PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Treatment of midclavicular nonunion: comparison of dynamic compression plating and low-contact dynamic compression plating techniques.

In this study a comparison of patients with midclavicular nonunion, treated by a combination of internal fixation with dynamic compression plate (DCP) or low-contact DCP (LC-DCP) and application of autogenous corticocancellous chips or sculptured graft on nonunion areas, was performed. Time to union in the patients treated with LC-DCP fixation was shorter than in those treated with DCP fixation (P <.001). Union was obtained in all patients treated with LC-DCP fixation and in 87.5% of those treated with DCP fixation. All of those treated with LC-DCP fixation returned to their original jobs, whereas two patients treated with DCP fixation had to change jobs. According to the Disabilities of the Arm, Shoulder, and Hand functional score, at the last follow-up visit, functional outcomes of the patients treated with LC-DCP fixation were more satisfactory (P <.001). The addition of internal fixation of the clavicle with DCP or LC-DCP to application of autogenous corticocancellous chips, or sculptured graft on nonunion areas in patients with midclavicular nonunion, shortens the time to union, increases union rates, and provides satisfactory functional outcomes.

Adult↗

Balloon kyphoplasty for vertebral compression fractures in solid organ transplant recipients: results of treatment and comparison with primary osteoporotic vertebral compression fractures.

BACKGROUND CONTEXT: Balloon kyphoplasty has become established as a useful treatment for vertebral compression fractures (VCF) associated with primary osteoporosis and osteolytic tumors. Organ transplant recipients are also at risk for VCF because of their underlying disease process and because they require long-term treatment with steroids and other immunosuppressive drugs. PURPOSE: To explore whether balloon kyphoplasty is an effective treatment for VCF that develop in solid organ transplant recipients. A secondary goal was to determine whether there are any differences between VCF in transplant patients and VCF in patients with primary osteoporosis, with respect to disease severity and new fracture development. STUDY DESIGN: Prospective, longitudinal clinical series. PATIENT SAMPLE: The transplant group included 10 consecutive transplant patients (9 liver and 1 kidney), with a total of 29 symptomatic VCFs. The comparison group included 10 consecutive patients with primary osteoporosis and no history of organ transplantation, with a total of 15 VCFs. OUTCOME MEASURES: The primary clinical end point was back pain, measured using the Visual Analog Scale (VAS), which was recorded at baseline, and 1 and 12 months postprocedure. Radiographic evaluation included measurement of Cobb angles for each treated vertebral segment on preprocedure and 1-month postprocedure lateral radiographs. An improvement of >5 degrees was considered significant. The number of fractures seen at the time of diagnosis and the number of new fractures occurring during the follow-up period were recorded. METHODS: Balloon kyphoplasty was performed at all symptomatic levels. All fractures were treated within 3 months of onset. Patient follow-up was 12 months. RESULTS: The transplant group had significantly higher levels of pain at baseline, (mean VAS 9.3 and 7.7 for the transplant group and primary osteoporosis group, respectively: p=.013). After treatment, the VAS decreased to 3.2 in the transplant group and 1.5 in the comparison group. Improvement was highly significant in both groups (p<.001), and was maintained at 12-month follow-up. Sagittal alignment was improved by >5 degrees in three patients in each group (30%). There were no procedural complications in either group. Compared with the primary osteoporosis group, the transplant group was more likely to have multiple fractures at the time of diagnosis (2.9 vs. 1.5, p=.03), had a twofold greater incidence of new fractures during the follow-up period (40% vs. 20%), was more than a decade younger (64 vs. 75 years, p<.01), was much more likely to have received chronic immunosuppressive therapy with glucocorticoids and calcineurin phosphate inhibitors (100% vs. 0%, p<.001), and had a higher percentage of males (70% vs. 10%, p=.02), CONCLUSIONS: These data suggest that balloon kyphoplasty can be performed safely in organ transplant recipients with VCFs. The degree of pain relief is equivalent to that seen in patients with primary osteoporosis. Results are durable at 12-month follow-up. Transplant patients developed earlier and more severe bony disease, with more severe baseline pain, a higher incidence of multiple fractures at the time of diagnosis, and a greater risk of new fracture development posttreatment, as compared with the primary osteoporosis group.

Aged↗

The compressive deformation of multicomponent microcapsules: influence of size, membrane thickness, and compression speed.

The clinical application of microcapsules for the immunoisolation of living tissue requires knowledge about the mechanical stability of polymer membranes. Microcapsules of 400-1000 microm in diameter were formed through the gelation of sodium alginate/sodium cellulose sulfate droplets through calcium chloride, with the membrane produced via complex coacervation between polyanions and poly(methylene-co-guanidine) hydrochloride. The deformation behavior of these multicomponent microcapsules was investigated by uniaxial compression experiments. Specifically, the influence of the deformation speed, capsule diameter, and membrane thickness on the mechanical properties was evaluated. The bursting force was found to be dependent on the deformation speed. Therefore, the measurement of the bursting work, a speed-independent value of the resistance to high stresses and deformations, was recommended as the most valid for capsule mechanical resistance. Furthermore, the bursting force was positively correlated with membrane thickness only for membrane-radius ratios up to 20%. For thicker membranes, the bursting event occurred because the opposite membranes touched each other, and not, because of insufficient strength. Indeed, the resistance to smaller deformations was positively correlated to the membrane thickness over the whole range of membrane-radius ratios. Moreover, the forces for constant deformation were linearly correlated to the total membrane volume, independently of capsule size and membrane thickness.

Biocompatible Materials↗

[Methods of instrumental physiotherapy in the rehabilitative treatment of pareses caused by nerve compression of the extremities and spinal nerve root compression].

The controlled study of comparative effectiveness of magnetic stimulation, infrared pulsed laser therapy, niacin electrophoresis by sinusoidal modulated current and ultrasound was conducted for 109 patients with flaccid pareses caused by nerve or spinal root compression. The patients were randomly assigned to 4 treatment groups (control group was exposed to laser imitation). The results obtained favour magnetic stimulation and laser as analgetics and reducers of motor deficiency. The benefit from the use of niacin electrophoresis was not proved in this study.

Adult↗

Enhancing venous outflow in the lower limb with intermittent pneumatic compression. A comparative haemodynamic analysis on the effect of foot vs. calf vs. foot and calf compression.

OBJECTIVES: intermittent pneumatic compression (IPC), an established method of deep-vein thrombosis prophylaxis, is also an effective means of leg inflow enhancement, improving the walking capacity and ankle pressure of claudicants, long-term. This study, using duplex ultrasonography, compares the haemodynamic effect of IPC of the (a) foot (at 120 mmHg [IPC(foot/120 mmHg)], and 180 mmHg [IPC(foot/180 mmHg)]), (b) calf (IPC(calf), 120 mmHg) and (c) both simultaneously (IPC(foot+calf), 120 mmHg), on the venous outflow of 20 legs of normals and 25 legs of claudicants. RESULTS: the peak and mean velocities, volume flow and pulsatility index in the superficial femoral and popliteal veins of both groups increased significantly with all IPC modes (p<0.001). IPC(foot+calf)produced the highest enhancement followed by IPC(calf)(p<0.01), which was more effective (p<0.001) than either IPC(foot/180 mmHg)or IPC(foot/120 mmHg). The venous volume expelled with IPC(calf)and IPC(foot+calf)was 2-2.5 and 3-3.5 times that with IPC(foot/180 mmHg)respectively. Velocity enhancement with IPC was similar between groups and the superficial femoral and popliteal veins. IPC(foot/180 mmHg)produced higher (p<0. 01) flow velocities than IPC(foot/120 mmHg)in both groups and veins examined; however, differences were limited. CONCLUSIONS: all IPC modes proved effective, IPC(foot+calf)generating the highest venous outflow enhancement. Higher venous volumes expelled with IPC(foot+calf)explain its reported superiority on leg inflow over the other modes. Increase of applied pressure from 120 to 180 mmHg with IPC(foot)offered only a small outflow improvement. Venous haemodynamics at rest and with IPC in claudicants do not differ significantly from those in healthy subjects.

Adult↗

High-frequency chest compression: effect of the third generation compression waveform.

High-frequency chest compression (HFCC) therapy has become the prevailing form of airway clearance for patients with cystic fibrosis (CF) in the United States. The original square waveform was replaced in 1995 with a sine waveform without published evidence of an equality of effectiveness. The recent development of a triangle waveform for HFCC provided the opportunity to compare the functional and therapeutic effects of different waveforms. Clinical testing was done in patients at home with therapy times recorded with all sputum collected in preweighed sealable vials. The eight study patients with CF were regular users of a sine waveform device. They produced sputum consistently and were clinically stable. They used their optimum frequencies for therapy for each waveform and, for one week for each waveform, collected all sputum during their twice-daily timed HFCC therapies. After collection, these vials were reweighed, desiccated, and reweighed to calculate wet and dry weights of sputum per minute of therapy time. Frequency associated vest pressures transmitted to the mouth, and induced airflows at the mouth were measured in healthy volunteers. The pressure waveforms produced in the vest were, in shape, faithfully demonstrable at the mouth. In the healthy subject the transmission occurred in 2 ms and was attenuated to about 75% of the vest pressure for the triangle waveform and 60% for the sine waveform. All patients produced more sputum with the triangle waveform than with the sine waveform. The mean increase was 20%+ range of 4% to 41%. P value was <.001. Future studies of HFCC should investigate the other effects of the sine and triangle waveforms, as well as the neglected square waveform, on mucus clearance and determine the best frequencies for each waveform, disease, and patient.

Biomedical Engineering↗

[Effect of benzonal on the absorptive-secretory function in the liver of immature rabbits in post-compression period of long-term compression syndrome].

The absorptive-secretory function of hepatocytes using chromodiagnostic test by means of cardiogrin in rabbits at the age of 1 month in postcompression period of prolonged compression syndrome (PCS) was studied. It was established that the given function of hepatocytes was sufficiently and stably depressed for PCS. By effect of inductor of hepatocytes' monooxygenase system benzonal the disorders in parameters of cardiogreen pharmacokinetics are being distinctly removed. The velocity of blood stream in the liver was restored up to a level in health animals. It is supposed that an inclusion of benzonal into a complex of therapeutical remedies allows to enhance an effectiveness in PCS treatment during prepubescent period.

Absorption↗

Prophylaxis of deep vein thrombosis after major abdominal surgery. Comparison between dihydroergotamine-heparin and intermittent pneumatic calf compression and evaluation of added graduated static compression.

In a prospective, randomized study on 114 patients undergoing major abdominal surgery, the prophylactic effect of dihydroergotamine (DHE) combined with low-dose heparin (LDH) against postoperative deep vein thrombosis (DVT) was compared with that of peroperative intermittent pneumatic calf compression (IPCC). The additive effect of graduated pressure stockings was also studied, by randomizing a stocking to the right or left leg in each patient. The 125I-fibrinogen test was used to diagnose DVT. The incidence of postoperative DVT was significantly lower in the DHE-LDH than in the IPCC group (4% v. 19%). In the IPCC group the incidence of postoperative DVT was equal in legs with and without stocking. The study thus indicated that DHE-LDH is more effective than peroperative IPCC in preventing DVT after major abdominal surgery, and that graduated pressure stockings do not enhance the prophylactic effect of peroperative IPCC.

Abdomen↗