PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “NITROGEN DIOXIDE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Personal exposure and health effect relationship for NO2 with urinary hydroxyproline to creatinine ratio as indicator.

Establishment of an exposure-effect relationship was attempted between personal nitrogen dioxide (NO2) exposure and urinary hydroxyproline to creatinine ratio of approximately 800 adult women, who were mothers of primary schoolchildren living in two communities around Tokyo. Daily average of the personal NO2 exposure (ENO2) was measured during wintertime by a newly developed personal monitor exposed for 24 hours. The hydroxyproline to creatinine ratio (HOP:C) in the urine sample collected early in the morning of the day for ENO2 measurement was used as a biochemical indicator of the health effect of NO2 exposure. The HOP:C was found to have significant correlation with ENO2 and number of cigarettes smoked actively and passively. ENO2, however, had no correlation with the intensity of the smoking levels; they might affect HOP:C independently. Stepwise multiple regression analysis revealed that HOP:C could be predicted by ENO2 and smoking habits at a high confidence level. The regression analysis of the active smokers' group indicated that a few cigarettes was enough to increase the HOP:C, while in the case of passive smoking, HOP:C increased proportionally to the number of cigarettes.

Adult↗

Epidemiological-environmental study of diesel bus garage workers: acute effects of NO2 and respirable particulate on the respiratory system.

Personal samples of nitrogen dioxide (NO2) and respirable particulate (RP) were collected over the shift on 232 workers in four diesel bus garages. Response was assessed by an acute respiratory questionnaire and before and after shift spirometry. Measures of exposure to NO2 and RP were associated with work-related symptoms of cough; itching, burning, or watering eyes; difficult or labored breathing; chest tightness; and wheeze. The prevalence of burning eyes, headaches, difficult or labored breathing, nausea, and wheeze experienced at work were higher in the diesel bus garage workers than in a comparison population of battery workers, while the prevalence of headaches was reduced. Mean reductions in forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1), peak flow, and flows at 50 and 75% of FVC were not obviously different from zero. There was no detectable association of exposure to NO2 or respirable particulate and acute reductions in pulmonary function. Workers who often had respiratory work-related symptoms generally had a slightly greater mean acute reduction in FEV1 and FEF50 than did those who did not have these symptoms, but these differences were not statistically significant.

Adolescent↗

Long-term exposure to ambient air pollution and cardiopulmonary mortality in women.

BACKGROUND: Living close to major roads or highways has been suggested to almost double the risk of dying from cardiopulmonary causes. We assessed whether long-term exposure to air pollution originating from motorized traffic and industrial sources is associated with total and cause-specific mortality in a cohort of women living in North Rhine-Westphalia, Germany. METHODS: The study was a follow-up of a series of cross-sectional studies carried out during the 1980s and 1990s on the health of women (age 50-59 years). Approximately 4800 women were followed up for vital status and migration. Exposure to air pollution was defined by distance to major roads calculated from Geographic Information System data and by 1- and 5-year average nitrogen dioxide (NO2) and particle (PM10) concentrations calculated from air monitoring station data. We analyzed associations between exposure and mortality using Cox's proportional hazards models adjusting for confounders. Relative risks (RRs) refer to an interquartile range increase in exposure (16 microg/m for NO2; 7 microg/m for PM10). RESULTS: During the follow-up period, 8% of the women died, 3% from cardiopulmonary causes. Cardiopulmonary mortality was associated with living within a 50-meter radius of a major road (adjusted RR = 1.70; 95% confidence interval = 1.02-2.81), with NO2 (1.57; 1.23-2.00 for 1-year average), and with PM10 (1.34; 1.06-1.71 for 1-year average). Exposure to NO2 was also associated with all-cause mortality (1.17; 1.02-1.34). No association was seen with noncardiopulmonary nonlung cancer mortality. CONCLUSIONS: Living close to major roads and chronic exposure to NO2 and PM10 may be associated with an increased mortality due to cardiopulmonary causes.

Aged↗

An experimental in vitro model for dynamic direct exposure of human cells to airborne contaminants.

The aim of this study was to establish a dynamic in vitro model for direct exposure of human cells to gaseous contaminants to investigate the cellular responses to airborne chemical exposures. Nitrogen dioxide (NO2) was selected as a model gas compound. Standard test atmospheres were generated (2.5-10 ppm), using a dynamic direct dilution method. Human cells including: A549 pulmonary type II-like epithelial cell lines and skin fibroblasts were grown on porous membranes. Human cells on snapwell inserts were placed in horizontal diffusion chambers and exposed to various airborne concentrations of NO2 directly at the air/liquid interface for 1 h at 37 degrees C. Cytotoxicity of the test gas was investigated using the MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium), NRU (neutral red uptake) and ATP (Adenosine triphosphate) assays. Dose-dependent effects of NO2 were observed in human cells tested which resulted in a significant reduction of cell viability at concentrations normally encountered in workplace environments (p<0.05). Our findings suggest that the dynamic direct exposure method can be used for in vitro inhalational and dermal toxicity studies and potentially as an advanced technology for biomonitoring of airborne contaminants in future occupational and environmental toxicity assessments.

Air Pollutants↗

Cell type-dependent release of nitric oxide and/or reactive nitrogenoxide species from intracellular SIN-1: effects on cellular NAD(P)H.

SIN-1 is frequently used in cell culture studies as an extracellularly operating generator of peroxynitrite. However, little is known about the nature of the reactive species produced intracellulary from SIN-1. SIN-1 can easily penetrate cells as exemplified for both L-929 mouse fibroblasts and bovine aortic endothelial cells (BAECs) by utilizing capillary zone electrophoresis. In L-929 cells, SIN-1 produced nitric oxide (*NO) as monitored by the fluorescent *NO scavenger FNOCT-1 and by means of a *NO electrode, as well as reactive nitrogenoxide species (RNOS, e.g. peroxynitrite, nitrogen dioxide, dinitrogen trioxide), as detected with the fluorescent indicator DAF-2. Laser scanning microscopy revealed that in L-929 cells SIN-1 -derived species initially oxidized the major fraction of the NAD(P)H within the cytosol and the nuclei, whereas the mitochondrial NAD(P)H level was somewhat increased. In marked contrast to this, in BAECs no evidence for *NO formation was found although the intracellular amount of SIN-1 was four-fold higher than in L-929 cells. In BAECs, the level of NAD(P)H was slightly decreased within the first 10 min after administration of SIN-1 in both the cytosol/nuclei and mitochondria. These observations reflect the capability of SIN-1 to generate intracellularly either almost exclusively RNOS as in BAECs, or RNOS and freely diffusing *NO as in L-929 cells. Nitric oxide as well as RNOS may decisively affect cellular metabolism as indicated by the alterations in the NAD(P)H level. Hence, care should be taken when applying SIN-1 as an exclusively peroxynitrite-generating compound in cell culture systems.

Animals↗

Nitrification and denitrification as a source for NO and NO2 production in high-strength wastewater.

Laboratory and half-technical scale experiments were performed to evaluate nitric oxide (NO) and nitrogen dioxide (NO2) production during biological N-elimination from wastewater with high ammonium concentration (about 700 mg N L-1). In a laboratory scale bioreactor with biomass retention, the ammonia oxidizer Nitrosomonas europaea and the denitrifier Paracoccus denitrificans were grown as reference organisms in co-culture in order to simulate the nitrifying and denitrifying community of wastewater treatment plants. Synthetic wastewater and sludge liquor from the municipal wastewater treatment plant in Lueneburg (Germany) were used. In the laboratory scale reactor, during the treatment of synthetic wastewater, 0.28% of the oxidized ammonium-N was released as NO-N by a pure culture of Nitrosomonas. A simultaneously nitrifying and denitrifying co-culture only released 0.04 to 0.2%. NO2 formation was not observed. NO production was much higher in sludge liquor. A pure culture of Nitrosomonas produced 0.52% NO + NO2-N (= NOx-N), a co-culture of Nitrosomonas and Paracoccus even 1.64% NOx-N. The production rate strongly depended on the media and the organisms used. In a co-culture of N. europaea and P denitrificans, Nitrosomonas was shown to be the most efficient NO producer. NO production increased with ammonium oxidation rate and with nitrite concentration of the medium. In synthetic wastewater, NO production was not influenced by reduced oxygen content. However, in sludge liquor NO production rate increased with decreasing O2 concentration. Here, for the first time, the formation of significant amounts of NO2 during simultaneous nitrification/denitrification could be demonstrated. In half-technical scale experiments, only 0.07% of the oxidized ammonium-N was released as NO-N from the nitrification stage. NO2 was not detectable. Release of nitric oxide from the denitrification stage was mainly diffusion limited and the amount produced did not exceed 0.0001%. A calculation on the basis of the results presented, revealed that biological treatment of nitrogen-rich wastewater is not a significant source for pollution of the atmosphere with NOx in industrial areas.

Biodegradation, Environmental↗

Effects of subchronic and chronic exposure to ambient air pollutants on infant bronchiolitis.

Ambient air pollutant exposure has been linked to childhood respiratory disease, but infants have received little study. The authors tested the hypotheses that subchronic and chronic exposure to fine particulate matter (particulate matter < or = 2.5 microm in aerodynamic diameter (PM2.5)), nitrogen dioxide, carbon monoxide, and ozone increases risk of severe infant bronchiolitis requiring hospitalization. Study subjects were derived from linked birth-hospital-discharge records of infants born in 1995-2000 in the South Coast Air Basin of California. Cases with a hospital discharge for bronchiolitis in infancy were matched to 10 age- and gestational-age-matched controls. Exposures in the month prior to hospitalization (subchronic) and mean lifetime exposure (chronic) referenced to the case diagnosis date were assessed on the basis of data derived from the California Air Resources Board. In conditional logistic regression, only subchronic and chronic PM2.5 exposures were associated with increased risk of bronchiolitis hospitalization after adjustment for confounders (per 10-microg/m3 increase, adjusted odds ratio = 1.09 (95% confidence interval: 1.04, 1.14) for both). Ozone was associated with reduced risk in the single-pollutant model, but this relation did not persist in multipollutant models including PM2.5. These unique US data suggest that infant bronchiolitis may be added to the list of adverse effects of PM2.5 exposure.

Air Pollutants↗

Association of severe asthma attacks with weather, pollen, and air pollutants.

BACKGROUND: The association between exacerbations of asthma and weather or air pollution is not well understood. The relationships between visits to the emergency room for asthma attacks and the meteorological, aerobiological, and chemical characteristics of the outdoor air have been evaluated. METHODS: The number of daily attendances for asthma attacks at the emergency room of Oulu University Central Hospital was recorded over one year together with daily meteorological readings (temperature, humidity, barometric pressure, rainfall), levels of air pollutants (nitrogen dioxide (NO2), sulphur dioxide (SO2), hydrogen sulphide (H2S), total suspended particles (TSP)), and pollen counts (birch, alder, pine, willow, total pollen). The relationship between the number of attendances and the measured variables was then analysed by multiple regression and stepwise discriminant analysis. RESULTS: The total number of attendances during the year was 232, with lower figures in summer and higher in winter. No association was found between visits for asthma attacks and airborne pollen levels or meteorological factors except for temperature, which had a low inverse correlation with attendance. The most significant correlations were found between asthma visits and the levels of NO2; those for SO2, TSP, and H2S were also significant. Intercorrelations between SO2 and temperature or NO2 and between temperature and TSP or NO2 were also found, but only NO2 correlated significantly with attendances after standardisation for temperature. CONCLUSIONS: Increased levels of pollutants, especially NO2, were associated with attacks of asthma, but the explanation for this is unclear. Air pollen levels were not associated with asthma attacks and only temperature among the meteorological factors had a small association with asthma.

Adolescent↗

Differential inhibition of inflammatory cytokine release from cultured alveolar macrophages from smokers and non-smokers by NO2.

Human alveolar macrophages (AMs) obtained from smokers and non-smokers by bronchoalveolar lavage (BAL) were subjected to various concentrations of NO2 in an inverted monolayer exposure model. Culture supernatants were collected 4 h after the exposure and assayed for secreted TNF-alpha, IL-1 beta, IL-8 and MIP-1 alpha. The steady state levels of the mRNAs for these cytokines were also analysed in the cells. The adherence of BAL cells to plastic prior to exposure to the gas elevated the steady state mRNA levels of all four cytokines tested in smoker's cells and that of TNF-alpha and IL-1 beta, but not IL-8 (MIP-1 alpha not tested), in non-smoker's cells. Interestingly, adherent cells from non-smokers released circa 15-, 3-, 1.5- and 3-fold the amounts of IL-1 beta, IL-8, TNF-alpha and MIP-1 alpha, respectively, than smoker's cells during control incubation or exposure to air. A 20 min exposure to NO2 (5 or 20 p.p.m.) did not increase the secretion of any of the cytokines from either cell type. In contrast, NO2 caused a concentration-dependent inhibition of the secretion of all cytokines except IL-1 beta from smoker's cells. Additionally, NO2 greatly diminished the release of all cytokines in response to further treatment with lipopolysaccharide (LPS). In contrast, only the secretion of TNF-alpha from non-smoker's cells was inhibited by the gas in a concentration-dependent manner, whilst LPS-induced secretion of the cytokines was not affected by the gas. The steady state levels of the respective mRNAs for each of the cytokines were not significantly affected in smoker's cells by exposure to NO2, except for a negative, dose-dependent trend in the case of TNF-alpha. Nitrogen dioxide also failed to elevate the levels of the mRNAs in non-smoker's cells but, again, tended to diminish the levels, particularly of IL-1 beta mRNA. However, exposure to the gas inhibited LPS-induced accumulation of cytokine mRNAs in smoker's cells only. The data suggest that macrophage-derived cytokine mediators of the sepsis response may not play a role in the generation of NO2-induced inflammation in the human lung. Conversely, the gas seems to non-specifically inhibit the release and/or production of cytokines, particularly from smoker's cells, at the post-transcriptional level, and impairs the ability of the cells to increase the transcription and release of the cytokines in response to bacterial LPS. The fact that NO2 seriously impaired the already diminished capacity of smoker's cells to release several important pro-inflammatory cytokines, both under control conditions and in response to LPS, strongly suggest that the inhalation of NO2 in cigarette smoke may contribute to impairing host defence against infection in the lung.

Adult↗

Traffic-related air pollution and otitis media.

BACKGROUND: Otitis media is one of the most common infections in young children. Although exposure to environmental tobacco smoke is a known risk factor associated with otitis media, little information is available regarding the potential association with air pollution. OBJECTIVE: We set out to study the relationship between exposure to traffic-related air pollution and otitis media in two birth cohorts. METHODS: Individual estimates of outdoor concentrations of traffic-related air pollutants-nitrogen dioxide, fine particles [particulate matter with aerodynamic diameters </= 2.5 microm (PM2.5)], and elemental carbon-were calculated for home addresses of approximately 3,700 and 650 infants from birth cohort studies in the Netherlands and Germany, respectively. Air pollution exposure was analyzed in relation to physician diagnosis of otitis media in the first 2 years of life. RESULTS: Odds ratios (adjusted for known major risk factors) for otitis media indicated positive associations with traffic-related air pollutants. An increase in 3 microg/m3 PM2.5, 0.5 microg/m3 elemental carbon, and 10 microg/m3 NO2 was associated with odds ratios of 1.13 (95% confidence interval, 1.00-1.27) , 1.10 (1.00-1.22) , and 1.14 (1.03-1.27) in the Netherlands and 1.24 (0.84-1.83) , 1.10 (0.86-1.41) , and 1.14 (0.87-1.49) in Germany, respectively. CONCLUSIONS: These findings indicate an association between exposure to traffic-related air pollutants and the incidence of otitis media. Given the ubiquitous nature of air pollution exposure and the importance of otitis media to children's health, these findings have significant public health implications.

Air Pollutants↗

Global atmospheric change: potential health effects of acid aerosol and oxidant gas mixtures.

Inhalation toxicology experiments in whole animals have demonstrated a remarkable lack of toxicity of sulfuric acid in the form of respirable aerosols, especially in rats and nonhuman primates. Thus, much of the current experimental emphasis has shifted to the evaluation of the potential health effects of acid aerosols as components of mixtures. Rats have been concurrently exposed to mixtures of ozone or nitrogen dioxide with respirable-sized aerosols of sulfuric acid, ammonium sulfate, or sodium chloride, or to each pollutant individually. Their responses to such exposures have been evaluated by various quantitative biochemical analysis of lung tissue or wash fluids ("lavage fluid") or by quantitative morphological methods ("morphometry"). Such studies have mainly been performed in the acute time frame due to the inherent limitations of the most sensitive assays available and have generally involved exposures for 1 to 9 days, depending on the assays used. Good correlations were found between the most sensitive biochemical indicators of lung damage (protein content of lung lavage fluid or whole lung tissue and lung collagen synthesis rate) and the exposure concentration of oxidant gas present alone or in mixtures with acidic aerosols showing interactive effects. Synergistic interaction between ozone and sulfuric acid aerosol was demonstrated to occur at environmentally relevant concentrations of both pollutants by several of the analytical methods used in this study. Such interactions were demonstrated at concentrations of ozone as low as 0.12 ppm and of sulfuric acid aerosol at concentrations as low as 5 to 20 micrograms/m3.(ABSTRACT TRUNCATED AT 250 WORDS)

Acids↗

Air pollution and emergency department visits for asthma among Ohio Medicaid recipients, 1991-1996.

We examined the effects of nitrogen dioxide (NO(2)), ozone (O(3)), particulate matter of <10 microm aerodynamic diameter (PM(10)), and sulfur dioxide (SO(2)) on asthmatics ages 5-34 years enrolled in Medicaid in Cincinnati, Cleveland, and Columbus, OH (N=5416). Our study period was for the summer months, June-August, from July 1, 1991 to June 30, 1996. We preformed Poisson regression analyses for the number of daily emergency department (ED) visits for asthma in each city and on the aggregate data controlling for time trends and minimum temperature. We found a 12% increased likelihood of an asthma ED visit per 50 microg/m(3) increase in PM(10) in Cleveland [95% confidence interval (CI)=0-27%] and a 35% increase per 50 microg/m(3) increase in SO(2) in Cincinnati (95% CI=9-21%). When data were analyzed for all three cities combined, the risk of an ED visit increased for all pollutant increases and specifically by 12% (95% CI=1-23%) per 50 microg/m(3) increase in SO(2). Attributable risk estimates show a five times greater impact on Cleveland over Cincinnati or Columbus. Between 1991 and 1996, air pollutants in Cincinnati, Cleveland, and Columbus increased ED visits for asthmatics enrolled in Medicaid.

Adolescent↗

Can O=NOOH undergo homolysis?

Recent thermodynamic calculations of Merenyi and Lind [(1997) Chem. Res. Toxicol. 10, 1216-1220] suggest that O=NOOH can undergo homolysis to form the hydroxyl radical and nitrogen dioxide. This result is based in part on our statement that the enthalpy of ionization of O=NOOH is close to zero [Koppenol et al. (1992) Chem. Res. Toxicol. 5, 834-842]. As the ionization of O=NOOH is sensitive to the milieu and the rate of isomerization (to nitrate) to the total concentration of O=NOOH and O=NOO- [Kissner et al. (1997) Chem. Res. Toxicol. 10, 1285-1292], we reinvestigated the temperature dependence of the ionization constant and determined a deltaHo of 4+/-2 kcal mol(-1). This results in a standard Gibbs energy of homolysis of 16 kcal mol(-1) and a rate of homolysis of 1 x 10(-2) s[-1]. Given the uncertainty in the Gibbs energy of homolysis, upper and lower rates are 1 x 10(-4) and 0.6 s(-1), slower than the rate of isomerization, 1.2 s(-1) at 25 degrees C. The recombination of the homolysis products NO2. and HO. is known to lead to mainly peroxynitrous acid. If one assumes that a few percent of the recombinations lead to nitrate instead, then the rate of homolysis must be much higher than the rate of isomerization. We conclude therefore that homolysis is unlikely.

Entropy↗

Characterization of firefighter exposures during fire overhaul.

Previous studies have characterized firefighter exposures during fire suppression. However, minimal information is available regarding firefighter exposures during overhaul, when firefighters look for hidden fire inside attics, ceilings, and walls, often without respiratory protection. A comprehensive air monitoring study was conducted to characterize City of Phoenix firefighter exposures during the overhaul phase of 25 structure fires. Personal samples were collected for aldehydes; benzene; toluene; ethyl benzene; xylene; hydrochloric acid; polynuclear aromatic hydrocarbons (PNA); respirable dust; and hydrogen cyanide (HCN). Gas analyzers were employed to continuously monitor carbon monoxide (CO), HCN, nitrogen dioxide (NO2), and sulfur dioxide (SO2). Area samples were collected for asbestos, metals (Cd, Cr, Pb), and total dust. During overhaul the following exceeded published ceiling values: acrolein (American Conference of Governmental Industrial Hygienists [ACGIH] 0.1 ppm) at 1 fire; CO (National Institute for Occupational Safety and Health [NIOSH] 200 ppm) at 5 fires; formaldehyde (NIOSH 0.1 ppm) at 22 fires; and glutaraldehyde (ACGIH 0.05 ppm) at 5 fires. In addition, the following exceeded published short-term exposure limit values: benzene (NIOSH 1 ppm) at two fires, NO2 (NIOSH 1 ppm) at two fires, and SO2 (ACGIH 5 ppm) at five fires. On an additive effects basis, PNA concentrations exceeded the NIOSH recommended exposure limits (0.1 mg/M3) for coal tar pitch volatiles at two fires. Maximum concentrations of other sampled substances were below their respective permissible exposure limits. Initial 10-min average CO concentrations did not predict concentrations of other products of combustion. The results indicate that firefighters should use respiratory protection during overhaul. In addition, these findings suggest that CO should not be used as an indicator gas for other contaminants found in this atmosphere.

Air Pollutants, Occupational↗

Clinical monitoring of inhaled nitric oxide: comparison of chemiluminescent and electrochemical sensors.

In view of the rapidly increasing use of inhaled nitric oxide for infants with potentially reversible pulmonary hypertension, the ability to accurately measure nitric oxide and its by-products is an increasingly important safety issue. The authors evaluated the abilities of two chemiluminescent analyzers and two electrochemical sensors to detect known concentrations of nitric oxide (NO) and nitrogen dioxide (NO2). A calibrated mass spectrometer was utilized to determine the reference levels of NO2. Mass flowmeters calibrated with bubble flowmeters and an audited cylinder of NO were utilized to determine the levels of NO. In a test laboratory environment, all sensors yielded reasonably accurate measurements of NO. It was observed, however, that the amounts of NO recorded by the candidate analyzers in an 82% oxygen environment were slightly low compared with reference methods. The chemiluminescent analyzers consistently underread the true amounts of NO2 in a high-oxygen environment, producing negative concentrations on one instrument. Some monitors that are being clinically utilized to measure NO were designed for industrial and environmental applications in which the ambient oxygen concentrations are less than 21%. In the presence of higher oxygen concentrations, such analyzers can significantly underread the amounts of NO2 that are present, possibly because of reaction quenching or other effects. Measurements of NO and its by-products should be performed using analyzers that have been appropriately tested and calibrated with known concentrations of NO and NO2 prior to their clinical application.

Administration, Inhalation↗

A method for the long-term exposure of rabbits to environmental pollutant gases.

The aims of the present study were twofold. Firstly, we wanted to develop a system for the exposure of rabbits to pollutant gases that would monitor gas concentrations accurately, allow flexibility, be simple to operate, and could be constructed at relatively modest cost. Additionally, we wanted to determine whether the procedures necessary for the daily exposure of young rabbits had any detrimental effect on their development. Using the environmental exposure system that we developed, littermate New Zealand White rabbits, neonatally immunized to either Alternaria tenuis or house dust mite antigen were exposed 2 h daily, from within 24 h of birth until 3 months of age, to either 4 ppm nitrogen dioxide (NO2), or 5 ppm sulphur dioxide (SO2) or ambient air. The environmental exposure system consists of four sections; a stainless steel exposure chamber; an airflow monitoring and control system and gas delivery system; a gas detector and monitoring system; and an exhaust fan. Equilibration and wash-out times of gas were short and the gas mixing within the chamber atmosphere was uniform. Levels of gases were reliably maintained throughout the period of exposure within predetermined limits. The weights of the immunized, gas-exposed animals did not differ significantly from those of the immunized, air-exposed animals at any time throughout the 3 month period of exposure. At 3 months of age, the basal values for lung resistance and dynamic compliance did not differ between gas- and air-exposed rabbits. These values did not differ significantly from those obtained from naive animals of the same age. Our results suggest that we have developed a sensitive, reliable and simple environmental exposure and monitoring system. It is anticipated that the methodology described will allow the careful investigation of the effects of long-term exposure to pollutant gases from birth on the development of airways hyperresponsiveness.

Air Pollutants↗

Maternal exposure to low-level air pollution and pregnancy outcomes: a population-based study.

BACKGROUND: Recent reports have shown that air pollution may increase the risk of adverse birth outcomes. We have evaluated the relationship between ambient air pollution and the occurrence of low birth weight and preterm delivery using routinely collected data in Lithuania. METHODS: This epidemiological study comprised all singleton newborns (N = 3,988), born to women in 1998, who resided in the City of Kaunas. Birth data and information on maternal characteristics were obtained from the Lithuanian National Birth Register. To estimate residential exposure levels, we used measurements of ambient nitrogen dioxide (NO2) and formaldehyde, which were collected at 12 monitoring posts. Multivariate logistic regression was used to estimate the effect that each pollutant would have on low birth weight (LBW) and premature birth while controlling for potential confounders. RESULTS: Adjusted odds ratios (OR) for LBW increased with increasing formaldehyde exposure (OR2nd tertile = 1.86, 95% CI 1.10-3.16; OR3rd tertile = 1.84, 95% CI 1.12-3.03). Adjusted ORs of preterm birth for the medium and high NO2 tertile exposures were OR = 1.14 (95% CI 0.77-1.68) and OR = 1.68 (95% CI 1.15-2.46), respectively. The risk of preterm birth increased by 25% (adjusted OR = 1.25, 95% CI 1.07-1.46) per 10 microg/m3 increase in NO2 concentrations. An analysis by trimester showed that pregnancy outcomes were associated with first-trimester exposure to air pollutants. However, there were no significant relationships in other pregnancy periods between preterm birth and exposure to formaldehyde or between LBW and NO2 exposure. CONCLUSION: Our findings suggest that in the City of Kaunas there might be a relationship between maternal exposure to ambient formaldehyde and the risk of LBW, as well as between NO2 exposure and the risk of preterm birth.

Adult↗

Air pollution and hospital admissions for respiratory and cardiovascular diseases in Hong Kong.

OBJECTIVE: To investigate short term effects of concentrations of pollutants in ambient air on hospital admissions for cardiovascular and respiratory diseases in Hong Kong. METHODS: Retrospective ecological study. A Poisson regression was performed of concentrations of daily air pollutant on daily counts of emergency hospital admissions in 12 major hospitals. The effects of time trend, season, and other cyclical factors, temperature, and humidity were accounted for. Autocorrelation and overdispersion were corrected. Daily concentrations of nitrogen dioxide (NO2), sulphur dioxide (SO2), ozone (O3), and particulate matter < 10 microns in aerodynamic diameter (PM10) were obtained from seven air monitoring stations in Hong Kong in 1994 and 1995. Relative risks (RR) of respiratory and cardiovascular disease admissions (for an increase of 10 micrograms/m3 in concentration of air pollutant) were calculated. RESULTS: Significant associations were found between hospital admissions for all respiratory diseases, all cardiovascular diseases, chronic obstructive pulmonary diseases, and heart failure and the concentrations of all four pollutants. Admissions for asthma, pneumonia, and influenza were significantly associated with NO2, O3, and PM10. Relative risk (RR) for admissions for respiratory disease for the four pollutants ranged from 1.013 (for SO2) to 1.022 (for O3), and for admissions for cardiovascular disease, from 1.006 (for PM10) to 1.016 (for SO2). Those aged > or = 65 years were at higher risk. Significant positive interactions were detected between NO2, O3, and PM10, and between O3 and winter months. CONCLUSIONS: Adverse health effects are evident at current ambient concentrations of air pollutants. Further reduction in air pollution is necessary to protect the health of the community, especially that of the high risk group.

Air Pollutants↗