PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped within a poly(thionine) film.

Preparation of semiconducting films by electropolymerisation of a monomer which is itself a redox mediator is an attractive and simple method for biosensor fabrication. A polymeric film of the redox dye thionine (phenothiazine) enables the stable immobilisation of polyphenol oxidase (tyrosinase) while acting as mediator for the enzymatic process. The immobilisation method is based on an inner crosslinked tyrosinase layer which contains thionine with an electropolymerised film of poly(thionine) on top. This method gave the most stable redox couple for poly(thionine) and exhibited the greatest response stability. The sensor was tested using a range of synthetic oestrogens and phenolic compounds, which are suspected endocrine disruptors/oestrogen mimics. The device responded well to all compounds tested with limits of detection ranging from 1 to 23 microM (based on three times S/N ratio). The tyrosinase/poly(thionine) electrode response to phenol was 3 orders of magnitude greater than the unmediated response in the absence of poly(thionine).

Biosensing Techniques↗

A new film for the fabrication of an unmediated H2O2 biosensor.

A novel and stable film made from polyethylene glycol (PEG) on pyrolytic graphite (PG) electrode was presented in this paper for incorporating horseradish peroxidase (HRP) to study the direct electrochemistry of the enzyme. In PEG film, HRP showed a thin-layer electrochemistry behavior. The apparent standard potential (E degrees ') was -0.379 V versus SCE at pH 7.2. Moreover, the PEG-HRP modified electrode exhibited excellent electrocatalytical response to the reduction of H2O2 with a calibration range between 2.0 x 10(-6) and 6.0 x 10(-4) M and a good linear relation from 2.0 x 10(-6) to 1.0 x 10(-4) M, on which an unmediated H2O2 biosensor was based. The detection limit of 6.7 x 10(-7) M was estimated when the signal-to-noise ratio was 3. The relative standard deviation (R.S.D.) was 4.7% for six successive determinations at a concentration of 4.0 x 10(-5) M. The apparent Michaelis-Menten constant (Km app) of the sensor was found to be 1.38 mM. Epinephrine, dopamine, and ascorbic acid did not interfere with the sensitive determination of H2O2.

Biosensing Techniques↗

A new approach for the detection of DNA sequences in amplified nucleic acids by a surface plasmon resonance biosensor.

In this paper, a simple and useful approach for DNA sensing based on surface plasmon resonance (SPR) transduction is reported. A new DNA sample pre-treatment has been optimised to allow fast and simple detection of hybridisation reaction between a target sequence in solution and a probe immobilised on the sensing surface. This pre-treatment consisted in a denaturation procedure of double stranded DNA containing the target sequence and was based on an high temperature treatment (95 degrees C, 5 min) followed by a 1 min incubation with small oligonucleotides. The oligonucleotides are designed to prevent the re-hybridising of the denatured strands, while enabling the target sequence to bind the immobilised probe. The important parameters of the procedure, i.e. incubation time, length and concentration of the oligonucleotides, have been studied in detail. The optimised DNA denaturation procedure has been successfully applied to the detection of amplified DNA with a commercially available SPR biosensor (Biacore X). DNA samples extracted from plant and human blood were tested after amplification by polymerase chain reaction (PCR).

Apolipoproteins E↗

Lactose biosensor based on Langmuir-Blodgett films of poly(3-hexyl thiophene).

An amperometric lactose biosensor was developed by immobilizing lactase (EC 3.2.1.23) and galactose oxidase (GaO) (EC 1.1.3.9) in Langmuir-Blodgett (LB) films of poly(3-hexyl thiophene) (P3HT)/stearic acid (SA) for estimation of lactose in milk and its products to prevent "lactose intolerance". The enzyme immobilized LB film was used as working electrode and platinum as reference electrode. The enzyme electrodes show a linearity 1-6 g/dL of lactose and have a shelf life more than 120 days. The reusability of electrode was found ten times with 3% loss in current response. The enzyme electrode was characterized by Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and kinetic parameters such as pH, temperature and stability. The working electrode may be used for the estimation of lactose/galactose in food and biological fluids.

Animals↗

Comparative investigation between acetylcholinesterase obtained from commercial sources and genetically modified Drosophila melanogaster: application in amperometric biosensors for methamidophos pesticide detection.

Genetically modified acetylcholinesterase (AChE) from Drosophila melanogaster (dm) and from commercial sources, Electric eel (ee), Bovine erythrocites (be) and Human erythrocites (he), were investigated as biological receptors for the detection of methamidophos pesticide based on inhibition studies. Most engineered variant of AChE from dm showed enhanced sensitivity toward methamidophos pesticide. Among 24 dmAChE variants tested, 12 presented a sensitivity comparable to the commercially available eeAChE, but higher than AChEs from be and he. Four were found more sensitive and six others were insensitive to methamidophos insecticide. The D375G,Y370F,Y374A,F376L mutant was the most sensitive, with a ki value of 2.2 X 10(6) mol(-1) L min(-1), three orders of magnitude higher than eeAChE (1.1 X 10(3) mol(-1) L min(-1)). The sensor constructed with genetically modified enzyme showed better characteristics with respect to detection limit and sensitivity compared with those using commercial eeAChE. Differential pulse polarography and chronoamperometry were used as electrochemical techniques to characterize the AChE biosensors. The lower detection limit of 1 ppb was obtained with D375G,Y370F,Y374A,F376L mutant of dmAChE, compared to 90 ppb for the commercial eeAChE. This study may stimulate scientists to develop more sensitive and selective procedures for organophosphorus insecticides detection by using engineered variant of dmAChE.

Acetylcholinesterase↗

Palladium hexacyanoferrate hydrogel as a novel and simple enzyme immobilization matrix for amperometric biosensors.

An amperometric glucose biosensor with glucose oxidase (GOx) immobilized into palladium hexacyanoferrate (PdHCF) hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate (NiHCF) electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer, the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH 5.0 and E = -0.075 V versus calomel (3.0 M KCl) reference electrode), sensor showed high sensitivity to glucose (0.3-1.0 microA/mM) and a response time of less than 30s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode and 0-7.0 mM in FIA. During the 32 days testing period, no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.

Biosensing Techniques↗

Scanning electrochemical microscopy for detection of biosensor and biochip surfaces with immobilized pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase as enzyme label.

Scanning electrochemical microscopy (SECM) was applied to study quinoprotein-based biosensor or biochip. A typical quinoprotein, pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase (GDH), was taken as example. Feedback mode and generation collection (GC) mode in SECM have been explored in imaging the catalytic activity of GDH on microscopic magnetic bead domains. Biotinylated GDH was immobilized by using streptavidin-coated paramagnetic microbeads, which were deposited as microspot on a hydrophobic surface. Ferrocenemethanol and ferricyanide were used as electron mediators for feedback and GC detection, respectively. Enzymatic catalysis was further studied quantitatively using the theory developed for SECM.

Biosensing Techniques↗

A novel biosensor for mercuric ions based on motor proteins.

We explored the potential of contractile proteins, actin and myosin, as biosensors of solutions containing mercuric ions. We demonstrate that the reaction of HgCl2 with myosin rapidly inhibits actin-activated myosin ATPase activity. Mercuric ions inhibit the in vitro analog of contraction, namely the ATP-initiated superprecipitation of the reconstituted actomyosin complex. Hg reduces both the rate and extent of this reaction. Direct observation of the propulsive movement of actin filaments (10 nm in diameter and 1 microm long) in a motility assay driven by a proteolytic fragment of myosin (heavy meromyosin or HMM) is also inhibited by mercuric ions. Thus, we have demonstrated the biochemical, biophysical and nanotechnological basis of what may prove to be a useful nano-device.

Biosensing Techniques↗

Theoretical and experimental study towards a nanogap dielectric biosensor.

Theoretical and experimental studies of nanogap capacitors as potential label free biosensors are presented. The nanogap device is capable of detecting the existence of single stranded DNA (ssDNA) oligonucleotides (20-mer) in 100 nM aqueous solutions using a 20 nm gap of 1.2 pl in volume. While the dielectric properties of DNA solution have been widely investigated, early approaches are limited at low frequency by the parasitic noise due to the electrical double layer (EDL) impedance. Nanogap electrodes have the potential to serve as biomolecular junctions because their size (5-100 nm) minimizes electrode polarization effects regardless of frequency. In this paper, we modeled the effects of the EDL interaction between two parallel nanogap electrodes by solving the Poisson-Boltzmann (PB) equation for equilibrium state. When the gap size is smaller than the EDL thickness, the dependence of the nanogap capacitance on the ionic strength is insignificant. This is critical in using the capacitance change as an indicator of the existence of target molecules. The predicted capacitance of nanogaps filled with various ionic strength electrolytes was in quantitative agreement with the experimental measurements. The various concentrations of the target molecules in nanogap sensor were characterized. A capacitance change of a 20 nm x (10)1.5 microm x 4mm gap from 3.5 to 4.1 nF at 200 Hz was recorded between deionized water (DI) and 100 nM ssDNA solution (about 70,000 molecules inside the gap for equilibrium state).

Biosensing Techniques↗

Liquid phase SPR imaging experiments for biosensors applications.

Surface plasmon resonance (SPR) has recently gained attention as a label-free method for the detection of biological molecules binding onto functionalised surfaces. It is one of the most sensitive detection method for monitor variations in the thickness and refractive index in ultra-thin films. Here, the adsorption processes of oligonucleotides onto gold substrates have been investigated in aqueous buffer solution using SPR imaging measurements. The hybridization of a thiol-modified, single stranded oligonucleotide anchored to a gold surface via thiol group, with its complementary sequence has been observed and characterised monitoring the hybridization process by SPR equipment. In situ investigation of smallest changes in SPR imaging measurements dynamically performed in liquid phase in the presence of DNA complementary probes was performed. Infrared spectroscopy and scanning electron microscopy characterisation of the functionalised gold surfaces of the biosensor were compared with the images obtained by SPR experimental apparatus.

Biosensing Techniques↗

Towards the protein phosphatase-based biosensor for microcystin detection.

A colorimetric test for the detection of microcystins based on immobilised protein phosphatase (PP) has been developed. A PP2A produced by molecular engineering has been used and its performance has been compared to those of commercial PP2A and PP1. Covalent immobilisation of the enzyme using glutaraldehyde, encapsulation by sol-gel and entrapment with photocrosslinkable poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) have been compared, the latter method providing the highest immobilisation yields. Screen-printed carbon electrodes (SPEs), Maxisorp microtiter wells and Ultrabind modified polyethersulfone affinity membranes have been used as immobilisation supports. Whilst the highest immobilisation yields were obtained with microtiter wells, the highest operational and storage stabilities were achieved with carbon SPEs and membranes, respectively. The immobilisation of PP by PVA-SbQ provided a means to preserve the enzymatic activity, which decreased at fast rates when the enzyme was kept in solution. The colorimetric test using p-nitrophenyl phosphate has demonstrated that the immobilised enzyme is able to recognise both microcystin variants (MC-LR and MC-RR), although optimisation work should be performed to achieve appropriate limits of detection. With the purpose to develop an electrochemical biosensor, several phosphorylated substrates have been used. Promising results have been achieved with the commercial enzymes and alpha-naphtyl phosphate, p-aminophenol phosphate and catechol monophosphate as enzyme substrates, guaranteeing the viability of the electrochemical approach.

Biosensing Techniques↗

Specific targeting of ultrasound contrast agent (USCA) for diagnostic application: an in vitro feasibility study based on SAW biosensor.

The present study described a new strategy to examine the interaction between the targeted ultrasound contrast agent (USCA) and its target under flow conditions with a surface acoustic wave (SAW) transducer. The sensing principle is based on the measurement of the phase change on the sensing element upon the binding of specific biomolecules. Love-wave biosensor array was consisting of sensor elements and reference elements. The sensor elements have been prepared by coating the sensor surface with tumor marker EDB-fibronectin by means of SAM technique and carbodiimide chemistry. Reference elements were left blank or coated with fibronectin and used to eliminate thermal drift, unspecific binding, and turbulence from injection of liquids by calculating the differential phase shift with respect to the sensor elements. The binding of targeted USCA to the sensor surface was constantly recorded by monitoring the phase shift on the sensor element. The binding of targeted USCA generated a high phase shift on the sensor elements, but almost no change on the reference elements. Control experiments using non-targeted and isotype-targeted USCA confirmed the specificity of binding due to anti-EDB-fibronectin scFv-antibody-fragment-EDB-fibronectin antigen interaction. The suitability of the SAW technique to monitor the specific binding behavior of targeted micron-sized USCA in real time has been well established.

Biosensing Techniques↗

Acetylecholinesterase-based biosensor electrodes for organophosphate pesticide detection. II. Immobilization and stabilization of acetylecholinesterase.

The dry and wet stability of Drosophila acetylcholinesterase non-covalently immobilized onto polyethyleneimine modified screen-printed carbon electrodes was improved when compared to non-immobilized acetylcholinesterase, and acetylcholinesterase covalently immobilized onto dialdehyde and polyethyleneimine modified electrodes. Stabilizer mixtures were characterized for additional stabilization of acetylcholinesterase during storage in the dry state, with dextran-sulphate/sucrose and polygalacturonic acid/sucrose mixtures proving highly effective for long-term storage of biosensor electrodes.

Acetylcholinesterase↗

A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode.

Electrodeposition was used for the co-deposition of glucose oxidase (GOx) enzymes and palladium nanoparticles onto a Nafion-solubilized carbon nanotube (CNT) film. The co-deposited Pd-GOx-Nafion CNT bioelectrode retains its biocatalytic activity and offers an efficient oxidation and reduction of the enzymatically liberated H2O2, allowing for fast and sensitive glucose quantification. The combination of Pd-GOx electrodeposition with Nafion-solubilized CNTs enhances the storage time and performance of the sensor. An extra Nafion coating was used to eliminate common interferents such as uric and ascorbic acids. The fabricated Pd-GOx-Nafion CNT glucose biosensor exhibits a linear response up to 12 mM glucose and a detection limit of 0.15 mM (S/N = 3).

Biosensing Techniques↗

Analysis of calibration methodologies for solvent effects in drug discovery studies using evanescent wave biosensors.

Recent improvements in sensitivity have enabled direct binding studies of small molecules with evanescent wave biosensors, which monitor binding by measuring refractive index changes close to the sensing surface. The universal solvent for small molecules, dimethylsulfoxide has a high refractive index; consequently, on ligate addition a large non-specific solvent effect is seen which can mask the specific signal. It has been previously noted that different sensor surfaces can respond differently to the same buffer change. The difference is proposed to arise from differences in buffer space and contraction and swelling of the surface hydrogel. Within this paper, a number of calibration approaches are investigated and tested using warfarin binding to human serum albumin as a model system. A number of recommendations are made for accurate referencing for non-specific effects. Changes to the ionic strength of the running buffer had little effect, whilst changes to the charge density of the carboxylmethyl dextran significantly affected how well the control surface reflects the non-specific signal. An amended 'calibration method' can be used, however, it is an additional complex step that was found to overcorrect in the presence of non-specific binding. Matching immobilisation levels between control and active surface significantly reduces solvent differences allowing accurate correction providing solvent compositional changes are minimised in experimental design. Under these circumstances, the traditional method of simple subtraction of the control from the active response is the most appropriate method of correction.

Biosensing Techniques↗

Real-time optical biosensor based on differential phase measurement of surface plasmon resonance.

We report a real-time differential phase measurement technique which can be implemented in optical surface plasmon resonance biosensors. The important feature of our design is that sensitivity has been greatly improved by measuring the differential phase change between the s and p-polarizations. Real-time measurement capability is achieved by using a phase extracting routine which continuously monitors the waveforms captured by two photo-detectors. Measurement capability of our setup is demonstrated through real-time monitoring of bovine serum albumin (BSA)/anti-BSA binding reaction. The estimated sensitivity of our current setup is 7.4 ng/ml.

Biosensing Techniques↗

Structured thin films as functional components within biosensors.

This review provides an introduction to the field of thin films formed by Langmuir-Blodgett or self-assembly techniques and discusses applications in the field of biosensors. The review commences with an overview of thin films and methods of construction. Methods covered will include Langmuir-Blodgett film formation, formation of self-assembled monolayers such as gold-thiol monolayers and the formation of multilayers by the self-assembly of polyelectrolytes. The structure and forces governing the formation of the materials will also be discussed. The next section focussed on methods for interrogating these films to determine their selectivity and activity. Interrogation methods to be covered will include electrochemical measurements, optical measurements, quartz crystal microbalance, surface plasmon resonance and other techniques. The final section is dedicated to the functionality of these films, incorporation of biomolecules within these films and their effect on film structure. Species for incorporation will include antibodies, enzymes, proteins and DNA. Discussions on the location, availability, activity and stability of the included species are included. The review finishes with a short consideration of future research possibilities and applications of these films.

Biosensing Techniques↗

Continuous measurements of a binding reaction using a capacitive biosensor.

A capacitive biosensor with polyclonal antibodies raised against human serum albumin (HSA) immobilized on a gold transducer has been developed for continuous measurement of HSA in the muM-range. A mathematical model has been refined to describe integral HSA-binding curves assuming that (i) binding is essentially irreversible under the conditions used, (ii) the signal is scaled as the number of non-occupied binding sites and (iii) the rate of disappearance of available binding sites is scaled as the number of available binding sites and analyte concentration in solution. Deconvolution of the curves using the mathematical model indicates clearly that it is possible to retrieve concentration profiles (isocratic, linearly or exponentially increasing gradients) of the analyte in the continuous sample flow from the normalized integral binding (NIB) curves. The data presented constitutes the theoretical background and the first step towards the development of an analytical system allowing on-line detection of the concentration profile of the analyte from NIB-curves. Since the system can be used for extended time periods between regeneration steps, a low frequency of regeneration steps can be expected.

Antibodies↗