PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Staphylococcus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Evaluation of rapid coagulase methods for the identification of Staphylococcus aureus.

Four rapid latex agglutination assays, StaphAurex (Wellcome Diagnostics, Research Triangle Park, N.C.), Bacto Staph (Difco Laboratories, Detroit, Mich.), SeroSTAT (Scott Laboratories, Inc., Fiskeville, R.I.), Veri-Staph (Zeus Technologies, Raritan, N.J.), and two hemagglutination tests, Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.) and Hemastaph (Remel, Lenexa, Kans.), were compared with the conventional slide coagulase, tube coagulase (TC), and thermonuclease (TNase) tests for the identification of Staphylococcus aureus. A total of 118 clinical isolates of S. aureus (52 methicillin resistant), 50 S. epidermidis, 5 S. capitis, 2 S. hominis, 3 S. simulans, 6 S. saprophyticus, and 2 S. warneri were tested. The slide coagulase, TC and TNase tests detected 115 (97.5%), 117 (99.2%), and 118 (100%) of the S. aureus isolates, respectively. All showed 100% specificity. The StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph assays correctly identified 117 (99.2%), 117 (99.2%), 116 (98.3%), 110 (93.2%), 108 (91.5%), and 107 (90.7%) of the S. aureus isolates, respectively. For methicillin-resistant S. aureus isolates, StaphAurex, Veri-Staph, Staphyloslide, Hemastaph, SeroSTAT, and Bacto Staph showed 1 (2%), 1 (2%), 2 (4%), 7 (13.5%), 7 (13.5%), and 8 (15.4%) false-negative results, respectively. All the commercial agglutination assays demonstrated false-positive results with strains of S. capitis, S. saprophyticus and S. warneri. The overall accuracy of the commercial agglutination assays compared with TC and TNase ranged from 90.7 to 99.2%. We recommend that negative reactions with the rapid commercial test kits for methicillin-resistant Staphylococcus isolates be confirmed with the TC or TNase test.

Agglutination Tests↗

Detection of methicillin-resistant Staphylococcus epidermidis.

To determine whether methods suggested for detecting methicillin-resistant Staphylococcus aureus apply equally to methicillin-resistant Staphylococcus epidermidis, 135 S. epidermidis isolates were tested by the Vitek AMS gram-positive susceptibility card (Vitek Systems, Inc., Hazelwood, Mo.) and by modifications of agar screen, disk diffusion, and microdilution methods. Modifications included 24- versus 48-h incubation, unsupplemented versus 2% NaCl-supplemented broth, and standard versus direct inoculum. At 24 h, the highest number of resistant strains, 59, was detected by oxacillin (1 microgram) disk diffusion. At 48 h, three additional strains were judged resistant. With one exception, results for oxacillin disk diffusion and agar screen were equivalent at 24 and 48 h. Vitek detected 50 resistant strains. Significantly fewer resistant strains were detected at 24 h by methicillin disk diffusion (5 micrograms) and methicillin microdilution with 2% NaCl. For oxacillin microdilution, neither 2% NaCl supplementation nor the method of inoculum preparation significantly affected the results. Oxacillin microdilution with cation- rather than non-cation-supplemented broth detected significantly fewer (n = 33) resistant strains at 24 h; 51 were resistant at 48 h. To detect methicillin-resistant S. epidermidis, a direct inoculum with either 24-h oxacillin disk diffusion and reincubation of intermediate strains for an additional 24 h or 24-h oxacillin agar screen and reincubation of strains with no growth for a total of 48 h is recommended.

Humans↗

Particle agglutination assays for rapid detection of fibronectin, fibrinogen, and collagen receptors on Staphylococcus aureus.

Latex beads (0.8-micron diameter; Difco Laboratories) were coated with fibronectin, fibrinogen, collagen type I, or denatured collagen (gelatin) and evaluated in a particle agglutination assay (PAA) for the rapid detection of fibronectin, fibrinogen, or collagen binding to Staphylococcus aureus. These assays were compared with a commercial test for detecting the binding of fibrinogen and immunoglobulin G (Staphaurex). Bacterial cells (approximately 10(10) cells per ml) suspended in 0.02 M potassium phosphate buffer (pH 6.8) caused the clumping of standard fibronectin, collagen, gelatin, and fibrinogen latex suspensions within 2 min on glass slides. The test results were scored semiquantitatively from strongly positive ( ) to weakly positive (+) and negative (-) reactions. The negative PAA reactions corresponded to a median value of 11.5% relative to the binding of 125I-labeled protein to strain Cowan 1, indicating the high sensitivity of the test. The reactions with fibronectin and fibrinogen latex suspensions and with Staphaurex were optimal for cells grown on tryptic soy and brain heart infusion broth media. Blood agar was optimal for reactions with collagen and gelatin latex suspensions. Media containing high salts (mannitol salt agar and staphylococcus medium 110) enhanced the tendency of cells to autoaggregate. These assays were also clinically evaluated on 187 S. aureus isolates. The PAA reagents were stable, and the assays were highly specific, sensitive, and reproducible, thus making PAA suitable for the rapid screening of the binding of various bacterial pathogens to serum and connective-tissue proteins.

Animals↗

Pathogenicity in two cases of Staphylococcus schleiferi, a recently described species.

Staphylococcus schleiferi is a new species of coagulase-negative staphylococcus first described in April 1988 (J. Freney, Y. Brun, M. Bes, H. Meugnier, F. Grimont, P. A. D. Grimont, C. Nervi, and J. Fleurette, Int. J. Syst. Bacteriol. 38:168-172, 1988). There are few data in the literature on its pathogenicity. We report two cases in which its role as an opportunistic nosocomial appears to be incontestable.

Cross Infection↗

Reactivity of coagulase-negative staphylococci isolated from cow and goat milk with monoclonal antibodies to Staphylococcus aureus capsular polysaccharide types 5 and 8.

Monoclonal antibodies to Staphylococcus aureus capsular polysaccharide types 5 and 8 were used in an enzyme-linked immunosorbent assay to serotype 74 and 42 coagulase-negative isolates from cow and goat milk, respectively. Eighteen (15.5%) isolates were typable: 13 Staphylococcus haemolyticus, 1 S. hyicus, 1 S. simulans, and 1 S. warneri from bovine origin and 2 S. lentus from caprine origin. Type 5 was predominant, accounting for about 89% of typable isolates. Reactivity with monoclonal antibodies varied considerably according to isolates. The significance and the potential importance of these findings are discussed.

Animals↗

Identification of Staphylococcus species and subspecies with the MicroScan Pos ID and Rapid Pos ID panel systems.

The accuracies of the MicroScan Pos ID and Rapid Pos ID panel systems (Baxter Diagnostic Inc., MicroScan Division, West Sacramento, Calif.) were compared with each other and with the accuracies of conventional methods for the identification of 25 Staphylococcus species and 4 subspecies. Conventional methods included those used in the original descriptions of species and subspecies and DNA-DNA hybridization. The Pos ID panel uses a battery of 18 tests, and the Rapid Pos ID panel uses a battery of 42 tests for the identification of Staphylococcus species. The Pos ID panel has modified conventional and chromogenic tests that can be read after 15 to 48 h of incubation; the Rapid Pos ID panel has tests that use fluorogenic substrates or fluorometric indicators, and test results can be read after 2 h of incubation in the autoSCAN-W/A. Results indicated that both MicroScan systems had a high degree of congruence (greater than or equal to 90%) with conventional methods for the species S. capitis, S. aureus, S. auricularis, S. saprophyticus, S. cohnii, S. arlettae, S. carnosus, S. lentus, and S. sciuri and, in particular, the subspecies S. capitis subsp. capitis and S. cohnii subsp. cohnii. The Rapid Pos ID panel system also had greater than or equal to 90% congruence with conventional methods for S. epidermidis, S. caprae, S. warneri subsp. 2, S. xylosus, S. kloosii, and S. caseolyticus. For both MicroScan systems, congruence with conventional methods was 80 to 90% for S. haemolyticus subsp. 1, S. equorum, S. intermedius, and S. hyicus; and in addition, with the Rapid Pos ID panel system congruence was 80 to 89% for S. capitis subsp. ureolyticus, S. warneri subsp. 1, S. hominis, S. cohnii subsp. urealyticum, and S. simulans. The MicroScan systems identified a lower percentage (50 to 75%) of strains of S. lugdunensis, S. gallinarum, S. schleiferi, and S. chromogenes, although the addition of specific tests to the systems might increase the accuracy of identification significantly.

Autoanalysis↗

DNA polymorphisms in methicillin-susceptible and methicillin-resistant strains of Staphylococcus aureus.

Restriction fragment length polymorphisms in methicillin-susceptible and methicillin-resistant (MRSA) strains of Staphylococcus aureus isolated in the same hospital over a 4-month period were studied by using SmaI and ApaI digestion of genomic DNA and pulsed-field gel electrophoresis. Each of the 20 methicillin-susceptible strains had a unique SmaI pattern, but the 27 MRSA strains showed only seven SmaI patterns. More than half of the SmaI fragments in all of these seven patterns were identical, as were those in the patterns from two unrelated MRSA strains. Digestion with ApaI, which cuts staphylococcus DNA into at least twice as many fragments, confirmed the results obtained with SmaI. Lastly, the plasmid contents of MRSA strains showing identical SmaI and ApaI electrophoretic patterns were not identical. These results are interpreted as supporting the hypothesis that all MRSA strains arose from a single clone and emphasize the need to use several methods in epidemiological investigations of MRSA outbreaks.

Bacterial Typing Techniques↗

Clotting activity in Staphylococcus schleiferi subspecies from human patients.

Staphylococcus schleiferi subsp. schleiferi is a coagulase-negative staphylococcus, usually present as a contaminant in human specimens. A near relative, S. schleiferi subsp. coagulans, possesses coagulase activity but has not been reported from humans. We here describe three isolates of pseudocoagulase-positive S. schleiferi subsp. schleiferi and one isolate of S. schleiferi subsp. coagulans from human patients. The pseudocoagulase from the S. schleiferi subsp. schleiferi isolates differs from S. aureus staphylocoagulase by being sensitive to a combination of protease inhibitors (aprotinin, N-ethylmaleimide, and heparin). These isolates could all easily be confused with S. aureus in a typical clinical laboratory, since they all possess a heat-stable DNase and promote clotting formation. Moreover, S. schleiferi subsp. coagulans produces protein A, and S. schleiferi subsp. schleiferi expresses a clumping factor (fibrinogen affinity factor). Southern blot hybridization with an S. aureus coa-specific probe revealed no sequence related to the coa gene in any of the S. schleiferi isolates, and their riboprobe profiles and biochemical characteristics were typical of S. schleiferi subspecies, not of S. aureus. This study demonstrates that both subspecies of S. schleiferi can promote clotting of rabbit plasma in the standard tube test for coagulase.

Animals↗

Comparison of traditional and molecular methods of typing isolates of Staphylococcus aureus.

Fifty-nine Staphylococcus aureus isolates and 1 isolate of Staphylococcus intermedius were typed by investigators at eight institutions by using either antibiograms, bacteriophage typing, biotyping, immunoblotting, insertion sequence typing with IS257/431, multilocus enzyme electrophoresis, restriction analysis of plasmid DNA, pulsed-field or field inversion gel electrophoresis, restriction analysis of PCR-amplified coagulase gene sequences, restriction fragment length polymorphism typing by using four staphylococcal genes as probes, or ribotyping. Isolates from four well-characterized outbreaks (n = 29) and a collection of organisms from two nursing homes were mixed with epidemiologically unrelated stock strains from the Centers for Disease Control and Prevention. Several isolates were included multiple times either within or between the sets of isolates to analyze the reproducibilities of the typing systems. Overall, the DNA-based techniques and immunoblotting were most effective in grouping outbreak-related strains, recognizing 27 to 29 of the 29 outbreak-related strains; however, they also tended to include 3 to 8 epidemiologically unrelated isolates in the same strain type. Restriction fragment length polymorphism methods with mec gene-associated loci were less useful than other techniques for typing oxacillin-susceptible isolates. Phage typing, plasmid DNA restriction analysis, and antibiogram analysis, the techniques most readily available to clinical laboratories, identified 23 to 26 of 29 outbreak-related isolates and assigned 0 to 6 unrelated isolates to outbreak strain types. No single technique was clearly superior to the others; however, biotyping, because it produced so many subtypes, did not effectively group outbreak-related strains of S. aureus.

Bacterial Typing Techniques↗

Specific detection of methicillin-resistant Staphylococcus species by multiplex PCR.

In Staphylococcus aureus, mecA and femA are the genetic determinants of methicillin resistance. By using a multiplex PCR strategy, 310- and 686-bp regions of the mecA and femA genes, respectively, were coamplified to identify susceptible (lacking mecA) and resistant (mecA+) staphylococci and to differentiate S. aureus (femA+) from coagulase-negative staphylococci (lacking femA). A third staphylococcal genomic sequence, corresponding to IS431 and spanning 444 bp, was used as a PCR control. One hundred sixty-five staphylococcal strains were tested. All 72 methicillin-resistant strains were found to be mecA+, and 92 of the 93 susceptible isolates lacked mecA. Only one coagulase-negative Staphylococcus isolate carrying the mecA gene was highly susceptible to oxacillin. The femA determinant was a unique feature of S. aureus; it was found in 100% of the S. aureus strains tested but was undetectable in all of the coagulase-negative staphylococci tested. The possibility of directly detecting the mecA and femA genes in blood samples was also investigated. After two amplification steps, a sensitivity of 50 microorganisms per ml of freshly collected spiked blood was achieved. In conclusion, coamplification of mecA and femA determinants proved to be very reliable both for rapid detection of methicillin resistance and differential diagnosis between S. aureus and other staphylococci. This technique, which can be successfully performed with blood samples, could be a useful tool in the diagnosis and treatment monitoring of staphylococcal infections.

Bacterial Proteins↗

Multicenter evaluation of arbitrarily primed PCR for typing of Staphylococcus aureus strains.

Fifty-nine isolates of Staphylococcus aureus and a single strain of Staphylococcus intermedius were typed by arbitrarily primed PCR (AP-PCR). To study reproducibility and discriminatory abilities, AP-PCR was carried out in seven laboratories with a standardized amplification protocol, template DNA isolated in a single institution, and a common set of three primers with different resolving powers. The 60 strains could be divided into 16 to 30 different genetic types, depending on the laboratory. This difference in resolution was due to differences in technical procedures (as shown by the deliberate introduction of experimental variables) and/or the interpretation of the DNA fingerprints. However, this did not hamper the epidemiologically correct clustering of related strains. The average number of different genotypes identified exceeded those of the more traditional typing strategies (F. C. Tenover, R. Arbeit, G. Archer, J. Biddle, S. Byrne, R. Goering, G. Hancock, G. A. Hebert, B. Hill, R. Hollis, W. R. Jarvis, B. Kreiswirth, W. Eisner, J. Maslow, L. K. McDougal, J. M. Miller, M. Mulligan, and M. A. Pfaller, J. Clin. Microbiol. 32:407-415, 1994). Comparison of AP-PCR with pulsed-field gel electrophoresis (PFGE) indicated the existence of strains with constant PFGE types but variable AP-PCR types. The reverse (constant AP-PCR and variable PFGE patterns) was also observed. This indicates additional resolution for combined analyses. It is concluded that AP-PCR is well suited for genetic analysis and monitoring of nosocomial spreading of staphylococci. The interlaboratory reproducibility of DNA-banding patterns and the intralaboratory standardization need improvement.

Bacterial Typing Techniques↗

Catheter-related bacteremia associated with coagulase-positive Staphylococcus intermedius.

We report a case of catheter-related bacteremia in a 63-year-old patient caused by Staphylococcus intermedius. Clinical resolution of the infection was obtained after removal of the intravenous device and antibiotic treatment. This observation emphasizes the risk of confusion between S. intermedius and Staphylococcus aureus if only a coagulase test is done.

Bacteremia↗

On the nature and use of randomly amplified DNA from Staphylococcus aureus.

Various DNA-based methods have been introduced to genetically type Staphylococcus aureus strains but not a single technique is universally applicable. In order to search for DNA probes suitable for differentiating strains, randomly amplified polymorphic DNA patterns were generated for 243 S. aureus strains and a single isolate of Staphylococcus intermedius. All fingerprints were examined for unique amplicons, and the nature of 42 of these DNA fragments was investigated. Partial DNA sequences were determined, and several homologies were discovered with known S. aureus sequences (plasmid pSH6 DNA with insertion sequences, agrA and agrB sequences, hld genes, the gene for 23S rRNA, the lysyl tRNA synthetase gene, and the threonyl tRNA synthetase gene) and with genes from other species (Haemophilus influenzae bexA and Bacillus subtilis spoF and ctrA). Thirty fragments were of previously unknown origin. In Southern blots containing Eco RI-digested DNA from S. aureus strains and the S. intermedius strain, nine probes demonstrated the capacity to differentiate strains on the basis of the presence or absence of the sequence element in the staphylococcal genome involved. The remainder of the probes displayed restriction fragment length polymorphisms (n = 12), hybridized in a homogeneously positive fashion (n = 13) or hybridized only with their source strains (n = 8) (four of the latter were specific to S. intermedius). Three of the nine strain-specific probes were overlapping, and two of the others were found to display a high level of inconsistency among epidemiologically related strains. Thus, five strain-specific probes remained that, in a 5-digit typing system, accurately distinguished epidemiologically related and unrelated strains of S. aureus. We conclude that application of strain-specific DNA probes, selected on the basis of differing randomly amplified polymorphic DNA patterns, promises to become a technically simple, robust, and reproducible tool that may significantly facilitate the study of the epidemiology of S. aureus infections.

Bacterial Typing Techniques↗

Vertebral osteomyelitis due to Staphylococcus lugdunensis.

We present the first reported case of vertebral osteomyelitis due to Staphylococcus lugdunensis. The infection occurred in an 80-year-old woman who had been taking glucocorticosteroids. S. lugdunensis is a coagulase-negative staphylococcus with considerable potential as a human pathogen. Isolation of this organism should be regarded as significant unless evidence suggests otherwise.

Aged↗

Human isolates of Staphylococcus caprae: association with bone and joint infections.

Staphylococcus caprae is a coagulase-negative, DNase-positive member of the genus Staphylococcus usually associated with goats, but since 1991 a few laboratories have reported isolating the organism from human clinical specimens. We report on the isolation of 14 strains from human specimens and note that 10 strains were obtained from patients with bone and joint infections. Nine of the 10 infections started with traumatic fractures, and the other was a case of mastoiditis. Seven of these 10 infections were in patients with orthopedic prostheses, which appears to be a risk factor. Three of the 14 strains were from transplant patients. For three of the patients, S. caprae was the only organism isolated. S. caprae may be misidentified because it is not represented in the current MicroScan or Vitek identification systems which are in use in many laboratories, but the organism can be differentiated by a few biochemical tests. S. caprae produces positive results for DNase, pyrrolidonyl aminopeptidase, and acid production from mannitol and maltose; it produces negative results for ornithine decarboxylase and tube coagulase.

Adolescent↗

Comparative performances of six agglutination kits assessed by using typical and atypical strains of Staphylococcus aureus.

Six commercial agglutination tests designed for the identification of Staphylococcus aureus were compared by using a strain collection which included 512 staphylococci representing 33 species (318 isolates of Staphylococcus aureus [including 144 oxacillin resistant], 46 S. epidermidis isolates, 15 S. haemolyticus isolates, 12 S. saprophyticus isolates, 29 S. schleiferi isolates, 30 S. lugdunensis isolates, and 62 other coagulase-negative staphylococci). This group also included a proportion of strains with unusual phenotypes (e.g., 19 coagulase-negative S. aureus isolates, 26 clumping factor-negative S. aureus isolates, and 4 S. aureus isolates each with a double deficiency). The overall sensitivity for identification of typical and atypical S. aureus was high with the Staphaurex Plus test (Murex Biotech) (99.7%), the Pastorex Staph Plus test (Sanofi Diagnostics Pasteur) (99.7%), and the Slidex Staph Plus test (bioMérieux) (100%). The overall rate of specificity was affected by the unusual inclusion in this study of a high proportion of non-S. aureus species, such as S. lugdunensis and S. schleiferi, which express a clumping factor and therefore produce a positive result with the agglutination tests.

Agglutination Tests↗

Sensitivity and specificity of an improved rapid latex agglutination test for identification of methicillin-sensitive and -resistant Staphylococcus aureus isolates.

The performance of a second-generation rapid agglutination kit, Slidex Staph Plus (SSP; bioMérieux), was compared to those of the Slidex Staph (SS; bioMérieux), Staphaurex (SRX; Murex Diagnostics), and BBL Staphyloslide (BBL; Becton Dickinson) kits by using 508 clinical isolates composed of 150 methicillin-sensitive Staphylococcus aureus (MSSA) organisms, 154 methicillin-resistant S. aureus (MRSA) organisms, and 204 non-S. aureus Staphylococcus spp. Of the 508 isolates tested, 75% were fresh clinical isolates, with the remainder taken from five different freezer collections. All four agglutination tests had comparable sensitivities for MSSA and MRSA. However, the SS kit was significantly less specific (93.1%) than the three other tests (P > 0.05, McNemar test). These results demonstrate that the new rapid latex agglutination kit, SSP, was more specific for the identification of S. aureus than the previous version and performed comparably to the SRX and BBL kits.

DNA, Bacterial↗

Soft salt-mannitol agar-cloxacillin test: a highly specific bedside screening test for detection of colonization with methicillin-resistant Staphylococcus aureus.

The early detection of colonization with methicillin-resistant Staphylococcus aureus (MRSA) of patients in intensive-care units is an essential step in the strategy for preventing MRSA epidemics. In this study, tubes containing soft salt-mannitol agar with cloxacillin (6 microg/ml) (SSMAC) were prepared for inoculation of clinical samples at patients' bedsides by personnel of an intensive-care unit. A total of 1,914 swabs from different sample sites of 81 patients were dipped into SSMAC tubes, and after 24 h of incubation (in an incubator located near the intensive-care unit), an evident color change was considered by the intensive-care-unit personnel to be an MRSA alarm. Sixty-three (3.3%) SSMAC tubes were considered positive for MRSA, 1,827 (95.4%) were considered negative, and 24 (1.2%) were considered intermediate. Compared with values for parallel conventional surveillance cultures for MRSA, excluding tubes with intermediate results, the SSMAC test had a sensitivity of 72.7%, a specificity of 99.2%, a positive predictive value of 76.2%, and a negative predictive value of 99.0%. When intermediate tubes were considered positive, the corresponding values were 75.3, 98.2, 63.2, and 99.0%, respectively. The sensitivity and specificity values of the test to identify MRSA-colonized patients were 89.4 and 100%, respectively. Oropharyngeal and naris specimens were the most reliable samples for MRSA detection. False-negative results were frequent in bronchial aspirates with low (< 10(3) to 10(6) CFU/ml) MRSA counts. False-positive results were mainly due to methicillin-resistant Staphylococcus haemolyticus. The SSMAC tube is a useful, rapid, and inexpensive tool for the early identification of MRSA-colonized patients and, consequently, for the implementation of measures to prevent the spread of MRSA.

Adult↗