PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87Linked to original sources

Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode.

A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5mM), a short response time (within 5s), a large current density (1.176 mA cm(-2)), and high sensitivity (91mA M(-1)cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated.

Aspergillus niger↗

Resonant mirror biosensor detection method based on yessotoxin-phosphodiesterase interactions.

Yessotoxin (YTX) is a generic name for a group of lipophilic compounds recently discovered and chemically characterized. Association measurements were done in a resonant mirror biosensor. The instrument detects changes in the refractive index and/or thickness occurring within a few hundred nanometers form the sensor surface where a molecule is attached. We used aminosilane surfaces where phosphodiesterase 3',5'-cyclic-nucleotide-specific from bovine brain (PDEs) was immobilized. Over this immobilized ligand different amounts of YTX were added and typical association curve profiles were observed. These association curves fit a pseudo-first-order kinetic equation where the apparent association rate constant (k(on)) can be calculated. The value of this constant increases with YTX concentration. From the representation of k(on) versus YTX concentration we obtained the association rate constant (k(ass)) 248+/-40 M(-1)s(-1) and the dissociation rate constant (k(diss)) 9.36 x 10(-4)+/-1.72 x 10(-4)s(-1). From these values the kinetic equilibrium dissociation constant (K(D)) for YTX-PDEs association can be calculated. The value of this last constant is 3.74 x 10(-6)+/-8.25 x 10(-8)M YTX. The PDE-YTX association was used as a method suitable for determination of the toxin concentration in a shellfish sample. The assay had sufficient sensitivity and can be used on simple shellfish extracts.

3',5'-Cyclic-AMP Phosphodiesterases↗

Interpretation of the temperature dependence of rate constants in biosensor studies.

A comparison is made between Arrhenius and transition-state analyses of the temperature dependence of rate constants reported in four published biosensor studies. Although the Eyring transition-state theory seemingly affords a more definitive solution to the problem of characterizing the activation energetics, the analysis is equivocal because of inherent assumptions about reaction mechanism and the magnitude of the transmission coefficient. In view of those uncertainties it is suggested that a preferable course of action entails reversion to the empirical Arrhenius analysis with regard to the energy of activation and a preexponential factor. The former is essentially equivalent to the enthalpy of activation, whereas the magnitude of the latter indicates directly the extent of disparity between the frequency of product formation and the universal frequency factor (temperature multiplied by the ratio of the Boltzmann and Planck constants) and hence the likelihood of a more complicated kinetic mechanism than that encompassed by the Eyring transition-state theory.

Biosensing Techniques↗

Preparation of novel mercury-doped silver nanoparticles film glassy carbon electrode and its application for electrochemical biosensor.

A novel mercury-doped silver nanoparticles film glassy carbon (Ag/MFGC) electrode was prepared in this study. Electrochemical behaviors of cysteine on the Ag/MFGC electrode were investigated by electrochemical impedance spectroscopy and cyclic voltammetry (CV). The results indicated that cysteine could be strongly adsorbed on the surface of the Ag/MFGC electrode to form a thin layer. The doped electrode could catalyze the electrode reaction process of cysteine, and the cysteine displayed a pair of well-defined and nearly reversible CV peaks at the electrode in an acetate buffer solution (pH 5.0). The Ag/MFGC electrode was used for determination of cysteine by differential pulse voltammetry. The linear range was between 4.0x10(-7) and 1.3x10(-5) mol/L, with a detection limit of 1.0x10(-7) mol/L and a signal-to-noise ratio of 3. The relative standard deviation was 2.4% for seven successive determinations of 1.0x10(-5) mol/L cysteine. The determinations of cysteine in synthetic samples and urinal samples were carried out and satisfactory results were obtained. Amperometric application of the Ag/MFGC electrode as biosensors is proposed.

Adsorption↗

Kinetic studies of small molecule interactions with protein kinases using biosensor technology.

Protein kinases are among the most commonly targeted groups of molecules in drug discovery today. Despite this, there are few examples of using surface plasmon resonance (SPR) for kinase inhibitor interaction studies, probably reflecting the need for better developed assays for these proteins. In this article, we present a general methodology that uses biosensor technology to study small molecule binding to eight different serine/threonine and tyrosine kinases. Mild immobilization conditions and a carefully composed assay buffer were identified as key success factors. The methodology package consists of direct binding studies of compounds to immobilized kinases, kinase activity assays to confirm inhibitory effects, detailed kinetic analyses of inhibitor binding, and competition assays with ATP for identification of competitive inhibitors. The kinetic assays resolve affinity into the rates of inhibitor binding and dissociation. Therefore, more detailed information on the relation between inhibitor structure and function is obtained. This might be of key importance for the development of effective kinase inhibitors.

Binding Sites↗

A surface modification strategy on silicon nitride for developing biosensors.

A surface modification strategy for the use of giant magnetoresistive materials in the detection of protein-protein interactions is developed. This modification strategy is based on silanization of semiconductive materials. A native silicon nitride surface was treated with concentrated hydrofluoric acid to improve surface homogeneity. Nano-strip was used to oxidize silicon nitride to form a hydrophilic layer. Aminopropyltriethoxysilane was subsequently used to functionalize the treated surfaces to form amine groups, which were further activated with glutaraldehyde to introduce a layer of aldehyde groups. The effectiveness of this modification strategy was validated by chemiluminescence immunoassays of purified 6x His-HrpW of Pseudomonas syringae pv. tomato DC3000 and human transferrin. Signals with intensities related to concentrations of these two immobilized model proteins were observed. The modified surface was also validated by a more complex system: intercellular proteins secreted by DC3000. HrpW in these protein mixtures was successfully recognized by anti-HrpW antibodies when mixed proteins were immobilized onto activated surfaces. This surface modification strategy provides a platform onto which proteins can be directly immobilized for biosensor and protein array applications.

Biosensing Techniques↗

DNA biosensor based on chitosan film doped with carbon nanotubes.

A biosensor based on chitosan doped with carbon nanotube (CNT) was fabricated to detect salmon sperm DNA. Methylene blue (MB) was employed as a DNA indicator. It was found that CNTs can enhance the electroactive surface area threefold (0.28 +/- 0.03 and 0.093 +/- 0.06 cm(2) for chitosan-CNT- and chitosan-modified electrodes, respectively) and can accelerate the rate of electron transfer between the redox-active MB and the electrode. A low detection limit of 0.252 nM fish sperm DNA was achieved, and no interference was found in the presence of 5 microg/ml human serum albumin. The differential pulse voltammetry signal of MB was linear over the fish sperm DNA concentration range of 0.5-20 nM.

Animals↗

Analyzing a kinetic titration series using affinity biosensors.

The classical method of measuring binding constants with affinity-based biosensors involves testing several analyte concentrations over the same ligand surface and regenerating the surface between binding cycles. Here we describe an alternative approach to collecting kinetic binding data, which we call "kinetic titration." This method involves sequentially injecting an analyte concentration series without any regeneration steps. Through a combination of simulation and experimentation, we show that this method can be as robust as the classical method of analysis. In addition, kinetic titrations can be more efficient than the conventional data collection method and allow us to fully characterize analyte binding to ligand surfaces that are difficult to regenerate.

Antibodies, Monoclonal↗

Electrochemical DNA biosensor for the study of ciprofloxacin-DNA interaction.

The interaction of ciprofloxacin with DNA was studied by using an electrochemical DNA biosensor. The binding mechanism of ciprofloxacin was elucidated by using constant current potentiometry and differential pulse voltammetry at DNA-modified glassy carbon electrode. The decrease in the guanine oxidation peak area or peak current at +0.9 V was used as an indicator for the interaction mechanism in 0.2M acetate buffer (pH 5). The binding constant (K) values obtained were 1.33+/-0.02 x 10(4) and 1.32+/-0.08 x 10(4) M(-1) with constant current potentiometry and differential pulse voltammetry, respectively. A linear dependence of the guanine peak area or peak currents was observed in the range of 40-80 microM ciprofloxacin, with a detection limit of 24 microM with r=0.995 and 9 microM with r=0.999 by using constant current potentiometry and differential pulse voltammetry, respectively. Moreover, the influence of sodium and calcium ions was also studied to elucidate the mechanism of ciprofloxacin-DNA interaction at different solution conditions, and this proved to be helpful in understanding the ciprofloxacin-DNA interaction.

Anti-Bacterial Agents↗

Kinetic analysis of enzymatic hydrolysis of crystalline cellulose by cellobiohydrolase using an amperometric biosensor.

An amperometric biosensor for the detection of cellobiose has been introduced to study the kinetics of enzymatic hydrolysis of crystalline cellulose by cellobiohydrolase. By use of a sensor in which pyrroloquinoline quinone-dependent glucose dehydrogenase was immobilized on the surface of electrode, direct and continuous observation of the hydrolysis can be achieved even in a thick cellulose suspension. The steady-state rate of the hydrolysis increased with increasing concentrations of the enzyme to approach a saturation value and was proportional to the amount of the substrate. The experimental results can be explained well by the rate equations derived from a three-step mechanism consisting of the adsorption of the free enzyme onto the surface of the substrate, the reaction of the adsorbed enzyme with the substrate, and the liberation of the product. The catalytic constant of the adsorbed enzyme was determined to be 0.044+/-0.011s(-1).

Biosensing Techniques↗

Proapoptotic BCL-2 family members and mitochondrial dysfunction during ischemia/reperfusion injury, a study employing cardiac HL-1 cells and GFP biosensors.

The objective of this study was to evaluate mitochondrial alterations in a cell-based model of myocardial ischemia/reperfusion (I/R) injury. Using GFP-biosensors and fluorescence deconvolution microscopy, we investigated mitochondrial morphology in relation to Bax and Bid activation in the HL-1 cardiac cell line. Mitochondria underwent extensive fragmentation during ischemia. Bax translocation from cytosol to mitochondria was initiated during ischemia and proceeded during reperfusion. However, Bax translocation was not sufficient to induce cell death or mitochondrial dysfunction. Bid processing was caspase-8 dependent, and Bid translocation to mitochondria occurred after Bax translocation and clustering, and minutes before cell death. Clustering of Bax into distinct regions on mitochondria could be prevented by CsA, an inhibitor of the mitochondrial permeability transition pore, and also by SB203580, an inhibitor of p38 MAPK. Surprisingly, mitochondrial fragmentation which occurred during ischemia and before Bax translocation could be reversed by the addition of the p38 inhibitor SB203580 at reperfusion. Taken together, these results implicate p38 MAPK in the mitochondrial remodeling response to I/R that facilitates Bax recruitment to mitochondria.

Apoptosis↗

A novel fluorescent method employing the FRET-based biosensor "LIBRA" for the identification of ligands of the inositol 1,4,5-trisphosphate receptors.

LIBRA is a fluorescent biosensor of inositol 1,4,5-trisphosphate (IP(3)) and is composed of the ligand-binding domain of the rat type 3 IP(3) receptor and cyan and yellow fluorescent proteins. We examined the responses of LIBRA and its IP(3)-insensitive mutant LIBRA-N to compounds known to inhibit IP(3)-induced Ca(2+) release. Heparin, a competitive antagonist of IP(3) receptors, increased the emission ratio of LIBRA but not that of LIBRA-N. In contrast, 2-aminoethoxydiphenyl borate, a known non-competitive inhibitor of IP(3) receptor, decreased the emission ratios of both LIBRA and LIBRA-N. Thus, the concurrent use of LIBRA-N with LIBRA identifies nonspecific responses. These results indicate that LIBRA and its mutant control can be used to detect specific agonists and antagonists of IP(3) receptors. We also demonstrate the utility of LIBRA and LIBRA-N in discriminating between specific and nonspecific responses in intact cells.

Biosensing Techniques↗

Cellular functions of cholesterol probed with optical biosensors.

Cholesterol is an essential constituent of cell membranes and the regulation of cholesterol concentration is critical for cell functions including signaling. In this paper, we applied resonant waveguide grating (RWG) biosensor to study the cellular functions of cholesterol through real time monitoring the dynamic mass redistribution (DMR) mediated by cholesterol depletion with methyl-beta-cyclodextrin (mbetaCD). In A431 cells, depletion of cholesterol by mbetaCD led to a DMR signature that was similar, but not identical to that induced by epidermal growth factor (EGF). To elucidate the cellular mechanisms of the DMR signal mediated by cholesterol depletion, a panel of modulators that specifically modulate the activities of various cellular targets were used to pretreat the cells. Results showed that the DMR signals triggered by cholesterol depletion are primarily linked to the transactivation of EGF receptor. Multiple signaling pathways including Ras/mitogenic activated protein (MAP) kinase, protein kinase C (PKC) and phosphatidylinositol 3-kinase (PI3K) acted synergically in the cell response, whereas the activation of protein kinase A (PKA) pathway was found to antagonize the cell response.

Biosensing Techniques↗

Biosensors of protein kinase action: from in vitro assays to living cells.

Protein kinases, and the signal transduction pathways in which they participate, are now recognized to be medicinally attractive targets of opportunity. Inhibitors of the protein kinase family not only hold great promise as therapeutic agents, but are also of profound utility in the characterization of signaling pathways. The direct visualization of protein kinase activity in living cells provides a genuine assessment of the efficacy and selectivity of these inhibitors in a physiological setting. In addition, the ability to visualize the activity of a protein kinase in real time furnishes a direct measurement of the activation of specific signaling pathways in response to extracellular stimuli. We have developed two series of fluorescent substrates for protein kinase C (PKC) using a strategy that positions the reporter-group directly on the residue undergoing phosphorylation. The first series of PKC substrates is based, in part, on the Ca(+2) indicators developed by Tsien and his collaborators during the 1980s. In this case, phosphorylation of the substrate creates a divalent metal ion binding site. Upon metal ion coordination, a fluorescence change transpires via a mechanism analogous to that described for the Ca(+2) indicators. The second series of PKC sensors was identified via the preparation and subsequent screen of a library of fluorescently-labeled PKC peptide substrates. The lead derivative displays a phosphorylation-induced fluorescence change that allows the visualization of real-time PKC activity in both cell lysates and living cells. Furthermore, immunodepletion experiments demonstrate that the fluorescently-tagged peptide is selectively, if not exclusively, phosphorylated by the conventional PKCs. Both of the protein kinase biosensor strategies take advantage of the ease with which peptides can be modified to create libraries of structurally altered analogs. However, the inherent synthetic mutability of peptides is not just limited to library construction. For example, it may ultimately be possible to simultaneously monitor multiple protein kinases by affixing fluorophores with distinct photophysical properties to appropriately designed active site-directed peptides.

Amino Acid Sequence↗

Atomic force microscopy characterization of an electrochemical DNA-biosensor.

Electrode surface characteristics represent an important aspect on the construction of sensitive DNA electrochemical biosensors for rapid detection of DNA interaction and damage. Two different immobilization procedures of double-stranded DNA (dsDNA) at the surface of a HOPG electrode were evaluated by MAC mode AFM performed in air. A thin dsDNA adsorbed film forming a network structure with holes exposing the electrode surface and a thick dsDNA film completely covering the electrode surface, presenting a much rougher structure, were investigated. The DNA surface characteristics and structure are discussed with respect to the degree of surface coverage.

Adsorption↗

Amperometric biosensor based on denatured DNA for the study of heavy metals complexing with DNA and their determination in biological, water and food samples.

Amperometric biosensor (BS) has been elaborated based on the stationary mercury-film electrode (SMFE) with silver support and cellulose nitrate (CN) membrane containing immobilized single-stranded DNA (ssIDNA). The sorption isotherms and ssDNA-heavy metal binding constants have been obtained with the BS. According to these data, the chosen heavy metals form the following series of binding strength with ssIDNA: Pb(II)>Fe(III)>Cd(II). It has been found that upon the competitive adsorption, there exists practically simultaneous sorption of different ions at ssIDNA containing membrane. The method of the determination of heavy metals based on preconcentration of metal ions on the BS followed by the destruction of DNA-metal complexes with ethylenediamine tetraacetate (EDTA) and voltammogram recording has been proposed. The lower limits of detectable contents are 1.0x10(-10), 1.0x10(-9) and 1.0x10(-7) mol l(-1) for Pb(II), Cd(II) and Fe(III), respectively. Heavy metals have been assayed in natural and drinking water, milk and blood serum samples even under simultaneous presence with a selectivity factor of 1:10. The effect of matrix components has been estimated.

Animals↗

Application of integrated SECM ultra-micro-electrode and AFM force probe to biosensor surfaces.

The integration of scanning electrochemical ultra-micro-electrode (UME) with atomic force microscope cantilever probe have been achieved by using a homemade photolithography system. A gold-film-coated AFM cantilever was insulated with photo resist coating and a pointed end of the AFM probe was opened by illuminating with maskless arbitrary optical micro-pattern generator. To realize precise control of probe sample distance constantly, the resulting scanning electrochemical microscopy (SECM)-AFM probe was operated using a dynamic force microscopy (DFM) technique with magnetic field excitation. From a steady-state voltammetric experiment, the effective electrode diameters of the probes thus prepared were estimated to be from 0.050 to 6.2 microm. The capability of this SECM-AFM probe have been tested using gold comb in the presence of Fe(CN)(6)(3-). The simultaneous imaging of the topography and electrochemical activity of the strip electrode was successfully obtained. We also used the SECM-AFM to examine in situ topography and enzymatic activity measurement. Comparison of topography and oxidation current profiles above enzyme-modified electrode showed active parts distribution of biosensor surface.

Biosensing Techniques↗

Kinetic study of the degradation of a potential local anesthetic drug in serum using the DNA-based electrochemical biosensor.

DNA-drug association interaction at the DNA modified screen-printed electrode for 1-methyl-2-piperidinoethylester of 2-hexoxyphenylcarbamic acid was found leading to an accumulation of the drug within the DNA layer. A procedure for the determination of drug in blood serum matrix using the protein precipitation and voltammetric measurement of the electroactive drug with the DNA biosensor was obtained and an effort was done to apply it for an assay of the drug enzymatic degradation in human and rabbit sera at 37 degrees C.

Anesthetics, Local↗