Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography.

A high degree of uncertainty and irritation predominates in the assessment and comparison of radiation dose values resulting from measurements of bone mineral density of the lumbar spine by photon absorptiometry and X-ray computed tomography. The skin dose values which are usually given in the literature are of limited relevance because the size of the irradiated volumes, the relative sensitivity of the affected organs and the radiation energies are not taken into account. The concept of effective dose, sometimes called whole-body equivalent dose, has to be applied. A detailed analysis results in an effective dose value of about 1 microSv for absorptiometry and about 30 microSv for computed tomography when low kV and mAs values are used. Lateral localizer radiographs, which are necessary for slice selection in CT, mean an additional dose of 30 microSv. Lateral X-ray films of the spine which are frequently taken in combination with absorptiometry result in a dose of 700 microSv or more. The concept of effective dose, the basic data and assumptions used in its assessment and a comparison with other dose burdens (for example the natural background radiation, of typically 2400 microSv per year) are discussed in detail.

Absorptiometry, Photon↗

Estimation of vertebral body strength by dual photon absorptiometry in elderly individuals: comparison between measurements of total vertebral and vertebral body bone mineral.

The aim of the present study was to investigate the predictive value of bone mineral measurements by dual photon absorptiometry (DPA) in vitro for strength and ash weight of lumbar vertebral bodies in elderly, otherwise nonselected individuals. The material comprised 46 individuals: 26 males (43-95 years) and 20 females (63-95 years) without malignant diseases. Spinal segments, including L2, L3, and L4, were removed en bloc at autopsy. Bone mineral content (BMC) measurements imitating the normal DPA procedure were performed on the segments suspended in a water bath. The segments were measured in toto (BMCT) and remeasured after removal of the posterior elements (BMCB). The second lumbar vertebral body (L2) was then dissected and sawed below the endplates to obtain samples with planoparallel ends before compression in a materials testing machine. Finally, the bone specimens were incinerated for ash weight estimations. BMCT showed significant correlations to vertebral body ash weight (r = 0.79), compressive strength (load, r = 0.69), and stress (load per unit area, r = 0.47). The correlations were improved by removing the posterior elements (BMCB-ash weight, r = 0.86, BMCB-load, r = 0.74, BMCB-stress, r = 0.49). Correction of BMC for differences in vertebral body height (BMC/cm) further increased the correlation coefficients (BMCB/cm-ash weight, r = 0.92, BMCB/cm-load, r = 0.78, BMCB/cm-stress, r = 0.55). We conclude that lumbar BMC is predictive for lumbar vertebral body compressive strength in vitro and ash weight. The correlation coefficient is improved by removing the posterior non-weight-bearing element.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis.

The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies, and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis.

Absorptiometry, Photon↗

Measurement of the subcutaneous fat in the distal forearm by single photon absorptiometry.

The influence of subcutaneous fat on single photon (125I) absorptiometry (SPA) measurement of bone mineral content of the distal forearm was investigated. A fat correction model was tested by measurements on eight lean subjects with different amounts of porcine fat around their forearm, and further validated from measurements on 128 females. In addition, it is shown that the fat content in the distal forearm can be measured by SPA with a short-term precision at 1.9% in an obese subject and that it correlates well with total body fat (r2 = .7) measured by dual photon absorptiometry, skinfold thickness (r2 = .5), and body mass index (r2 = .6). By using this method in a double-blind placebo-controlled trial, hormonal substitutional therapy significantly decreased the forearm fat content without affecting the body weight in postmenopausal osteoporotic women.

Adipose Tissue↗

Irreversible bone loss in osteomalacia. Comparison of radial photon absorptiometry with iliac bone histomorphometry during treatment.

We examined the relationships between the changes in bone mineral deficit in the radius, determined by single-energy photon absorptiometry at standard proximal and distal sites, and in the ilium, determined by bone histomorphometry, during the treatment of osteomalacia of diverse etiology in 28 patients. In the ilium, relative osteoid volume decreased by 75-80% in both cortical bone (from 6.0% to 1.5%) and trabecular bone (from 30.1% to 6.6%) during a mean treatment duration of 2 yr. There was also a significant fall in iliac cortical porosity from 10.3% to 7.8%. As a result, mineralized bone volume increased by 7.5% in cortical and by 40.1% in trabecular bone; the cortical and trabecular increments were correlated (r = 0.69, P less than 0.001). The properly weighted increase for the entire tissue sample was 18.6%. By contrast, there was no change in bone mineral at either radial site, although there was a 2% increase at both sites when allowance was made for age-related bone loss during treatment. The proximal and distal age-adjusted increments was correlated (r = 0.76, P less than 0.001), but there was no correlation between the changes in any photon absorptiometric and any histomorphometric index. In that iliac cortical bone turnover in normal subjects was 7.2%/yr, we estimated the rate of bone turnover to be less than 2%/yr at both proximal and distal radial sites, including any trabecular bone present at the distal site. Compared to appropriate control subjects, the bone mineral deficits fell during treatment from 19.2% to 17.1% at the proximal radius (greater than 95% cortical bone) and from 20.5% to 18.5% at the distal radius (greater than 75% cortical bone). In the ilium the deficits, assuming attainment of normal values for osteoid volume and cortical porosity, fell from 41.7% to 36.1% in cortical and from 31.5% to 6.3% in trabecular bone, the properly weighted combined deficit falling from 38.6% to 27.7%. The irreversible iliac cortical deficit was entirely due to cortical thinning because of increased net endosteal resorption; the resultant expansion of the marrow cavity offset the modest loss of fractional trabecular mineralized bone. We conclude: in osteomalacia there is a large irreversible and a small reversible bone mineral deficit at both proximal and distal radial sites, in similar proportion to the iliac cortex but of smaller magnitude; the anatomic basis of the irreversible bone mineral deficit at all three sites that persists despite correction of the mineralization defect by appropriate treatment is thinning of cortical bone, most likely owing to prolonged secondary hyperparathyroidism; (c) there is no evidence that the proportion of trabecular bone in the distal radius at any site proximal to the radioulnar joint has any relevance to the interpretation of measurements made at that site; (d) there are at least three functional subdivisions of trabecular bone depending on proximity to hematopoietic marrow, fatty marrow, or synovium; and (e) single photon absorptiometry of the radius is an excellent method for measuring cortical bone mass in the appendicular skeleton, but is of little value for the assessment of changes in trabecular bone status.

Biopsy↗

Total body bone mineral and lean body mass by dual-photon absorptiometry. I. Theory and measurement procedure.

A method was developed for measuring total body bone mineral (TBBM) and lean body mass in vivo using dual-photon absorptiometry. The entire body was scanned in a rectilinear raster (transverse speed of 1 cm/s and longitudinal steps of 2.5 cm) with a modified nuclear medicine scanner and conventional nuclear counting electronics. The source was 153Gd (1 Ci) with principal photopeaks at 44 and 100 keV. The scan time was about 70 min with an absorbed dose of under 1 mrem. The low dose allows measurements to be repeated at frequent intervals or used on children. Short-term (months) precision of TBBM was about 1.5% for isolated skeletons and about 2% on normal human subjects. Long-term (years) precision on skeletons was under 3%. The precision of percent fat was 0.9%, which would lead to an error of less than 1% in the TBBM. Geometry of measurements also had minimal (and correctable) influence on the accuracy of results. The accuracy (1 standard error of estimate) of TBBM on isolated skeletons (N = 5) was 36 g (equivalent to about 13 g of Ca) with a correlation coefficient of 0.99; this error amounts to about 1--1.5% in normal adults; 2% in older women, and 2.5% in osteoporotic females. The dual-photon absorptiometry method could be implemented in many nuclear medicine departments to follow skeletal changes during growth and aging or to follow the course of a disease or treatment.

Body Composition↗

Dual photon absorptiometry using a gadolinium-153 source applied to measure equine bone mineral content.

The application of the dual photon absorptiometry (DPA) technique, using gadolinium-153 as the photon source, to evaluate the bone mineral density (BMD) of the third metacarpal bone of horses is presented. The radiation detector was implemented with a NaI(TI) scintillator coupled to a 14 stage photomultiplier. A modular mechanical system allows the position of the prototype to be adjusted in relation to the animal. A moveable carrier makes it possible to scan the third metacarpal with a velocity adjustable between 1 and 12 mm s(-1), in steps of 1 mm s(-1), for a total distance of 250 mm. The prototype was evaluated with a phantom of the third metacarpal bone made of perspex and aluminium, and in vitro with a transverse slice of the third metacarpal bone of a horse. The tests showed that the prototype has an accuracy and precision of, approximately, 10% and 6%, respectively, for a 6 s acquisition time. Preliminary studies carried out in three foals from birth to one year of age indicated that the prototype is well suited to in vivo and in situ analysis of the BMD of the third metacarpal bones of horses, making it possible to evaluate the changes of BMD levels on a monthly basis. Also, results indicated an exponential behaviour of the BMD curve during the first year of life of the studied horses.

Absorptiometry, Photon↗

Comparison of dual-photon absorptiometry systems for total-body bone and soft tissue measurements: dual-energy X-rays versus gadolinium 153.

A total of 81 subjects (41 males and 40 females) were scanned by dual-photon absorptiometry by 153Gd source (DPA; Lunar DP4) and by dual-energy x-ray absorptiometry (DEXA; Lunar-DPX) within a 24 h period. Total-body bone mineral density (TBMD), calcium content (Ca), and soft tissue mass (ST) were determined with a precision of about 1-1.5% using DPA and 0.5-1.0% using DEXA. Measurements of TBMD, Ca, ST, bone area (area), percentage fat, and regional bone mineral densities (BMD) were compared. Paired t-tests showed small but significant differences between all measurements. Correlations (r) for TBMD, Ca, area, ST, percentage fat, arm BMD, leg BMD, and trunk BMD were 0.99, 0.99, 0.97, 0.99, 0.97, 0.99, 0.99, and 0.98. There were small systematic differences for TBMD (less than 1%), calcium (3%), bone area (3%), soft tissue mass (7%), and percentage fat (9%) between the two approaches. Regression equations are given relating these measurements.

Absorptiometry, Photon↗

Comparison of ultrasound transmission velocity with computed metacarpal radiogrammetry and dual-photon absorptiometry.

The aim of our study was to evaluate the validity of a quantitative US technique for measuring the bone density of the proximal phalanges of the nondominant hand compared with computed metacarpal radiogrammetry and dual-photon absorptiometry (DPA) of the lumbar spine. Mean US bone velocity (UBV) correlated with mean metacarpal cortical index (MCI), with mean metacarpal bone density (MBD) and with bone mineral density (BMD) of the lumbar spine, whereas it was correlated negatively with age and menopause duration. The average UBV was significantly higher in premenopausal women than in postmenopausal women, and higher in normal lumbar DPA patients than in reduced lumbar DPA patients. We conclude that the US evaluation of the nondominant hand proximal phalanges may be a new alternative way for measuring bone mass in screening of osteoporosis.

Absorptiometry, Photon↗

Bone mineral content in black pre-schoolers: normative data using single photon absorptiometry.

Fifty-nine children aged 18 to 47 months with normal and elevated blood lead levels had bone mineral density (BMD in gm/cm2) and bone mineral content (BMC in gm/cm) measured using the technique of single photon absorptiometry of the radius shaft. No normative data are available for black children of this age group. Moderate elevations of blood lead were not found to influence bone mineralization. The BMC of the study children was significantly higher than the published values for white children of the same age. We found no statistical difference between the bone mineral density of males and females in this age group.

Absorptiometry, Photon↗

Bone mineral content by photon absorptiometry of the mandible compared with that of the forearm and the lumbar spine.

A new method for measuring the bone mineral content (BMC) of the mandible by dual-photon absorptiometry (DPA) has recently been introduced. The purpose of the present investigation therefore was to examine the long-term precision for 32 months in vitro and in vivo for assessment of BMC in the mandible and to examine the relationship in vivo among BMC of the mandible, the forearms, and the lumbar spine as measured by DPA and/or single-photon absorptiometry (SPA). For comparison, the relationship between forearm BMC as measured by DPA and SPA was studied. The long-term precision of the mandibular BMC was 0.8% in vitro, independent of age and change of radioactive source, and 2.1% by assessment in vivo. A significant relationship (P less than 0.01) was found between BMC of the lumbar spine and the forearms and between the two sets of forearm BMC measured by DPA and SPA. Thus, relative BMC changes of the forearms can be compared without respect to type of forearm bone scanner used. The BMC changes of the mandible can only be evaluated by scanning of the mandible itself. The present DPA bone scanner is suitable for follow-up analyses of the BMC changes of the mandible and the forearms.

Adult↗

Bone mineral content of the maxilla estimated by dual-photon absorptiometry after augmentation with bone or hydroxyapatite.

A new, precise, non-invasive method for measuring the bone mineral content (BMC) of the mandible in vivo by dual-photon absorptiometry has recently been introduced. The purpose of the present analysis was to examine the precision in vitro and in vivo and the accuracy in vivo for assessment of BMC in the maxilla. The precision was determined by repeated measurements in vitro on a cranium and in vivo on two test persons with and without a bone specimen fixed to a palatal plate. The accuracy in vivo was determined from the BMC measurements of the two test persons and of nine edentulous persons, scanned before and after augmentation of the maxillary alveolar ridge with hydroxyapatite. The analyses indicated that the precision for maxillary BMC assessments was high (0.9% in vitro and 2.0% in vivo) and the accuracy in vivo was 6.6%, corresponding to the accuracy in vitro for skeletal BMC measurements by dual-photon absorptiometry. The present method therefore seems to be well-suited for follow-up analyses of the BMC changes in the jaws after augmentation of the alveolar ridges with bone or hydroxyapatite.

Alveolar Ridge Augmentation↗

Triple photon absorptiometry cannot correct for fat inhomogeneities in lumbar spine bone mineral measurements.

In vivo fat inhomogeneities can cause significant errors in measurements of lumbar spine mineral mass using dual photon absorptiometry. Extension to a triple photon technique to correct for the presence of fat is not possible because of the unacceptable increase of about a factor of 3,000 required in the radiation dose to yield sufficient transmitted photons for adequate precision.

Absorptiometry, Photon↗

Regional variations in bone mineral density as assessed with dual-energy photon absorptiometry and dual x-ray absorptiometry.

Total-body, lumbar spine, and hip bone mineral density (BMD) scans were obtained in postmenopausal women to examine regional variations in mineralization of trabecular bone. One hundred ninety-nine patients were studied with dual-energy photon absorptiometry (DPA) and/or dual x-ray absorptiometry (DXA). Comparison of BMD at the different sites showed statistically significant correlations (P < .001) among all the sites; however, variations between sites were observed in many patients. Total-body measurements were within normal limits as defined by the system software in 90% of patients with substantial bone mineral loss in the spine or hip. Lumbar spine measurements calculated from the total-body scan differed from the direct measurements by an average of 10% (DPA) and 12% (DXA). These results suggest that site-specific measurements are required to assess regional osteopenia. While total-body scans may be precise and offer the advantage of total-body composition determination, BMD values derived from total-body scans cannot currently replace direct measurements.

Absorptiometry, Photon↗

[Measurement of bone mineral content by single-photon absorptiometry in children].

Bone mineral content (BMC) was measured in 64 children (33 boys [aged 4-17] and 31 girls [aged 2-12]) having no signs of metabolic bone disease, at the distal third of their radius using single photon absorptiometry (SPA), to establish normative data. Relationships were studied between the obtained bone mineral content and the age, weight, as well as height of children. The obtained BMC values were compared with that of healthy Swedish and American children. Authors suggest the routine use of SPA in home children suffering from metabolic bone diseases.

Absorptiometry, Photon↗

Diagnostic notes--lumbar BMC reproducibility as evaluated by means of dual photon absorptiometry.

Three evaluations of lumbar bone mineral content (BMC) were carried out at different times at intervals of a few days in 10 normal volunteers aged between 18 and 60. The dual photon absorptiometry technique was employed (using gadolinium-153 as radioactive isotope). Data on 20 subjects aged from 23 to 62 were recorded on magnetic tape and processed ten times by the same operator. The data for individual subjects proved satisfactorily reproducible and the repeated processing of a single scan by the same investigator gave very satisfactory results. The findings demonstrate that the evaluation of lumbar BMC by dual photon absorptiometry can provide highly reproducible and acceptably accurate data.

Adult↗

Effects of glucocorticoids on skeletal growth in rabbits evaluated by dual-photon absorptiometry, microscopic connectivity and vertebral compressive strength.

The effects of corticosteroid on bone were examined in female growing rabbits treated with 0.7 mg/kg per day prednisolone for 5 months. The evolution of whole-body total bone mineral measured by dual-photon absorptiometry showed a significant difference between the prednisolone-treated group and the control group from the first to the fifth month. The histomorphometric profile of corticosteroid-induced osteoporosis was observed, in particular the lower bone volume and thinner and fewer trabecular plates. Mechanical tests are possible on rabbit vertebrae and showed a very significant difference in bone strength between the prednisolone-treated and control groups, and a good correlation between mechanical tests and histomorphometric or densitometric results. This bone corticosteroid model shows that vertebral compression tests are possible on rabbit lumbar vertebrae. It may contribute to a better evaluation of corticosteroid treatments.

Absorptiometry, Photon↗

Comparison of nuclear magnetic resonance spectroscopy with dual-photon absorptiometry and dual-energy X-ray absorptiometry in the measurement of thoracic vertebral bone mineral density: compressive force versus bone mineral.

31P nuclear magnetic resonance spectroscopy (NMRS) measurements were made on human T2 and T3 vertebral bodies. The bone mineral content (BMC) of isolated vertebral bodies minus the posterior elements and disks was measured using (1) NMRS on a 3.5 T, 85 mm bore GE Medical Systems NT-150 superconducting spectrometer, (2) a Lunar Corporation DPX-L dual-energy X-ray absorptiometry (DXA) scanner in an anterior-posterior (AP) orientation, (3) a Norland Corporation XR26 DXA scanner, also in an AP direction, and (4) a Norland Corporation model 2600 dual-photon absorptiometry (DPA) densitometer in both the AP and superior-inferior (SI) directions. Vertebral body volumes were measured using a water displacement technique to determine volume bone mineral densities (VBMD). They were then compressed to failure using an electrohydraulic testing device, followed by ashing in a muffle furnace at 700 degrees C for 18 h. Correlations of BMC between NMRS and DPA, DXA and ashing were excellent (0.96 < or = r < or = 0.99); in a one-way analysis of variance (ANOVA) test, means were not statistically different at a p level of 0.757. The correlations of VBMD between NMRS and the other methods were not as good (0.83 < or = r < or = 0.95); in a one-way ANOVA test, means were not statistically different at a p level of 0.089. BMC was a better predictor of ultimate compressive failure than VBMD for all six methods. For NMRS, the regression coefficient for BMC was r2 = 0.806, compared with r2 = 0.505 for VBMD. NMRS may prove an alternative to present methods of determining bone mineral.

Absorptiometry, Photon↗