHODS AND RESULTS: Luciferase plasmid mixed with or without echo contrast microbubble (Optison) was transfected into cultured human vascular smooth muscle cells (VSMC) and endothelial cells (EC) with the use of ultrasound. Interestingly, luciferase activity was markedly increased in both cell types treated with Optison. We then transfected luciferase plasmid mixed with Optison by means of therapeutic ultrasound into rat artery. Two days after transfection, luciferase activity was significantly higher in carotid artery transfected with luciferase gene with Optison and ultrasound than with plasmid alone. In addition, we transfected an anti-oncogene (p53) plasmid into carotid artery after balloon injury as a model of gene therapy for restenosis. Two weeks after transfection, the intimal-to-medial area ratio in rats transfected with wild-type p53 plasmid complexed with Optison by means of ultrasound was significantly decreased as compared with control, accompanied by a significant increase in p53 protein. No apparent toxicity such as inflammation could be detected in blood vessels transfected with plasmid DNA with ultrasound and Optison. CONCLUSIONS: Overall, we demonstrated that an ultrasound transfection method with Optison enhanced transfection efficiency of naked plasmid DNA into blood vessels without any apparent toxicity. Transfection of p53 plasmid with the use of this method should be useful for safe clinical gene therapy without a viral vector system.

Albumins↗

Quantification of cerebral perfusion with "Real-Time" contrast-enhanced ultrasound.

BACKGROUND: No noninvasive technique is currently capable of "real-time" assessment and monitoring of cerebral blood flow (CBF). We hypothesized that cerebral perfusion could be accurately measured and monitored in "real time" with contrast-enhanced ultrasound (CEU). METHODS AND RESULTS: Cerebral perfusion was assessed in 9 dogs through a craniotomy with CEU at baseline and during hypercapnia and hypocapnia while normoxia was maintained. Cerebral microvascular blood volume (A), microbubble velocity (beta), and blood flow (Axbeta) were calculated from time-versus-acoustic intensity relations. Compared with baseline, hypercapnia and hypocapnia significantly increased and decreased CBF, respectively, as measured by CEU. These changes in blood flow were mediated by changes in both A and beta. A good correlation was found between Axbeta derived from CEU and CBF measured by radiolabeled microspheres (y=0.67x-0.04, r=0.91, P<0.001). CONCLUSIONS: Changes in both cerebral microvascular blood volume and red blood cell velocity can be accurately assessed with CEU. Thus, CEU has the potential for bedside measurement and monitoring of cerebral perfusion in real time in patients with craniotomies or burr holes.

Animals↗

Blood flow estimation with harmonic Flash Echo Imaging.

Blood volume flow estimation remains an important task for the functional evaluation of internal organs. In vitro and in vivo flow estimation has been carried out using Flash Echo Imaging in harmonic mode after the administration of microbubble-based ultrasound contrast agents. The in vitro flow volume rate correlated with the constant replenishment level but less so with the video intensity decay rate. The in vivo volume flow rates obtained in four dogs agreed well with CVI-Q (time domain correlation) based flow measurement. Our experimental results indicate that the volume flow rate can be accurately estimated in vitro and in vivo using harmonic Flash Echo imaging.

Animals↗

Estimate of the maximum absorption rate of microscopic arterial air emboli after entry into the arterial circulation during cardiac surgery.

Some clinicians place patients in the Trendelenburg position during aortic unclamping to decrease the incidence of microscopic cerebral air embolism. Experimental studies have shown that use of the Trendelenburg position does not prevent air emboli from reaching the brain. Nevertheless, the position can decrease the velocity at which bubbles approach the brain, giving more time for nitrogen in the bubbles to be absorbed. We applied a validated mathematical model to estimate that the maximum rate of absorption of microscopic air emboli in blood during and after cardiopulmonary bypass (CPB) equals 1.57 microns/s. This rate is very small, since clinically relevant microbubbles have radii 50-1500 microns, and travel from the aorta to the brain within seconds. The result holds for all usual conditions of CPB. We conclude that absorption does not affect the disposition of air introduced into the arterial circulation. Use of the Trendelenburg position cannot decrease neurologic injury from cerebral air embolism by permitting greater bubble absorption.

Cardiac Surgical Procedures↗

Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography.

Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as spontaneous echocontrast, microbubbles, strands, sutures, vegetations or thrombus. Doppler echocardiographic characteristics of normal and pathologic prosthetic valve function and the management of prosthetic valve pathology is discussed. Physicians taking care of patients with prosthetic valves should be familiar with the characteristics of normal and abnormally functioning prosthetic valves.

Echocardiography, Transesophageal↗

Duplex imaging of the renal arteries with contrast enhancement.

Duplex ultrasound evaluation of the renal arteries is a technically challenging procedure. Its accuracy is significantly influenced by operator expertise and patient factors, such as overlying bowel gas and obesity. Intravenous microbubble contrast agents enhance vascular reflective acoustic signals and may improve ultrasound diagnostic accuracy. The clinical usefulness of such a contrast agent in the renal vasculature was examined prospectively. A total of 22 patients (16 males and 6 females) with mean age of 63 +/-3 years with suspected abdominal vascular disease were studied prospectively. A complete color flow duplex imaging study of the renal vasculature was performed. This was then followed by an identical examination during which an ultrasound contrast agent (Definity, DuPont Pharmaceutical) was infused intravenously at a rate of 2 to 4 mL/min. In addition to imaging of the vessels, the peak systolic velocity and Doppler waveforms of the aorta and renal arteries were examined. These results were independently compared to results with contrast angiography. A mean of 67 mL of contrast was used per patient. Of the total of 43 renal arteries examined, the accuracy for the detection of occlusions was 75% (3 of 4) for both standard and contrast-enhanced duplex ultrasound. The accuracy for the detection of hemodynamically significant stenosis was 50% (6 of 12) for standard and 75% (9 of 12) for contrast-enhanced duplex ultrasound. Visualization of normal or minimally diseased arteries was 94% (30 of 32) for standard and 97% (31 of 32) for contrast-enhanced ultrasound. Although overall accuracy was not enhanced by the infusion of ultrasound contrast, 5 of 7 arteries not visualized by color flow duplex were detected following the infusion of contrast agent, resulting in an additional 10% (5 of 48) of vessels visualized. Peak systolic velocities were increased by an average of 10% in normal or minimally diseased vessels and 12% in stenotic vessels following contrast administration but these differences were not statistically significant. Contrast-enhanced duplex imaging of the renal arteries is safe but not routinely required when performed by an experienced sonographer. However, it may increase visualization and accuracy in patients with stenoses or when the vessels are not initially visualized. Although increased velocities are seen when contrast agent is used, this does not appear to necessitate different Doppler criteria at this time.

Adult↗

Quantification of resting myocardial blood flow velocity in normal humans using real-time contrast echocardiography. A feasibility study.

BACKGROUND: Real-time myocardial contrast echocardiography (MCE) is a novel method for assessing myocardial perfusion. The aim of this study was to evaluate the feasibility of a very low-power real-time MCE for quantification of regional resting myocardial blood flow (MBF) velocity in normal human myocardium. METHODS: Twenty study subjects with normal left ventricular (LV) wall motion and normal coronary arteries, underwent low-power real-time MCE based on color-coded pulse inversion Doppler. Standard apical LV views were acquired during constant IV. infusion of SonoVue. Following transient microbubble destruction, the contrast replenishment rate (beta), reflecting MBF velocity, was derived by plotting signal intensity vs. time and fitting data to the exponential function; y (t) =A (1-e(-beta(t-t0))) + C. RESULTS: Quantification was feasible in 82%, 49% and 63% of four-chamber, two-chamber and apical long-axis view segments, respectively. The LAD (left anterior descending artery) and RCA (right coronary artery) territories could potentially be evaluated in most, but contrast detection in the LCx (left circumflex artery) bed was poor. Depending on localisation and which frames to be analysed, mean values of beta were 0.21-0.69 s(-1), with higher values in medial than lateral, and in basal compared to apical regions of scan plane (p = 0.03 and p < 0.01). Higher beta-values were obtained from end-diastole than end-systole (p < 0.001), values from all-frames analysis lying between. CONCLUSION: Low-power real-time MCE did have the potential to give contrast enhancement for quantification of resting regional MBF velocity. However, the technique is difficult and subjected to several limitations. Significant variability in beta suggests that this parameter is best suited for with-in patient changes, comparing values of stress studies to baseline.

Adult↗

Neurological and neuropsychological examination and outcome after use of an intra-aortic filter device during cardiac surgery.

Cerebral embolization of particles after cardiac surgery is frequently associated with neurological deficits. Aortic crossclamp manipulation seems to be the most significant cause of emboli release during cardiac surgery. The goal of this study was to demonstrate whether the use of an intra-aortic filter device has an effect on the magnet resonance imaging (MRI) and functional neurological outcome. Twenty-four patients undergoing cardiosurgical procedures using cardiopulmonary bypass (CPB) were selected: coronary artery bypass graft (CABG) surgery (n = 17), aortic valve replacement (AVR) surgery (n = 4) or combined procedures (n = 3). Patients were evaluated by diffusion weighted MRI of the brain, neurological examination and neuropsychological assessment regarding alertness as well as divided and selective attention before and five to seven days after surgery. The patients were divided into two groups. In group I, 12 patients received a filter through a modified 24 F arterial cannula immediately before the aortic crossclamp was released. Filters remained in the aorta until CPB was discontinued. Intraoperatively, bilateral middle cerebral artery transcranial Doppler (TCD) was monitored at baseline, at the beginning of CPB, at a timepoint when the aorta was crossclamped, when the filter was inserted and while the crossclamp was switched to partial clamping until the CPB was discontinued. TCD was used for detection of microembolic signals (MES). The captured material in the filter was examined histologically. Twelve patients served as controls without aortic filtration (group II). The MRI of the brain did not show any diffusion alterations in either group before or after surgery. No patient developed a focal neurological deficit or stroke. Intraoperative quantitative MES detection revealed a four to tenfold increase in patients of group I compared with group II (5-6 versus 0.5-1 MES/min) during the filter dwell time. There was no consistent pattern regarding the neurobehavioural sequelae. Filters showed arteriosclerotic debris in 75% of the patients. The use of the intra-aortic filter device did not show a positive effect on neurological, neuroradiographical and neuropsychological outcomes. The increase of the MES rate in group I patients may be due to microbubbles generated as microcavitations by the filter or the aortic filter cannula. The intra-aortic filter was able to capture atheromatous material in 75% of the patients.

Aorta, Thoracic↗

Microgravity experiments on boiling and applications: research activity of advanced high heat flux cooling technology for electronic devices in Japan.

Research and development on advanced high heat flux cooling technology for electronic devices has been carried out as the Project of Fundamental Technology Development for Energy Conservation, promoted by the New Energy and Industrial Technology Development Organization of Japan (NEDO). Based on the microgravity experiments on boiling heat transfer, the following useful results have obtained for the cooling of electronic devices. In subcooled flow boiling in a small channel, heat flux increases considerably more than the ordinary critical heat flux with microbubble emission in transition boiling, and dry out of the heating surface is disturbed. Successful enhancement of heat transfer is achieved by a capillary effect from grooved surface dual subchannels on the liquid supply. The critical heat flux increases 30-40 percent more than for ordinary subchannels. A self-wetting mechanism has been proposed, following investigation of bubble behavior in pool boiling of binary mixtures under microgravity. Ideas and a new concept have been proposed for the design of future cooling system in power electronics.

Cold Temperature↗

Spontaneous breathing or mechanical ventilation alters lung compliance and tissue association of exogenous surfactant in preterm newborn rabbits.

In preterm infants with respiratory distress syndrome, surfactant administration followed by immediate extubation to spontaneous breathing with nasal continuous positive airway pressure reduces the need for mechanical ventilation. With this treatment approach, repeated doses of surfactant are rarely indicated. We used a rabbit model to test the hypothesis that exogenous surfactant therapy followed by spontaneous breathing results in a more sustained initial treatment response compared with treatment followed by mechanical ventilation. Preterm rabbits (gestational age 28.5 d) were treated with pharyngeal deposition of 200 mg/kg radiolabeled surfactant (14C-Curosurf) and randomized to 4 h of spontaneous breathing or mechanical ventilation or to a control group, killed immediately after surfactant administration. With pharyngeal deposition, 46 +/- 10% (mean +/- SEM) of the administered surfactant reached the lungs. The dynamic lung-thorax compliance was higher in spontaneously breathing compared with mechanically ventilated animals (median, 9.9 and 0.75 ml x cm H2O(-1) x kg(-1), respectively; p < 0.05). The relative distribution of 14C-Curosurf in bronchoalveolar lavage fluid and homogenized lung tissue showed a higher degree of tissue association in the spontaneously breathing animals [53 +/- 4 versus 26 +/- 3% (mean +/- SEM)] than in mechanically ventilated animals (p < 0.01), the latter figure being very similar to that of the control group (25 +/- 5%). There was a higher degree of lipid peroxidation and fewer microbubbles in bronchoalveolar lavage fluid from mechanically ventilated animals. We conclude that the initial lung tissue association of exogenous surfactant is impaired by mechanical ventilation. This is associated with a reduction of dynamic compliance and evidence of increased surfactant inactivation.

Animals↗

Prognosis after stroke followed by surgical closure of patent foramen ovale: a prospective follow-up study with brain MRI and simultaneous transesophageal and transcranial Doppler ultrasound.

BACKGROUND: The risk of stroke and the long-term prognosis of recurrent strokes in young patients with patent foramen ovale (PFO) are not well known. For this reason, the treatment of these patients remains empirical. An alternative treatment to prolonged antithrombotic therapy may be surgical closure of the PFO. METHODS: Thirty patients (20 men and 10 women) with stroke and PFO were prospectively selected among 138 patients with stroke and PFO for a study of surgical closure of PFO at our center. Eligible patients were < 60 years old, had negative results of a systematic search for another cause of stroke (first criterion), and met two of the four following criteria: (1) recurrent clinical cerebrovascular events or multiple ischemic lesions on brain MR, (2) PFO associated with an atrial septal aneurysm, (3) > 50 microbubbles counted in the left atrium on contrast transesophageal echocardiography (TEE), and (4) Valsalva maneuver or cough preceding the stroke. Patients selected in this manner for surgery were considered to be a subgroup with a higher risk of stroke recurrence. RESULTS: All patients had a direct suture of PFO while under cardiopulmonary bypass without recorded early or delayed significant complication. All patients underwent a new brain MRI and TEE simultaneous with transcranial Doppler ultrasonography after contrast injection at 8 +/- 3 months after surgery. After a mean follow-up of 2 years without antithrombotic treatment, no recurrent cerebrovascular event (stroke or transient ischemic attack [TIA]) and no new lesion on MRI had developed. Postoperative contrast TEE and transcranial Doppler ultrasonography showed that two patients had residual interatrial right-to-left shunting, although much smaller than before surgery, associated with single versus double continuous suture. CONCLUSIONS: Our study of 30 selected stroke patients with surgical suture of PFO showed a stroke recurrence rate of 0% and no significant complication. Residual right-to-left shunting may be avoided by double continuous suture of the PFO. In the absence of controlled studies to guide individual therapeutic decisions, our findings show that PFO closure can be done safely and may be considered to avoid recurrence in selected patients with long life expectancy and presumed paradoxic embolism.

Adult↗

Assessment of renal blood flow with contrast ultrasonography.

Sonicated albumin microspheres, a digitalizing ultrasound system, and a mathematical model for flow were used to determine whether blood flow in the canine kidney could be assessed with contrast ultrasound. Albunex ultrasound contrast microspheres were injected into the aorta while ultrasound images of the kidney and aorta were recorded simultaneously. Ultrasound data were obtained during contrast injections at 93 different renal blood flow rates in nine dogs. Contrast dose was calibrated to ultrasound system response for both aortic and renal images. A linear relationship between microbubble concentration used and pixel intensity was established (r = 0.89 for aortic images and r = 0.91 for renal images). Renal blood flow was manipulated from baseline by means of a hydraulic renal artery occluder and by intravenous dopamine or fenoldopam infusion. Blood flow calculated with contrast ultrasonography was compared with direct measurement obtained with an electromagnetic flow probe at each flow rate. Direct measurement correlated with rates calculated with contrast ultrasonography (r = 0.84, 95% confidence limits from 0.75 to 0.90). Overall, calculations tended to overestimate absolute flow measurements, and overestimation of flow tended to be greater during pharmacologically manipulated flow rates. We conclude the changes and trends in renal blood flow can be serially assessed in vivo with contrast ultrasonography, but technical limitations of present commercial ultrasounds systems preclude absolute quantification at this time.

Albumins↗

Segmental wall motion abnormalities in patients undergoing total hip replacement: correlations with intraoperative events.

We examined the effect of methylmethacrylate cement on venous embolization and cardiac function in 20 patients having total hip arthroplasty under general anesthesia. Segmental wall motion abnormalities and intracardiac targets (presumably emboli) were investigated by making videotaped recordings of the transgastric short axis and longitudinal 4-chamber views of the heart with transesophageal echocardiography at different points during surgery. The incidence of segmental wall motion abnormalities was the most frequent during insertion of cemented femoral prostheses (8 of 14 patients had wall motion abnormalities). This was significantly different from baseline measurements taken at the beginning of surgery (P < 0.05). In addition, there were also significantly more segmental wall motion abnormalities in patients having a cemented femoral component compared to those having an uncemented femoral prosthesis (P < 0.05). The incidence of wall motion abnormalities during acetabular and femoral reaming and during wound closure was not significantly different from baseline. Intracardiac targets (emboli) were seen in all 20 patients during surgery. The largest number of emboli occurred during reaming of the femur and during insertion of the femoral prosthesis. Significantly more emboli were seen with cemented components (P < 0.02). Most emboli were small (< 2 mm) and appeared similar to the microbubbles produced by agitating saline with a small amount of air. Six patients also had larger (> 5 mm) emboli that appeared to be solid material. One patent foramen ovale was detected (5% incidence). There were no adverse cardiac or neurologic events, and heart rate and arterial blood pressure remained within normal limits throughout surgery.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗