PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

An amperometric hydrogen peroxide biosensor based on immobilizing horseradish peroxidase to a nano-Au monolayer supported by sol-gel derived carbon ceramic electrode.

A novel strategy for fabricating horseradish peroxidase (HRP)-based H(2)O(2) sensor has been developed by combining the merits of carbon sol-gel supporting matrix and nano-scaled particulate gold (nano-Au) mediator. The thiol functional group-derived carbon ceramic electrode (CCE) was first constructed using (3-mercaptopropyl) trimethoxy silane as sol-gel monomer. Then, the stable nano-Au monolayer was obtained through covalent linkage between nano-Au and thiol group on the surface of CCE. The experimental results showed that nano-Au monolayer formed not only could steadily immobilize HRP but also efficiently retain its bioactivity. Hydrogen peroxide was detected with the aid of hydroquinone mediator to transfer electrons between the electrode and HRP. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as the operating potential, mediator concentration and pH of background electrolyte were explored for optimum analytical performance of the enzyme electrode. The biosensor had a fast response of less than 8 s with linear range of 1.22 x 10(-5) to 1.10 x 10(-3)mol l(-1) and a detection limit of 6.1 x 10(-6)mol l(-1). The sensitivity of the sensor for H(2)O(2) was 0.29 A l mol(-1) cm(-2). The activation energy for enzyme reaction was calculated to be 10.1 kJ mol(-1). The enzyme electrode retained 75% of its initial activity after 5 weeks storage in phosphate buffer at pH 7.

Biosensing Techniques↗

Investigation of novel mediators for a glucose biosensor based on metal picolinate complexes.

The metal complexes [Os(byp)(2)(pic)](+) and [Ru(byp)(2)(pic)](+) where byp is 2,2'-bipyridine and HPic is o-picolinic acid were synthesised and characterised using spectroscopic and electrochemical techniques. These complexes were then evaluated as mediators for a glucose oxidase (GOx)-based biosensor. Results demonstrate the electrocatalytic behaviour of both metal couples towards regeneration of the flavoprotein GOx (FADH(2)) group, when co-immobilised with glucose oxidase. Surface immobilisation was achieved by potential cycling in aqueous solutions of the metal complexes at a glucose oxidase (GOx)/Nafion modified electrode. This proved successful in terms of catalytic efficiency and stability of redox sites. Kinetic parameters associated with both enzymatic and mediator reactions were estimated and the stability/performance properties of the sensor were tested.

Biosensing Techniques↗

Mediated amperometric biosensors for lactic acid based on carbon paste electrodes modified with baker's yeast Saccharomyces cerevisiae.

Carbon paste electrodes modified with baker's yeast Saccharomyces cerevisiae (a source of flavocytochrome b(2)) were investigated as amperometric biosensors for lactic acid. Phenazine methosulphate was used as a mediator. The optimal operational conditions of the electrodes were: an operating potential 0.0 V, solution pH 7.2, concentration of phenazine methosulphate in solution 0.2 mM. A linear range in the dependence of the current responses on the concentration of lactic acid was up to 1 mM. The suitability of the electrodes for determination of lactic acid in milk and dairy products such as kefir and yoghurt was tested. The yeast cells in the paste remained viable at least for 1 month.

Biological Assay↗

The development of a reagentless lactate biosensor based on a novel conducting polymer.

A reagentless lactate biosensor is described, based on an electropolymerized copolymer film poly(5-hydroxy-1,4-naphthoquinone-co-5-hydroxy-3-acetic acid-1,4-naphthoquinone). The quinone group, as part of the polymer backbone, is electroactive and very stable in neutral aqueous medium. It can therefore act as an immobilized mediator for the enzyme recycling, at a working potential much lower than those commonly reported in the literature for other mediators. Experimental conditions for amperometric measurements (temperature, pH) are studied, especially the interference between quinone and molecular oxygen to investigate the enzyme/quinone recycling kinetic. Some well-known interferents are shown to have no measurable effect on the amperometric curves.

Biosensing Techniques↗

Preparation of biosensors by immobilization of polyphenol oxidase in conducting copolymers and their use in determination of phenolic compounds in red wine.

Electrochemically produced graft copolymers of thiophene capped polytetrahydofuran (TPTHF1 and TPTHF2) and pyrrole were achieved by constant potential electrolysis using sodium dodecylsulfate (SDS) as the supporting electrolyte. Characterizations were based on Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). Electrical conductivities were measured by the four-probe technique. Novel biosensors for phenolic compounds were constructed by immobilizing polyphenol oxidase (PPO) into conducting copolymers prepared by electropolymerization of pyrrole with thiophene capped polytetrahydrofuran. Kinetic parameters, maximum reaction rate (V(max)) and Michaelis-Menten constant (K(m)) and optimum conditions regarding temperature and pH were determined for the immobilized enzyme. Operational stability and shelf-life of the enzyme electrodes were investigated. Enzyme electrodes of polyphenol oxidase were used to determine the amount of phenolic compounds in two brands of Turkish red wines and found very useful owing to their high kinetic parameters and wide pH working range.

Biosensing Techniques↗

Direct electrochemistry of glucose oxidase in a colloid Au-dihexadecylphosphate composite film and its application to develop a glucose biosensor.

Colloid Au (Au(nano)) with a diameter of about 10 nm was prepared and used in combination with dihexadecylphosphate (DHP) to immobilize glucose oxidase (GOD) onto the surface of a graphite electrode (GE). The direct electrochemistry of GOD confined in the composite film was investigated. The immobilized GOD displayed a pair of redox peaks with a formal potential of -0.475 mV in pH 7.0 O(2)-free phosphate buffers at scan rate of 150 mV s(-1). The GOD in the composite film retained its bioactivity and could catalyze the reduction of dissolved oxygen. Upon the addition of glucose, the reduction peak current of dissolved oxygen decreased, which could be developed for glucose determination. A calibration linear range of glucose was 0.5-9.3 mM with a detection limit of 0.1 mM and a sensitivity of 1.14 microA mM(-1). The glucose biosensor showed good reproducibility and stability. The general interferences that coexisted in human serum sample such as ascorbic acid and uric acid did not affect glucose determination.

Biosensing Techniques↗

Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples.

The development of a cholesterol biosensor by co-immobilization of cholesterol esterase (ChEt) and cholesterol oxidase (ChOX) on oxygen electrode is described. The electrode consists of gold cathode and Ag/AgCl anode. The enzymes were immobilized by cross-linking with glutaraldehyde and Bovine Serum Albumin (BSA). The immobilized enzymatic membrane was attached to the tip of the electrode by a push cap system. The optimum pH and temperature of the sensor was determined, these are 6 and 25 degrees C respectively. The developed sensor was calibrated from 1-75 mg/dl of cholesterol palmiate and found linear in the range of 2-50 mg/dL. The calibration curve was drawn with V(i) (ppm/min)(initial velocity) vs different concentrations of cholesterol palmiate (mg/dL). The application of the sensor to determine the total cholesterol in different real food samples such as egg, meat was investigated. The immobilized enzymatic layer can be reused over 30 times and the stability of the enzymatic layer was studied up to 9 weeks.

Biosensing Techniques↗

Enhanced detection sensitivity using a novel solid-phase incorporated affinity fluorescent protein biosensor.

We engineered green fluorescent protein (GFP) into affinity fluorescent proteins (aFPs) biosensors. The aFPs detect protein-protein interactions by enhanced fluorescence intensity. In a proof of principle demonstration, aFPs containing haemagglutinin (HA) tag bind specifically to the anti-HA antibody. The sensitivity and specificity is enhanced 28-fold by incorporation of aFPs into solid-phase surface.

Antibodies, Monoclonal↗

An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film.

An amperometric biosensor has been developed for the quantitative determination of urea in aqueous solution. The principle is based on the use of pH-sensitive redox active dissolved hematein molecule. The enzyme, urease (Urs), was covalently immobilized on a conducting copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film, electrochemically prepared onto an indium-tin-oxide (ITO)-coated glass plate. The covalent linkage of enzyme and porous morphology of the polymer film lead to high enzyme loading and an increased lifetime stability of the enzyme electrode. Amperometric response was measured as a function of concentration of urea, at fixed bias voltage of 0.0 V vs. Ag/AgCl in a phosphate buffer (pH 7.0). The electrode gives a linear response range of 0.16-5.02 mM for urea in aqueous medium. The response time is 40 s reaching to a 95% steady-state current value, and 80% of the enzyme activity is retained for about 2 months.

Adsorption↗

Protein interactions with subcutaneously implanted biosensors.

Biofouling of in vivo glucose sensors has been indicated as the primary reason for sensitivity losses observed during the first 24 h after implant [Wisniewski N, Moussy F, Reichert WM. Characterization of implantable biosensor membrane biofouling. Fresen J Anal Chem 2000; 366(6-7): 611-621]. Identification of the biomolecules that contribute to these sensitivity perturbations is the primary objective of the research presented. Active needle-type glucose sensors were implanted in Sprague-Dawley rats for 24h, and then a proteomics approach was used to identify the substances absorbed to the sensors. MALDI-TOF mass spectrometry was the primary tool utilized to identify the biomolecules in sensor leachate samples and species absorbed directly on sensor membranes excised from explanted in vivo sensors. Not surprisingly serum albumin was identified as the primary biomolecule present, however, predominantly as endogenous fragments of the protein. In addition, several other biomolecule fragments, mainly less than 15 kD, were identified. Based on these findings, it is concluded that fragments of larger biomolecules infiltrate the sensor membranes causing diminished glucose diffusivity, thus decreasing in vivo sensitivity.

Adsorption↗

Determination of binary pesticide mixtures by an acetylcholinesterase-choline oxidase biosensor.

In this study, acetylcholinesterase (AChE) and choline oxidase (ChO) were co-immobilized on poly(2-hydroxyethyl methacrylate) (pHEMA) membranes to construct a biosensor for the detection of anti-cholinesterase compounds. pHEMA membranes were prepared with the addition of SnCl(4) to achieve the desired porosity. Immobilization of the enzymes was done by surface attachment via epichlorohydrin (Epi) and Cibacron Blue F3G-A (CB) activation. Enzyme immobilized membrane was used in the detection of anti-cholinesterase activity of aldicarb (AS), carbofuran (CF) and carbaryl (CL), as well as two mixtures, (AS+CF) and (AS+CL). The total anti-cholinesterase activity of binary pesticide mixtures was found to be lower than the sum of the individual inhibition values.

Acetylcholinesterase↗

Comparative study of controlled pore glass, silica gel and poraver for the immobilization of urease to determine urea in a flow injection conductimetric biosensor system.

This study compared the responses of three enzyme reactors containing urease immobilized on three types of solid support, controlled pore glass (CPG), silica gel and Poraver. The evaluation of each enzyme reactor column was done in a flow injection conductimetric system. When urea in the sample solution passed though the enzyme reactor, urease catalysed the hydrolysis of urea into charged products. A lab-built conductivity meter was used to measure the increase in conductivity of the solution. The responses of the enzyme reactor column with urease immobilized on CPG and silica gel were similar and were much higher than that of Poraver. Both CPG and silica gel reactor columns gave the same limit of detection, 0.5 mM, and the response was still linear up to 150mM. The analysis time was 4-5 min per sample. The enzyme reactor column with urease immobilized on CPG gave a slightly better sensitivity, 4% higher than the reactor with silica gel. The life time of the immobilized urease on CPG and silica gel were more than 310h operation time (used intermittently over 7 months). Good agreement was obtained when urea concentrations of human serum samples determined by the flow injection conductimetric biosensor system was compared to the conventional methods (Fearon and Berthelot reactions). These were statistically shown using the regression line and Wilcoxon signed rank tests. The results showed that the reactor with urease immobilized on silica gel had the same efficiency as the reactor with urease immobilized on CPG.

Biosensing Techniques↗

Electrochemical synthesis and impedance characterization of nano-patterned biosensor substrate.

The nano-porous anodic aluminum oxide has been used as a substrate material for enzymatic biosensor operating in aqueous solutions. Nano-scale porous structure was formed by electrical anodization in an acid solution. By changing anodization conditions, such as electrolyte concentration, temperature, and anodization time, the ordered hexagonal porous structure with well-controlled pore size and depth can be obtained. Nano-porous alumina substrate with adsorbed enzymes was used as an enzyme electrode and pH sensor. The pH changes are driven by the enzymatic reactions, e.g. penicillin G hydrolysis to form penicilloic acid in the presence of penicillinaze. The advantage of physical adsorption used to bound penicillinaze, the model enzyme in this work, to the porous structure, is that usually no reagents are required and only a minimum of "activation" or clean-up steps. Adsorption tends to be less disruptive to enzyme proteins than chemical attachment. Due to the increased active sensor area, the immobilization of enzymes has been enhanced, which in turn improved the electrode's sensitivity. To characterize the interactions of enzymes with nano-porous alumina oxide, electrochemical impedance spectroscopy (EIS) was used.

Aluminum Oxide↗

Cholesterol amperometric biosensor based on cytochrome P450scc.

A screen-printed enzyme electrode based on flavocytochrome P450scc (RfP450scc) for amperometric determination of cholesterol has been developed. A one-step method for RfP450scc immobilization in the presence of glutaraldehyde or by entrapment of enzyme within a hydrogel of agarose is discussed. The sensitivity of the biosensor based on immobilization procedures of flavocytochrome P450scc by glutaric aldehyde is 13.8 nA microM(-1) and the detection limit is 300 microM with a coefficient of linearity 0.98 for cholesterol in the presence of sodium cholate as detergent. The detection limits and the sensitivity of the agarose-based electrode are 155 microM and 6.9 nA microM(-1) with a linearity coefficient of 0.99. For both types of electrodes, the amperometric response to cholesterol in the presence of detergent was rather quick (1.5-2 min).

Biosensing Techniques↗

Construction and characterization of novel dual stress-responsive bacterial biosensors.

Using the genes for the green fluorescence protein and Xenorhabdus luminescens luciferase operon and the promoters for the recA and katG genes, two stress-responsive Escherichia coli biosensor strains have been constructed that can individually or concurrently respond to oxidative and genotoxic conditions. Strain DUO-1 carries the pRGDK1 plasmid, which has the recA::GFPuv4 and katG::luxCDABE fusion genes oriented divergently with each other, while in DUO-2, i.e., pRGDK2, they are in a tandem orientation, with the recA promoter showing run-though transcription of the katG::luxCDABE fusion. These two strains and their responses were characterized using several known hydroxyl radical-forming chemicals, e.g., hydrogen peroxide and cadmium chloride, along with some genotoxins, e.g., mitomycin C and methyl-N-nitro-N-nitrosoguanidine, and some general toxicants. Both strains showed an induction of green fluorescent protein (GFP) and bioluminescence when they experienced DNA and oxidative damage, respectively, while the tandem orientation of the two fusion genes within DUO-2 allowed it to also sensitively respond to genotoxins via the production of bioluminescence. However, the characteristics of DUO-2's bioluminescent response to each stress were easily distinguishable, making it useful for the detection of both stresses. Furthermore, tests with mixtures of chemicals showed that both DUO-1 and DUO-2 were responsive when chemicals causing oxidative or genotoxic stress were present as a single chemical or within complex chemical mixtures.

Antibiotics, Antineoplastic↗

A performance comparison of choline biosensors: anodic or cathodic detections of H2O2 generated by enzyme immobilized on a conducting polymer.

Amperometric choline biosensors were fabricated by the covalent immobilization of an enzyme of choline oxidase (ChO) and a bi-enzyme of ChO/horseradish peroxidase (ChO/HRP) onto poly-5,2':5',2"-terthiophene-3'-carboxylic acid (poly-TTCA) modified electrodes (CPMEs). A sensor modified with ChO utilized the oxidation process of enzymatically generated H(2)O(2) in a choline solution at +0.6V. The other one modified with ChO/HRP utilized the reduction process of H(2)O(2) in a choline solution at -0.2V. Experimental parameters affecting the sensitivity of sensors, such as pH, applied potential, and temperature were optimized. A performance comparison of two sensors showed that one based on ChO/HRP/CPME had a linear range from 1.0 x 10(-6) to 8.0 x 10(-5) M and the other based on ChO/CPME from 1.0 x 10(-6) to 5.0 x 10(-5) M. The detection limits for choline employing ChO/HRP/CPME and ChO/CPME were determined to be about 1.0 x 10(-7) and 4.0 x 10(-7) M, respectively. The response time of sensors was less than 5s. Sensors showed good selectivity to interfering species. The long-term storage stability of the sensor based on ChO/HRP/CPME was longer than that based on ChO/CPME.

Alcohol Oxidoreductases↗

Application of the synthetic jet concept to low Reynolds number biosensor microfluidic flows for enhanced mixing: a numerical study using the lattice Boltzmann method.

The concept of macro scale synthetic jets has been applied to the low Reynolds number (Re=10), two-dimensional channel flows which may be found in biosensor microfluidic systems. The current numerical investigation utilizes a hybrid approach of the lattice Boltzmann (LB) method for flow field computations and a finite-difference, convection-diffusion equation for passive scalar transport. The study presents the modified main channel flow results for various wall jet geometries (derived from synthetic jets), jet inlet conditions, scaling issues and Reynolds numbers. The results indicate limited effects due to jet cavity-slot geometry, and that the forced jet imparts momentum to the channel flow thus enhancing fluid mixing.

Biosensing Techniques↗

Calorimetric biosensors with integrated microfluidic channels.

A microfluidic device capable of measuring real-time enthalpy changes of biochemical reactions and thermal properties of biological fluids is presented in this paper. The device consists of a freestanding microthermopile integrated with a glass microfluidic reaction chamber. The p-type polysilicon/gold microthermopiles fabricated on a 2 microm thick thermally isolated membrane showed a sensitivity of 0.94 V/W and a thermal time constant of less than 100 ms. Although the device is not restricted to enzymatic reactions, in this paper measurements of the heat of reaction from the catalytic action of glucose oxidase, catalase, and urease on glucose, hydrogen peroxide, and urea, respectively, are reported. Reactions were performed in open air using liquid batch testing and in enclosed fluidic reaction chamber by continuous flow experiments. A sensitivity of 53.5 microV/M for glucose, 26.5 microV/M for hydrogen peroxide and 17 microV/M for urea was obtained. Detection limit for glucose in the continuous flow mode is approximately 2mM (30 pmol). The aim of this work is to demonstrate the potential of the integrated calorimetric microfluidic device for fundamental thermodynamic studies in biochemical reactions. Using arrays of such devices with immobilized enzymes multi-analyte detection can be accomplished and the effects of interferents from competing substrates can be compensated. This paper presents the design, fabrication and initial testing results from such a microthermopile-based thermal biosensor.

Biosensing Techniques↗