PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

[Intramedullary compression nailing of long tubular bones].

The biomechanical principle of intramedullary compression osteosynthesis is based on the implantation of a movable intramedullary nail that is statically interlocked in distal round holes and dynamically interlocked in a proximal slot. Distraction of the nail against the proximal interlocking screw by means of a compression screw leads to a relative movement of the proximal fragment directed distally against the nail. This results in direct contact of the main fragments under increasing compression. Simple fractures, pseudarthroses and osteotomies within the diaphyses of the long bones represent promising indications for the use of compression nailing. Furthermore, this method enables extraordinarily stable knee and ankle arthrodeses. Major positive aspects are controlled adaptation of fragments and a significantly increased stability of the fracture as compared to conventional intramedullary nailing techniques, especially as rotational forces are concerned. The biomechanical advantages result in earlier full weightbearing and an increased rate of fracture union in delayed healing. Given the use of optimized implants and instruments, compression intramedullary osteosynthesis offers a remarkable potential for further improvement in both the spectrum and success of intramedullary nailing.

Ankle Joint↗

[Vertebroplasty in osteoporotic vertebral compression].

BACKGROUND AND PURPOSE: Osteoporotic vertebral compression fractures are a frequently encountered clinical problem. We aimed to perform a critical, structured review of the current literature and to compare the results with our own experiences. MATERIAL AND METHODS: A structured review of 7 studies about vertebroplasty in osteoporotic compression fractures was performed; each study assessed at least 16 patients and was published in English since 1997. The results were compared to our own experience in 22 patients treated in 2002. RESULTS: Over the past decade, vertebroplasty has increasingly been performed for the treatment of painful osteoporotic vertebral body compression fractures. In good correlation with our own results, all authors reported a significant improvement of pain immediately after treatment and a reduction of pain of up to 90% within 24 h after vertebroplasty. Furthermore, a significant reduction in the use of analgetics and a substantial improvement of functional status has been described in recent studies. In our own evaluation, we were also able to demonstrate a significant improvement of pain after vertebroplasty in 17 of 22 (77%) of our patients. 18 of 22 (82%) patients were able to diminish or even discontinue their analgesic medication. DISCUSSION: Reported results for vertebroplasty have demonstrated a rapid improvement in pain and physical functioning in patients with osteoporotic vertebral compression fractures. Percutaneous vertebroplasty has proven to provide a valuable treatment option for osteoporotic vertebral compression fractures.

Bone Cements↗

Stabilizing effects of ankle bracing under a combination of inversion and axial compression loading.

The combined effects of bracing, axial compression and inversion rotation on the ankle-subtalar complexes were evaluated. Ex vivo tests under the load-controlled condition were performed on six cadaver ankle specimens using a six degree-of-freedom fixture. Inversion rotation was measured while subjecting the ankle-subtalar complex to a 2.5 N-m inversion moment and a combination of the testing variables (brace type, no brace, 178 N axial compression load, no compression load, 0 degrees and 20 degrees of plantar flexion) for a total of 16 tests per specimen. Three commercially available braces (two semirigid types and one lace up type) were evaluated. An axial compression load significantly decreased ankle-subtalar motion in unbraced ankles for the tested inversion moment. The contribution of bracing to stabilization of the ankle was smaller in the axial loading condition than in the no axial loading condition. The semirigid braces had greater stabilizing effects in response to the inversion moment than the lace up brace. Stabilizing effects of bracing were significantly greater in 20 degrees of plantar flexion than in 0 degrees of plantar flexion. The most common mechanism for an ankle sprain injury is inversion rotation on a weight-bearing ankle. Therefore, we should not overestimate stabilizing effects of bracing from evaluations of bracing without axial compression loading.

Adult↗

Prospective nonrandomized trial of manual compression and Angio-Seal and Starclose arterial closure devices in common femoral punctures.

We compared the use of manual compression and Angio-Seal and Starclose arterial closure devices to achieve hemostasis following common femoral artery (CFA) punctures in order to evaluate safety and efficacy. A prospective nonrandomized, single-center study was carried out on all patients undergoing CFA punctures over 1 year. Hemostasis was achieved using manual compression in 108 cases, Angio-Seal in 167 cases, and Starclose in 151 cases. Device-failure rates were low and not significantly different in the two groups (manual compression and closure devices; p = 0.8). There were significantly more Starclose (11.9%) patients compared to Angio-Seal (2.4%), with successful initial deployment subsequently requiring additional manual compression to achieve hemostasis (p < 0.0001). A significant number of very thin patients failed to achieve hemostasis (p = 0.014). Major complications were seen in 2.9% of Angio-Seal, 1.9% of Starclose, and 3.7% of manual compression patients, with no significant difference demonstrated; 4.7% of the major complications were seen in female patients compared to 1.3% in males (p = 0.0415). All three methods showed comparable safety and efficacy. Very thin patients are more likely to have failed hemostasis with the Starclose device, although this did not translate into an increased complication rate. There is a significant increased risk of major puncture-site complications in women with peripheral vascular disease.

Arterial Occlusive Diseases↗

Mud compress therapy for the hands of patients with rheumatoid arthritis.

OBJECTIVE: The aim of this study was to evaluate the efficacy of home treatment with mud compresses for the hands of patients with rheumatoid arthritis (RA). METHODS: Forty-five patients suffering from RA were enrolled in a double-blind, randomized, controlled study. Twenty-two were treated with true mud compresses (treatment group) and 23 were treated with attenuated mud compresses (control group). The compresses were applied in the patients' homes five times a week during a 3-week period. Patients were assessed four times: at baseline, upon completion of the 3-week treatment period, 1 month after the treatment, and 3 months after conclusion of the treatment period. Positive response was defined as reductions of 30% or more in the number of tender and swollen joints, 20% or more in physician global assessment of disease activity, and 20% or more in patient global assessment of the severity of joint pain. RESULTS: In the treatment group, significant reductions in the number of swollen and tender joints and patients' global assessments of pain severity was observed at all post-treatment assessments. Significant improvement in the scores of physician global assessment was seen at the end of therapy and 1 month later. In the control group, no improvement in the number of swollen and tender joints or physician global assessment was found in any post-treatment evaluation. However, a significant reduction in patient global assessment of joint pain severity was reported at the end of therapy and 3 months after concluding treatment. CONCLUSION: Treatment with mud compresses relieves pain affecting the hands and reduces the number of swollen and tender joints in the hands of patients suffering from RA. This treatment can augment conventional medical therapy in these patients.

Arthritis, Rheumatoid↗

Mechanical behavior of calcified plaques: a summary of compression and stress-relaxation experiments.

This paper summarizes the results from mechanical testing of atherosclerotic plaques performed in the Cardiovascular Mechanics Laboratory and the Laboratory for Implantable Materials at UMBC. The motivation for our work is that balloon angioplasty, stenting, and roto-ablation are mechanical processes that are designed to permanently alter the shape of an occluded arterial lumen. The mechanisms of permanent plaque deformation are not known. Therefore, to study the mechanical behavior of plaques, we performed mechanical tests on atherosclerotic lesions with different compositions and investigated differences in the materials' mechanical responses. Atherosclerotic plaque specimens were subjected to two main types of loading: multiple cyclic compression and stress-relaxation. The multiple-cycle test protocol was two fifteen-cycle loading phases that were separated by a 10-15 minute unloaded "rest" period. The compressive stress-relaxation test protocol was a series of three consecutive loadings (called phases I, II, and III). Each phase consisted of a 25% compression that was achieved in less than 1 second, a 10 minute relaxation period, and a 10 minute unloaded "rest" period between loadings. In the multiple cycle compressive loading, plaques exhibited three distinct types of behavior, which corresponded to the plaque compositions. Calcified plaques showed behaviors distinct from other plaque types and healthy vessels. In contrast to the cyclic compression results, plaque types could not be distinguished solely on the basis of stress relaxation behavior. Calcified and fibrous plaques had similar behavior, and therefore histology was used for definite identification. Calcified plaques have unique mechanical properties, and therefore interventions like angioplasty, roto-ablation, and stenting may require protocols specific for calcified lesions. The optimum protocols for calcified plaques may be quite different from plaques with other compositions. It is essential to learn more about the mechanical behavior of all plaque types to increase the success rate of occlusive atherosclerosis treatments.

Angioplasty, Balloon↗

Expression of ubiquitin-like immunoreactivity in axons after compression trauma to rat spinal cord.

The ubiquitin-mediated proteolytic pathway is an important mode of protein degradation in various tissues. Since breakdown of proteins may occur in axons after injury we evaluated the presence of ubiquitin-like immunoreactive material in rat spinal cord following compression injury of mild, moderate and severe degrees at T8-9 level, resulting in no neurological deficit, reversible paraparesis and paraplegia of the hind limbs, respectively. Rats with mild to severe compression injury surviving 1-4 days showed numerous, intensely immunoreactive expanded axons at the site of compression. The labelled axons were randomly distributed in the longitudinal tracts but they were never found in the corticospinal tracts. No labelling was detected by 9 days after injury. In addition, the presence of labelled axons was investigated in the T7 and the T10 segments from rats with moderate compression. No labelling was seen in T7, but in T10 segments many immunoreactive axons were present. Control rats did not show immunoreactive axons in the spinal cord. Neurons of dorsal root ganglia, trigeminal ganglia and of the grey matter of the spinal cord were immunoreactive. Cerebral cortical neurons did not show ubiquitin expression. Thus, compression of the rat spinal cord causes a transient accumulation of ubiquitin-like immunoreactive material in axonal swellings. Even though the dynamics of ubiquitin conjugates are not fully understood, the observed axonal accumulation presumably reflects arrested anterograde axonal transport of protein chiefly derived from neurons of dorsal root ganglia and the local neurons of the spinal cord. The presence of ubiquitin in damaged axons is one prerequisite for degradation of abnormal proteins by the ubiquitin-mediated proteolytic pathway, which may be activated in reactive axonal swellings.

Animals↗

Systemic hypothermia following compression injury of rat spinal cord: reduction of plasma protein extravasation demonstrated by immunohistochemistry.

Systemic hypothermia has neuroprotective effects in experimental models of central nervous system ischemia caused by vascular occlusions. The present study addresses the question as to whether systemic hypothermia can influence the extravasation of plasma proteins following severe spinal cord compression trauma using immunohistochemistry to identify the plasma proteins albumin, fibrinogen and fibronectin. Fifteen rats were assigned to one of three groups and received either thoracic (T) laminectomy or severe spinal cord compression trauma of the T8-9 segment. One group comprised laminectomized animals without compression trauma submitted to a hypothermic procedure in which the core temperature was reduced from 38 degrees to 30 degrees C. The two trauma groups were either submitted to the same hypothermic procedure or kept normothermic during the corresponding time. All animals were killed 24 h following the surgical procedure. The normothermic and hypothermic trauma groups had indications of marked extravasation of albumin, fibrinogen and fibronectin at the site of the injury (T8-9). There was also pronounced extravasation in the cranial and caudal peri-injury zones (T7 and T10) of normothermic injured rats but, with few exceptions, not in the hypothermic ones with the same degree of compression. By measuring the cross-sectional area of the peri-injury zones we found in the hypothermic trauma group a significant reduction of the expansion compared with that present in normothermic injured rats. Our study thus indicates that hypothermia reduces the extravasation of the plasma proteins albumin, fibrinogen and fibronectin following spinal cord compression in the rat. Such a reduction may contribute to neuroprotective effects exerted by hypothermia.

Animals↗

Intermittent pneumatic compression is effective in preventing symptomatic pulmonary embolism after thoracic surgery.

PURPOSE: Postoperative pulmonary embolism (PE) remains a fatal complication even in thoracic surgery. We have used intermittent pneumatic compression for the prophylaxis of postoperative PE since 1998, and herein examined its effectiveness. METHODS: Seven hundred and six patients, whose medical records showed use/no use of pneumatic compression for prophylaxis of PE, underwent general thoracic surgery in our department from December 1995 to December 2000. Their clinical records were reviewed, and variables were compared between patients who experienced clinically apparent PE and patients who did not have PE. RESULTS: Three hundred and forty-four patients did not receive any prophylactic treatment, and 7 of these (2.0%) experienced postoperative PE. Three hundred and sixty-two patients received prophylactic pneumatic compression and none of these developed PE. There was a statistical correlation between the occurrence of PE and the application of pneumatic compression (Chi(2)-test, P = 0.006). Six of the seven patients with PE were operated on in the right decubitus position, and the operative position and the prevalence of PE was also significantly correlated (Chi(2)-test, P = 0.024). Other factors, such as age, sex, operative time, duration until patients became fully ambulatory, body mass index, and character of the disease, did not have significant correlation with the occurrence of PE. CONCLUSIONS: Pneumatic compression was found to effectively prevent postoperative PE. The right decubitus position is considered to be a risk factor for the development of postoperative PE in thoracic surgery.

Aged↗

Biomechanical investigation of the primary stability of intramedullary compression nails in the proximal tibia: experimental study using interlocking screws in cryopreserved human tibias.

The biomechanical properties of the proximal tibia with respect to the application of compressible intramedullary nails were examined in a biomechanical model using human cadaver bones. A reference level was examined histomorphometrically in 24 cryopreserved human tibias. Three series of single or double interlocking fixations were tested at various distances from the tibial plateau. Yield strength, rigidity of the bone stock, maximum load, and compression distances were determined during axial strain. The positioning of the interlocking screws had a considerable influence on maximum load and deformation behavior of the bone. The double interlocking tended to display the best stability in the bone stock, and the distally placed single interlocking method was next best. Failure of the bone stock was observed with significant variations in compression distance and load, with great variations between individual specimens. The stability of the bone stock could not be accurately predicted using such clinical parameters as the patient's age, bone dimensions, radiographic parameters, and bone density. When using a tibial compression nail, the proximal interlocking screw should be placed relatively distal to achieve adequate support. It is possible to apply compression with one proximal interlocking screw under low preload or, preferably, with two interlocking screws.

Adult↗

Conditioned medium of mechanically compressed chick limb bud cells promotes chondrocyte differentiation.

Previous studies have demonstrated that chondrocyte differentiation can be stimulated by cyclic mechanical compression of chick limb bud cell-agarose constructs. This study reveals that medium collected from these compressed cultures promotes chondrocyte differentiation of non-compressed cells to approximately the same extent as compression alone. In micromass cultures of chick limb bud cells, incubation with medium from compressed cells significantly enhanced cell proliferation and the average rate of proteoglycan synthesis in a dose-dependent manner. These findings indicate that the response of undifferentiated chick limb bud cells to mechanical loading involves the secretion of one or more soluble differentiation factors. The chondrogenic activity of the conditioned medium was substantially inhibited by passage through a filter with a nominal molecular-weight cutoff (MWCO) of 10 kDa but not inhibited when using a MWCO of 30 kDa, suggesting that at least one of these factors has a molecular mass between 10 and 30 kDa.

Animals↗

Compression of Secondary Ion Microscopy Image Sets Using a Three-dimensional Wavelet Transformation.

This article proposes a lossy three-dimensional (3-D) image compression method for 3-D secondary ion microscopy (SIMS) image sets that uses a separable nonuniform 3-D wavelet transform. A typical 3-D SIMS measurement produces relatively large amounts of data which has to be reduced for archivation purposes. Although it is possible to compress an image set slice by slice, more efficient compression can be achieved by exploring the correlation between slices. Compared to different two-dimensional (2-D) image compression methods, compression ratios of the 3-D wavelet method are about four times higher at a comparable peak signal-to-noise ratio (PSNR).

Journal Article↗

A direct compression stimulator for articular cartilage and meniscal explants.

This paper describes the development and use of a direct compression stimulator for culturing explants from the meniscus of the knee and articular cartilage. Following design and fabrication of the instrument along with its data acquisition system, the function of the machine was verified by both mechanical means and tissue effect. The loading chamber can hold up to 45 5 mm diameter samples. While designed to stimulate samples up to 4 mm thick, axial displacements as little as 0.127 microm are within the theoretical capacity of the stimulator. In gene expression studies, collagen II and aggrecan expression were examined in explants from articular cartilage as well as medial and lateral menisci subjected to dynamic stimulation and static compression. These results were then compared to free swelling samples. It was found that static compression to cut thickness down-regulated aggrecan and collagen II expression in articular cartilage explants compared to free swelling controls by 94% and 90%, respectively. The application of a dynamic, intermittent, 2% oscillation around the cut thickness returned expression levels to those of free swelling controls at 4 h but not at 76 h. In medial meniscus samples, dynamic compression up-regulated aggrecan expression by 108%, but not collagen II expression, at 4 and 76 h compared to static controls. No difference in gene expression was observed for lateral meniscal explants. Thus, effects of direct compression seen in articular cartilage may not necessarily translate to the knee meniscus. The design of this stimulator will allow a variety of tissues and loading regimens to be examined. It is hoped that regimens can be found that not only return samples to the production levels of free swelling controls, but also surpass them in terms of gene expression, protein synthesis, and functional properties.

Aggrecans↗

The relative contributions of compression and hypoxia to development of muscle tissue damage: an in vitro study.

Deep pressure ulcers develop in tissues subjected to sustained mechanical loading. Though it has been hypothesized that this damage mechanism results from local tissue ischemia, it has recently been shown with a cell model that sustained compression can cause cell deformation, leading to tissue breakdown. The present study focuses on the assessment of cell viability during compression and ischemia in an in vitro muscle model to determine their relative contributions to damage development. A model system was developed consisting of engineered skeletal muscle produced from the culture of murine muscle cells in a collagen gel. The tissue was subjected to 0, 20, or 40% compression under hypoxic or normoxic conditions. Experiments were performed on the stage of a microscope and cell viability was monitored using fluorescent markers for apoptotic and necrotic cell death. Hypoxia did not lead to significant cell death over a 22 h period. By contrast, compression led to immediate cell death that increased with time. No additional effect of hypoxia on cell death was observed. These data show that contrary to existing theories, compression can cause development of muscle damage and that hypoxia does not contribute to cell death development within 22 h in engineered muscle.

Animals↗

Change in electrocardiogram T-wave amplitude during umbilical cord compression is predictive of fetal condition in sheep.

OBJECTIVE: The purpose of this study is to assess the usefulness of the dynamic change in T/QRS ratio in fetal electrocardiograms in predicting the fetal condition when repetitive variable decelerations are seen in intrapartum cardiotocograms. STUDY DESIGN: We investigated the relationship, using linear regression and Wilcoxon's test, between T/QRS and blood gas values, catecholamine concentrations, and blood pressure during repetitive cord compression in five chronically instrumented lamb fetuses. RESULTS: T/QRS during cord compression correlated significantly (p less than 0.01) with fetal arterial pH (r = -0.7711), norepinephrine concentration (r = 0.7551), and duration of elevated blood pressure during compression (r = -0.8619). Fetal arterial pH and base excess were lower, the duration of elevated blood pressure during compression was shorter, and carbon dioxide partial pressure and catecholamine concentrations were higher in the stage with higher (greater than 0.50) T/QRS during compression (p less than 0.005). CONCLUSION: We can estimate the severity of fetal distress by measuring T/QRS near the bottom of the decelerations.

Animals↗

Elastic compression in the prevention of venous stasis. A critical reevaluation.

The effect of elastic compression on venous flow in the legs provided by carefully fitted stockings has been measured by a venographic technic. The stocking used provides a gradually decreasing compression from ankle to groin. Clearance of stagnant blood from behind venous valves is clearly improved and the differences observed are statistically highly significant. These data suggest that the routine use of carefully fitted compression stockings will result in a decreased incidence of deep vein thrombosis (DVT) and provide a singularly safe, convenient, and noninvasive method of prophylaxis. Evidence presented suggests that at least two investigators have failed to show a decreased incidence of DVT in limbs subjected to elastic compression because the method of compression was inadequate .

Adult↗

A scanning electron-microscopic study of in vitro abrasion of mammalian tooth enamel under compressive loads.

Microscopic tooth-wear (microwear) patterns can be an important tool for assessing modes and rates of abrasive tooth wear, but their analysis and interpretation is complicated by the fact that microwear is influenced by many factors. Three of these factors were here tested under conditions of compressive loading: (1) species differences in enamel structure, (2) abrasive particle size and (3) magnitude of force. Teeth of four species (Homo sapiens, Lemur fulvus, Ovis aries and Crocodylus rhombifer) were abraded in vitro using three sizes of abrasive silicon-carbide grit (average diameters 73, 23 and 14 microns), at two loads (50 and 100 kg). Microwear features were assessed by scanning electron microscopy of lightly etched enamel surfaces and epoxy replicas. Microwear pits (length:width < 4:1) were the predominant feature type. Factorial analysis of variance of rank-transformed, feature-area measurements demonstrated that, under conditions of compressive loading, the size of abrasive particles was the primary determinant of microwear size. These results contrast with previous experimental tests of abrasion by predominantly shearing loads, where feature size was influenced by interaction among experimental factors, including the microscopic orientation of enamel crystallites. Although magnitude of compressive force was not a factor in microwear size variation, it may be a critical factor in explaining the presence or absence of microwear on tooth surfaces. The relatively small compressive bite force generated during typical chewing may not consistently produce abrasive pitting. These experiments demonstrate that, as the same abrasive regime can produce both large and small pits, the mechanism by which wear features are formed (i.e. compression or adhesion) cannot be determined from the size of features alone. Nevertheless, the dependence of pit size on abrasive particle size demonstrates that metrical variation in wear features can elucidate important attributes of an animal's diet.

Alligators and Crocodiles↗

The first cleavage plane and the embryonic axis are determined by separate mechanisms in Xenopus laevis. II. Experimental dissociation by lateral compression of the egg.

In eggs of Xenopus laevis, the meridian of sperm entry (SEP meridian), the direction of subcortical rotation, and the first cleavage furrow have been used to predict, with varying degrees of accuracy, the position of the plane of bilateral symmetry of the embryo. We show here that altering the shape of the uncleaved egg by lateral compression disrupts some of these topographical relationships in a reproducible way. The neural groove, which identifies the embryonic dorsal midline, usually forms at either of the two narrow ends of the compressed egg, regardless of the position of the SEP meridian, whereas the first cleavage furrow divides the compressed egg across its shorter dimension, regardless of the position of the SEP meridian. Thus the positions of the SEP meridian, the cleavage plane, and the embryonic bilateral plane can be completely uncoupled from each other. In contrast, the direction of subcortical rotation is usually parallel to the plane of compression and predicts the position of the neural groove in all cases. Since the direction of subcortical rotation and the plane of bilateral symmetry still correlate under conditions of compression, we conclude that subcortical rotation is the crucial early step in the process of axis specification.

Animals↗