PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biodegradation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Elastic biodegradable poly(glycolide-co-caprolactone) scaffold for tissue engineering.

Cyclic mechanical strain has been demonstrated to enhance the development and function of engineered smooth muscle (SM) tissues, and it would be necessary for the development of the elastic scaffolds if one wishes to engineer SM tissues under cyclic mechanical loading. This study reports on the development of an elastic scaffold fabricated from a biodegradable polymer. Biodegradable poly(glycolide-co-caprolactone) (PGCL) copolymer was synthesized from glycolide and epsilon-caprolactone in the presence of stannous octoate as catalyst. The copolymer was characterized by (1)H-NMR, gel permeation chromatography and differential scanning calorimetry. Scaffolds for tissue engineering applications were fabricated from PGCL copolymer using the solvent-casting and particle-leaching technique. The PGCL scaffolds produced in this fashion had open pore structures (average pore size = 250 microm) without the usual nonporous skin layer on external surfaces. Mechanical testing revealed that PGCL scaffolds were far more elastic than poly(lactic-co-glycolic acid) (PLGA) scaffolds fabricated using the same method. Tensile mechanical tests indicated that PGCL scaffolds could withstand an extension of 250% without cracking, which was much higher than withstood by PLGA scaffolds (10-15%). In addition, PGCL scaffolds achieved recoveries exceeding 96% at applied extensions of up to 230%, whereas PLGA scaffolds failed (cracked) at an applied strain of 20%. Dynamic mechanical tests showed that the permanent deformation of the PGCL scaffolds in a dry condition produced was less than 4% of the applied strain, when an elongation of 20% at a frequency of 1 Hz (1 cycle per second) was applied for 6 days. Moreover, PGCL scaffolds in a buffer solution also had permanent deformations less than 5% of the applied strain when an elongation of 10% at a frequency of 1 Hz was applied for 2 days. The usefulness of the PGCL scaffolds was demonstrated by engineering SM tissues in vivo. This study shows that the elastic PGCL scaffolds produced in this study could be used to engineer SM-containing tissues (e.g. blood vessels and bladders) in mechanically dynamic environments.

Absorbable Implants↗

Tailored delivery of active keratinocyte growth factor from biodegradable polymer formulations.

We report the results of a high throughput screening campaign that is aimed to develop a biodegradable polymer-based formulation to deliver active keratinocyte growth factor (KGF) and provide a means to tune the KGF delivery rate. A statistical design strategy was used to prepare and screen a series of polymer blends that were composed of poly(lactic acid) (PLA), poly(glycolic acid) (PGA), and the surfactant sodium bis(ethylhexyl)sulfosuccinate (Aerosol-OT, AOT). Chloroform was the solvent. Our high throughput screening method used a two-tiered assessment strategy. At Level 1, we identified "lead" KFG-loaded formulations that exhibited KGF emission spectra that were the most similar to the native KGF spectrum recorded in buffer. At Level 2, we used steady-state emission and a homogeneous polarization immunoassay strategy to determine the concentration of total and active KGF, respectively, liberated from the lead formulations during biodegradation. After preparing and screening 2500 formulations, we identified several viable, lead formulations. An analysis of the data showed that the combination of PLA, PGA, and AOT were important to yield a high fraction of active KGF upon release from the formulation; no combination of any two together produced an effect as good as the ternary formulation. The optimum formulations that yielded the highest fraction of active KGF upon release had the following general features: PLA/PGA (w/w) near unity, AOT loading of 100-200 mM, water/AOT mole ratio of 10-20, and a pH between 6 and 8. PLA alone cast from chloroform delivered KGF, but that KGF did not bind to anti-KGF antibodies (i.e., it was inactive). We can tune the KGF release kinetics by more than two orders of magnitude while maintaining the KGF activity upon liberation from the formulation by adjusting the PLA molecular weight.

Biocompatible Materials↗

The influence of resin chemistry on a dental composite's biodegradation.

Previous work reported that commercial dental composite resins containing a urethane-modified bisGMA (bisphenylglycidyl dimethacrylate)/TEGDMA (triethylene glycol dimethacrylate) (ubis) based monomer system showed a 10-fold reduction in the release of a bisGMA-derived product, bishydroxypropoxyphenyl propane (bisHPPP), as compared with that found for bisGMA/TEGDMA (bis) based composites after incubation with cholesterol esterase (CE). Unfortunately, these materials also differed substantially in filler type and content, making it impossible to directly relate any specific parameter to the differences in biodegradation levels. By controlling for filler content and type, the current study will seek to probe the biomolecular interactions between composite resin chemistry and esterase activity in order to help explain the observed differences in biodegradation levels between the ubis and bis resin systems. After 32 days of incubation, buffer and CE solutions were analyzed for degradation products using high-performance liquid chromatography, UV spectroscopy, and mass spectrometry. Both materials were characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, and X-ray photoelectron spectroscopy. In the CE groups, the ubis system showed a 2.6- to 86-fold reduction (dependent on the product) in the amount of isolated products relative to the bis system (p < 0.01). Scanning electron microscopy data also demonstrated the relative stability of the ubis system and X-ray photoelectron spectroscopy analysis showed a higher content of the ester bond at the surface of the bis samples. Fourier transform infrared data showed that both resins had similar conversions. Because both systems were identical except for their monomer systems, it was concluded that changes in biostability were associated with chemistry. Crosslinking, hydrophobicity, and solubility all relate to ubis's pro-stability.

Acrylic Resins↗

Long-term regeneration of the rat sciatic nerve through a biodegradable poly(DL-lactide-epsilon-caprolactone) nerve guide: tissue reactions with focus on collagen III/IV reformation.

Long-term studies on nerve-guide regeneration are scarce. Therefore, in rats, long-term (16 months) sciatic nerve regeneration through poly(DL-lactide-epsilon-caprolactone) [poly(DLLA-epsilon-CL)] nerve guides was studied and compared with the nonoperated control side. Poly(DLLA-epsilon-CL) degradation and possible long-term foreign body reaction against poly(DLLA-epsilon-CL) nerve guides, as well as the distribution of both collagen type III and IV were studied. In vivo poly(DLLA-epsilon-CL) studies have been performed before but not for such long time points; also, a detailed analysis of collagen III/IV has not been presented before. The results demonstrate that biodegradable poly(DLLA-epsilon-CL) nerve guides yield good nerve regeneration and collagen III/IV deposition relative to the anatomy of the control side. Regenerated nerve showed almost similar collagen type III/IV distribution patterns as compared with the nonoperated control side, although the delineation of matrix was clearer in the control side. The relative amount of collagen III and IV immunostaining in nerve cross-sections did not, however, differ between the control nerve tissue and the operated side after 16 months. After 16 months of implantation, however, some very small fragments of biomaterial could still be found on the edge of the epineurium of the regenerated nerve, indicating remnants of a secondary foreign body reaction. The biomaterial fragments and foreign body reaction did not influence the nerve regeneration process after 16 months. Biodegradable poly(DLLA-epsilon-CL) nerve guides are useful for long-term bridging of short peripheral nerve gaps.

Animals↗

Biocompatibility and biodegradation of a bone composite containing tricalcium phosphate and genipin crosslinked gelatin.

A biodegradable composite (GGT) containing tricalcium phosphate ceramic particles and genipin crosslinked gelatin was developed for use as a bone substitute. The objective of this study was to assess the biocompatibility and the osteoconductivity of the GGT composite on new bone formation in vitro. Additionally, biodegradation and biocompatibility of the GGT composite in animals were investigated. Results of the GGT composites cocultured with osteoblasts showed that the concentration of genipin used as a crosslinking agent should be <0.5 wt % to avoid cytotoxicity. For in vivo degradation studies, we found that when the concentration of genipin in the composite <0.5 wt % was not enough to fully crosslink the gelatin, it results in a rapid degradation of the gelatin-genipin mixture. However, we also found that the foreign body capsule surrounding the GGT composite containing 1.0 wt % of the genipin was much thicker than that in the other three groups, that is, the composites containing 0.05, 0.1, and 0.5 wt % of the genipin. We therefore concluded that the ideal concentration of genipin used in the GGT was 0.5 wt %. Finally, we examined the organ culture units, which were maintained in cultured medium for 5 weeks. Morphology of tissue was observed and the quantitative evaluation of the regenerated bone was determined. We found that the GGT composites containing 0.5 wt % of the genipin had an excellent biocompatibility and could produce osteoconduction for the regenerating bone tissues.

Animals↗

A new bone-inducing biodegradable porous beta-tricalcium phosphate.

A new type of degradable biomaterial with bone-inducing capacity was made by combining porous beta-tricalcium phosphate (beta-TCP) with a delivery system for recombinant human bone morphogenetic protein-2 (rhBMP-2). The BMP delivery system consisted of a block copolymer composed of poly-D,L-lactic acid with random insertion of p-dioxanone and polyethylene glycol (PLA-DX-PEG), a known biocompatible and biodegradable material. The efficacy of this biomaterial in terms of its bone-inducing capacity was examined by ectopic bone formation in the dorsal muscles of the mouse. In the beta-TCP implants coated with the PLA-DX-PEG polymer containing more than 0.0025% (w/w) of rhBMP-2, new ectopic bone tissues with marrow were consistently found on the surface of implants. The radiographic density of beta-TCP was diminished in a time-dependent manner. On histological examination, numerous multinucleated osteoclasts with positive tartrate-resistant acid-phosphatase (TRAP) staining were noted on the surface of the beta-TCP. These experimental results indicate that beta-TCP implants coated with synthetic rhBMP-2 delivery system might provide effective artificial bone-graft substitutes with osteoinductive capacity and biodegradable properties. In addition, this type of biomaterial may require less rhBMP-2 to induce significant new bone mass.

Absorbable Implants↗

Bone marrow genesis after subcutaneous delivery of rat osteogenic cell-seeded biodegradable scaffolds into nude mice.

This study describes the generation of an active hematopoietic marrow within the confines of a biodegradable, macroporous polyester scaffold, seeded with rat osteogenic cells, after subcutaneous implantation in nude mice. A macroporous, poly(DL-lactide-co-glycolide) polymer scaffold, into which resorbable calcium phosphate particles were incorporated, was seeded with rat bone marrow-derived cells. Scanning electron microscopy of the cell-seeded scaffold demonstrated confluent cell colonization. Scaffolds seeded with cells were implanted under the dorsum of immunocompromised mice for 5 weeks. Histological analysis revealed bone formation along the scaffold pores creating bony cavities within which a host-derived, hematopoietic marrow was observed which included hematopoietic precursors, megakaryocytes, fat cells, and numerous marrow sinusoids. In those areas where bone was not elaborated on the scaffold surface, no marrow genesis was observed and the scaffold interstices were filled with fibrous tissue. These results demonstrate the utility of this biodegradable scaffold in delivery of a phenotypically functional cell population for bone tissue and bone marrow engineering applications. Moreover, the recapitulation of hematopoietic marrow tissue within the engineered bony cavities also provides a new experimental environment with which to further investigate the interactions of hematopoietic and nonhematopoietic compartments of the marrow microenvironment.

Animals↗

Role of protein kinase C in the monocyte-derived macrophage-mediated biodegradation of polycarbonate-based polyurethanes.

Polycarbonate-polyurethanes (PCNUs) elicit a foreign body reaction during the initial tissue contact, partly mediated by the respiratory burst in monocytes, during which protein kinase C (PKC) activates NADPH (nicotinamide adenine dinucleotide phosphate) oxidase. Using an in vitro cell system, monocytes were differentiated into monocyte-derived macrophages (MDMs) and then reseeded onto three PCNUs (HDI431, HDI321, or MDI321): hexane (HDI) or 4,4-methylene bis-phenyl (MDI) diisocyanates synthesized with poly(1,6-hexyl 1,2-ethyl carbonate) diol (PCN) and 14C-labeled butanediol (BD) in the ratios 4:3:1 or 3:2:1 (diisocyanate/PCN/BD). MDM-mediated degradation was assessed by radiolabel release in the presence of a PKC activator (phorbol myristate acetate), inhibitor (H7), and a catalase/peroxidase inhibitor (NaN3). Activating PKC decreased biodegradation and esterase activity in MDMs on HDI431 and HDI321 but not MDI321, whereas H7 and NaN3 inhibited the MDM degradation of MDI321 only. Pretreatment of the PCNUs with H2O2 inhibited esterase-mediated radiolabel release from HDI431 and HDI321 but stimulated radiolabel release from MDI321. The difference in the effect of H2O2 on the HDI versus MDI PCNUs contributes to explaining the effect of PKC activation on material degradation. Understanding the mechanism by which this pathway is linked to PCNU chemistry may assist in designing materials with tailored biodegradation rates.

1-(5-Isoquinolinesulfonyl)-2-Methylpiperazine↗

Controlled drug release from a novel injectable biodegradable microsphere/scaffold composite based on poly(propylene fumarate).

The ideal biomaterial for the repair of bone defects is expected to have good mechanical properties, be fabricated easily into a desired shape, support cell attachment, allow controlled release of bioactive factors to induce bone formation, and biodegrade into nontoxic products to permit natural bone formation and remodeling. The synthetic polymer poly(propylene fumarate) (PPF) holds great promise as such a biomaterial. In previous work we developed poly(DL-lactic-co-glycolic acid) (PLGA) and PPF microspheres for the controlled delivery of bioactive molecules. This study presents an approach to incorporate these microspheres into an injectable, porous PPF scaffold. Model drug Texas red dextran (TRD) was encapsulated into biodegradable PLGA and PPF microspheres at 2 microg/mg microsphere. Five porous composite formulations were fabricated via a gas foaming technique by combining the injectable PPF paste with the PLGA or PPF microspheres at 100 or 250 mg microsphere per composite formulation, or a control aqueous TRD solution (200 microg per composite). All scaffolds had an interconnected pore network with an average porosity of 64.8 +/- 3.6%. The presence of microspheres in the composite scaffolds was confirmed by scanning electron microscopy and confocal microscopy. The composite scaffolds exhibited a sustained release of the model drug for at least 28 days and had minimal burst release during the initial phase of release, as compared to drug release from microspheres alone. The compressive moduli of the scaffolds were between 2.4 and 26.2 MPa after fabrication, and between 14.9 and 62.8 MPa after 28 days in PBS. The scaffolds containing PPF microspheres exhibited a significantly higher initial compressive modulus than those containing PLGA microspheres. Increasing the amount of microspheres in the composites was found to significantly decrease the initial compressive modulus. The novel injectable PPF-based microsphere/scaffold composites developed in this study are promising to serve as vehicles for controlled drug delivery for bone tissue engineering.

Bone Cements↗

Human neutrophils reaction to the biodegraded nano-hydroxyapatite/collagen and nano-hydroxyapatite/collagen/poly(L-lactic acid) composites.

The impact of biodegraded nano-hydroxyapatite/collagen (nHAC) composite and nano-hydroxyapatite/collagen/poly(L-lactic acid) (nHAC/PLA) scaffold composite on neutrophils reaction was evaluated in vitro. Neutrophils were separated from human peripheral blood of healthy subjects. The nHAC and nHAC/PLA materials were immersed in the D-Hanks' Balanced Salt Solution (D-HBSS) for 1 day, 7 days and 2, 4, 8 weeks (37 degrees C) as testing solution, which mixed with the neutrophils for 1 h. Both of the nHAC and nHAC/PLA materials were shown the same cell survival rate as blank control, but the lactate dehydrogenase (LDH) and tumor necrosis factor alpha (TNF-alpha) released from the neutrophils were increased significantly after the 2 weeks in nHAC sample. The possible reason relied on the high concentration of calcium due to the quick biodegradation of the nHAC material. Before 2 weeks, the LDH value of nHAC/PLA is higher than that of nHAC sample that corresponded to the initial PLA degradation in vitro. This study provided the biocompatibility test of neutrophils other than common methods, such as osteoblastic cells for biomimetic materials. Moreover, it demonstrated the calcium concentration stimulating effect for cytokine release from neutrophils.

Biocompatible Materials↗

Effects of a biodegradable polymer synthesized with inorganic tin on the chondrogenesis of human articular chondrocytes.

Recent study has shown that biodegradable polymers are attractive candidates for chondrocyte fixation and further transplantation in cartilage tissue engineering. Poly (glycolic acid) (PGA), a polymer of glycolic acid, is widely used in orthopedic applications as a biodegradable polymer. Organotin, lead, antimony, and zinc are catalysts commonly used in synthesizing PGA. Here, we investigated the biocompatibility of PGA, synthesized with and without inorganic tin as a catalyst in chondrogenesis of human articular chondrocytes in a micromass culture system. Significant enhancement of chondrocyte proliferation and expression of the collagen type II protein gene were observed in cultures treated with PGA synthesized with a tin catalyst. However, aggrecan gene expression was very similar to the control culture. Amount of collagen type II protein was also increased in the same group of cultured chondrocytes. In contrast, PGA without a catalyst caused overall inhibition of chondrogenesis. Despite several positive findings, extensive investigations are essential for the feasibility of this PGA(Sn) in future clinical practice.

Absorbable Implants↗

Biodegradable polyurethane cytocompatibility to fibroblasts and staphylococci.

Biodegradable polyurethanes have potential for use as implantable devices (orthopedic, maxillofacial, cardiovascular, wound dressing and plastic surgery) because of their controllable elasticity, and the possibility of changing their chemistry and structure. Studying bacterial and cell adhesion to polyurethanes helps to determine surface cytocompatibility and suitability for in vivo trials. Staphylococcus aureus, Staphylococcus epidermidis and hTERT human fibroblast cells were used to determine the cytocompatibility of experimental biodegradable polyurethanes (PUs) with different hydrophobic-to-hydrophilic (pho:phi) content ratios (100% pho, 70% pho, and 30% pho). Poly(L/DL-lactide) 70/30% (PLDL) and Thermanox were used as control surfaces. Surface characterization using noncontact profilometry, contact angles, and scanning electron microscopy (SEM) showed that the three PU surfaces, PLDL, and Thermanox have different properties. On the 100% PU and 30% PU surfaces, hTERT cells spread less in comparison to the 70% PU, PLDL, and Thermanox surfaces. The adsorption of fibronectin to the surfaces had no effect on the adhesion and spreading of hTERT cells when compared to the uncoated surfaces. The trend for S. aureus was the most adhered on the 70% PU and 30% PU, then Thermanox, followed by 100% PU and PLDL, respectively. The amount of S. epidermidis adhesion followed the trend of the most on 70% PU, then 100% PU, then 30% PU and PLDL, and the least on Thermanox. These results suggest that the 70% PU surface is cytocompatible to hTERT fibroblasts, while the 100% PU and 30% PU were not. All surfaces encouraged S. aureus and S. epidermidis colonization, particularly the 70% PU.

Bacterial Adhesion↗

Site-specific delivery of dexamethasone from biodegradable implants reduces formation of pericardial adhesions in rabbits.

Repeated sternotomy often leads to serious complications in patients due to the formation of cardiac adhesions. In this study we characterized dexamethasone-loaded biodegradable poly(lactide)-poly(ethyleneglycol) copolymer films for site-specific drug delivery and examined their efficacy in the rabbit model of postoperative cardiac adhesions. Tritiated dexamethasone-loaded films were used to determine the in vitro release and in vivo drug distribution. Dexamethasone release in serum was biphasic with 69% drug released after 72 hr. The implants produced sustained drug levels at the implantation site with low distribution into the peripheral tissues. The matrices were implanted in rabbits between the epicardium and the sternum following sternotomy, pericardiectomy and epicardium abrasion, with the drug-releasing surface facing the epicardium. The tenacity and density of the adhesions was examined 21 days post procedure in comparison to both groups of untreated and rabbits implanted with blank matrices. Similarly tenacious and dense adhesions were observed in both control groups. In contrast, epicardial adhesions' formation was significantly reduced and the anatomy was preserved in the treated animals. It is concluded that local delivery of dexamethasone from biodegradable implants provides a promising approach for the prevention of pericardial adhesions while potentially minimizing the systemic adverse effects inherent to systemic therapy or high blood levels of the drug.

Animals↗

The preparation of monodisperse biodegradable polyester nanoparticles with a controlled size.

In local drug delivery, nanoparticles based on biodegradable polymers can function as vehicles with controlled drug-release properties. To achieve a well-controlled drug-release profile, control over the particle size is of great importance. Therefore, biodegradable polyester nanoparticles were prepared by the salting-out method. Process variables were varied to study the effect on the particle size. The monodisperse particles obtained were between 100 and 400 nm in size and spherical in shape. It was found that the particle size could be adjusted by varying the preparation conditions upon which the polymer concentration had the most pronounced effect.

Chemistry, Pharmaceutical↗

Use of stereolithography to manufacture critical-sized 3D biodegradable scaffolds for bone ingrowth.

A novel approach to the manufacture of biodegradable polymeric scaffolds for tissue-engineering utilizing stereolithography (SLA) is presented. SLA is a three-dimensional (3D) printing method that uses an ultraviolet laser to photo-crosslink a liquid polymer substrate. The current generation of SLA devices provide a 3D printing resolution of 0.1 mm. The experiments utilized a biodegradable resin mixture of diethyl fumarate (DEF), poly(propylene fumarate) (PPF), and a photoinitiator, bisacylphosphine oxide (BAPO). The PPF is crosslinked with the use of the SLA's UV laser (325-nm wavelength). An SLA device was retrofitted with a custom fixture build tank enclosing an elevator-driven build table. A 3D prototype model testing the manufacturing control this device provides was created in a computer-aided-design package. The resulting geometric data were used to drive the SLA process, and a DEF/PPF prototype part was successfully manufactured. These scaffolds have application in the tissue engineering of bony substrates.

Biocompatible Materials↗

Biodegradable microspheres. XIII: Immune response to the DNP hapten conjugated to polyacryl starch microparticles.

Polyacryl starch microparticles are being investigated for use as drug carriers, especially in the treatment of intracellular parasitic diseases. The purpose of this work was to investigate the possible immune response to drugs coupled to the microparticles, using the dinitrophenyl group (DNP) as a model. The humoral immunogenicity of DNP hapten-conjugated polyacryl starch microparticles has been examined in mice. Microparticle:hapten complexes with different biodegradability were tested, as well as different dosages and routes of administration. Two DNP derivatives, Lys(DNP) and Leu-Ala-Lys(DNP), were coupled to microparticles. It was shown that Lys(DNP) was released from the particles by lysosomal enzymes only from the conjugate with the tripeptide DNP derivative. The DNP conjugated to the particles via the biodegradable Leu-Ala-Lys arm induced only a weak immune response without memory. No response was detected after injection of the Lys(DNP) microparticles. Thus, there should be no major immunological obstacles in using drug:microparticle complexes in the treatment of, for example, parasitic diseases.

Adjuvants, Immunologic↗

Biodegradable, thermosensitive implant for approximating cylindrical structures: a preliminary study.

A new invention, i.e., a biodegradable, thermosensitive hybrid gel composite in the form of a thin sheet, was used as an implant inside the rat and guinea pig to test its tissue reactions, degradation, and function as a bridging agent. Tissue tractions in subcutaneous tissue, in muscle, around a peripheral nerve, and around an artery were mild. Degradation made rapid progress, starting on the third day and completed in 2-3 weeks. The hybrid gel, when wrapped around the cut ends of a peripheral nerve or an artery, functioned well as a bridging tube. In the case of the cut nerve, regenerating fascicles crept through the tube which protected them from fibrosis. In the case of the cut artery, patency of flow was maintained, and arterial wall healing was complete in 2-3 weeks. The hybrid gel composite contracted at body temperature, thus holding well to body tissues. Its biodegradable and inert nature offers the potential for future use as a tissue wrap and bridging agent.

Absorbable Implants↗

Adenoviral BMP-2 gene transfer in mesenchymal stem cells: in vitro and in vivo bone formation on biodegradable polymer scaffolds.

The aim of this study was to determine the feasibility of adenoviral gene transfer into primary human bone marrow osteoprogenitor cells in combination with biodegradeable scaffolds to tissue-engineer bone. Osteoprogenitors were infected with AxCAOBMP-2, a vector carrying the human BMP-2 gene. Alkaline phosphatase activity was induced in C2C12 cells following culture with conditioned media from BMP-2 expressing cells, confirming successful secretion of active BMP-2. Expression of alkaline phosphatase activity, type I collagen and mineralisation confirmed bone cell differentiation and maintenance of the osteoblast phenotype in extended culture for up to 6 weeks on PLGA porous scaffolds. In vivo implantation of adenoviral osteoprogenitor constructs on PLGA biodegradeable scaffolds, using diffusion chambers, also demonstrated bone cell differentiation and production of bone tissue. The maintenance of the osteoblast phenotype in extended culture and generation of mineralised 3-D scaffolds containing such constructs indicate the potential of such bone tissue engineering approaches in bone repair.

Absorbable Implants↗