PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERIC PRESSURE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Analysis of artemisinin by a packed-column supercritical fluid chromatography-atmospheric pressure chemical ionisation mass spectrometry technique.

A packed-column supercritical fluid chromatography-atmospheric pressure chemical ionisation mass spectrometry method was studied for the determination of artemisinin from Artemisia annua L. extracts. The technique does not require any kind of derivatisation prior to the analysis. All samples were simply dissolved in methanol and injected into the mobile phase. Detection was achieved by using mass spectrometry with atmospheric pressure chemical ionisation. The ionisation technique is relatively soft and provides protonated molecular ion and informative structural fragmentation for the compound. Benzophenone was used as a chromatographic standard for the determination of the analytical reproducibility. The supercritical carbon dioxide mobile phase used in the system was modified by 10% methanol. The average absolute retention time was 3.54 min with a standard deviation of 0.017 min and a relative standard deviation of 0.4% with respect to benzophenone for the procedure. The correlation coefficient was 0.998 and detection limit 370 pg on column.

Anti-Infective Agents↗

Determination of ergosterol in Fusarium-infected wheat by liquid chromatography-atmospheric pressure photoionization mass spectrometry.

A rapid liquid chromatography-atmospheric pressure photoionization mass spectrometry (LC-APPI-MS) method was developed for the determination of ergosterol in wheat grains. The effects of the dopants acetone, toluene and anisole on the ionization efficiency were studied. To identify the predominant ions, APPI-MS-MS studies were performed. Different LC and MS parameters were optimized to obtain maximum sensitivity. The effects of the mobile phase composition and of the flow rate were investigated. Additionally, the effects of the nebulizer gas pressure, the drying gas flow, the vaporizer temperature, the fragmentor voltage and the capillary voltage on the ionization efficiency were evaluated. The calibration curve exhibited good linearity and reproducibility. The detection limit (S/N=3) was 0.15 ng on column, which allows the determination of ergosterol in wheat at a concentration as low as 0.12 microg/g. Twenty wheat varieties artificially infected with Fusarium graminearum were investigated by this method.

Atmospheric Pressure↗

Atmospheric pressure chemical ionization mass spectrometry for analysis of lipids.

Atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) has proven to be a very valuable technique for analysis of lipids from a variety of classes. This instrumental method readily produces useful ions with gentle fragmentation from large neutral molecules such as triacylglycerols and carotenoids, which are often difficult to analyze using other techniques. Molecules that are easily ionized, such as phospholipids, produce molecular ions and diagnostically useful fragment ions that are complementary to those produced by methods such as electrospray ionization MS with collision-induced dissociation. The simplicity and versatility of APCI-MS make it an ideal tool for use in solving hitherto very difficult analytical problems.

Animals↗

Screening, library-assisted identification and validated quantification of oral antidiabetics of the sulfonylurea-type in plasma by atmospheric pressure chemical ionization liquid chromatography-mass spectrometry.

An atmospheric pressure chemical ionization liquid chromatographic-mass spectrometric (APCI-LC-MS) LC-MS assay is presented for fast and reliable screening and identification as well as precise and sensitive quantification of oral antidiabetics of the sulfonylurea-type (OADs) in plasma. It allowed the specific diagnosis of an overdose situation or a Munchausen syndrome caused by ingestion of OADs. After liquid-liquid extraction, the OADs glibenclamide, glibornuride, gliclazide, glimepiride, glipizide, gliquidone, glisoxepide, tolazamide and tolbutamide were separated using fast gradient elution. After screening and identification in the scan mode using our new LC-MS library, the OADs were quantified in the selected-ion mode. The quantification assay was validated according to the criteria established by the Journal of Chromatography B. All validation data were inside the required limits. The assay is part of a general LC-MS procedure for fast screening, identification and quantification of different toxicologically relevant compounds in plasma and has proven to be appropriate for OADs.

Administration, Oral↗

Screening, library-assisted identification and validated quantification of fifteen neuroleptics and three of their metabolites in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization.

A liquid chromatographic/mass spectrometric assay with atmospheric pressure chemical ionization (APCI-LC/MS) is presented for the fast and reliable screening and identification and for the precise and sensitive quantification of 15 neuroleptic (antipsychotic) drugs and three of their relevant metabolites in plasma. It allows confirmation of the diagnosis of a neuroleptic overdose and monitoring of psychiatric patients' compliance. The neuroleptics amisulpride, bromperidol, clozapine, droperidol, flupenthixol, fluphenazine, haloperidol, melperone, olanzapine, perazine, pimozide, risperidone, sulpiride, zotepine and zuclopenthixol and the pharmacologically active metabolites norclozapine, clozapine N-oxide and 9-hydroxyrisperidone were extracted from plasma using solid-phase extraction and were separated on a Merck LiChroCART column with Superspher 60 RP Select B as the stationary phase. Gradient elution was performed using aqueous ammonium formate and acetonitrile. After screening and identification in the scan mode using the authors' new LC/MS library, the neuroleptics were quantified in the selected-ion mode. The quantification assay was fully validated. It was found to be selective and proved to be linear from sub-therapeutic to over therapeutic concentrations for all analytes. The corresponding reference levels are listed. The accuracy and precision data were within the required limits. The analytes were stable in frozen plasma for at least 1 month. The method was successfully applied to several authentic plasma samples from patients treated or intoxicated with various neuroleptics. The validated LC/MS assay has proved to be appropriate for the isolation, separation, screening, identification and quantification of various neuroleptics in plasma for clinical toxicology and therapeutic drug monitoring purposes.

Antipsychotic Agents↗

Trace analysis of organics in air by corona discharge atmospheric pressure ionization using an electrospray ionization interface.

A corona discharge ion source operating at atmospheric pressure in the point-to-plane configuration was constructed by reconfiguring the ion source of a commercial electrospray ionization (ESI) quadrupole mass spectrometer. This new source allows direct air analysis without modification to the mass spectrometer. Detection and quantitation of semi-volatile compounds in air is demonstrated. The analytical performance of the system was established using the chemical warfare agent simulants methyl salicylate and dimethyl methylphosphonate. Limits of detection are 60 pptr in the negative-ion mode and 800 pptr in the positive-ion mode for methyl salicylate and 800 pptr in the negative-ion mode and 3.6 ppb in the positive-ion mode for dimethyl methylphosphonate. A linear response was observed from 60 pptr to 8 ppb for methyl salicylate in air in the negative-ionization mode. Cluster ion formation versus production of analyte ions was investigated and it was found that dry air or an elevated capillary interface temperature (130 degrees C) was needed to avoid extensive clustering, mostly of water. Reagent gases are not needed as proton sources, as is usually the case for atmospheric pressure chemical ionization, and this, together with the simplicity, sensitivity and speed of the technique, makes it promising for miniaturization and future field studies.

Journal Article↗

Chloride-enhanced atmospheric pressure chemical ionization mass spectrometry of polychlorinated n-alkanes.

The use of high-performance liquid chromatography combined with chloride-enhanced atmospheric pressure chemical ionization for the determination of polychlorinated n-alkanes (PCAs, also called chlorinated paraffins or CPs) is described as an alternative to gas chromatographic methods. Atmospheric pressure chemical ionization in the negative ion mode formed exclusively [M+Cl](-) adduct ions and suppressed fragmentation when a chlorinated solvent was added. Limits of detection were 1-2 ng/microL for technical PCA mixtures. Response factors for single short-chain PCA homologues with different degrees of chlorination varied by not more than a factor of 6.5. The developed method was applied for the determination of the composition of technical PCA mixtures as well as for the analysis of PCAs in household commodities. Medium-chain PCAs were found in paint samples at concentrations of 8.2-11.5% (w/w), compared with 7.4-11.5% obtained by gas chromatography combined with electron ionization tandem mass spectrometry.

Alkanes↗

High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometric analysis for small molecules in plasma.

A generic high-performance liquid chromatography (HPLC) system interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer was developed for the quantitative determination of small molecules in plasma in support of exploratory in vivo pharmacokinetics. This report summarizes the effects of variations in reversed-phase mode HPLC conditions such as mobile-phase flow rate, solvent composition, organic modifier content, and nebulizer temperature on the photoionization efficiency of both clozapine and lonafarnib. The matrix ionization suppression effect on this method was investigated using the postcolumn infusion technique. The procedure was used to quantitate plasma levels following oral administration of 42 drug discovery compounds to rats. The pharmacokinetic results of 42 drug discovery compounds in rats evaluated by both APPI and atmospheric pressure chemical ionization interfaces were found to be well correlated.

Administration, Oral↗

Poor reproducibility of in-source collisional atmospheric pressure ionization mass spectra of toxicologically relevant drugs.

The purpose of the study was to examine the intra- and interlaboratory reproducibility of mass spectra obtained with liquid chromatography-atmospheric pressure ionization mass spectrometry (LC--API-MS) both in electrospray (ESI) and atmospheric pressure chemical ionization (APCI) modes. Toxicologically relevant drugs of different polarity were selected as test substances: morphine-6-glucuronide, 6-monoacetylmorphine, codeine, lysergic acid diethylamide, methylenedioxymethamphetamine. The study was performed in two laboratories using identical instruments and in one using a slightly different instrument. Basic instrument settings and mobile phase were identical in all laboratories. Mass spectra of drugs were taken at four collision energy voltages and using mobile phase of different composition (four concentration levels of acetonitrile and of ammonium formate buffer). The experiments demonstrated that mass spectra of given drugs, obtained in identical conditions with identical instruments, may show very different degrees of fragmentation. Mass spectra obtained with different instruments differed profoundly not only in the degree of fragmentation, but also different fragments and adducts were observed. Short-term intralaboratory reproducibility of mass spectra was satisfactory. On the other hand, the long-term experiments showed different degrees of fragmentation of APCI-generated mass spectra at nominally identical fragmentation energy. The changes in the composition of the mobile phase (concentration of organic modifier or buffer molarity) did not affect the reproducibility of fragmentation to any relevant degree. The study showed that the interlaboratory exchange and use of mass spectrum library, generated by single-quadrupole (LC--API-MS instruments, is hardly feasible at the moment, even under very carefully standardized conditions.

Atmospheric Pressure↗

Atmospheric pressure photoionization mass spectrometry for analysis of fatty acid and acylglycerol lipids.

In this work, we optimize parameters and conditions for analysis of fatty acid ester and acylglycerol lipids by atmospheric pressure photoionization-mass spectrometry (APPI-MS). The investigated parameters include atmospheric pressure chemical ionization (APCI) nebulizer/vaporizer physical orientation and APPI lamp face position, solvent selections, mobile phase compositions and flow rates, cone voltages and probe temperatures. APPI sensitivity is found to be highly dependent on mobile phase compositions. Normal phase solvents offer much higher sensitivity and better peak shape than reversed phase for nonpolar lipids. Hexane and isooctane are found to be two solvents generating highest S/N for eicosapentaenoic acid (EPA) methyl ester. The effects of mobile phase flow rates on sensitivity are found to be target analytes and target ions specific. However, the flow rate changes do not significantly affect the sensitivity of three out of four tested analytes under normal phase conditions over tested flow rates of 50-500muL/min. Cone voltage is found to be one of key parameters affecting sensitivity. Optimum probe temperature is found to be more dependent on mobile phase compositions than on the specific target analytes. Aqueous reversed-phase mobile phase requires higher probe temperature than normal phase for better sensitivity. More volatile mobile phase solvents require lower probe temperature for analyte desolvation. APPI offers four to five decades of linear ranges under normal phase condition. Full scan mass spectra of individual lipid standards, custom lipid mixtures and natural fish oil show that APPI spectra are clean and very easy to interpret. APPI also gives stable, reproducible peak responses with good peak shape. Limits of detection (LODs) by FIA (S/N=3) are estimated to be 12pg for EPA methyl ester and monoarachidin, 19pg for diarachidin and 7pg for trielaidin. LODs on-column are estimated to be 94pg for EPA methyl ester, 90pg for monoarachidin and diarachidin and 24pg for trielaidin.

Atmospheric Pressure↗

Atmospheric pressure ionization mass spectrometry of purine and pyrimidine markers of inherited metabolic disorders.

Purines and pyrimidines are of interest owing to their significance in processes in living organisms. Mass spectrometry is a promising analytical tool utilized in their analysis. Two atmospheric pressure ionization (API) methods (electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI)) in both negative and positive modes applied to selected purine and pyrimidine metabolites (markers of inherited metabolic disorders) were studied. APCI is less sensitive to alkali metal cations present in a sample and offers higher response than ESI for studied compounds. Both of the techniques afford quasi-molecular ions, but fragmentation also occurs to a certain extent. However, the application of collision-induced dissociation of quasi-molecular ions is essential to confirm a certain metabolite in a sample. Fragmentation of both positive and negative ions was evaluated using multi-stage mass spectrometric experiments. Typical neutral losses correspond to molecules NH(3), H(2)O, HCN, CO, H(2)NCN, HNCO and CO(2). The ion [NCO](-) arises in the negative mode. The cleavage of the glycosidic C-N bond is characteristic for relevant metabolites. Other neutral losses (CH(2)O, C(2)H(4)O(2) and C(3)H(6)O(3)) originate from fragmentation of the glycosidic part of the molecules. In addition to fragmentation, the formation of adducts of some ions with applied solvents (H(2)O, CH(3)OH) was observed. The composition of the solution infused into the ion source affects the appearance of the mass spectra. Tandem mass spectra allow one to distinguish compounds with the same molecular mass (uridine-pseudouridine and adenosine-2'-deoxyguanosine). Flow injection analysis APCI-MS/MS was tested on model samples of human urines corresponding to adenosine deaminase deficiency and xanthine oxidase deficiency. In both cases, the results showed potential diagnostic usefulness.

Atmospheric Pressure↗

Effect of atmospheric-pressure plasma on adhesion characteristics of polyimide film.

In this work, the effect of atmospheric-pressure plasma treatments on surface properties of polyimide film are investigated in terms of X-ray photoelectron spectroscopy (XPS), contact angles, and atomic force microscopy (AFM). The adhesion characteristics of the film are also studied in the peel strengths of polyimide/copper film. As experimental results, the polyimide surfaces treated by plasma lead to an increase of oxygen-containing functional groups or the polar component of the surface free energy, resulting in improving the adhesion characteristics of the polyimide/copper foil. Also, the roughness of the film surfaces, confirmed by AFM observation, is largely increased. These results can be explained by the fact that the atmospheric-pressure plasma treatment of polyimide surface yields several oxygen complexes in hydrophobic surfaces, which can play an important role in increasing the surface polarity, wettability, and the adhesion characteristics of the polyimide/copper system.

Journal Article↗

Atmospheric pressure photoionization. 1. General properties for LC/MS.

In this work, we describe the performance of an atmospheric pressure photoionization (APPI) source for sampling liquid flows. The results presented here primarily focus on the mechanism of direct photoionization (PI), as compared to the dopant mechanism of PI. Measured detection limits for direct APPI were comparable to atmospheric pressure chemical ionization (APCI; e.g., 1 pg for reserpine). The ion signal is linear up to 10 ng injected quantity, with a useful dynamic range exceeding 100 ng. Evidence is presented indicating that APPI achieves significantly better sensitivity than APCI at flow rates below 200 microL/min, making it a useful source for capillary liquid chromatography and capillary electrophoresis. Results are presented indicating that APPI is less susceptible to ion suppression and salt buffer effects than APCI and electrospray ionization (ESI). The principal benefit of APPI, as compared to other ionization sources, is in efficiently ionizing broad classes of nonpolar compounds. Thus, APPI is an important complement to ESI and APCI by expanding the range and classes of compounds that can be analyzed. In this paper, we also discuss the role of direct APPI vs PI-induced APCI using dopants.

Journal Article↗

Studies on neurosteroids XVII. Analysis of stress-induced changes in neurosteroid levels in rat brains using liquid chromatography-electron capture atmospheric pressure chemical ionization-mass spectrometry.

The analysis of stress-induced changes in the brain neurosteroid levels by liquid chromatography (LC)-electron capture atmospheric pressure chemical ionization-mass spectrometry (ECAPCI-MS) is described. In the present method, neurosteroids were derivatized with a highly electron-affinitive reagent, 2-nitro-4-trifluoromethylphenylhydrazine (NFPH), to convert them to the corresponding hydrazones. The derivatized steroids showed over a 20-fold higher sensitivity in ECAPCI-MS than intact steroids measured by positive atmospheric pressure chemical ionization (APCI)-MS. Application of this method to the analysis of rat brain samples confirmed the significant increase in the levels of pregnenolone (PREG), progesterone (PROG), 5alpha-dihydroprogesterone (DHPROG), allopregnanolone (3alpha-hydroxy-5alpha-pregn-20-one; AP), and epiallopregnanolone (3beta-hydroxy-5alpha-pregn-20-one; EpiAP) in the fixated rats. The din stress, which we examined as a new short-term mental stress model, also elevated the brain neurosteroid levels. It is known that various types of stress lower the gamma-aminobutyric acid type A (GABA(A)) receptor function and induce the neuronal overexcitation. The increase in the brain level of AP, a potent positive modulator of GABA(A) receptors, may be the defensive response against acute stress. The increase in the brain concentration of its precursors, PREG, PROG, and DHPROG, may be associated with the acceleration of the AP synthesis. Thus, the present studies suggest that changes in the brain levels of neurosteroids may play an important role in the homeostatic mechanisms that counteract the inhibitory effect of stress on the GABA(A) receptor function.

Animals↗

Phenol production in benzene/air plasmas at atmospheric pressure. Role of radical and ionic routes.

Benzene can be efficiently converted into phenol when it is treated by either corona or dielectric barrier discharge (DBD) plasmas operating at atmospheric pressure in air or mixtures of N(2) and O(2). Phenol produced by corona discharge in an atmospheric pressure chemical ionization source (APCI) has been detected as the corresponding radical cation C(6)H(5)OH(+*) at m/z 94 by an ion trap mass spectrometer. On the other hand, phenol has been observed also as neutral product by gas chromatography-mass spectrometry analysis (GC-MS) after treatment in a DBD plasma. Experiments aimed at shading light on the elementary processes responsible for benzene oxidation were carried out (i) by changing the composition of the gas in the corona discharge source; (ii) by using isotopically labeled reagents; and (iii) by investigating some relevant ion-molecule reactions (i.e. C(6)H(6)(+*) + O(2), C(6)H(5)(+) + O(2)) via selected guided ion beam measurements and with the help of ab initio calculations. The results of our approach show that ionic mechanisms do not play a significant role in phenol production, which can be better explained by radical reactions resulting in oxygen addition to the benzene ring followed by 1,2 H transfer.

Air↗

The role of atmospheric pressure variation in the development of spontaneous pneumothoraces.

It has been postulated that spontaneous pneumothoraces (SP) develop because of rupture of subpleural blebs, and that atmospheric pressure changes (delta AP) may be contributory. A 5-year retrospective analysis of SP admissions was carried out to determine if delta AP do play a role in SP development. Using a 36-yr record of hourly delta AP, a normative background for delta AP was constructed. A fall in AP below the fifth, or a rise above the ninety-fifth percentile during these time periods, was classed as "unusual." Atmospheric pressure changes in the 4 days prior to SP were analyzed. The expected frequency of SP occurring by chance, if no relationship to delta AP existed, was also calculated. A total of 192 cases of SP was analyzed. Traumatic pneumothoraces were excluded. The majority of cases (72%) had been exposed to at least one "unusual" delta AP in the 4 days prior to onset of symptoms. Among those with four or more "unusual" exposures, SP occurrence was significantly more frequent than expected by chance alone (p less than 10(-10]. A strong positive association between delta AP and SP was not found in all cases, as delta AP are unlikely to be the only causative factor for SP. This finding of a relationship with ambient pressure changes lends support to the theory that SP develop as a result of rupture of subpleural blebs.

Adult↗

Automated protein identification using atmospheric-pressure matrix-assisted laser desorption/ionization.

Atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) ion trap mass spectrometry (ITMS) has been evaluated for automated protein identification. By using signal averaging and long ion-injection times, protein identification limits in the 50-fmol range are achieved for standard protein digests. Data acquisition requires 7.5 min or less per sample and the MS/MS spectra files are automatically processed using the SEQUEST database searching algorithm. AP-MALDI-ITMS was compared with the widely used methods of microLC/MS/MS (ion trap) and automated MALDI-TOF peptide mass mapping. Sample throughput is 10-fold greater using AP-MALDI compared with microcapillary liquid chromatography/tandem mass spectrometry (microLC/MS/MS). The protein sequence coverage obtained from AP-MALDI-MS/MS spectra matched by SEQUEST is lower compared with microLC/MS/MS and MALDI-TOF mass mapping. However, by using the AP-MALDI full-scan peptide mass fingerprint spectrum, sequence coverage is increased. AP-MALDI-ITMS was applied for the analysis of Coomassie blue stained gels and was found to be a useful platform for rapid protein identification.

Animals↗

Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry.

The suitability of atmospheric pressure chemical ionization mass spectrometry as sensing instrumentation for the real-time monitoring of low levels of toxic compounds is assessed, especially with respect to public safety applications. Gaseous samples of nine toxic industrial compounds, NH3, H2S, Cl2, CS2, SO2, C2H4O, HBr, C6H6 and AsH3, and two chemical warfare agent simulants, dimethyl methylphosphonate (DMMP) and methyl salicylate (MeS), were studied. API-MS proves highly suited to this application, with speedy analysis times (<30 seconds), high sensitivity, high selectivity towards analytes, good precision, dynamic range and accuracy. Tandem MS methods were implemented in selected cases for improved selectivity, sensitivity, and limits of detection. Limits of detection in the parts-per-billion and parts-per-trillion range were achieved for this set of analytes. In all cases detection limits were well below the compounds' permissible exposure limits (PELs), even in the presence of added complex mixtures of alkanes. Linear responses, up to several orders of magnitude, were obtained over the concentration ranges studied (sub-ppb to ppm), with relative standard deviations less than 3%, regardless of the presence of alkane interferents. Receiver operating characteristic (ROC) curves are presented to show the performance trade-off between sensitivity, probability of correct detection, and false positive rate. A dynamic sample preparation system for the production of gas phase analyte concentrations ranging from 100 pptr to 100 ppm and capable of admixing gaseous matrix compounds and control of relative humidity and temperature is also described.

Air Pollutants↗